The muscle twitch monitor: a rapid unequivocal method of monitoring free muscle transfers
A free latissimus dorsi muscle transfer, which required anastomotic revision on two occasions within twenty-four hours of operation, illustrates how the change in response of electrically induced muscle contraction to ischaemia can be used as a rapid and sensitive method of monitoring free muscle tr...
Gespeichert in:
Veröffentlicht in: | British journal of plastic surgery 1986-07, Vol.39 (3), p.356-360 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A free latissimus dorsi muscle transfer, which required anastomotic revision on two occasions within twenty-four hours of operation, illustrates how the change in response of electrically induced muscle contraction to ischaemia can be used as a rapid and sensitive method of monitoring free muscle transfers. It is a response that has the great merit of being easily recognised by untrained observers because it relies on an absolute rather than a relative change in the measured modality. Furthermore it is not influenced by the clinical condition of the patient or by changes in the flap's environment. Its potential is discussed. |
---|---|
ISSN: | 0007-1226 1465-3087 |
DOI: | 10.1016/0007-1226(86)90047-0 |