A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction

The purpose of this study was to compare the subjective image quality, image noise, and radiation dose of chest CT images reconstructed with a 30% blend of iterative reconstruction and 70% conventional filtered back projection (FBP) with those of images generated with 100% FBP. Clinically indicated...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of roentgenology (1976) 2010-11, Vol.195 (5), p.1095-1099
Hauptverfasser: LEIPSIC, Jonathon, NGUYEN, Giang, BROWN, Jaqueline, SIN, Don, MAYO, John R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1099
container_issue 5
container_start_page 1095
container_title American journal of roentgenology (1976)
container_volume 195
creator LEIPSIC, Jonathon
NGUYEN, Giang
BROWN, Jaqueline
SIN, Don
MAYO, John R
description The purpose of this study was to compare the subjective image quality, image noise, and radiation dose of chest CT images reconstructed with a 30% blend of iterative reconstruction and 70% conventional filtered back projection (FBP) with those of images generated with 100% FBP. Clinically indicated chest CT examinations of 292 consecutively registered patients were prospectively alternately assigned to two scanners on which different reconstruction techniques were used: adaptive statistical iterative reconstruction (ASIR) blended with FBP and 100% FBP. Both acquisitions were performed with dose modulation (noise index, 25 for ASIR and 21 for FBP). Patient demographics and habitus were recorded. Two radiologists blinded to the reconstruction algorithm independently scored subjective image quality on a 3-point Likert scale and measured image noise and radiation dose. Compared with FBP images, ASIR images had significantly lower subjective image quality (p = 0.01), less image noise (p = 0.02), and less radiation dose (p < 0.0001). The CT dose index of the ASIR cohort (11.3 ± 51) was significantly lower than that of the 100% FBP cohort (15.4 ± 6.3) (p < 0.0001). Interobserver agreement on subjective image quality was excellent for both ASIR and FBP (Cronbach α, 0.92, p < 0.0001; Cronbach α, 0.85, p < 0.0001). In clinically indicated chest CT examinations, ASIR images had better image quality and less image noise at a lower radiation dose than images acquired with a conventional FBP reconstruction algorithm.
doi_str_mv 10.2214/ajr.09.4050
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_759877624</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>759877624</sourcerecordid><originalsourceid>FETCH-LOGICAL-c384t-a7ce95abf9e1f0bf49f5c3b13c17887841928abeac06a5b760387385999a25d33</originalsourceid><addsrcrecordid>eNpFkM9LwzAUgIMobv44eZdcxIN0Jk3aJMcxp04EdSp4K69pOiNdO5N0IPjH2_1Q3-XB4-Pj8SF0Qskgjim_hA83IGrASUJ2UJ8mPI0Y5XQX9QlLaSQJe-uhA-8_CCFCKrGPejFRacpo3EffQ_zoGr8wOtilweMlVC0E29S4KfFV4w2emqLV6wvUBZ7MYWbwUwuVDV_Y1nj0bnzAoxf86m09w8MCFmvTc-g0PlgNFZ4E42B9nRrd1D64jfEI7ZVQeXO83Yfo9Xr8MrqN7h9uJqPhfaSZ5CECoY1KIC-VoSXJS67KRLOcMk2FlEJyqmIJuQFNUkhykRImBZOJUgripGDsEJ1vvAvXfLbdv9ncem2qCmrTtD4TiZJCpDHvyIsNqbso3pkyWzg7B_eVUZKtamfDu2lGVLaq3dGnW2-bz03xx_7m7YCzLQC-C1E6qLX1_xxjXLBufgAXUoho</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>759877624</pqid></control><display><type>article</type><title>A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction</title><source>American Roentgen Ray Society</source><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>LEIPSIC, Jonathon ; NGUYEN, Giang ; BROWN, Jaqueline ; SIN, Don ; MAYO, John R</creator><creatorcontrib>LEIPSIC, Jonathon ; NGUYEN, Giang ; BROWN, Jaqueline ; SIN, Don ; MAYO, John R</creatorcontrib><description>The purpose of this study was to compare the subjective image quality, image noise, and radiation dose of chest CT images reconstructed with a 30% blend of iterative reconstruction and 70% conventional filtered back projection (FBP) with those of images generated with 100% FBP. Clinically indicated chest CT examinations of 292 consecutively registered patients were prospectively alternately assigned to two scanners on which different reconstruction techniques were used: adaptive statistical iterative reconstruction (ASIR) blended with FBP and 100% FBP. Both acquisitions were performed with dose modulation (noise index, 25 for ASIR and 21 for FBP). Patient demographics and habitus were recorded. Two radiologists blinded to the reconstruction algorithm independently scored subjective image quality on a 3-point Likert scale and measured image noise and radiation dose. Compared with FBP images, ASIR images had significantly lower subjective image quality (p = 0.01), less image noise (p = 0.02), and less radiation dose (p &lt; 0.0001). The CT dose index of the ASIR cohort (11.3 ± 51) was significantly lower than that of the 100% FBP cohort (15.4 ± 6.3) (p &lt; 0.0001). Interobserver agreement on subjective image quality was excellent for both ASIR and FBP (Cronbach α, 0.92, p &lt; 0.0001; Cronbach α, 0.85, p &lt; 0.0001). In clinically indicated chest CT examinations, ASIR images had better image quality and less image noise at a lower radiation dose than images acquired with a conventional FBP reconstruction algorithm.