Decreased minimum alveolar concentration of isoflurane in pregnant humans

Minimum alveolar concentration (MAC) is decreased in pregnant animals, but this change has not been demonstrated in humans, probably because of ethical considerations. It is less problematic to determine MAC in pregnant women undergoing termination of pregnancy, however, and therefore we compared th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Anesthesiology (Philadelphia) 1994-10, Vol.81 (4), p.829-832
Hauptverfasser: Gin, T, Chan, M T
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 832
container_issue 4
container_start_page 829
container_title Anesthesiology (Philadelphia)
container_volume 81
creator Gin, T
Chan, M T
description Minimum alveolar concentration (MAC) is decreased in pregnant animals, but this change has not been demonstrated in humans, probably because of ethical considerations. It is less problematic to determine MAC in pregnant women undergoing termination of pregnancy, however, and therefore we compared the MAC of isoflurane in these women with the MAC in matched nonpregnant women. Patients underwent inhalational induction of anesthesia with isoflurane and tracheal intubation. MAC was determined in each patient by testing the response to a 10-s, 50-Hz, 80-mA transcutaneous tetanic electrical stimulus to the ulnar nerve at varying concentrations of isoflurane. The end-tidal concentration of isoflurane was kept constant for 10 min before each stimulus and the concentration of isoflurane ultimately varied in steps of 0.05% until we obtained a sequence of three alternate responses (move, not move, move) or (not move, move, not move). MAC for each patient was taken as the mean of the two concentrations just permitting and just preventing movement. MAC for the group was taken as the median of the individual MAC values. A blood sample was taken immediately before induction of anesthesia for measurement of progesterone concentrations. Data were compared between groups by the Mann-Whitney test. The median (range) MAC for isoflurane in the pregnant group, 0.775% (0.675-0.825), was less than that in the nonpregnant group, 1.075% (1.025-1.175) (P < 0.001). The median (range) plasma progesterone concentration in the pregnant group, 63.4 (0.8-106) nM, was greater than that in the nonpregnant group, 8.4 (0.7-66) nM (P < 0.02). The MAC of isoflurane was reduced by 28% in pregnant women at 8-12 weeks' gestation compared with that of nonpregnant controls.
doi_str_mv 10.1097/00000542-199410000-00009
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_76778586</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>76778586</sourcerecordid><originalsourceid>FETCH-LOGICAL-c360t-61a0c73f9296ecfe701ff99d1599cc8f3a4c1ad93fa12bd35c8c760d900c938f3</originalsourceid><addsrcrecordid>eNo9UE1PwzAMzQE0xuAnIOXErZA0bRMf0fiaNIkLnKMsTSCoSUbSIvHvaVmZD356tp9tPYQwJTeUAL8lU9RVWVCAik6kmBKcoOUIrGCkLM_Qec6fI-U1Ewu04FAxwdgSbe6NTkZl02LvgvODx6r7NrFTCesYtAl9Ur2LAUeLXY62G5IKBruA98m8BxV6_DF4FfIFOrWqy-ZyxhV6e3x4XT8X25enzfpuW2jWkL5oqCKaMwslNEZbwwm1FqClNYDWwjJVaapaYFbRcteyWgvNG9ICIRrY2F-h68PefYpfg8m99C5r03XjW3HIkjeci1o046A4DOoUc07Gyn1yXqUfSYmcnJP_zsmjc38lGKVX841h5017FM62sV_RImws</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>76778586</pqid></control><display><type>article</type><title>Decreased minimum alveolar concentration of isoflurane in pregnant humans</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Journals@Ovid Complete</source><creator>Gin, T ; Chan, M T</creator><creatorcontrib>Gin, T ; Chan, M T</creatorcontrib><description>Minimum alveolar concentration (MAC) is decreased in pregnant animals, but this change has not been demonstrated in humans, probably because of ethical considerations. It is less problematic to determine MAC in pregnant women undergoing termination of pregnancy, however, and therefore we compared the MAC of isoflurane in these women with the MAC in matched nonpregnant women. Patients underwent inhalational induction of anesthesia with isoflurane and tracheal intubation. MAC was determined in each patient by testing the response to a 10-s, 50-Hz, 80-mA transcutaneous tetanic electrical stimulus to the ulnar nerve at varying concentrations of isoflurane. The end-tidal concentration of isoflurane was kept constant for 10 min before each stimulus and the concentration of isoflurane ultimately varied in steps of 0.05% until we obtained a sequence of three alternate responses (move, not move, move) or (not move, move, not move). MAC for each patient was taken as the mean of the two