In vivo experimental analysis of silicone implants used with titanium grommets
This study evaluated the titanium grommets recommended to reduce breakage by protecting hinge implants from bone edges. Silastic HP-100 (Dow Corning Wright, Arlington, TN) flexible finger implants (size 5) were used to replace one knee of 10 rabbits, and implants plus titanium grommets were used in...
Gespeichert in:
Veröffentlicht in: | The Journal of hand surgery (American ed.) 1994-07, Vol.19 (4), p.567-574 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 574 |
---|---|
container_issue | 4 |
container_start_page | 567 |
container_title | The Journal of hand surgery (American ed.) |
container_volume | 19 |
creator | Minamikawa, Yoshitaka Peimer, Clayton A. Ogawa, Ryokei Fujimoto, Keji Sherwin, Frances S. Howard, Craig |
description | This study evaluated the titanium grommets recommended to reduce breakage by protecting hinge implants from bone edges. Silastic HP-100 (Dow Corning Wright, Arlington, TN) flexible finger implants (size 5) were used to replace one knee of 10 rabbits, and implants plus titanium grommets were used in another 10. X-ray films were taken monthly; deaths from each group were 1 animal at 2 and 4 months, 2 animals at 6, and 3 each at 12 and 16 months. X-ray films revealed that 4 of 10 implants from each group had fractured. Silicone fractures occurred identically at the proximal stem-hinge junction in both groups, destruction was always most pronounced at the dorsal surface of the proximal stems. The time from surgery to x-ray film evidence of implant fracture without grommets was an average of 9 months and with grommets 13 months. Although grommets delayed x-ray film evidence of fracture onset, after 14 months all implants in both groups of animals fractured. These findings do not support the hypothesis that grommets prevent silicone hinge implant wear or fracture in this experimental model. |
doi_str_mv | 10.1016/0363-5023(94)90258-5 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_76810626</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0363502394902585</els_id><sourcerecordid>76810626</sourcerecordid><originalsourceid>FETCH-LOGICAL-c386t-77961c9b8f481eccf928c8b01f84aa1221dd986d4dfca1d4c70e6e4efe33f8b83</originalsourceid><addsrcrecordid>eNp9kEtPGzEURq2qKA3Qf9BKXlQIFgP22ON4NpUqxEtCdFPWlmNft67mkfp6Avn3OE2UJau7uOe7j0PIF84uOePqigklqobV4ryVFy2rG101H8icN4JXqlHyI5kfkE_kGPEvYyUnmhmZLVolBGvn5OlhoOu4Him8riDFHoZsO2oH220wIh0DxdhFNw5AY7_q7JCRTgievsT8h-aY7RCnnv5OY99DxlNyFGyH8HlfT8jz7c2v6_vq8efdw_WPx8oJrXK1KPu5a5c6SM3BudDW2ukl40FLa3ldc-9brbz0wVnupVswUCAhgBBBL7U4IWe7uas0_psAs-kjOujKgTBOaBZKc6ZqVUC5A10aERMEsypf2rQxnJmtRrN1ZLaOTCvNf42mKbGv-_nTsgd_CO29lf63fd-is11IdnARD5hoFOeqLtj3HQbFxTpCMugiDA58TOCy8WN8_443qcOPcg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>76810626</pqid></control><display><type>article</type><title>In vivo experimental analysis of silicone implants used with titanium grommets</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Minamikawa, Yoshitaka ; Peimer, Clayton A. ; Ogawa, Ryokei ; Fujimoto, Keji ; Sherwin, Frances S. ; Howard, Craig</creator><creatorcontrib>Minamikawa, Yoshitaka ; Peimer, Clayton A. ; Ogawa, Ryokei ; Fujimoto, Keji ; Sherwin, Frances S. ; Howard, Craig</creatorcontrib><description>This study evaluated the titanium grommets recommended to reduce breakage by protecting hinge implants from bone edges. Silastic HP-100 (Dow Corning Wright, Arlington, TN) flexible finger implants (size 5) were used to replace one knee of 10 rabbits, and implants plus titanium grommets were used in another 10. X-ray films were taken monthly; deaths from each group were 1 animal at 2 and 4 months, 2 animals at 6, and 3 each at 12 and 16 months. X-ray films revealed that 4 of 10 implants from each group had fractured. Silicone fractures occurred identically at the proximal stem-hinge junction in both groups, destruction was always most pronounced at the dorsal surface of the proximal stems. The time from surgery to x-ray film evidence of implant fracture without grommets was an average of 9 months and with grommets 13 months. Although grommets delayed x-ray film evidence of fracture onset, after 14 months all implants in both groups of animals fractured. These findings do not support the hypothesis that grommets prevent silicone hinge implant wear or fracture in this experimental model.