</description><identifier>ISSN: 0361-803X</identifier><identifier>EISSN: 1546-3141</identifier><identifier>DOI: 10.2214/ajr.09.4050</identifier><identifier>PMID: 20966312</identifier><identifier>CODEN: AAJRDX</identifier><language>eng</language><publisher>Reston, VA: American Roentgen Ray Society</publisher><subject>Algorithms ; Biological and medical sciences ; Female ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Linear Models ; Male ; Medical sciences ; Middle Aged ; Prospective Studies ; Radiation Dosage ; Radiodiagnosis. Nmr imagery. Nmr spectrometry ; Radiographic Image Interpretation, Computer-Assisted - methods ; Radiography, Thoracic - methods ; Respiratory system ; Tomography, X-Ray Computed - methods</subject><ispartof>American journal of roentgenology (1976), 2010-11, Vol.195 (5), p.1095-1099</ispartof><rights>2015 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c384t-a7ce95abf9e1f0bf49f5c3b13c17887841928abeac06a5b760387385999a25d33</citedby><cites>FETCH-LOGICAL-c384t-a7ce95abf9e1f0bf49f5c3b13c17887841928abeac06a5b760387385999a25d33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,4106,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=23347333$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20966312$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>LEIPSIC, Jonathon</creatorcontrib><creatorcontrib>NGUYEN, Giang</creatorcontrib><creatorcontrib>BROWN, Jaqueline</creatorcontrib><creatorcontrib>SIN, Don</creatorcontrib><creatorcontrib>MAYO, John R</creatorcontrib><title>A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction</title><title>American journal of roentgenology (1976)</title><addtitle>AJR Am J Roentgenol</addtitle><description>The purpose of this study was to compare the subjective image quality, image noise, and radiation dose of chest CT images reconstructed with a 30% blend of iterative reconstruction and 70% conventional filtered back projection (FBP) with those of images generated with 100% FBP. Clinically indicated chest CT examinations of 292 consecutively registered patients were prospectively alternately assigned to two scanners on which different reconstruction techniques were used: adaptive statistical iterative reconstruction (ASIR) blended with FBP and 100% FBP. Both acquisitions were performed with dose modulation (noise index, 25 for ASIR and 21 for FBP). Patient demographics and habitus were recorded. Two radiologists blinded to the reconstruction algorithm independently scored subjective image quality on a 3-point Likert scale and measured image noise and radiation dose. Compared with FBP images, ASIR images had significantly lower subjective image quality (p = 0.01), less image noise (p = 0.02), and less radiation dose (p &lt; 0.0001). The CT dose index of the ASIR cohort (11.3 ± 51) was significantly lower than that of the 100% FBP cohort (15.4 ± 6.3) (p &lt; 0.0001). Interobserver agreement on subjective image quality was excellent for both ASIR and FBP (Cronbach α, 0.92, p &lt; 0.0001; Cronbach α, 0.85, p &lt; 0.0001). In clinically indicated chest CT examinations, ASIR images had better image quality and less image noise at a lower radiation dose than images acquired with a conventional FBP reconstruction algorithm.</description><subject>Algorithms</subject><subject>Biological and medical sciences</subject><subject>Female</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Linear Models</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Prospective Studies</subject><subject>Radiation Dosage</subject><subject>Radiodiagnosis. Nmr imagery. Nmr spectrometry</subject><subject>Radiographic Image Interpretation, Computer-Assisted - methods</subject><subject>Radiography, Thoracic - methods</subject><subject>Respiratory system</subject><subject>Tomography, X-Ray Computed - methods</subject><issn>0361-803X</issn><issn>1546-3141</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkM9LwzAUgIMobv44eZdcxIN0Jk3aJMcxp04EdSp4K69pOiNdO5N0IPjH2_1Q3-XB4-Pj8SF0Qskgjim_hA83IGrASUJ2UJ8mPI0Y5XQX9QlLaSQJe-uhA-8_CCFCKrGPejFRacpo3EffQ_zoGr8wOtilweMlVC0E29S4KfFV4w2emqLV6wvUBZ7MYWbwUwuVDV_Y1nj0bnzAoxf86m09w8MCFmvTc-g0PlgNFZ4E42B9nRrd1D64jfEI7ZVQeXO83Yfo9Xr8MrqN7h9uJqPhfaSZ5CECoY1KIC-VoSXJS67KRLOcMk2FlEJyqmIJuQFNUkhykRImBZOJUgripGDsEJ1vvAvXfLbdv9ncem2qCmrTtD4TiZJCpDHvyIsNqbso3pkyWzg7B_eVUZKtamfDu2lGVLaq3dGnW2-bz03xx_7m7YCzLQC-C1E6qLX1_xxjXLBufgAXUoho</recordid><startdate>20101101</startdate><enddate>20101101</enddate><creator>LEIPSIC, Jonathon</creator><creator>NGUYEN, Giang</creator><creator>BROWN, Jaqueline</creator><creator>SIN, Don</creator><creator>MAYO, John R</creator><general>American