Complications of neonatal extracorporeal membrane oxygenation. Collective experience from the Extracorporeal Life Support Organization
Since 1973, 7667 neonates have been treated with extracorporeal membrane oxygenation for severe respiratory failure and their cases reported to the Extracorporeal Life Support Organization Registry. The overall survival was 81% in these neonates, who were thought to have a survival of 20% without ex...
Gespeichert in:
Veröffentlicht in: | The Journal of thoracic and cardiovascular surgery 1994-03, Vol.107 (3), p.838-48; discussion 848-9 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 48; discussion 848-9 |
---|---|
container_issue | 3 |
container_start_page | 838 |
container_title | The Journal of thoracic and cardiovascular surgery |
container_volume | 107 |
creator | Zwischenberger, J B Nguyen, T T Upp, Jr, J R Bush, P E Cox, Jr, C S Delosh, T Broemling, L |
description | Since 1973, 7667 neonates have been treated with extracorporeal membrane oxygenation for severe respiratory failure and their cases reported to the Extracorporeal Life Support Organization Registry. The overall survival was 81% in these neonates, who were thought to have a survival of 20% without extracorporeal membrane oxygenation. A total of 4322 mechanical complications (0.56 +/- 0.84 per case) and 13,827 patient complications (1.80 +/- 2.12 per case) were reported overall. The most common mechanical complications included clots in the circuit (19%), cannula placement (9%), oxygenator failure (4%), and others (9%). Common patient complications included cardiopulmonary (43%), neurologic (35%), bleeding (35%), metabolic (32%), renal (25%), and renal (25%), and infectious (9%). From the initial experience to 1988 the average number of mechanical complications per case was 0.27 per case and this significantly increased during 1990 to 1992 to 0.75 per case (p < 0.05). Likewise, from 1973-1985 to 1988 the average patient complications per case were 1.44 per case and this significantly increased during 1990 to 1992 to 2.10 per case. During the same periods, patient survival significantly decreased from 84% (1973-1985 to 1988, n = 2463) to 80% (1990 to 1992, n = 4005). Venovenous double-lumen single cannula extracorporeal membrane oxygenation had a higher survival than venoarterial extracorporeal membrane oxygenation (91% versus 81%) and a lower rate of major neurologic complications. The incidence and survival with seizures (6% and 89% venovenous versus 13% and 61% venoarterial) or cerebral infarction (9% and 69% venovenous versus 14% and 46% venoarterial) was significantly lower with the venovenous method and appeared to have a substantial impact on overall survival. The correlation of patient complication rate and total complication rate with survival was highly significant, however, causality cannot be established. Explanations for the increase in complications, relative to a decrease in survival, despite a growing nationwide experience include (1) increased complexity of cases as many programs expand entry criteria (more premature infants, infants with grade 1 or 2 intracranial hemorrhage, and complex congenital diaphragmatic hernia), (2) a growing number of programs with fewer cases per program, yet greater accessibility, (3) less reluctance to report complications encountered during extracorporeal membrane oxygenation as group experience grows, and (4) c |
doi_str_mv | 10.1016/s0022-5223(94)70340-x |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_76389420</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>76389420</sourcerecordid><originalsourceid>FETCH-LOGICAL-p206t-7b5db0f5e24e528e585d80f3b7532adbec505ec2972cabe6034b78a512f334a13</originalsourceid><addsrcrecordid>eNpVkMtOwzAQRb0AlVL4hEpeIVik-BHHyRJV5SFV6gJYR7YzKUZJHGwHtXwA301UKiRWozs6c6S5CM0pWVBCs9tACGOJYIxfF-mNJDwlye4ETf_WZ-g8hHdCiCS0mKBJTpmklE_R99K1fWONitZ1Absad-A6FVWDYRe9Ms73zsMYW2i1Vx1gt9tvoTscLPDSNQ2YaD9h5HvwFjoDuPauxfEN8Oq_Y21rwM9DP8aIN36rOvt1EF2g01o1AS6Pc4Ze71cvy8dkvXl4Wt6tk56RLCZSi0qTWgBLQbAcRC6qnNRcS8GZqjQYQQQYVkhmlIZsLELLXAnKas5TRfkMXf16e-8-BgixbG0w0DTjY24Ipcx4XqSMjOD8CA66harsvW2V35fH4vgPhhNzJA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>76389420</pqid></control><display><type>article</type><title>Complications of neonatal extracorporeal membrane oxygenation. Collective experience from the Extracorporeal Life Support Organization</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Zwischenberger, J B ; Nguyen, T T ; Upp, Jr, J R ; Bush, P E ; Cox, Jr, C S ; Delosh, T ; Broemling, L</creator><creatorcontrib>Zwischenberger, J B ; Nguyen, T T ; Upp, Jr, J R ; Bush, P E ; Cox, Jr, C S ; Delosh, T ; Broemling, L</creatorcontrib><description>Since 1973, 7667 neonates have been treated with extracorporeal membrane oxygenation for severe respiratory failure and their