concentrations just permitting and just preventing movement. MAC for the group was taken as the median of the individual MAC values. A blood sample was taken immediately before induction of anesthesia for measurement of progesterone concentrations. Data were compared between groups by the Mann-Whitney test. The median (range) MAC for isoflurane in the pregnant group, 0.775% (0.675-0.825), was less than that in the nonpregnant group, 1.075% (1.025-1.175) (P &lt; 0.001). The median (range) plasma progesterone concentration in the pregnant group, 63.4 (0.8-106) nM, was greater than that in the nonpregnant group, 8.4 (0.7-66) nM (P &lt; 0.02). The MAC of isoflurane was reduced by 28% in pregnant women at 8-12 weeks' gestation compared with that of nonpregnant controls.</description><identifier>ISSN: 0003-3022</identifier><identifier>DOI: 10.1097/00000542-199410000-00009</identifier><identifier>PMID: 7943833</identifier><language>eng</language><publisher>United States</publisher><subject>Anesthesia, Inhalation ; Double-Blind Method ; Female ; Gynecology ; Humans ; Isoflurane - administration &amp; dosage ; Isoflurane - analysis ; Isoflurane - pharmacology ; Pregnancy ; Pregnancy Trimester, First - drug effects ; Progesterone - blood ; Pulmonary Alveoli - chemistry</subject><ispartof>Anesthesiology (Philadelphia), 1994-10, Vol.81 (4), p.829-832</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c360t-61a0c73f9296ecfe701ff99d1599cc8f3a4c1ad93fa12bd35c8c760d900c938f3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7943833$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gin, T</creatorcontrib><creatorcontrib>Chan, M T</creatorcontrib><title>Decreased minimum alveolar concentration of isoflurane in pregnant humans</title><title>Anesthesiology (Philadelphia)</title><addtitle>Anesthesiology</addtitle><description>Minimum alveolar concentration (MAC) is decreased in pregnant animals, but this change has not been demonstrated in humans, probably because of ethical considerations. It is less problematic to determine MAC in pregnant women undergoing termination of pregnancy, however, and therefore we compared the MAC of isoflurane in these women with the MAC in matched nonpregnant women. Patients underwent inhalational induction of anesthesia with isoflurane and tracheal intubation. MAC was determined in each patient by testing the response to a 10-s, 50-Hz, 80-mA transcutaneous tetanic electrical stimulus to the ulnar nerve at varying concentrations of isoflurane. The end-tidal concentration of isoflurane was kept constant for 10 min before each stimulus and the concentration of isoflurane ultimately varied in steps of 0.05% until we obtained a sequence of three alternate responses (move, not move, move) or (not move, move, not move). MAC for each patient was taken as the mean of the two concentrations just permitting and just preventing movement. MAC for the group was taken as the median of the individual MAC values. A blood sample was taken immediately before induction of anesthesia for measurement of progesterone concentrations. Data were compared between groups by the Mann-Whitney test. The median (range) MAC for isoflurane in the pregnant group, 0.775% (0.675-0.825), was less than that in the nonpregnant group, 1.075% (1.025-1.175) (P &lt; 0.001). The median (range) plasma progesterone concentration in the pregnant group, 63.4 (0.8-106) nM, was greater than that in the nonpregnant group, 8.4 (0.7-66) nM (P &lt; 0.02). The MAC of isoflurane was reduced by 28% in pregnant women at 8-12 weeks' gestation compared with that of nonpregnant controls.</description><subject>Anesthesia, Inhalation</subject><subject>Double-Blind Method</subject><subject>Female</subject><subject>Gynecology</subject><subject>Humans</subject><subject>Isoflurane - administration &amp; dosage</subject><subject>Isoflurane - analysis</subject><subject>Isoflurane - pharmacology</subject><subject>Pregnancy</subject><subject>Pregnancy Trimester, First - drug effects</subject><subject>Progesterone - blood</subject><subject>Pulmonary Alveoli - chemistry</subject><issn>0003-3022</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9UE1PwzAMzQE0xuAnIOXErZA0bRMf0fiaNIkLnKMsTSCoSUbSIvHvaVmZD356tp9tPYQwJTeUAL8lU9RVWVCAik6kmBKcoOUIrGCkLM_Qec6fI-U1Ewu04FAxwdgSbe6NTkZl02LvgvODx6r7NrFTCesYtAl9Ur2LAUeLXY62G5IKBruA98m8BxV6_DF4FfIFOrWqy-ZyxhV6e3x4XT8X25enzfpuW2jWkL5oqCKaMwslNEZbwwm1FqClNYDWwjJVaapaYFbRcteyWgvNG9ICIRrY2F-h68PefYpfg8m99C5r03XjW3HIkjeci1o046A4DOoUc07Gyn1yXqUfSYmcnJP_zsmjc38lGKVX841h5017FM62sV_RImws</recordid><startdate>19941001</startdate><enddate>19941001</enddate><creator>Gin, T</creator><creator>Chan, M