Short Echo Time Magnetic Resonance Imaging of Tendon

RATIONALE AND OBJECTIVES. Current clinical magnetic resonance (MR) imaging studies provide almost no useful signal from normal tendon and have no clear advantage over other imaging modalities in the evaluation of tendon injuries. The authors believe that tendon MR signal may be T2-limited, and, if s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Investigative radiology 1993-12, Vol.28 (12), p.1095-1100
Hauptverfasser: KOBLIK, PHILIP D, FREEMAN, DOMINIQUE M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1100
container_issue 12
container_start_page 1095
container_title Investigative radiology
container_volume 28
creator KOBLIK, PHILIP D
FREEMAN, DOMINIQUE M
description RATIONALE AND OBJECTIVES. Current clinical magnetic resonance (MR) imaging studies provide almost no useful signal from normal tendon and have no clear advantage over other imaging modalities in the evaluation of tendon injuries. The authors believe that tendon MR signal may be T2-limited, and, if so, could be enhanced by short echo time (TE) pulse sequences. The relationship of tendon signal intensity and tendon infrastructure conspiculty to TE was assessed at three different field strengths.METHODS. Magnetic resonance imaging studies were performed on samples of normal equine tendon at 3 different field strengths with spin-echo or gradient-recalled-echo sequences of varying TE. Tendon signal-to-noise ratios (SNR) were determined for each study and images were evaluated for visual evidence of tendon infrastructure.RESULTS. Tendon SNR demonstrated a strong inverse relationship to TE at each field strength. Signal-to-noise ratio values of 10 to 40 were achieved on the shortest TE studies (TE < 3 msec). Tendon infrastructure could be visualized and was primarily dependent on in-plane resolution and to a lesser extent on SNR.CONCLUSIONS. Short echo time MR imaging enhances tendon signal. Under optimal imaging conditions, tendon infrastructure can be evaluated. As high-performance gradient coil systems become available for clinical imaging systems, the authors believe similar results will be achievable on routine diagnostic studies and foresee an expanding role for MRI in the evaluation of tendon disease.
doi_str_mv 10.1097/00004424-199312000-00003
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_76215390</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>76215390</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4213-f8b1667dba16da0bd582064c6c86a3143deabf0dc05d5046e14d8fba29663df33</originalsourceid><addsrcrecordid>eNp1UU1PwzAMjRBojMFPQMqJW8H5aNoc0TRg0hASjHOUJulaaJuRdJr493Rs7IYvlp-f_eRnhDCBWwIyu4MhOKc8IVIyQocq2UHsBI1JykQClMApGgNQSKSU4hxdxPgxMGgGbIRGOYMsI3SM-FvlQ49npvJ4WbcOP-tV5_ra4FcXfac74_C81au6W2Ff4qXrrO8u0Vmpm-iuDnmC3h9my-lTsnh5nE_vF4nhlLCkzAsiRGYLTYTVUNg0pyC4ESYXmhHOrNNFCdZAalPgwhFu87LQVArBbMnYBN3s966D_9q42Ku2jsY1je6c30SVCTpcK2Eg5nuiCT7G4Eq1DnWrw7cioHaGqT_D1NGwX2incX3Q2BSts8fBg0NDn-_7W9_0LsTPZrN1QVVON32l_vsD-wG-3nO8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>76215390</pqid></control><display><type>article</type><title>Short Echo Time Magnetic Resonance Imaging of Tendon</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>KOBLIK, PHILIP D ; FREEMAN, DOMINIQUE M</creator><creatorcontrib>KOBLIK, PHILIP D ; FREEMAN, DOMINIQUE M</creatorcontrib><description>RATIONALE AND OBJECTIVES. Current clinical magnetic resonance (MR) imaging studies provide almost no useful signal from normal tendon and have no clear advantage over other imaging modalities in the evaluation of tendon injuries. The authors believe that tendon MR signal may be T2-limited, and, if so, could be enhanced by short echo time (TE) pulse sequences. The relationship of tendon signal intensity and tendon infrastructure conspiculty to TE was assessed at three different field strengths.METHODS. Magnetic resonance imaging studies were performed on samples of normal equine tendon at 3 different field strengths with spin-echo or gradient-recalled-echo sequences of varying TE. Tendon signal-to-noise ratios (SNR) were determined for each study and images were evaluated for visual evidence of tendon infrastructure.RESULTS. Tendon SNR demonstrated a strong inverse relationship to TE at each field strength. Signal-to-noise ratio values of 10 to 40 were achieved on the shortest TE studies (TE &lt; 3 msec). Tendon infrastructure could be visualized and was primarily dependent on in-plane resolution and to a lesser extent on SNR.CONCLUSIONS. Short echo time MR imaging enhances tendon signal. Under optimal imaging conditions, tendon infrastructure can be evaluated. As high-performance gradient coil systems become available for clinical imaging systems, the authors believe similar results will be achievable on routine diagnostic studies and foresee an expanding role for MRI in the evaluation of tendon disease.