The tetrad and hexad: Maximum beam separation as a starting point for noncoplanar 3D treatment planning: Prostate cancer as a test case

Purpose : In contrast to computer optimized three-dimensional (3D) treatment planning, we have used maximally separated, noncoplanar beams as the starting point for 3D treatment planning of prostate cancer to maximize the rate of dose fall off from the target volume and minimize dose to surrounding...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of radiation oncology, biology, physics biology, physics, 1994-09, Vol.30 (2), p.439-446
Hauptverfasser: Sailer, Scott L., Rosenman, Julian G., Symon, James R., Cullip, Timothy J., Chaney, Edward L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 446
container_issue 2
container_start_page 439
container_title International journal of radiation oncology, biology, physics
container_volume 30
creator Sailer, Scott L.
Rosenman, Julian G.
Symon, James R.
Cullip, Timothy J.
Chaney, Edward L.
description Purpose : In contrast to computer optimized three-dimensional (3D) treatment planning, we have used maximally separated, noncoplanar beams as the starting point for 3D treatment planning of prostate cancer to maximize the rate of dose fall off from the target volume and minimize dose to surrounding tissues. Materials and Methods : A planar four-field plan, a planar six-field plan, a tetrad plan, and a hexad plan are analyzed using a 3D treatment planning system which is capable of displaying real-time 3D dose distributions within volume reconstructed data sets (VISTAnet—an extension of the virtual simulator). The tetrad plan is based on the methane molecule and the hexad plan has a minimum separation of 58° on beam entrance. All fields are conformal. The irradiated volume equals the clinical target volume plus a 1 cm margin. Competing plans are compared using cumulative dose-volume histograms and normal tissue complication probabilities. Results : The crossover point, the isodose surface that conforms more to the beams than the target, is introduced and described. The hexad and tetrad plans result in tighter dose distributions when compared to the planar plans with the same number of beams. The tetrad plan treats a volume less than or equal to the planar six-field plan at isodose surfaces above 18% except between 37% and 44% where the tetrad volume is slightly larger. As expected from integral dose considerations, the amount of normal tissue receiving some radiation increases, but the amount receiving clinically significant amounts of radiation decreases as the number of beams increase. The plan involving the largest number of noncoplanar beams results in the tightest isodose distribution. Analysis of rectal and bladder cumulative dose volume histograms does not reveal a clearly superior plan based on normal tissue complication probabilities. Conclusions : Using basic principles of solid geometry, maximally separated beams without significant overlap on exit or entrance can be designed which minimize clinically significant dose to surrounding tissues and tighten the isodose distribution around the target volume. The emphasis of this treatment plan optimization is geometric in contrast to methods using computer optimization or artificial intelligence.
doi_str_mv 10.1016/0360-3016(94)90026-4
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_76745927</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0360301694900264</els_id><sourcerecordid>76745927</sourcerecordid><originalsourceid>FETCH-LOGICAL-c386t-a831addbdfb3978ed7b859083d05744d5823f981ae28591309b5aaa9131048873</originalsourceid><addsrcrecordid>eNp9kM9u1DAQxi0EKkvhDUDyAaFyCNixE9s9IKHyVyqCQ5G4WRN7Qo02TrC9VXkCXhunu9ojpxnNfN83ox8hTzl7xRnvXzPRs0bU7szIl4axtm_kPbLhWplGdN2P-2RzlDwkj3L-xRjjXMkTcqJMq6XiG_L36hppwZLAU4ieXuMt-HP6BW7DtJvogDDRjAskKGGOFDIFmgukEuJPuswhFjrOicY5unnZQoRExTtaEkKZsC7XWazac_otzdVYkDqIDtM-qmAudZDxMXkwwjbjk0M9Jd8_vL-6-NRcfv34-eLtZeOE7ksDWnDwfvDjIIzS6NWgO8O08KxTUvpOt2I0mgO2dc4FM0MHALXjTGqtxCl5sc9d0vx7V6_bKWSH2_omzrtsVa9kZ9pVKPdCV__OCUe7pDBB-mM5syt_u8K1K1xrpL3jb2W1PTvk74YJ_dF0AF73zw97yA62Y6owQj7KhGBM3l1_s5dhZXETMNnsAlZuPiR0xfo5_P-Pf7DpoWw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>76745927</pqid></control><display><type>article</type><title>The tetrad and hexad: Maximum beam separation as a starting point for noncoplanar 3D treatment planning: Prostate cancer as a test case</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Sailer, Scott L. ; Rosenman, Julian G. ; Symon, James R. ; Cullip, Timothy J. ; Chaney, Edward L.</creator><creatorcontrib>Sailer, Scott L. ; Rosenman, Julian G. ; Symon, James R. ; Cullip, Timothy J. ; Chaney, Edward L.