Effect of Acute Experimental Pulmonary Arterial Occlusion on the Deposition and Clearance of Technetium-99m-DTPA Radioaerosols

Canine models of autologous PE and balloon occlusion of the pulmonary vasculature were used to evaluate radioaerosol deposition and to quantify radioaerosol clearance in the immediate postembolic period. A total of 28 animals were anesthetized, intubated and studied (central balloon occlusion = 4, p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of nuclear medicine (1978) 1994-08, Vol.35 (8), p.1351-1357
Hauptverfasser: Mori, Yutaka, Alderson, Philip O, Berman, Howard L
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1357
container_issue 8
container_start_page 1351
container_title The Journal of nuclear medicine (1978)
container_volume 35
creator Mori, Yutaka
Alderson, Philip O
Berman, Howard L
description Canine models of autologous PE and balloon occlusion of the pulmonary vasculature were used to evaluate radioaerosol deposition and to quantify radioaerosol clearance in the immediate postembolic period. A total of 28 animals were anesthetized, intubated and studied (central balloon occlusion = 4, peripheral balloon occlusion = 7, autologous PE = 5, various control groups = 12). A gamma camera computer system was used to monitor the distribution and clearance rate of inhaled DTPA radioaerosol. The perfusion defect distribution was determined after the radioaerosol study using 99mTc-MAA. A new radioaerosol deposition defect was seen in 3 of 16 animals in a zone of acute vascular occlusion by a balloon (n = 2) or PE (n = 1). In addition, radioaerosol clearance rates were altered substantially. Peripheral vascular occlusion and PE caused radioaerosol clearance rates to accelerate significantly (control clearance half-time = 33.6 +/- 4.6 min, post-balloon occlusion = 19.0 +/- 8.3 min, post-PE = 12.4 +/_ 3.7 min, both p < 0.05). In only one case did these clearance rate changes create a visible abnormality in the aerosol images. The pulmonary deposition patterns and clearance rates of 99mTc-DTPA radioaerosol can be altered by acute vascular occlusion or PE. These findings should be considered when interpreting radioaerosol images in patients with suspected PE.
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_76638035</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>76638035</sourcerecordid><originalsourceid>FETCH-LOGICAL-h238t-e138fa53ea40349dad24c4e48b49842f8e4c6f93eeb3233f77d5d1695c09e2913</originalsourceid><addsrcrecordid>eNotkF1LwzAYhYsoc05_gpArvSqkzUeTyzLnBww2ZF6XLH1jO9KkNinqjb_djg1eeOE5hwPnXCTzjBGWMs6Ly2SOM56ljGF2ndyEcMAYcyHELJkJTDmVZJ78rYwBHZE3qNRjBLT66WFoO3BRWbQdbeedGn5ROcQJT2ijtR1D6x2aLjaAnqD3oY1HolyNlhbUoJyGY-QOdOMgtmOXStmlT7ttid5V3XoFgw_ehtvkyigb4O78F8nH82q3fE3Xm5e3ZblOm5yImEJGhFGMgKKYUFmrOqeaAhV7KgXNjQCquZEEYE9yQkxR1KzOuGQaS8hlRhbJwym3H_zXCCFWXRs0WKsc-DFUBedEYMIm4_3ZOO47qKt-2mLqX50Hm_THk960n813O0DlRn2sfDQfXEdYJaqMsIz8A14kdrY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>76638035</pqid></control><display><type>article</type><title>Effect of Acute Experimental Pulmonary Arterial Occlusion on the Deposition and Clearance of Technetium-99m-DTPA Radioaerosols</title><source>MEDLINE</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Mori, Yutaka ; Alderson, Philip O ; Berman, Howard L</creator><creatorcontrib>Mori, Yutaka ; Alderson, Philip O ; Berman, Howard L</creatorcontrib><description>Canine models of autologous PE and balloon occlusion of the pulmonary vasculature were used to evaluate radioaerosol deposition and to quantify radioaerosol clearance in the immediate postembolic period. A total of 28 animals were anesthetized, intubated and studied (central balloon occlusion = 4, peripheral balloon occlusion = 7, autologous PE = 5, various control groups = 12). A gamma camera computer system was used to monitor the distribution and clearance rate of inhaled DTPA radioaerosol. The perfusion defect distribution was determined after the radioaerosol study using 99mTc-MAA. A new radioaerosol deposition defect was seen in 3 of 16 animals in a zone of acute vascular occlusion by a balloon (n = 2) or PE (n = 1). In addition, radioaerosol clearance rates were altered substantially. Peripheral vascular occlusion and PE caused radioaerosol clearance rates to accelerate significantly (control clearance half-time = 33.6 +/- 4.6 min, post-balloon occlusion = 19.0 +/- 8.3 min, post-PE = 12.4 +/_ 3.7 min, both p &lt; 0.05). In only one case did these clearance rate changes create a visible abnormality in the aerosol images. The pulmonary deposition patterns and clearance rates of 99mTc-DTPA radioaerosol can be altered by acute vascular occlusion or PE. These findings should be considered when interpreting radioaerosol images in patients with suspected PE.