Presence of pulsations and reproducibility of waveform recording in the umbilical and left portal vein in normal pregnancies
Reproducibility and inter‐observer variability of intra‐ and extra‐abdominal umbilical venous flow velocity and left portal venous flow velocity as well as heart‐synchronous waveform pulsations in these vessels were studied in 23 women at 34–38 weeks of normal pregnancy. Limited reproducibility, exp...
Gespeichert in:
Veröffentlicht in: | Ultrasound in obstetrics & gynecology 1994-01, Vol.4 (1), p.49-53 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 53 |
---|---|
container_issue | 1 |
container_start_page | 49 |
container_title | Ultrasound in obstetrics & gynecology |
container_volume | 4 |
creator | van Splunder, I. P. Huisman, T. W. A. Stijnen, T. Wladimiroff, J. W. |
description | Reproducibility and inter‐observer variability of intra‐ and extra‐abdominal umbilical venous flow velocity and left portal venous flow velocity as well as heart‐synchronous waveform pulsations in these vessels were studied in 23 women at 34–38 weeks of normal pregnancy.
Limited reproducibility, expressed by large intra‐patient coefficients and limits of agreement between two observers, was established for all standardized recording sites. Pulsations, defined as negative venous deflections of at least 10% of the mean velocity, were demonstrated at all locations ranging from 19.6% of the measurements at the free‐floating loop of the umbilical vein to 78.4% of the measurements at the left portal vein.
The present study shows that the limited reproducibility of venous flow velocity waveforms should be taken into consideration, and that the presence of pulsations can be demonstrated in normal late pregnancy. Copyright © 1994 International Society of Ultrasound in Obstetrics and Gynecology |
doi_str_mv | 10.1046/j.1469-0705.1994.04010049.x |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_76321773</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>76321773</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3446-24ee82fb0bc846658b2b5ecf96c8534850321a956308ade14514ff0f24ae70533</originalsourceid><addsrcrecordid>eNqVkMFq3DAQhkVJabZpXyEYCrnZHcmybNFLQkjSQiA9NGchy6NEiy27kp1koQ8fubttzwWBGOb7Z6SPkE8UCgpcfN4WlAuZQw1VQaXkBXCgAFwWL2_I5m_viGxACshrIdkxeR_jFgAEL8U7ckxZLWvGqg359T1gRG8wG202LX3Usxt9zLTvsoBTGLvFuNb1bt6txLN-QjuGIfXMGDrnHzLns_kRs2VYKaP739Ee7ZxNY5hT_YQJScenXCqngA9ee-MwfiBvre4jfjzcJ-T--urH5df89u7m2-XFbW5KzkXOOGLDbAutabgQVdOytkJjpTBNVfKmgpJRLStRQqM7pLyi3FqwjGtMIsryhJzt56b__Fwwzmpw0WDfa4_jElUt0oC6XsEve9CEMcaAVk3BDTrsFAW1yldbtQpWq2C1yld_5KuXlD49rFnaAbt_2YPtBJzvgWfX4-5_Zqv7uxsq0ztfAUbMldM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>76321773</pqid></control><display><type>article</type><title>Presence of pulsations and reproducibility of waveform recording in the umbilical and left portal vein in normal pregnancies</title><source>Wiley Online Library Journals Frontfile Complete</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>van Splunder, I. P. ; Huisman, T. W. A. ; Stijnen, T. ; Wladimiroff, J. W.</creator><creatorcontrib>van Splunder, I. P. ; Huisman, T. W. A. ; Stijnen, T. ; Wladimiroff, J. W.</creatorcontrib><description>Reproducibility and inter‐observer variability of intra‐ and extra‐abdominal umbilical venous flow velocity and left portal venous flow velocity as well as heart‐synchronous waveform pulsations in these vessels were studied in 23 women at 34–38 weeks of normal pregnancy.
Limited reproducibility, expressed by large intra‐patient coefficients and limits of agreement between two observers, was established for all standardized recording sites. Pulsations, defined as negative venous deflections of at least 10% of the mean velocity, were demonstrated at all locations ranging from 19.6% of the measurements at the free‐floating loop of the umbilical vein to 78.4% of the measurements at the left portal vein.
