The electrocardiogram of high resolution during ventricular tachycardia

To evaluate by the signal averaged-ECG (SAECG) the initial portion of the activation of the sustained ventricular tachycardia (SVT) and monomorphic repetitive ventricular tachycardia (MRVT), correlating the findings with those obtained during sinus rhythm (SR). Ten patients was studied; five with SV...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Arquivos brasileiros de cardiologia 1994-06, Vol.62 (6), p.389-393
Hauptverfasser: Maia, I G, Cruz Filho, F, Boghossian, S H, Fagundes, M L, Costa, A M, Alves, P A
Format: Artikel
Sprache:por
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 393
container_issue 6
container_start_page 389
container_title Arquivos brasileiros de cardiologia
container_volume 62
creator Maia, I G
Cruz Filho, F
Boghossian, S H
Fagundes, M L
Costa, A M
Alves, P A
description To evaluate by the signal averaged-ECG (SAECG) the initial portion of the activation of the sustained ventricular tachycardia (SVT) and monomorphic repetitive ventricular tachycardia (MRVT), correlating the findings with those obtained during sinus rhythm (SR). Ten patients was studied; five with SVT and five with MRVT. Patients with SVT presented a positive SAECG while patients with MRVT the test was negative, during SR. The findings of this two populations were compared with those obtained in a group of ten patients with advanced bundle branch block (ABBB: five RBBB and five LBBB). We analyzed in the vector-magnitude obtained during VT and ABBB, the root mean square of the initial 40 ms portion of the activation (RMS40) and the duration of the low amplitude signals < 40 microV from the beginning of the filtered QRS (LAS). To define the positiveness of the test in SR, we analyzed the final RMS40 (normal > 20 microV), the duration of the LAS < 40 microV at the end of the activation (normal < 38 ms) and the total QRS duration (QRSD-normal < 114 ms). (mean)-SVT in SR: RMS40 = 11.2 +/- 6.2 microV; LAS = 47.4 +/- 5.8 ms; QRSD = 131.2 +/- 8.7 ms. SVT during VT: RMS40 = 6.9 +/- 4.5 microV; LAS = 54.5 +/- 9.1 ms. RMVT in SR: RMS40 = 59.7 +/- 49.0 microV; LAS = 28.3 +/- 8.5 ms; QRSD = 93.1 +/- 13.0 ms. MRVT during VT: RMS = 25.2 +/- 8.8 microV; LAS = 28.9 +/- 11.1 ms. RBBB: RMS = 53.3 +/- 34.2 microV; LAS = 22.6 +/- 9.8 ms. LBBB: RMS = 54.7 +/- 37.3 microV; LAS = 11.4 +/- 4.6 ms. The comparison between the data from SVT and MRVT/ABBB showed p < 0.01. In the studied population, the SAECG was able to identify abnormal LAS initiating SVT, that were not present in MRVT and ABBB. This signals probably represents intra-myocardial slow conduction, as a portion of a re-entry circuit. There was an excellent correlation between the findings during SVT and MRVT with those obtained in SR.