cases reported to the Extracorporeal Life Support Organization Registry. The overall survival was 81% in these neonates, who were thought to have a survival of 20% without extracorporeal membrane oxygenation. A total of 4322 mechanical complications (0.56 +/- 0.84 per case) and 13,827 patient complications (1.80 +/- 2.12 per case) were reported overall. The most common mechanical complications included clots in the circuit (19%), cannula placement (9%), oxygenator failure (4%), and others (9%). Common patient complications included cardiopulmonary (43%), neurologic (35%), bleeding (35%), metabolic (32%), renal (25%), and renal (25%), and infectious (9%). From the initial experience to 1988 the average number of mechanical complications per case was 0.27 per case and this significantly increased during 1990 to 1992 to 0.75 per case (p < 0.05). Likewise, from 1973-1985 to 1988 the average patient complications per case were 1.44 per case and this significantly increased during 1990 to 1992 to 2.10 per case. During the same periods, patient survival significantly decreased from 84% (1973-1985 to 1988, n = 2463) to 80% (1990 to 1992, n = 4005). Venovenous double-lumen single cannula extracorporeal membrane oxygenation had a higher survival than venoarterial extracorporeal membrane oxygenation (91% versus 81%) and a lower rate of major neurologic complications. The incidence and survival with seizures (6% and 89% venovenous versus 13% and 61% venoarterial) or cerebral infarction (9% and 69% venovenous versus 14% and 46% venoarterial) was significantly lower with the venovenous method and appeared to have a substantial impact on overall survival. The correlation of patient complication rate and total complication rate with survival was highly significant, however, causality cannot be established. Explanations for the increase in complications, relative to a decrease in survival, despite a growing nationwide experience include (1) increased complexity of cases as many programs expand entry criteria (more premature infants, infants with grade 1 or 2 intracranial hemorrhage, and complex congenital diaphragmatic hernia), (2) a growing number of programs with fewer cases per program, yet greater accessibility, (3) less reluctance to report complications encountered during extracorporeal membrane oxygenation as group experience grows, and (4) changes in the Extracorporeal Life Support Organization data form to be more inclusive of more minor complications.</description><identifier>ISSN: 0022-5223</identifier><identifier>DOI: 10.1016/s0022-5223(94)70340-x</identifier><identifier>PMID: 8127113</identifier><language>eng</language><publisher>United States</publisher><subject>Equipment Failure - statistics & numerical data ; Europe - epidemiology ; Extracorporeal Membrane Oxygenation - adverse effects ; Extracorporeal Membrane Oxygenation - methods ; Extracorporeal Membrane Oxygenation - mortality ; Humans ; Infant, Newborn ; Linear Models ; Registries ; Respiratory Insufficiency - mortality ; Respiratory Insufficiency - therapy ; Survival Analysis ; Survival Rate ; United States - epidemiology</subject><ispartof>The Journal of thoracic and cardiovascular surgery, 1994-03, Vol.107 (3), p.838-48; discussion 848-9</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8127113$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zwischenberger, J B</creatorcontrib><creatorcontrib>Nguyen, T T</creatorcontrib><creatorcontrib>Upp, Jr, J R</creatorcontrib><creatorcontrib>Bush, P E</creatorcontrib><creatorcontrib>Cox, Jr, C S</creatorcontrib><creatorcontrib>Delosh, T</creatorcontrib><creatorcontrib>Broemling, L</creatorcontrib><title>Complications of neonatal extracorporeal membrane oxygenation. Collective experience from the Extracorporeal Life Support Organization</title><title>The Journal of thoracic and cardiovascular surgery</title><addtitle>J Thorac Cardiovasc Surg</addtitle><description>Since 1973, 7667 neonates have been treated with extracorporeal membrane oxygenation for severe respiratory failure and their cases reported to the Extracorporeal Life Support Organization Registry. The overall survival was 81% in these neonates, who were thought to have a survival of 20% without extracorporeal membrane oxygenation. A total of 4322 mechanical complications (0.56 +/- 0.84 per case) and 13,827 patient complications (1.80 +/- 2.12 per case) were reported overall. The most common mechanical complications included clots in the circuit (19%), cannula placement (9%), oxygenator failure (4%), and others (9%). Common patient complications included cardiopulmonary (43%), neurologic (35%), bleeding (35%), metabolic (32%), renal (25%), and renal (25%), and infectious (9%). From the initial experience to 1988 the average number of mechanical complications per case was 0.27 per case and this