The present study shows that the limited reproducibility of venous flow velocity waveforms should be taken into consideration, and that the presence of pulsations can be demonstrated in normal late pregnancy. Copyright © 1994 International Society of Ultrasound in Obstetrics and Gynecology</description><identifier>ISSN: 0960-7692</identifier><identifier>EISSN: 1469-0705</identifier><identifier>DOI: 10.1046/j.1469-0705.1994.04010049.x</identifier><identifier>PMID: 12797225</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Science Ltd</publisher><subject>left portal vein ; pulsations ; reproducibility ; ultrasound ; umbilical vein</subject><ispartof>Ultrasound in obstetrics & gynecology, 1994-01, Vol.4 (1), p.49-53</ispartof><rights>Copyright © 1994 International Society of Ultrasound in Obstetrics and Gynecology</rights><rights>Copyright 1994 International Society of Ultrasound in Obstetrics and Gynecology</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3446-24ee82fb0bc846658b2b5ecf96c8534850321a956308ade14514ff0f24ae70533</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1046%2Fj.1469-0705.1994.04010049.x$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1046%2Fj.1469-0705.1994.04010049.x$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27903,27904,45553,45554</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12797225$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>van Splunder, I. P.</creatorcontrib><creatorcontrib>Huisman, T. W. A.</creatorcontrib><creatorcontrib>Stijnen, T.</creatorcontrib><creatorcontrib>Wladimiroff, J. W.</creatorcontrib><title>Presence of pulsations and reproducibility of waveform recording in the umbilical and left portal vein in normal pregnancies</title><title>Ultrasound in obstetrics & gynecology</title><addtitle>Ultrasound Obstet Gynecol</addtitle><description>Reproducibility and inter‐observer variability of intra‐ and extra‐abdominal umbilical venous flow velocity and left portal venous flow velocity as well as heart‐synchronous waveform pulsations in these vessels were studied in 23 women at 34–38 weeks of normal pregnancy.
Limited reproducibility, expressed by large intra‐patient coefficients and limits of agreement between two observers, was established for all standardized recording sites. Pulsations, defined as negative venous deflections of at least 10% of the mean velocity, were demonstrated at all locations ranging from 19.6% of the measurements at the free‐floating loop of the umbilical vein to 78.4% of the measurements at the left portal vein.
The present study shows that the limited reproducibility of venous flow velocity waveforms should be taken into consideration, and that the presence of pulsations can be demonstrated in normal late pregnancy. Copyright © 1994 International Society of Ultrasound in Obstetrics and Gynecology</description><subject>left portal vein</subject><subject>pulsations</subject><subject>reproducibility</subject><subject>ultrasound</subject><subject>umbilical vein</subject><issn>0960-7692</issn><issn>1469-0705</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><recordid>eNqVkMFq3DAQhkVJabZpXyEYCrnZHcmybNFLQkjSQiA9NGchy6NEiy27kp1koQ8fubttzwWBGOb7Z6SPkE8UCgpcfN4WlAuZQw1VQaXkBXCgAFwWL2_I5m_viGxACshrIdkxeR_jFgAEL8U7ckxZLWvGqg359T1gRG8wG202LX3Usxt9zLTvsoBTGLvFuNb1bt6txLN-QjuGIfXMGDrnHzLns_kRs2VYKaP739Ee7ZxNY5hT_YQJScenXCqngA9ee-MwfiBvre4jfjzcJ-T--urH5df89u7m2-XFbW5KzkXOOGLDbAutabgQVdOytkJjpTBNVfKmgpJRLStRQqM7pLyi3FqwjGtMIsryhJzt56b__Fwwzmpw0WDfa4_jElUt0oC6XsEve9CEMcaAVk3BDTrsFAW1yldbtQpWq2C1yld_5KuXlD49rFnaAbt_2YPtBJzvgWfX4-5_Zqv7uxsq0ztfAUbMldM</recordid><startdate>19940101</startdate><enddate>19940101</enddate><creator>van Splunder, I. P.</creator><creator>Huisman, T. W. A.</creator><creator>Stijnen, T.</creator><creator>Wladimiroff, J. W.