Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound

This paper discusses the effect of blood perfusion on the ablation of rat liver tissue with high-intensity focused ultrasound (HIFU). For this study a practical method has been developed, in which the liver blood flow can be reduced by ligation of the hepatic artery and portal vein. During the treat...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physics in medicine & biology 1993-11, Vol.38 (11), p.1661-1673
Hauptverfasser: Chen, L, Haar, G ter, Hill, C R, Dworkin, M, Carnochan, P, Young, H, Bensted, J P M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1673
container_issue 11
container_start_page 1661
container_title Physics in medicine & biology
container_volume 38
creator Chen, L
Haar, G ter
Hill, C R
Dworkin, M
Carnochan, P
Young, H
Bensted, J P M
description This paper discusses the effect of blood perfusion on the ablation of rat liver tissue with high-intensity focused ultrasound (HIFU). For this study a practical method has been developed, in which the liver blood flow can be reduced by ligation of the hepatic artery and portal vein. During the treatment the rat liver was mobilized out of the abdomen and the blood flow was measured using both the radioactive microsphere method and a laser Doppler blood-flow monitor. The results show that the hepatic blood flow was about 23 ml/100 g min-1 via the hepatic artery and about 227 ml/100 g min-1 via the portal vein. The total liver blood flow was reduced by 98% when both the hepatic artery and portal vein were ligated. Comparative lesions were made on the same liver lobes of rats with both normal and reduced blood flow using a focused ultrasound beam of 1.7 MHz, 67-425 W cm-2 spatially averaged focal intensity ISAL and 2-20 s exposure duration. A marked difference has been found between the lesion dimensions obtained with normal blood flow and that with reduced blood flow. For exposures at 169 W cm-2 the lesion diameter with normal blood flow was reduced by 14% for 3 s exposure duration compared to that obtained with both hepatic artery and portal vein ligated, while the reduction was more than 20% for longer durations.
doi_str_mv 10.1088/0031-9155/38/11/011
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_76145288</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>76145288</sourcerecordid><originalsourceid>FETCH-LOGICAL-c403t-7ab62ec50fc800520f2da1d340dd0bea9621d67c308e9e9c9f7c4d551fe782833</originalsourceid><addsrcrecordid>eNp9kE1r3DAQhkVJSDdJf0Ep6JRDwdmR5A_5WEKaBAK5JGchS6NaxWu5kpyy_z7e7rKXlMCAGN5nXsFDyFcG1wykXAMIVrSsqtZCrhlbA2OfyIqJmhV1VcMJWR2Jz-Q8pd-wEJKXZ-RM8oaXJayIvXUOTabB0W4IwdIJo5uTDyNdJvdIdTfo_G93dPCvGOmkI46m3240_etzT3v_qy_8mHFMPm-pC2ZOaOk85KhTmEd7SU6dHhJ-ObwX5OXn7fPNffH4dPdw8-OxMCWIXDS6qzmaCpyRABUHx61mVpRgLXSo25ozWzdGgMQWW9O6xpS2qpjDRnIpxAW52vdOMfyZMWW18cngMOgRw5xUU7Oy4lIuoNiDJoaUIjo1Rb_RcasYqJ1btTOnduaUkIoxtZhbrr4d6udug_Z4c5C55N_3uQ_TMfxPkZqsW-Dr9_BHv78B9AuQbw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>76145288</pqid></control><display><type>article</type><title>Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound</title><source>MEDLINE</source><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Chen, L ; Haar, G ter ; Hill, C R ; Dworkin, M ; Carnochan, P ; Young, H ; Bensted, J P M</creator><creatorcontrib>Chen, L ; Haar, G ter ; Hill, C R ; Dworkin, M ; Carnochan, P ; Young, H ; Bensted, J P M</creatorcontrib><description>This paper discusses the effect of blood perfusion on the ablation of rat liver tissue with high-intensity focused ultrasound (HIFU). For this study a practical method has been developed, in which the liver blood flow can be reduced by ligation of the hepatic artery and portal vein. During the treatment the rat liver was mobilized out of the abdomen and the blood flow was measured using both the radioactive microsphere method and a laser Doppler blood-flow monitor. The results show that the hepatic blood flow was about 23 ml/100 g min-1 via the hepatic artery and about 227 ml/100 g min-1 via the portal vein. The total liver blood flow was reduced by 98% when both the hepatic artery and portal vein were ligated. Comparative lesions were made on the same liver lobes of rats with both normal and reduced blood flow using a focused ultrasound beam of 1.7 MHz, 67-425 W cm-2 spatially averaged focal intensity ISAL and 2-20 s exposure duration. A marked difference has been found between the lesion dimensions obtained with normal blood flow and that with reduced blood flow. For exposures at 169 W cm-2 the lesion diameter with normal blood flow was reduced by 14% for 3 s exposure duration compared to that obtained with both hepatic artery and portal vein ligated, while the reduction was more than 20% for longer durations.