</creatorcontrib><description>Purpose : In contrast to computer optimized three-dimensional (3D) treatment planning, we have used maximally separated, noncoplanar beams as the starting point for 3D treatment planning of prostate cancer to maximize the rate of dose fall off from the target volume and minimize dose to surrounding tissues. Materials and Methods : A planar four-field plan, a planar six-field plan, a tetrad plan, and a hexad plan are analyzed using a 3D treatment planning system which is capable of displaying real-time 3D dose distributions within volume reconstructed data sets (VISTAnet—an extension of the virtual simulator). The tetrad plan is based on the methane molecule and the hexad plan has a minimum separation of 58° on beam entrance. All fields are conformal. The irradiated volume equals the clinical target volume plus a 1 cm margin. Competing plans are compared using cumulative dose-volume histograms and normal tissue complication probabilities. Results : The crossover point, the isodose surface that conforms more to the beams than the target, is introduced and described. The hexad and tetrad plans result in tighter dose distributions when compared to the planar plans with the same number of beams. The tetrad plan treats a volume less than or equal to the planar six-field plan at isodose surfaces above 18% except between 37% and 44% where the tetrad volume is slightly larger. As expected from integral dose considerations, the amount of normal tissue receiving some radiation increases, but the amount receiving clinically significant amounts of radiation decreases as the number of beams increase. The plan involving the largest number of noncoplanar beams results in the tightest isodose distribution. Analysis of rectal and bladder cumulative dose volume histograms does not reveal a clearly superior plan based on normal tissue complication probabilities. Conclusions : Using basic principles of solid geometry, maximally separated beams without significant overlap on exit or entrance can be designed which minimize clinically significant dose to surrounding tissues and tighten the isodose distribution around the target volume. The emphasis of this treatment plan optimization is geometric in contrast to methods using computer optimization or artificial intelligence.</description><identifier>ISSN: 0360-3016</identifier><identifier>EISSN: 1879-355X</identifier><identifier>DOI: 10.1016/0360-3016(94)90026-4</identifier><identifier>PMID: 7928471</identifier><identifier>CODEN: IOBPD3</identifier><language>eng</language><publisher>New York, NY: Elsevier Inc</publisher><subject>Biological and medical sciences ; Diseases of the urinary system ; Humans ; Male ; Medical sciences ; Prostate carcinoma ; Prostatic Neoplasms - radiotherapy ; Radiation therapy treatment plan optimization ; Radiation therapy treatment planning ; Radiotherapy Planning, Computer-Assisted ; Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)</subject><ispartof>International journal of radiation oncology, biology, physics, 1994-09, Vol.30 (2), p.439-446</ispartof><rights>1994</rights><rights>1995 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c386t-a831addbdfb3978ed7b859083d05744d5823f981ae28591309b5aaa9131048873</citedby><cites>FETCH-LOGICAL-c386t-a831addbdfb3978ed7b859083d05744d5823f981ae28591309b5aaa9131048873</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/0360301694900264$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>309,310,314,776,780,785,786,3537,23909,23910,25118,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=3300427$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7928471$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sailer, Scott L.</creatorcontrib><creatorcontrib>Rosenman, Julian G.</creatorcontrib><creatorcontrib>Symon, James R.</creatorcontrib><creatorcontrib>Cullip, Timothy J.</creatorcontrib><creatorcontrib>Chaney, Edward L.