</creator><general>Blackwell Science Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19940101</creationdate><title>Presence of pulsations and reproducibility of waveform recording in the umbilical and left portal vein in normal pregnancies</title><author>van Splunder, I. P. ; Huisman, T. W. A. ; Stijnen, T. ; Wladimiroff, J. W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3446-24ee82fb0bc846658b2b5ecf96c8534850321a956308ade14514ff0f24ae70533</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>left portal vein</topic><topic>pulsations</topic><topic>reproducibility</topic><topic>ultrasound</topic><topic>umbilical vein</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>van Splunder, I. P.</creatorcontrib><creatorcontrib>Huisman, T. W. A.</creatorcontrib><creatorcontrib>Stijnen, T.</creatorcontrib><creatorcontrib>Wladimiroff, J. W.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Ultrasound in obstetrics & gynecology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>van Splunder, I. P.</au><au>Huisman, T. W. A.</au><au>Stijnen, T.</au><au>Wladimiroff, J. W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Presence of pulsations and reproducibility of waveform recording in the umbilical and left portal vein in normal pregnancies</atitle><jtitle>Ultrasound in obstetrics & gynecology</jtitle><addtitle>Ultrasound Obstet Gynecol</addtitle><date>1994-01-01</date><risdate>1994</risdate><volume>4</volume><issue>1</issue><spage>49</spage><epage>53</epage><pages>49-53</pages><issn>0960-7692</issn><eissn>1469-0705</eissn><abstract>Reproducibility and inter‐observer variability of intra‐ and extra‐abdominal umbilical venous flow velocity and left portal venous flow velocity as well as heart‐synchronous waveform pulsations in these vessels were studied in 23 women at 34–38 weeks of normal pregnancy.
Limited reproducibility, expressed by large intra‐patient coefficients and limits of agreement between two observers, was established for all standardized recording sites. Pulsations, defined as negative venous deflections of at least 10% of the mean velocity, were demonstrated at all locations ranging from 19.6% of the measurements at the free‐floating loop of the umbilical vein to 78.4% of the measurements at the left portal vein.
The present study shows that the limited reproducibility of venous flow velocity waveforms should be taken into consideration, and that the presence of pulsations can be demonstrated in normal late pregnancy. Copyright © 1994 International Society of Ultrasound in Obstetrics and Gynecology</abstract><cop>Oxford, UK</cop><pub>Blackwell Science Ltd</pub><pmid>12797225</pmid><doi>10.1046/j.1469-0705.1994.04010049.x</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0960-7692 |
ispartof | Ultrasound in obstetrics & gynecology, 1994-01, Vol.4 (1), p.49-53 |
issn | 0960-7692 1469-0705 |
language | eng |
recordid | cdi_proquest_miscellaneous_76321773 |
source | Wiley Online Library Journals Frontfile Complete; EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection |
subjects | left portal vein pulsations reproducibility ultrasound umbilical vein |
title | Presence of pulsations and reproducibility of waveform recording in the umbilical and left portal vein in normal pregnancies |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T11%3A09%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Presence%20of%20pulsations%20and%20reproducibility%20of%20waveform%20recording%20in%20the%20umbilical%20and%20left%20portal%20vein%20in%20normal%20pregnancies&rft.jtitle=Ultrasound%20in%20obstetrics%20&%20gynecology&rft.au=van%20Splunder,%20I.%20P.&rft.date=1994-01-01&rft.volume=4&rft.issue=1&rft.spage=49&rft.epage=53&rft.pages=49-53&rft.issn=0960-7692&rft.eissn=1469-0705&rft_id=info:doi/10.1046/j.1469-0705.1994.04010049.x&rft_dat=%3Cproquest_cross%3E76321773%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=76321773&rft_id=info:pmid/12797225&rfr_iscdi=true |