</description><identifier>ISSN: 0161-5505</identifier><identifier>EISSN: 1535-5667</identifier><identifier>PMID: 8046493</identifier><language>eng</language><publisher>United States: Soc Nuclear Med</publisher><subject>Aerosols ; Animals ; Catheterization ; Dogs ; Lung - diagnostic imaging ; Pulmonary Artery ; Pulmonary Embolism - diagnostic imaging ; Radionuclide Imaging ; Technetium Tc 99m Aggregated Albumin ; Technetium Tc 99m Pentetate</subject><ispartof>The Journal of nuclear medicine (1978), 1994-08, Vol.35 (8), p.1351-1357</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8046493$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mori, Yutaka</creatorcontrib><creatorcontrib>Alderson, Philip O</creatorcontrib><creatorcontrib>Berman, Howard L</creatorcontrib><title>Effect of Acute Experimental Pulmonary Arterial Occlusion on the Deposition and Clearance of Technetium-99m-DTPA Radioaerosols</title><title>The Journal of nuclear medicine (1978)</title><addtitle>J Nucl Med</addtitle><description>Canine models of autologous PE and balloon occlusion of the pulmonary vasculature were used to evaluate radioaerosol deposition and to quantify radioaerosol clearance in the immediate postembolic period. A total of 28 animals were anesthetized, intubated and studied (central balloon occlusion = 4, peripheral balloon occlusion = 7, autologous PE = 5, various control groups = 12). A gamma camera computer system was used to monitor the distribution and clearance rate of inhaled DTPA radioaerosol. The perfusion defect distribution was determined after the radioaerosol study using 99mTc-MAA. A new radioaerosol deposition defect was seen in 3 of 16 animals in a zone of acute vascular occlusion by a balloon (n = 2) or PE (n = 1). In addition, radioaerosol clearance rates were altered substantially. Peripheral vascular occlusion and PE caused radioaerosol clearance rates to accelerate significantly (control clearance half-time = 33.6 +/- 4.6 min, post-balloon occlusion = 19.0 +/- 8.3 min, post-PE = 12.4 +/_ 3.7 min, both p &lt; 0.05). In only one case did these clearance rate changes create a visible abnormality in the aerosol images. The pulmonary deposition patterns and clearance rates of 99mTc-DTPA radioaerosol can be altered by acute vascular occlusion or PE. These findings should be considered when interpreting radioaerosol images in patients with suspected PE.</description><subject>Aerosols</subject><subject>Animals</subject><subject>Catheterization</subject><subject>Dogs</subject><subject>Lung - diagnostic imaging</subject><subject>Pulmonary Artery</subject><subject>Pulmonary Embolism - diagnostic imaging</subject><subject>Radionuclide Imaging</subject><subject>Technetium Tc 99m Aggregated Albumin</subject><subject>Technetium Tc 99m Pentetate</subject><issn>0161-5505</issn><issn>1535-5667</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNotkF1LwzAYhYsoc05_gpArvSqkzUeTyzLnBww2ZF6XLH1jO9KkNinqjb_djg1eeOE5hwPnXCTzjBGWMs6Ly2SOM56ljGF2ndyEcMAYcyHELJkJTDmVZJ78rYwBHZE3qNRjBLT66WFoO3BRWbQdbeedGn5ROcQJT2ijtR1D6x2aLjaAnqD3oY1HolyNlhbUoJyGY-QOdOMgtmOXStmlT7ttid5V3XoFgw_ehtvkyigb4O78F8nH82q3fE3Xm5e3ZblOm5yImEJGhFGMgKKYUFmrOqeaAhV7KgXNjQCquZEEYE9yQkxR1KzOuGQaS8hlRhbJwym3H_zXCCFWXRs0WKsc-DFUBedEYMIm4_3ZOO47qKt-2mLqX50Hm_THk960n813O0DlRn2sfDQfXEdYJaqMsIz8A14kdrY</recordid><startdate>19940801</startdate><enddate>19940801</enddate><creator>Mori, Yutaka</creator><creator>Alderson, Philip O</creator><creator>Berman, Howard L</creator><general>Soc Nuclear Med</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>19940801</creationdate><title>Effect of Acute Experimental Pulmonary Arterial Occlusion