</creatorcontrib><title>The tetrad and hexad: Maximum beam separation as a starting point for noncoplanar 3D treatment planning: Prostate cancer as a test case</title><title>International journal of radiation oncology, biology, physics</title><addtitle>Int J Radiat Oncol Biol Phys</addtitle><description>Purpose : In contrast to computer optimized three-dimensional (3D) treatment planning, we have used maximally separated, noncoplanar beams as the starting point for 3D treatment planning of prostate cancer to maximize the rate of dose fall off from the target volume and minimize dose to surrounding tissues. Materials and Methods : A planar four-field plan, a planar six-field plan, a tetrad plan, and a hexad plan are analyzed using a 3D treatment planning system which is capable of displaying real-time 3D dose distributions within volume reconstructed data sets (VISTAnet—an extension of the virtual simulator). The tetrad plan is based on the methane molecule and the hexad plan has a minimum separation of 58° on beam entrance. All fields are conformal. The irradiated volume equals the clinical target volume plus a 1 cm margin. Competing plans are compared using cumulative dose-volume histograms and normal tissue complication probabilities. Results : The crossover point, the isodose surface that conforms more to the beams than the target, is introduced and described. The hexad and tetrad plans result in tighter dose distributions when compared to the planar plans with the same number of beams. The tetrad plan treats a volume less than or equal to the planar six-field plan at isodose surfaces above 18% except between 37% and 44% where the tetrad volume is slightly larger. As expected from integral dose considerations, the amount of normal tissue receiving some radiation increases, but the amount receiving clinically significant amounts of radiation decreases as the number of beams increase. The plan involving the largest number of noncoplanar beams results in the tightest isodose distribution. Analysis of rectal and bladder cumulative dose volume histograms does not reveal a clearly superior plan based on normal tissue complication probabilities. Conclusions : Using basic principles of solid geometry, maximally separated beams without significant overlap on exit or entrance can be designed which minimize clinically significant dose to surrounding tissues and tighten the isodose distribution around the target volume. The emphasis of this treatment plan optimization is geometric in contrast to methods using computer optimization or artificial intelligence.</description><subject>Biological and medical sciences</subject><subject>Diseases of the urinary system</subject><subject>Humans</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Prostate carcinoma</subject><subject>Prostatic Neoplasms - radiotherapy</subject><subject>Radiation therapy treatment plan optimization</subject><subject>Radiation therapy treatment planning</subject><subject>Radiotherapy Planning, Computer-Assisted</subject><subject>Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)</subject><issn>0360-3016</issn><issn>1879-355X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kM9u1DAQxi0EKkvhDUDyAaFyCNixE9s9IKHyVyqCQ5G4WRN7Qo02TrC9VXkCXhunu9ojpxnNfN83ox8hTzl7xRnvXzPRs0bU7szIl4axtm_kPbLhWplGdN2P-2RzlDwkj3L-xRjjXMkTcqJMq6XiG_L36hppwZLAU4ieXuMt-HP6BW7DtJvogDDRjAskKGGOFDIFmgukEuJPuswhFjrOicY5unnZQoRExTtaEkKZsC7XWazac_otzdVYkDqIDtM-qmAudZDxMXkwwjbjk0M9Jd8_vL-6-NRcfv34-eLtZeOE7ksDWnDwfvDjIIzS6NWgO8O08KxTUvpOt2I0mgO2dc4FM0MHALXjTGqtxCl5sc9d0vx7V6_bKWSH2_omzrtsVa9kZ9pVKPdCV__OCUe7pDBB-mM5syt_u8K1K1xrpL3jb2W1PTvk74YJ_dF0AF73zw97yA62Y6owQj7KhGBM3l1_s5dhZXETMNnsAlZuPiR0xfo5_P-Pf7DpoWw</recordid><startdate>19940930</startdate><enddate>19940930</enddate><creator>Sailer, Scott L.</creator><creator>Rosenman, Julian G.</creator><creator>Symon, James R.</creator><creator>Cullip, Timothy J.</creator><creator>Chaney, Edward L.</creator><general>Elsevier Inc</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19940930</creationdate><title>The tetrad and hexad: Maximum beam separation as a starting point for noncoplanar 3D treatment planning: Prostate cancer as a test case</title><author>Sailer, Scott L. ; Rosenman, Julian G. ; Symon, James R. ; Cullip, Timothy J. ; Chaney, Edward L.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c386t-a831addbdfb3978ed7b859083d05744d5823f981ae28591309b5aaa9131048873</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Biological and medical sciences</topic><topic>Diseases of the urinary system</topic><topic>Humans</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Prostate carcinoma</topic><topic>Prostatic Neoplasms - radiotherapy</topic><topic>Radiation therapy treatment plan optimization</topic><topic>Radiation therapy treatment planning</topic><topic>Radiotherapy Planning, Computer-Assisted</topic><topic>Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sailer, Scott L.</creatorcontrib><creatorcontrib>Rosenman, Julian G.</creatorcontrib><creatorcontrib>Symon, James R.</creatorcontrib><creatorcontrib>Cullip, Timothy J.</creatorcontrib><creatorcontrib>Chaney, Edward L.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International journal of radiation oncology, biology, physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sailer, Scott L.