</description><identifier>ISSN: 0363-5023</identifier><identifier>EISSN: 1531-6564</identifier><identifier>DOI: 10.1016/0363-5023(94)90258-5</identifier><identifier>PMID: 7963309</identifier><identifier>CODEN: JHSUDV</identifier><language>eng</language><publisher>New york, NY: Elsevier Inc</publisher><subject>Animals ; Biological and medical sciences ; Joint Prosthesis ; Knee Joint ; Medical sciences ; Orthopedic surgery ; Prosthesis Design ; Prosthesis Failure ; Rabbits ; Silicone Elastomers ; Silicones ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Titanium</subject><ispartof>The Journal of hand surgery (American ed.), 1994-07, Vol.19 (4), p.567-574</ispartof><rights>1994</rights><rights>1995 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c386t-77961c9b8f481eccf928c8b01f84aa1221dd986d4dfca1d4c70e6e4efe33f8b83</citedby><cites>FETCH-LOGICAL-c386t-77961c9b8f481eccf928c8b01f84aa1221dd986d4dfca1d4c70e6e4efe33f8b83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/0363-5023(94)90258-5$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=3561162$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7963309$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Minamikawa, Yoshitaka</creatorcontrib><creatorcontrib>Peimer, Clayton A.</creatorcontrib><creatorcontrib>Ogawa, Ryokei</creatorcontrib><creatorcontrib>Fujimoto, Keji</creatorcontrib><creatorcontrib>Sherwin, Frances S.</creatorcontrib><creatorcontrib>Howard, Craig</creatorcontrib><title>In vivo experimental analysis of silicone implants used with titanium grommets</title><title>The Journal of hand surgery (American ed.)</title><addtitle>J Hand Surg Am</addtitle><description>This study evaluated the titanium grommets recommended to reduce breakage by protecting hinge implants from bone edges. Silastic HP-100 (Dow Corning Wright, Arlington, TN) flexible finger implants (size 5) were used to replace one knee of 10 rabbits, and implants plus titanium grommets were used in another 10. X-ray films were taken monthly; deaths from each group were 1 animal at 2 and 4 months, 2 animals at 6, and 3 each at 12 and 16 months. X-ray films revealed that 4 of 10 implants from each group had fractured. Silicone fractures occurred identically at the proximal stem-hinge junction in both groups, destruction was always most pronounced at the dorsal surface of the proximal stems. The time from surgery to x-ray film evidence of implant fracture without grommets was an average of 9 months and with grommets 13 months. Although grommets delayed x-ray film evidence of fracture onset, after 14 months all implants in both groups of animals fractured. These findings do not support the hypothesis that grommets prevent silicone hinge implant wear or fracture in this experimental model.</description><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Joint Prosthesis</subject><subject>Knee Joint</subject><subject>Medical sciences</subject><subject>Orthopedic surgery</subject><subject>Prosthesis Design</subject><subject>Prosthesis Failure</subject><subject>Rabbits</subject><subject>Silicone Elastomers</subject><subject>Silicones</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Titanium</subject><issn>0363-5023</issn><issn>1531-6564</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kEtPGzEURq2qKA3Qf9BKXlQIFgP22ON4NpUqxEtCdFPWlmNft67mkfp6Avn3OE2UJau7uOe7j0PIF84uOePqigklqobV4ryVFy2rG101H8icN4JXqlHyI5kfkE_kGPEvYyUnmhmZLVolBGvn5OlhoOu4Him8riDFHoZsO2oH220wIh0DxdhFNw5AY7_q7JCRTgievsT8h-aY7RCnnv5OY99DxlNyFGyH8HlfT8jz7c2v6_vq8efdw_WPx8oJrXK1KPu5a5c6SM3BudDW2ukl40FLa3ldc-9brbz0wVnupVswUCAhgBBBL7U4IWe7uas0_psAs-kjOujKgTBOaBZKc6ZqVUC5A10aERMEsypf2rQxnJmtRrN1ZLaOTCvNf42mKbGv-_nTsgd_CO29lf63fd-is11IdnARD5hoFOeqLtj3HQbFxTpCMugiDA58TOCy8WN8_443qcOPcg</recordid><startdate>19940701</startdate><enddate>19940701</enddate><creator>Minamikawa, Yoshitaka</creator><creator>Peimer, Clayton A.</creator><creator>Ogawa, Ryokei</creator><creator>Fujimoto, Keji</creator><creator>Sherwin, Frances S.