significantly increased during 1990 to 1992 to 0.75 per case (p < 0.05). Likewise, from 1973-1985 to 1988 the average patient complications per case were 1.44 per case and this significantly increased during 1990 to 1992 to 2.10 per case. During the same periods, patient survival significantly decreased from 84% (1973-1985 to 1988, n = 2463) to 80% (1990 to 1992, n = 4005). Venovenous double-lumen single cannula extracorporeal membrane oxygenation had a higher survival than venoarterial extracorporeal membrane oxygenation (91% versus 81%) and a lower rate of major neurologic complications. The incidence and survival with seizures (6% and 89% venovenous versus 13% and 61% venoarterial) or cerebral infarction (9% and 69% venovenous versus 14% and 46% venoarterial) was significantly lower with the venovenous method and appeared to have a substantial impact on overall survival. The correlation of patient complication rate and total complication rate with survival was highly significant, however, causality cannot be established. Explanations for the increase in complications, relative to a decrease in survival, despite a growing nationwide experience include (1) increased complexity of cases as many programs expand entry criteria (more premature infants, infants with grade 1 or 2 intracranial hemorrhage, and complex congenital diaphragmatic hernia), (2) a growing number of programs with fewer cases per program, yet greater accessibility, (3) less reluctance to report complications encountered during extracorporeal membrane oxygenation as group experience grows, and (4) changes in the Extracorporeal Life Support Organization data form to be more inclusive of more minor complications.</description><subject>Equipment Failure - statistics & numerical data</subject><subject>Europe - epidemiology</subject><subject>Extracorporeal Membrane Oxygenation - adverse effects</subject><subject>Extracorporeal Membrane Oxygenation - methods</subject><subject>Extracorporeal Membrane Oxygenation - mortality</subject><subject>Humans</subject><subject>Infant, Newborn</subject><subject>Linear Models</subject><subject>Registries</subject><subject>Respiratory Insufficiency - mortality</subject><subject>Respiratory Insufficiency - therapy</subject><subject>Survival Analysis</subject><subject>Survival Rate</subject><subject>United States - epidemiology</subject><issn>0022-5223</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpVkMtOwzAQRb0AlVL4hEpeIVik-BHHyRJV5SFV6gJYR7YzKUZJHGwHtXwA301UKiRWozs6c6S5CM0pWVBCs9tACGOJYIxfF-mNJDwlye4ETf_WZ-g8hHdCiCS0mKBJTpmklE_R99K1fWONitZ1Absad-A6FVWDYRe9Ms73zsMYW2i1Vx1gt9tvoTscLPDSNQ2YaD9h5HvwFjoDuPauxfEN8Oq_Y21rwM9DP8aIN36rOvt1EF2g01o1AS6Pc4Ze71cvy8dkvXl4Wt6tk56RLCZSi0qTWgBLQbAcRC6qnNRcS8GZqjQYQQQYVkhmlIZsLELLXAnKas5TRfkMXf16e-8-BgixbG0w0DTjY24Ipcx4XqSMjOD8CA66harsvW2V35fH4vgPhhNzJA</recordid><startdate>19940301</startdate><enddate>19940301</enddate><creator>Zwischenberger, J B</creator><creator>Nguyen, T T</creator><creator>Upp, Jr, J R</creator><creator>Bush, P E</creator><creator>Cox, Jr, C S</creator><creator>Delosh, T</creator><creator>Broemling, L</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>19940301</creationdate><title>Complications of neonatal extracorporeal membrane oxygenation. Collective experience from the Extracorporeal Life Support Organization</title><author>Zwischenberger, J B ; Nguyen, T T ; Upp, Jr, J R ; Bush, P E ; Cox, Jr, C S ; Delosh, T ; Broemling, L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p206t-7b5db0f5e24e528e585d80f3b7532adbec505ec2972cabe6034b78a512f334a13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Equipment Failure - statistics & numerical data</topic><topic>Europe - epidemiology</topic><topic>Extracorporeal Membrane Oxygenation - adverse effects</topic><topic>Extracorporeal Membrane Oxygenation - methods</topic><topic>Extracorporeal Membrane Oxygenation - mortality</topic><topic>Humans</topic><topic>Infant, Newborn</topic><topic>Linear Models</topic><topic>Registries</topic><topic>Respiratory Insufficiency - mortality</topic><topic>Respiratory Insufficiency - therapy</topic><topic>Survival Analysis</topic><topic>Survival Rate</topic><topic>United States - epidemiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zwischenberger, J B</creatorcontrib><creatorcontrib>Nguyen, T T</creatorcontrib><creatorcontrib>Upp, Jr, J R</creatorcontrib><creatorcontrib>Bush, P E</creatorcontrib><creatorcontrib>Cox, Jr, C S</creatorcontrib><creatorcontrib>Delosh, T</creatorcontrib><creatorcontrib>Broemling, L</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of thoracic and cardiovascular surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zwischenberger, J B</au><au>Nguyen, T T</au><au>Upp, Jr, J R</au><au>Bush, P E</au><au>Cox, Jr, C S</au><au>Delosh, T</au><au>Broemling, L</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Complications