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_76950470</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>76950470</sourcerecordid><originalsourceid>FETCH-LOGICAL-p538-e40dcd3be5cf9e12ef006613f62c3a4007a4f34e6dbcdbb77b3785a6302c71723</originalsourceid><addsrcrecordid>eNotj01LxDAYhHNQ1nX1Jwg5eSukSZt0j7LoKix46cFbycebNpI2NWmE_feu2tPA8Mwwc4W2hHBeiIZ-3KDblD4JoVSweoM2F49T2mzRsR0Agwe9xKBlNC70UY44WDy4fsARUvB5cWHCJkc39fgbpiU6nb2MeJF6OP-l5B26ttInuF91h9qX5_bwWpzej2-Hp1Mx16wpoCJGG6ag1nYPJQX7u7BkllPNZEWIkJVlFXCjtFFKCMVEU0vOCNWiFJTt0ON_7RzDV4a0dKNLGryXE4ScOsH3NakEuYAPK5jVCKaboxtlPHfrcfYDY65Uqg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>76950470</pqid></control><display><type>article</type><title>The electrocardiogram of high resolution during ventricular tachycardia</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Maia, I G ; Cruz Filho, F ; Boghossian, S H ; Fagundes, M L ; Costa, A M ; Alves, P A</creator><creatorcontrib>Maia, I G ; Cruz Filho, F ; Boghossian, S H ; Fagundes, M L ; Costa, A M ; Alves, P A</creatorcontrib><description>To evaluate by the signal averaged-ECG (SAECG) the initial portion of the activation of the sustained ventricular tachycardia (SVT) and monomorphic repetitive ventricular tachycardia (MRVT), correlating the findings with those obtained during sinus rhythm (SR). Ten patients was studied; five with SVT and five with MRVT. Patients with SVT presented a positive SAECG while patients with MRVT the test was negative, during SR. The findings of this two populations were compared with those obtained in a group of ten patients with advanced bundle branch block (ABBB: five RBBB and five LBBB). We analyzed in the vector-magnitude obtained during VT and ABBB, the root mean square of the initial 40 ms portion of the activation (RMS40) and the duration of the low amplitude signals &lt; 40 microV from the beginning of the filtered QRS (LAS). To define the positiveness of the test in SR, we analyzed the final RMS40 (normal &gt; 20 microV), the duration of the LAS &lt; 40 microV at the end of the activation (normal &lt; 38 ms) and the total QRS duration (QRSD-normal &lt; 114 ms). (mean)-SVT in SR: RMS40 = 11.2 +/- 6.2 microV; LAS = 47.4 +/- 5.8 ms; QRSD = 131.2 +/- 8.7 ms. SVT during VT: RMS40 = 6.9 +/- 4.5 microV; LAS = 54.5 +/- 9.1 ms. RMVT in SR: RMS40 = 59.7 +/- 49.0 microV; LAS = 28.3 +/- 8.5 ms; QRSD = 93.1 +/- 13.0 ms. MRVT during VT: RMS = 25.2 +/- 8.8 microV; LAS = 28.9 +/- 11.1 ms. RBBB: RMS = 53.3 +/- 34.2 microV; LAS = 22.6 +/- 9.8 ms. LBBB: RMS = 54.7 +/- 37.3 microV; LAS = 11.4 +/- 4.6 ms. The comparison between the data from SVT and MRVT/ABBB showed p &lt; 0.01. In the studied population, the SAECG was able to identify abnormal LAS initiating SVT, that were not present in MRVT and ABBB. This signals probably represents intra-myocardial slow conduction, as a portion of a re-entry circuit. There was an excellent correlation between the findings during SVT and MRVT with those obtained in SR.</description><identifier>ISSN: 0066-782X</identifier><identifier>PMID: 7826228</identifier><language>por</language><publisher>Brazil</publisher><subject>Action Potentials - physiology ; Adolescent ; Adult ; Aged ; Electrocardiography - methods ; Female ; Humans ; Male ; Middle Aged ; Tachycardia, Ventricular - diagnosis ; Tachycardia, Ventricular - physiopathology</subject><ispartof>Arquivos brasileiros de cardiologia, 1994-06, Vol.62 (6), p.389-393</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7826228$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Maia, I G</creatorcontrib><creatorcontrib>Cruz Filho, F</creatorcontrib><creatorcontrib>Boghossian, S H</creatorcontrib><creatorcontrib>Fagundes, M L</creatorcontrib><creatorcontrib>Costa, A M</creatorcontrib><creatorcontrib>Alves, P A</creatorcontrib><title>The electrocardiogram of high resolution during ventricular tachycardia</title><title>Arquivos