</creator><creator>Howard, Craig</creator><general>Elsevier Inc</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19940701</creationdate><title>In vivo experimental analysis of silicone implants used with titanium grommets</title><author>Minamikawa, Yoshitaka ; Peimer, Clayton A. ; Ogawa, Ryokei ; Fujimoto, Keji ; Sherwin, Frances S. ; Howard, Craig</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c386t-77961c9b8f481eccf928c8b01f84aa1221dd986d4dfca1d4c70e6e4efe33f8b83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Joint Prosthesis</topic><topic>Knee Joint</topic><topic>Medical sciences</topic><topic>Orthopedic surgery</topic><topic>Prosthesis Design</topic><topic>Prosthesis Failure</topic><topic>Rabbits</topic><topic>Silicone Elastomers</topic><topic>Silicones</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Titanium</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Minamikawa, Yoshitaka</creatorcontrib><creatorcontrib>Peimer, Clayton A.</creatorcontrib><creatorcontrib>Ogawa, Ryokei</creatorcontrib><creatorcontrib>Fujimoto, Keji</creatorcontrib><creatorcontrib>Sherwin, Frances S.</creatorcontrib><creatorcontrib>Howard, Craig</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of hand surgery (American ed.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Minamikawa, Yoshitaka</au><au>Peimer, Clayton A.</au><au>Ogawa, Ryokei</au><au>Fujimoto, Keji</au><au>Sherwin, Frances S.</au><au>Howard, Craig</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>In vivo experimental analysis of silicone implants used with titanium grommets</atitle><jtitle>The Journal of hand surgery (American ed.)</jtitle><addtitle>J Hand Surg Am</addtitle><date>1994-07-01</date><risdate>1994</risdate><volume>19</volume><issue>4</issue><spage>567</spage><epage>574</epage><pages>567-574</pages><issn>0363-5023</issn><eissn>1531-6564</eissn><coden>JHSUDV</coden><abstract>This study evaluated the titanium grommets recommended to reduce breakage by protecting hinge implants from bone edges. Silastic HP-100 (Dow Corning Wright, Arlington, TN) flexible finger implants (size 5) were used to replace one knee of 10 rabbits, and implants plus titanium grommets were used in another 10. X-ray films were taken monthly; deaths from each group were 1 animal at 2 and 4 months, 2 animals at 6, and 3 each at 12 and 16 months. X-ray films revealed that 4 of 10 implants from each group had fractured. Silicone fractures occurred identically at the proximal stem-hinge junction in both groups, destruction was always most pronounced at the dorsal surface of the proximal stems. The time from surgery to x-ray film evidence of implant fracture without grommets was an average of 9 months and with grommets 13 months. Although grommets delayed x-ray film evidence of fracture onset, after 14 months all implants in both groups of animals fractured. These findings do not support the hypothesis that grommets prevent silicone hinge implant wear or fracture in this experimental model.</abstract><cop>New york, NY</cop><pub>Elsevier Inc</pub><pmid>7963309</pmid><doi>10.1016/0363-5023(94)90258-5</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0363-5023 |
ispartof | The Journal of hand surgery (American ed.), 1994-07, Vol.19 (4), p.567-574 |
issn | 0363-5023 1531-6564 |
language | eng |
recordid | cdi_proquest_miscellaneous_76810626 |
source | MEDLINE; Elsevier ScienceDirect Journals Complete |
subjects | Animals Biological and medical sciences Joint Prosthesis Knee Joint Medical sciences Orthopedic surgery Prosthesis Design Prosthesis Failure Rabbits Silicone Elastomers Silicones Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases Titanium |
title | In vivo experimental analysis of silicone implants used with titanium grommets |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T14%3A43%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=In%20vivo%20experimental%20analysis%20of%20silicone%20implants%20used%20with%20titanium%20grommets&rft.jtitle=The%20Journal%20of%20hand%20surgery%20(American%20ed.)&rft.au=Minamikawa,%20Yoshitaka&rft.date=1994-07-01&rft.volume=19&rft.issue=4&rft.spage=567&rft.epage=574&rft.pages=567-574&rft.issn=0363-5023&rft.eissn=1531-6564&rft.coden=JHSUDV&rft_id=info:doi/10.1016/0363-5023(94)90258-5&rft_dat=%3Cproquest_cross%3E76810626%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=76810626&rft_id=info:pmid/7963309&rft_els_id=0363502394902585&rfr_iscdi=true |