T</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19941001</creationdate><title>Decreased minimum alveolar concentration of isoflurane in pregnant humans</title><author>Gin, T ; Chan, M T</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c360t-61a0c73f9296ecfe701ff99d1599cc8f3a4c1ad93fa12bd35c8c760d900c938f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Anesthesia, Inhalation</topic><topic>Double-Blind Method</topic><topic>Female</topic><topic>Gynecology</topic><topic>Humans</topic><topic>Isoflurane - administration &amp; dosage</topic><topic>Isoflurane - analysis</topic><topic>Isoflurane - pharmacology</topic><topic>Pregnancy</topic><topic>Pregnancy Trimester, First - drug effects</topic><topic>Progesterone - blood</topic><topic>Pulmonary Alveoli - chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gin, T</creatorcontrib><creatorcontrib>Chan, M T</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Anesthesiology (Philadelphia)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gin, T</au><au>Chan, M T</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Decreased minimum alveolar concentration of isoflurane in pregnant humans</atitle><jtitle>Anesthesiology (Philadelphia)</jtitle><addtitle>Anesthesiology</addtitle><date>1994-10-01</date><risdate>1994</risdate><volume>81</volume><issue>4</issue><spage>829</spage><epage>832</epage><pages>829-832</pages><issn>0003-3022</issn><abstract>Minimum alveolar concentration (MAC) is decreased in pregnant animals, but this change has not been demonstrated in humans, probably because of ethical considerations. It is less problematic to determine MAC in pregnant women undergoing termination of pregnancy, however, and therefore we compared the MAC of isoflurane in these women with the MAC in matched nonpregnant women. Patients underwent inhalational induction of anesthesia with isoflurane and tracheal intubation. MAC was determined in each patient by testing the response to a 10-s, 50-Hz, 80-mA transcutaneous tetanic electrical stimulus to the ulnar nerve at varying concentrations of isoflurane. The end-tidal concentration of isoflurane was kept constant for 10 min before each stimulus and the concentration of isoflurane ultimately varied in steps of 0.05% until we obtained a sequence of three alternate responses (move, not move, move) or (not move, move, not move). MAC for each patient was taken as the mean of the two concentrations just permitting and just preventing movement. MAC for the group was taken as the median of the individual MAC values. A blood sample was taken immediately before induction of anesthesia for measurement of progesterone concentrations. Data were compared between groups by the Mann-Whitney test. The median (range) MAC for isoflurane in the pregnant group, 0.775% (0.675-0.825), was less than that in the nonpregnant group, 1.075% (1.025-1.175) (P &lt; 0.001). The median (range) plasma progesterone concentration in the pregnant group, 63.4 (0.8-106) nM, was greater than that in the nonpregnant group, 8.4 (0.7-66) nM (P &lt; 0.02). The MAC of isoflurane was reduced by 28% in pregnant women at 8-12 weeks' gestation compared with that of nonpregnant controls.</abstract><cop>United States</cop><pmid>7943833</pmid><doi>10.1097/00000542-199410000-00009</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0003-3022
ispartof Anesthesiology (Philadelphia), 1994-10, Vol.81 (4), p.829-832
issn 0003-3022
language eng
recordid cdi_proquest_miscellaneous_76778586
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Journals@Ovid Complete
subjects Anesthesia, Inhalation
Double-Blind Method
Female
Gynecology
Humans
Isoflurane - administration & dosage
Isoflurane - analysis
Isoflurane - pharmacology
Pregnancy
Pregnancy Trimester, First - drug effects
Progesterone - blood
Pulmonary Alveoli - chemistry
title Decreased minimum alveolar concentration of isoflurane in pregnant humans
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T17%3A11%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Decreased%20minimum%20alveolar%20concentration%20of%20isoflurane%20in%20pregnant%20humans&rft.jtitle=Anesthesiology%20(Philadelphia)&rft.au=Gin,%20T&rft.date=1994-10-01&rft.volume=81&rft.issue=4&rft.spage=829&rft.epage=832&rft.pages=829-832&rft.issn=0003-3022&rft_id=info:doi/10.1097/00000542-199410000-00009&rft_dat=%3Cproquest_cross%3E76778586%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=76778586&rft_id=info:pmid/7943833&rfr_iscdi=true