brasileiros de cardiologia</title><addtitle>Arq Bras Cardiol</addtitle><description>To evaluate by the signal averaged-ECG (SAECG) the initial portion of the activation of the sustained ventricular tachycardia (SVT) and monomorphic repetitive ventricular tachycardia (MRVT), correlating the findings with those obtained during sinus rhythm (SR). Ten patients was studied; five with SVT and five with MRVT. Patients with SVT presented a positive SAECG while patients with MRVT the test was negative, during SR. The findings of this two populations were compared with those obtained in a group of ten patients with advanced bundle branch block (ABBB: five RBBB and five LBBB). We analyzed in the vector-magnitude obtained during VT and ABBB, the root mean square of the initial 40 ms portion of the activation (RMS40) and the duration of the low amplitude signals &lt; 40 microV from the beginning of the filtered QRS (LAS). To define the positiveness of the test in SR, we analyzed the final RMS40 (normal &gt; 20 microV), the duration of the LAS &lt; 40 microV at the end of the activation (normal &lt; 38 ms) and the total QRS duration (QRSD-normal &lt; 114 ms). (mean)-SVT in SR: RMS40 = 11.2 +/- 6.2 microV; LAS = 47.4 +/- 5.8 ms; QRSD = 131.2 +/- 8.7 ms. SVT during VT: RMS40 = 6.9 +/- 4.5 microV; LAS = 54.5 +/- 9.1 ms. RMVT in SR: RMS40 = 59.7 +/- 49.0 microV; LAS = 28.3 +/- 8.5 ms; QRSD = 93.1 +/- 13.0 ms. MRVT during VT: RMS = 25.2 +/- 8.8 microV; LAS = 28.9 +/- 11.1 ms. RBBB: RMS = 53.3 +/- 34.2 microV; LAS = 22.6 +/- 9.8 ms. LBBB: RMS = 54.7 +/- 37.3 microV; LAS = 11.4 +/- 4.6 ms. The comparison between the data from SVT and MRVT/ABBB showed p &lt; 0.01. In the studied population, the SAECG was able to identify abnormal LAS initiating SVT, that were not present in MRVT and ABBB. This signals probably represents intra-myocardial slow conduction, as a portion of a re-entry circuit. There was an excellent correlation between the findings during SVT and MRVT with those obtained in SR.</description><subject>Action Potentials - physiology</subject><subject>Adolescent</subject><subject>Adult</subject><subject>Aged</subject><subject>Electrocardiography - methods</subject><subject>Female</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Tachycardia, Ventricular - diagnosis</subject><subject>Tachycardia, Ventricular - physiopathology</subject><issn>0066-782X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNotj01LxDAYhHNQ1nX1Jwg5eSukSZt0j7LoKix46cFbycebNpI2NWmE_feu2tPA8Mwwc4W2hHBeiIZ-3KDblD4JoVSweoM2F49T2mzRsR0Agwe9xKBlNC70UY44WDy4fsARUvB5cWHCJkc39fgbpiU6nb2MeJF6OP-l5B26ttInuF91h9qX5_bwWpzej2-Hp1Mx16wpoCJGG6ag1nYPJQX7u7BkllPNZEWIkJVlFXCjtFFKCMVEU0vOCNWiFJTt0ON_7RzDV4a0dKNLGryXE4ScOsH3NakEuYAPK5jVCKaboxtlPHfrcfYDY65Uqg</recordid><startdate>199406</startdate><enddate>199406</enddate><creator>Maia, I G</creator><creator>Cruz Filho, F</creator><creator>Boghossian, S H</creator><creator>Fagundes, M L</creator><creator>Costa, A M</creator><creator>Alves, P A</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>199406</creationdate><title>The electrocardiogram of high resolution during ventricular tachycardia</title><author>Maia, I G ; Cruz Filho, F ; Boghossian, S H ; Fagundes, M L ; Costa, A M ; Alves, P A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p538-e40dcd3be5cf9e12ef006613f62c3a4007a4f34e6dbcdbb77b3785a6302c71723</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>por</language><creationdate>1994</creationdate><topic>Action Potentials - physiology</topic><topic>Adolescent</topic><topic>Adult</topic><topic>Aged</topic><topic>Electrocardiography - methods</topic><topic>Female</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Tachycardia, Ventricular - diagnosis</topic><topic>Tachycardia, Ventricular - physiopathology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Maia, I G</creatorcontrib><creatorcontrib>Cruz