on the Deposition and Clearance of Technetium-99m-DTPA Radioaerosols</title><author>Mori, Yutaka ; Alderson, Philip O ; Berman, Howard L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-h238t-e138fa53ea40349dad24c4e48b49842f8e4c6f93eeb3233f77d5d1695c09e2913</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Aerosols</topic><topic>Animals</topic><topic>Catheterization</topic><topic>Dogs</topic><topic>Lung - diagnostic imaging</topic><topic>Pulmonary Artery</topic><topic>Pulmonary Embolism - diagnostic imaging</topic><topic>Radionuclide Imaging</topic><topic>Technetium Tc 99m Aggregated Albumin</topic><topic>Technetium Tc 99m Pentetate</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mori, Yutaka</creatorcontrib><creatorcontrib>Alderson, Philip O</creatorcontrib><creatorcontrib>Berman, Howard L</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of nuclear medicine (1978)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mori, Yutaka</au><au>Alderson, Philip O</au><au>Berman, Howard L</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of Acute Experimental Pulmonary Arterial Occlusion on the Deposition and Clearance of Technetium-99m-DTPA Radioaerosols</atitle><jtitle>The Journal of nuclear medicine (1978)</jtitle><addtitle>J Nucl Med</addtitle><date>1994-08-01</date><risdate>1994</risdate><volume>35</volume><issue>8</issue><spage>1351</spage><epage>1357</epage><pages>1351-1357</pages><issn>0161-5505</issn><eissn>1535-5667</eissn><abstract>Canine models of autologous PE and balloon occlusion of the pulmonary vasculature were used to evaluate radioaerosol deposition and to quantify radioaerosol clearance in the immediate postembolic period. A total of 28 animals were anesthetized, intubated and studied (central balloon occlusion = 4, peripheral balloon occlusion = 7, autologous PE = 5, various control groups = 12). A gamma camera computer system was used to monitor the distribution and clearance rate of inhaled DTPA radioaerosol. The perfusion defect distribution was determined after the radioaerosol study using 99mTc-MAA. A new radioaerosol deposition defect was seen in 3 of 16 animals in a zone of acute vascular occlusion by a balloon (n = 2) or PE (n = 1). In addition, radioaerosol clearance rates were altered substantially. Peripheral vascular occlusion and PE caused radioaerosol clearance rates to accelerate significantly (control clearance half-time = 33.6 +/- 4.6 min, post-balloon occlusion = 19.0 +/- 8.3 min, post-PE = 12.4 +/_ 3.7 min, both p &lt; 0.05). In only one case did these clearance rate changes create a visible abnormality in the aerosol images. The pulmonary deposition patterns and clearance rates of 99mTc-DTPA radioaerosol can be altered by acute vascular occlusion or PE. These findings should be considered when interpreting radioaerosol images in patients with suspected PE.</abstract><cop>United States</cop><pub>Soc Nuclear Med</pub><pmid>8046493</pmid><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0161-5505
ispartof The Journal of nuclear medicine (1978), 1994-08, Vol.35 (8), p.1351-1357
issn 0161-5505
1535-5667
language eng
recordid cdi_proquest_miscellaneous_76638035
source MEDLINE; EZB-FREE-00999 freely available EZB journals
subjects Aerosols
Animals
Catheterization
Dogs
Lung - diagnostic imaging
Pulmonary Artery
Pulmonary Embolism - diagnostic imaging
Radionuclide Imaging
Technetium Tc 99m Aggregated Albumin
Technetium Tc 99m Pentetate
title Effect of Acute Experimental Pulmonary Arterial Occlusion on the Deposition and Clearance of Technetium-99m-DTPA Radioaerosols
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T19%3A33%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20Acute%20Experimental%20Pulmonary%20Arterial%20Occlusion%20on%20the%20Deposition%20and%20Clearance%20of%20Technetium-99m-DTPA%20Radioaerosols&rft.jtitle=The%20Journal%20of%20nuclear%20medicine%20(1978)&rft.au=Mori,%20Yutaka&rft.date=1994-08-01&rft.volume=35&rft.issue=8&rft.spage=1351&rft.epage=1357&rft.pages=1351-1357&rft.issn=0161-5505&rft.eissn=1535-5667&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E76638035%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=76638035&rft_id=info:pmid/8046493&rfr_iscdi=true