of neonatal extracorporeal membrane oxygenation. Collective experience from the Extracorporeal Life Support Organization</atitle><jtitle>The Journal of thoracic and cardiovascular surgery</jtitle><addtitle>J Thorac Cardiovasc Surg</addtitle><date>1994-03-01</date><risdate>1994</risdate><volume>107</volume><issue>3</issue><spage>838</spage><epage>48; discussion 848-9</epage><pages>838-48; discussion 848-9</pages><issn>0022-5223</issn><abstract>Since 1973, 7667 neonates have been treated with extracorporeal membrane oxygenation for severe respiratory failure and their cases reported to the Extracorporeal Life Support Organization Registry. The overall survival was 81% in these neonates, who were thought to have a survival of 20% without extracorporeal membrane oxygenation. A total of 4322 mechanical complications (0.56 +/- 0.84 per case) and 13,827 patient complications (1.80 +/- 2.12 per case) were reported overall. The most common mechanical complications included clots in the circuit (19%), cannula placement (9%), oxygenator failure (4%), and others (9%). Common patient complications included cardiopulmonary (43%), neurologic (35%), bleeding (35%), metabolic (32%), renal (25%), and renal (25%), and infectious (9%). From the initial experience to 1988 the average number of mechanical complications per case was 0.27 per case and this significantly increased during 1990 to 1992 to 0.75 per case (p < 0.05). Likewise, from 1973-1985 to 1988 the average patient complications per case were 1.44 per case and this significantly increased during 1990 to 1992 to 2.10 per case. During the same periods, patient survival significantly decreased from 84% (1973-1985 to 1988, n = 2463) to 80% (1990 to 1992, n = 4005). Venovenous double-lumen single cannula extracorporeal membrane oxygenation had a higher survival than venoarterial extracorporeal membrane oxygenation (91% versus 81%) and a lower rate of major neurologic complications. The incidence and survival with seizures (6% and 89% venovenous versus 13% and 61% venoarterial) or cerebral infarction (9% and 69% venovenous versus 14% and 46% venoarterial) was significantly lower with the venovenous method and appeared to have a substantial impact on overall survival. The correlation of patient complication rate and total complication rate with survival was highly significant, however, causality cannot be established. Explanations for the increase in complications, relative to a decrease in survival, despite a growing nationwide experience include (1) increased complexity of cases as many programs expand entry criteria (more premature infants, infants with grade 1 or 2 intracranial hemorrhage, and complex congenital diaphragmatic hernia), (2) a growing number of programs with fewer cases per program, yet greater accessibility, (3) less reluctance to report complications encountered during extracorporeal membrane oxygenation as group experience grows, and (4) changes in the Extracorporeal Life Support Organization data form to be more inclusive of more minor complications.</abstract><cop>United States</cop><pmid>8127113</pmid><doi>10.1016/s0022-5223(94)70340-x</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0022-5223 |
ispartof | The Journal of thoracic and cardiovascular surgery, 1994-03, Vol.107 (3), p.838-48; discussion 848-9 |
issn | 0022-5223 |
language | eng |
recordid | cdi_proquest_miscellaneous_76389420 |
source | MEDLINE; Access via ScienceDirect (Elsevier); EZB-FREE-00999 freely available EZB journals |
subjects | Equipment Failure - statistics & numerical data Europe - epidemiology Extracorporeal Membrane Oxygenation - adverse effects Extracorporeal Membrane Oxygenation - methods Extracorporeal Membrane Oxygenation - mortality Humans Infant, Newborn Linear Models Registries Respiratory Insufficiency - mortality Respiratory Insufficiency - therapy Survival Analysis Survival Rate United States - epidemiology |
title | Complications of neonatal extracorporeal membrane oxygenation. Collective experience from the Extracorporeal Life Support Organization |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T07%3A15%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Complications%20of%20neonatal%20extracorporeal%20membrane%20oxygenation.%20Collective%20experience%20from%20the%20Extracorporeal%20Life%20Support%20Organization&rft.jtitle=The%20Journal%20of%20thoracic%20and%20cardiovascular%20surgery&rft.au=Zwischenberger,%20J%20B&rft.date=1994-03-01&rft.volume=107&rft.issue=3&rft.spage=838&rft.epage=48;%20discussion%20848-9&rft.pages=838-48;%20discussion%20848-9&rft.issn=0022-5223&rft_id=info:doi/10.1016/s0022-5223(94)70340-x&rft_dat=%3Cproquest_pubme%3E76389420%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=76389420&rft_id=info:pmid/8127113&rfr_iscdi=true |