</description><identifier>ISSN: 0031-9155</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/0031-9155/38/11/011</identifier><identifier>PMID: 8272440</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Animals ; Female ; Liver - blood supply ; Medical Laboratory Science ; Rats ; Ultrasonics</subject><ispartof>Physics in medicine &amp; biology, 1993-11, Vol.38 (11), p.1661-1673</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c403t-7ab62ec50fc800520f2da1d340dd0bea9621d67c308e9e9c9f7c4d551fe782833</citedby><cites>FETCH-LOGICAL-c403t-7ab62ec50fc800520f2da1d340dd0bea9621d67c308e9e9c9f7c4d551fe782833</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/0031-9155/38/11/011/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,776,780,27901,27902,53805,53885</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8272440$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Chen, L</creatorcontrib><creatorcontrib>Haar, G ter</creatorcontrib><creatorcontrib>Hill, C R</creatorcontrib><creatorcontrib>Dworkin, M</creatorcontrib><creatorcontrib>Carnochan, P</creatorcontrib><creatorcontrib>Young, H</creatorcontrib><creatorcontrib>Bensted, J P M</creatorcontrib><title>Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound</title><title>Physics in medicine &amp; biology</title><addtitle>Phys Med Biol</addtitle><description>This paper discusses the effect of blood perfusion on the ablation of rat liver tissue with high-intensity focused ultrasound (HIFU). For this study a practical method has been developed, in which the liver blood flow can be reduced by ligation of the hepatic artery and portal vein. During the treatment the rat liver was mobilized out of the abdomen and the blood flow was measured using both the radioactive microsphere method and a laser Doppler blood-flow monitor. The results show that the hepatic blood flow was about 23 ml/100 g min-1 via the hepatic artery and about 227 ml/100 g min-1 via the portal vein. The total liver blood flow was reduced by 98% when both the hepatic artery and portal vein were ligated. Comparative lesions were made on the same liver lobes of rats with both normal and reduced blood flow using a focused ultrasound beam of 1.7 MHz, 67-425 W cm-2 spatially averaged focal intensity ISAL and 2-20 s exposure duration. A marked difference has been found between the lesion dimensions obtained with normal blood flow and that with reduced blood flow. For exposures at 169 W cm-2 the lesion diameter with normal blood flow was reduced by 14% for 3 s exposure duration compared to that obtained with both hepatic artery and portal vein ligated, while the reduction was more than 20% for longer durations.</description><subject>Animals</subject><subject>Female</subject><subject>Liver - blood supply</subject><subject>Medical Laboratory Science</subject><subject>Rats</subject><subject>Ultrasonics</subject><issn>0031-9155</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1993</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE1r3DAQhkVJSDdJf0Ep6JRDwdmR5A_5WEKaBAK5JGchS6NaxWu5kpyy_z7e7rKXlMCAGN5nXsFDyFcG1wykXAMIVrSsqtZCrhlbA2OfyIqJmhV1VcMJWR2Jz-Q8pd-wEJKXZ-RM8oaXJayIvXUOTabB0W4IwdIJo5uTDyNdJvdIdTfo_G93dPCvGOmkI46m3240_etzT3v_qy_8mHFMPm-pC2ZOaOk85KhTmEd7SU6dHhJ-ObwX5OXn7fPNffH4dPdw8-OxMCWIXDS6qzmaCpyRABUHx61mVpRgLXSo25ozWzdGgMQWW9O6xpS2qpjDRnIpxAW52vdOMfyZMWW18cngMOgRw5xUU7Oy4lIuoNiDJoaUIjo1Rb_RcasYqJ1btTOnduaUkIoxtZhbrr4d6udug_Z4c5C55N_3uQ_TMfxPkZqsW-Dr9_BHv78B9AuQbw</recordid><startdate>19931101</startdate><enddate>19931101</enddate><creator>Chen, L</creator><creator>Haar, G