</description><identifier>ISSN: 0020-9996</identifier><identifier>EISSN: 1536-0210</identifier><identifier>DOI: 10.1097/00004424-199312000-00003</identifier><identifier>PMID: 8307712</identifier><language>eng</language><publisher>United States: Lippincott-Raven Publishers</publisher><subject>Animals ; Evaluation Studies as Topic ; Forelimb ; Horses ; In Vitro Techniques ; Magnetic Resonance Imaging - instrumentation ; Magnetic Resonance Imaging - methods ; Reference Values ; Tendons - anatomy &amp; histology ; Time Factors</subject><ispartof>Investigative radiology, 1993-12, Vol.28 (12), p.1095-1100</ispartof><rights>Lippincott-Raven Publishers.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4213-f8b1667dba16da0bd582064c6c86a3143deabf0dc05d5046e14d8fba29663df33</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8307712$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>KOBLIK, PHILIP D</creatorcontrib><creatorcontrib>FREEMAN, DOMINIQUE M</creatorcontrib><title>Short Echo Time Magnetic Resonance Imaging of Tendon</title><title>Investigative radiology</title><addtitle>Invest Radiol</addtitle><description>RATIONALE AND OBJECTIVES. Current clinical magnetic resonance (MR) imaging studies provide almost no useful signal from normal tendon and have no clear advantage over other imaging modalities in the evaluation of tendon injuries. The authors believe that tendon MR signal may be T2-limited, and, if so, could be enhanced by short echo time (TE) pulse sequences. The relationship of tendon signal intensity and tendon infrastructure conspiculty to TE was assessed at three different field strengths.METHODS. Magnetic resonance imaging studies were performed on samples of normal equine tendon at 3 different field strengths with spin-echo or gradient-recalled-echo sequences of varying TE. Tendon signal-to-noise ratios (SNR) were determined for each study and images were evaluated for visual evidence of tendon infrastructure.RESULTS. Tendon SNR demonstrated a strong inverse relationship to TE at each field strength. Signal-to-noise ratio values of 10 to 40 were achieved on the shortest TE studies (TE &lt; 3 msec). Tendon infrastructure could be visualized and was primarily dependent on in-plane resolution and to a lesser extent on SNR.CONCLUSIONS. Short echo time MR imaging enhances tendon signal. Under optimal imaging conditions, tendon infrastructure can be evaluated. As high-performance gradient coil systems become available for clinical imaging systems, the authors believe similar results will be achievable on routine diagnostic studies and foresee an expanding role for MRI in the evaluation of tendon disease.</description><subject>Animals</subject><subject>Evaluation Studies as Topic</subject><subject>Forelimb</subject><subject>Horses</subject><subject>In Vitro Techniques</subject><subject>Magnetic Resonance Imaging - instrumentation</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>Reference Values</subject><subject>Tendons - anatomy &amp; histology</subject><subject>Time Factors</subject><issn>0020-9996</issn><issn>1536-0210</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1993</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1UU1PwzAMjRBojMFPQMqJW8H5aNoc0TRg0hASjHOUJulaaJuRdJr493Rs7IYvlp-f_eRnhDCBWwIyu4MhOKc8IVIyQocq2UHsBI1JykQClMApGgNQSKSU4hxdxPgxMGgGbIRGOYMsI3SM-FvlQ49npvJ4WbcOP-tV5_ra4FcXfac74_C81au6W2Ff4qXrrO8u0Vmpm-iuDnmC3h9my-lTsnh5nE_vF4nhlLCkzAsiRGYLTYTVUNg0pyC4ESYXmhHOrNNFCdZAalPgwhFu87LQVArBbMnYBN3s966D_9q42Ku2jsY1je6c30SVCTpcK2Eg5nuiCT7G4Eq1DnWrw7cioHaGqT_D1NGwX2incX3Q2BSts8fBg0NDn-_7W9_0LsTPZrN1QVVON32l_vsD-wG-3nO8</recordid><startdate>199312</startdate><enddate>199312</enddate><creator>KOBLIK, PHILIP