</au><au>Rosenman, Julian G.</au><au>Symon, James R.</au><au>Cullip, Timothy J.</au><au>Chaney, Edward L.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The tetrad and hexad: Maximum beam separation as a starting point for noncoplanar 3D treatment planning: Prostate cancer as a test case</atitle><jtitle>International journal of radiation oncology, biology, physics</jtitle><addtitle>Int J Radiat Oncol Biol Phys</addtitle><date>1994-09-30</date><risdate>1994</risdate><volume>30</volume><issue>2</issue><spage>439</spage><epage>446</epage><pages>439-446</pages><issn>0360-3016</issn><eissn>1879-355X</eissn><coden>IOBPD3</coden><abstract>Purpose : In contrast to computer optimized three-dimensional (3D) treatment planning, we have used maximally separated, noncoplanar beams as the starting point for 3D treatment planning of prostate cancer to maximize the rate of dose fall off from the target volume and minimize dose to surrounding tissues. Materials and Methods : A planar four-field plan, a planar six-field plan, a tetrad plan, and a hexad plan are analyzed using a 3D treatment planning system which is capable of displaying real-time 3D dose distributions within volume reconstructed data sets (VISTAnet—an extension of the virtual simulator). The tetrad plan is based on the methane molecule and the hexad plan has a minimum separation of 58° on beam entrance. All fields are conformal. The irradiated volume equals the clinical target volume plus a 1 cm margin. Competing plans are compared using cumulative dose-volume histograms and normal tissue complication probabilities. Results : The crossover point, the isodose surface that conforms more to the beams than the target, is introduced and described. The hexad and tetrad plans result in tighter dose distributions when compared to the planar plans with the same number of beams. The tetrad plan treats a volume less than or equal to the planar six-field plan at isodose surfaces above 18% except between 37% and 44% where the tetrad volume is slightly larger. As expected from integral dose considerations, the amount of normal tissue receiving some radiation increases, but the amount receiving clinically significant amounts of radiation decreases as the number of beams increase. The plan involving the largest number of noncoplanar beams results in the tightest isodose distribution. Analysis of rectal and bladder cumulative dose volume histograms does not reveal a clearly superior plan based on normal tissue complication probabilities. Conclusions : Using basic principles of solid geometry, maximally separated beams without significant overlap on exit or entrance can be designed which minimize clinically significant dose to surrounding tissues and tighten the isodose distribution around the target volume. The emphasis of this treatment plan optimization is geometric in contrast to methods using computer optimization or artificial intelligence.</abstract><cop>New York, NY</cop><pub>Elsevier Inc</pub><pmid>7928471</pmid><doi>10.1016/0360-3016(94)90026-4</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0360-3016
ispartof International journal of radiation oncology, biology, physics, 1994-09, Vol.30 (2), p.439-446
issn 0360-3016
1879-355X
language eng
recordid cdi_proquest_miscellaneous_76745927
source MEDLINE; Elsevier ScienceDirect Journals
subjects Biological and medical sciences
Diseases of the urinary system
Humans
Male
Medical sciences
Prostate carcinoma
Prostatic Neoplasms - radiotherapy
Radiation therapy treatment plan optimization
Radiation therapy treatment planning
Radiotherapy Planning, Computer-Assisted
Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)
title The tetrad and hexad: Maximum beam separation as a starting point for noncoplanar 3D treatment planning: Prostate cancer as a test case
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T05%3A11%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20tetrad%20and%20hexad:%20Maximum%20beam%20separation%20as%20a%20starting%20point%20for%20noncoplanar%203D%20treatment%20planning:%20Prostate%20cancer%20as%20a%20test%20case&rft.jtitle=International%20journal%20of%20radiation%20oncology,%20biology,%20physics&rft.au=Sailer,%20Scott%20L.&rft.date=1994-09-30&rft.volume=30&rft.issue=2&rft.spage=439&rft.epage=446&rft.pages=439-446&rft.issn=0360-3016&rft.eissn=1879-355X&rft.coden=IOBPD3&rft_id=info:doi/10.1016/0360-3016(94)90026-4&rft_dat=%3Cproquest_cross%3E76745927%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=76745927&rft_id=info:pmid/7928471&rft_els_id=0360301694900264&rfr_iscdi=true