Roentgen Ray Society</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20101101</creationdate><title>A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction</title><author>LEIPSIC, Jonathon ; NGUYEN, Giang ; BROWN, Jaqueline ; SIN, Don ; MAYO, John R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c384t-a7ce95abf9e1f0bf49f5c3b13c17887841928abeac06a5b760387385999a25d33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Algorithms</topic><topic>Biological and medical sciences</topic><topic>Female</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Linear Models</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Prospective Studies</topic><topic>Radiation Dosage</topic><topic>Radiodiagnosis. Nmr imagery. Nmr spectrometry</topic><topic>Radiographic Image Interpretation, Computer-Assisted - methods</topic><topic>Radiography, Thoracic - methods</topic><topic>Respiratory system</topic><topic>Tomography, X-Ray Computed - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>LEIPSIC, Jonathon</creatorcontrib><creatorcontrib>NGUYEN, Giang</creatorcontrib><creatorcontrib>BROWN, Jaqueline</creatorcontrib><creatorcontrib>SIN, Don</creatorcontrib><creatorcontrib>MAYO, John R</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>American journal of roentgenology (1976)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>LEIPSIC, Jonathon</au><au>NGUYEN, Giang</au><au>BROWN, Jaqueline</au><au>SIN, Don</au><au>MAYO, John R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction</atitle><jtitle>American journal of roentgenology (1976)</jtitle><addtitle>AJR Am J Roentgenol</addtitle><date>2010-11-01</date><risdate>2010</risdate><volume>195</volume><issue>5</issue><spage>1095</spage><epage>1099</epage><pages>1095-1099</pages><issn>0361-803X</issn><eissn>1546-3141</eissn><coden>AAJRDX</coden><abstract>The purpose of this study was to compare the subjective image quality, image noise, and radiation dose of chest CT images reconstructed with a 30% blend of iterative reconstruction and 70% conventional filtered back projection (FBP) with those of images generated with 100% FBP. Clinically indicated chest CT examinations of 292 consecutively registered patients were prospectively alternately assigned to two scanners on which different reconstruction techniques were used: adaptive statistical iterative reconstruction (ASIR) blended with FBP and 100% FBP. Both acquisitions were performed with dose modulation (noise index, 25 for ASIR and 21 for FBP). Patient demographics and habitus were recorded. Two radiologists blinded to the reconstruction algorithm independently scored subjective image quality on a 3-point Likert scale and measured image noise and radiation dose. Compared with FBP images, ASIR images had significantly lower subjective image quality (p = 0.01), less image noise (p = 0.02), and less radiation dose (p &lt; 0.0001). The CT dose index of the ASIR cohort (11.3 ± 51) was significantly lower than that of the 100% FBP cohort (15.4 ± 6.3) (p &lt; 0.0001). Interobserver agreement on subjective image quality was excellent for both ASIR and FBP (Cronbach α, 0.92, p &lt; 0.0001; Cronbach α, 0.85, p &lt; 0.0001). In clinically indicated chest CT examinations, ASIR images had better image quality and less image noise at a lower radiation dose than images acquired with a conventional FBP reconstruction algorithm.</abstract><cop>Reston, VA</cop><pub>American Roentgen Ray Society</pub><pmid>20966312</pmid><doi>10.2214/ajr.09.4050</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0361-803X
ispartof American journal of roentgenology (1976), 2010-11, Vol.195 (5), p.1095-1099
issn 0361-803X
1546-3141
language eng
recordid cdi_proquest_miscellaneous_759877624
source American Roentgen Ray Society; MEDLINE; Alma/SFX Local Collection
subjects Algorithms
Biological and medical sciences
Female
Humans
Investigative techniques, diagnostic techniques (general aspects)
Linear Models
Male
Medical sciences
Middle Aged
Prospective Studies
Radiation Dosage
Radiodiagnosis. Nmr imagery. Nmr spectrometry
Radiographic Image Interpretation, Computer-Assisted - methods
Radiography, Thoracic - methods
Respiratory system
Tomography, X-Ray Computed - methods
title A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-01T18%3A04%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Prospective%20Evaluation%20of%20Dose%20Reduction%20and%20Image%20Quality%20in%20Chest%20CT%20Using%20Adaptive%20Statistical%20Iterative%20Reconstruction&rft.jtitle=American%20journal%20of%20roentgenology%20(1976)&rft.au=LEIPSIC,%20Jonathon&rft.date=2010-11-01&rft.volume=195&rft.issue=5&rft.spage=1095&rft.epage=1099&rft.pages=1095-1099&rft.issn=0361-803X&rft.eissn=1546-3141&rft.coden=AAJRDX&rft_id=info:doi/10.2214/ajr.09.4050&rft_dat=%3Cproquest_cross%3E759877624%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=759877624&rft_id=info:pmid/20966312&rfr_iscdi=true