D</creator><creator>FREEMAN, DOMINIQUE M</creator><general>Lippincott-Raven Publishers</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199312</creationdate><title>Short Echo Time Magnetic Resonance Imaging of Tendon</title><author>KOBLIK, PHILIP D ; FREEMAN, DOMINIQUE M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4213-f8b1667dba16da0bd582064c6c86a3143deabf0dc05d5046e14d8fba29663df33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Animals</topic><topic>Evaluation Studies as Topic</topic><topic>Forelimb</topic><topic>Horses</topic><topic>In Vitro Techniques</topic><topic>Magnetic Resonance Imaging - instrumentation</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>Reference Values</topic><topic>Tendons - anatomy &amp; histology</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>KOBLIK, PHILIP D</creatorcontrib><creatorcontrib>FREEMAN, DOMINIQUE M</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Investigative radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>KOBLIK, PHILIP D</au><au>FREEMAN, DOMINIQUE M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Short Echo Time Magnetic Resonance Imaging of Tendon</atitle><jtitle>Investigative radiology</jtitle><addtitle>Invest Radiol</addtitle><date>1993-12</date><risdate>1993</risdate><volume>28</volume><issue>12</issue><spage>1095</spage><epage>1100</epage><pages>1095-1100</pages><issn>0020-9996</issn><eissn>1536-0210</eissn><abstract>RATIONALE AND OBJECTIVES. Current clinical magnetic resonance (MR) imaging studies provide almost no useful signal from normal tendon and have no clear advantage over other imaging modalities in the evaluation of tendon injuries. The authors believe that tendon MR signal may be T2-limited, and, if so, could be enhanced by short echo time (TE) pulse sequences. The relationship of tendon signal intensity and tendon infrastructure conspiculty to TE was assessed at three different field strengths.METHODS. Magnetic resonance imaging studies were performed on samples of normal equine tendon at 3 different field strengths with spin-echo or gradient-recalled-echo sequences of varying TE. Tendon signal-to-noise ratios (SNR) were determined for each study and images were evaluated for visual evidence of tendon infrastructure.RESULTS. Tendon SNR demonstrated a strong inverse relationship to TE at each field strength. Signal-to-noise ratio values of 10 to 40 were achieved on the shortest TE studies (TE &lt; 3 msec). Tendon infrastructure could be visualized and was primarily dependent on in-plane resolution and to a lesser extent on SNR.CONCLUSIONS. Short echo time MR imaging enhances tendon signal. Under optimal imaging conditions, tendon infrastructure can be evaluated. As high-performance gradient coil systems become available for clinical imaging systems, the authors believe similar results will be achievable on routine diagnostic studies and foresee an expanding role for MRI in the evaluation of tendon disease.</abstract><cop>United States</cop><pub>Lippincott-Raven Publishers</pub><pmid>8307712</pmid><doi>10.1097/00004424-199312000-00003</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0020-9996
ispartof Investigative radiology, 1993-12, Vol.28 (12), p.1095-1100
issn 0020-9996
1536-0210
language eng
recordid cdi_proquest_miscellaneous_76215390
source MEDLINE; Journals@Ovid Complete
subjects Animals
Evaluation Studies as Topic
Forelimb
Horses
In Vitro Techniques
Magnetic Resonance Imaging - instrumentation
Magnetic Resonance Imaging - methods
Reference Values
Tendons - anatomy & histology
Time Factors
title Short Echo Time Magnetic Resonance Imaging of Tendon
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-01T20%3A31%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Short%20Echo%20Time%20Magnetic%20Resonance%20Imaging%20of%20Tendon&rft.jtitle=Investigative%20radiology&rft.au=KOBLIK,%20PHILIP%20D&rft.date=1993-12&rft.volume=28&rft.issue=12&rft.spage=1095&rft.epage=1100&rft.pages=1095-1100&rft.issn=0020-9996&rft.eissn=1536-0210&rft_id=info:doi/10.1097/00004424-199312000-00003&rft_dat=%3Cproquest_cross%3E76215390%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=76215390&rft_id=info:pmid/8307712&rfr_iscdi=true