Filho, F</creatorcontrib><creatorcontrib>Boghossian, S H</creatorcontrib><creatorcontrib>Fagundes, M L</creatorcontrib><creatorcontrib>Costa, A M</creatorcontrib><creatorcontrib>Alves, P A</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Arquivos brasileiros de cardiologia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Maia, I G</au><au>Cruz Filho, F</au><au>Boghossian, S H</au><au>Fagundes, M L</au><au>Costa, A M</au><au>Alves, P A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The electrocardiogram of high resolution during ventricular tachycardia</atitle><jtitle>Arquivos brasileiros de cardiologia</jtitle><addtitle>Arq Bras Cardiol</addtitle><date>1994-06</date><risdate>1994</risdate><volume>62</volume><issue>6</issue><spage>389</spage><epage>393</epage><pages>389-393</pages><issn>0066-782X</issn><abstract>To evaluate by the signal averaged-ECG (SAECG) the initial portion of the activation of the sustained ventricular tachycardia (SVT) and monomorphic repetitive ventricular tachycardia (MRVT), correlating the findings with those obtained during sinus rhythm (SR). Ten patients was studied; five with SVT and five with MRVT. Patients with SVT presented a positive SAECG while patients with MRVT the test was negative, during SR. The findings of this two populations were compared with those obtained in a group of ten patients with advanced bundle branch block (ABBB: five RBBB and five LBBB). We analyzed in the vector-magnitude obtained during VT and ABBB, the root mean square of the initial 40 ms portion of the activation (RMS40) and the duration of the low amplitude signals &lt; 40 microV from the beginning of the filtered QRS (LAS). To define the positiveness of the test in SR, we analyzed the final RMS40 (normal &gt; 20 microV), the duration of the LAS &lt; 40 microV at the end of the activation (normal &lt; 38 ms) and the total QRS duration (QRSD-normal &lt; 114 ms). (mean)-SVT in SR: RMS40 = 11.2 +/- 6.2 microV; LAS = 47.4 +/- 5.8 ms; QRSD = 131.2 +/- 8.7 ms. SVT during VT: RMS40 = 6.9 +/- 4.5 microV; LAS = 54.5 +/- 9.1 ms. RMVT in SR: RMS40 = 59.7 +/- 49.0 microV; LAS = 28.3 +/- 8.5 ms; QRSD = 93.1 +/- 13.0 ms. MRVT during VT: RMS = 25.2 +/- 8.8 microV; LAS = 28.9 +/- 11.1 ms. RBBB: RMS = 53.3 +/- 34.2 microV; LAS = 22.6 +/- 9.8 ms. LBBB: RMS = 54.7 +/- 37.3 microV; LAS = 11.4 +/- 4.6 ms. The comparison between the data from SVT and MRVT/ABBB showed p &lt; 0.01. In the studied population, the SAECG was able to identify abnormal LAS initiating SVT, that were not present in MRVT and ABBB. This signals probably represents intra-myocardial slow conduction, as a portion of a re-entry circuit. There was an excellent correlation between the findings during SVT and MRVT with those obtained in SR.</abstract><cop>Brazil</cop><pmid>7826228</pmid><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0066-782X
ispartof Arquivos brasileiros de cardiologia, 1994-06, Vol.62 (6), p.389-393
issn 0066-782X
language por
recordid cdi_proquest_miscellaneous_76950470
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Action Potentials - physiology
Adolescent
Adult
Aged
Electrocardiography - methods
Female
Humans
Male
Middle Aged
Tachycardia, Ventricular - diagnosis
Tachycardia, Ventricular - physiopathology
title The electrocardiogram of high resolution during ventricular tachycardia
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T03%3A59%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20electrocardiogram%20of%20high%20resolution%20during%20ventricular%20tachycardia&rft.jtitle=Arquivos%20brasileiros%20de%20cardiologia&rft.au=Maia,%20I%20G&rft.date=1994-06&rft.volume=62&rft.issue=6&rft.spage=389&rft.epage=393&rft.pages=389-393&rft.issn=0066-782X&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E76950470%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=76950470&rft_id=info:pmid/7826228&rfr_iscdi=true