ter</creator><creator>Hill, C R</creator><creator>Dworkin, M</creator><creator>Carnochan, P</creator><creator>Young, H</creator><creator>Bensted, J P M</creator><general>IOP Publishing</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19931101</creationdate><title>Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound</title><author>Chen, L ; Haar, G ter ; Hill, C R ; Dworkin, M ; Carnochan, P ; Young, H ; Bensted, J P M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c403t-7ab62ec50fc800520f2da1d340dd0bea9621d67c308e9e9c9f7c4d551fe782833</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Animals</topic><topic>Female</topic><topic>Liver - blood supply</topic><topic>Medical Laboratory Science</topic><topic>Rats</topic><topic>Ultrasonics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chen, L</creatorcontrib><creatorcontrib>Haar, G ter</creatorcontrib><creatorcontrib>Hill, C R</creatorcontrib><creatorcontrib>Dworkin, M</creatorcontrib><creatorcontrib>Carnochan, P</creatorcontrib><creatorcontrib>Young, H</creatorcontrib><creatorcontrib>Bensted, J P M</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physics in medicine &amp; biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chen, L</au><au>Haar, G ter</au><au>Hill, C R</au><au>Dworkin, M</au><au>Carnochan, P</au><au>Young, H</au><au>Bensted, J P M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound</atitle><jtitle>Physics in medicine &amp; biology</jtitle><addtitle>Phys Med Biol</addtitle><date>1993-11-01</date><risdate>1993</risdate><volume>38</volume><issue>11</issue><spage>1661</spage><epage>1673</epage><pages>1661-1673</pages><issn>0031-9155</issn><eissn>1361-6560</eissn><abstract>This paper discusses the effect of blood perfusion on the ablation of rat liver tissue with high-intensity focused ultrasound (HIFU). For this study a practical method has been developed, in which the liver blood flow can be reduced by ligation of the hepatic artery and portal vein. During the treatment the rat liver was mobilized out of the abdomen and the blood flow was measured using both the radioactive microsphere method and a laser Doppler blood-flow monitor. The results show that the hepatic blood flow was about 23 ml/100 g min-1 via the hepatic artery and about 227 ml/100 g min-1 via the portal vein. The total liver blood flow was reduced by 98% when both the hepatic artery and portal vein were ligated. Comparative lesions were made on the same liver lobes of rats with both normal and reduced blood flow using a focused ultrasound beam of 1.7 MHz, 67-425 W cm-2 spatially averaged focal intensity ISAL and 2-20 s exposure duration. A marked difference has been found between the lesion dimensions obtained with normal blood flow and that with reduced blood flow. For exposures at 169 W cm-2 the lesion diameter with normal blood flow was reduced by 14% for 3 s exposure duration compared to that obtained with both hepatic artery and portal vein ligated, while the reduction was more than 20% for longer durations.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>8272440</pmid><doi>10.1088/0031-9155/38/11/011</doi><tpages>13</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0031-9155
ispartof Physics in medicine & biology, 1993-11, Vol.38 (11), p.1661-1673
issn 0031-9155
1361-6560
language eng
recordid cdi_proquest_miscellaneous_76145288
source MEDLINE; IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects Animals
Female
Liver - blood supply
Medical Laboratory Science
Rats
Ultrasonics
title Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T13%3A10%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20blood%20perfusion%20on%20the%20ablation%20of%20liver%20parenchyma%20with%20high-intensity%20focused%20ultrasound&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=Chen,%20L&rft.date=1993-11-01&rft.volume=38&rft.issue=11&rft.spage=1661&rft.epage=1673&rft.pages=1661-1673&rft.issn=0031-9155&rft.eissn=1361-6560&rft_id=info:doi/10.1088/0031-9155/38/11/011&rft_dat=%3Cproquest_pubme%3E76145288%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=76145288&rft_id=info:pmid/8272440&rfr_iscdi=true