In-Vitro Assessment of the Behavior of Magnetic Resonance Angiography in the Presence of Constrictions

Sebok NK, Sebok DA, Wilkerson D, Mezrich RS, Zatina M. In-vitro assessment of the behavior of magnetic resonance angiography in the presence of constrictions. Invest Radiol 1993; 28:604-610. RATIONALE AND OBJECTIVES.Timc-of-flight magnetic resonance angiography (TOF/MRA) is increasingly used to asse...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Investigative radiology 1993-07, Vol.28 (7), p.604-610
Hauptverfasser: SEBOK, NANCY R, SEBOK, DAVID A, WILKERSON, DONALD, MEZRICH, REUBEN S, ZATINA, MICHAEL
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 610
container_issue 7
container_start_page 604
container_title Investigative radiology
container_volume 28
creator SEBOK, NANCY R
SEBOK, DAVID A
WILKERSON, DONALD
MEZRICH, REUBEN S
ZATINA, MICHAEL
description Sebok NK, Sebok DA, Wilkerson D, Mezrich RS, Zatina M. In-vitro assessment of the behavior of magnetic resonance angiography in the presence of constrictions. Invest Radiol 1993; 28:604-610. RATIONALE AND OBJECTIVES.Timc-of-flight magnetic resonance angiography (TOF/MRA) is increasingly used to assess the nature and severity of stenotic blood vessels. Flow artifacts associated with high flows and/or narrow constrictions may confuse the interpretation of these studies. Accurate TOF/MRA evaluations demand an understanding of the nature of these flow effects. METHODS.A two-dimensional TOF pulse sequence was used to acquire images of five smoothly constricted phantoms at various flows. Analysis included, assessment of phantom appearance and quantification of apparent constriction diameter and signal variations. RESULTS.Most notable flow phenomena were a cone-shaped region of high signal, a region of signal void, and signal preservation along the wall. When visible, constriction diameter was accurately measured. CONCLUSIONS.The behavior observed in TOF/MRA images can be understood by considering the contributing mechanisms of phase dispersion, turbulence, poststenotic flow eddies, flow reversal, and flow separation.
doi_str_mv 10.1097/00004424-199307000-00011
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_75888391</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>75888391</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3551-f82a084de4ad03154a43365cb45d8828f47c4dd900551f4f2b1706f8b687b9133</originalsourceid><addsrcrecordid>eNp1kUFP4zAQha0VKyiFn7BSTtyyjGMncY6lAhYJBELsXi0nGTeG1C62S8W_X5cWblga2aP33lj6hpCMwm8KTX0O6XBe8Jw2DYM6dXkqSn-QCS1ZlUNB4YBMAArIm6apjshxCM_JUtTADsmhYJwLChOib2z-z0TvslkIGMISbcyczuKA2QUO6s04v-3v1MJiNF32iMFZZTvMZnZh3MKr1fCeGfuRePAYcKulxNzZEL3pokmPE_JTqzHg6f6ekr9Xl0_zP_nt_fXNfHabd6wsaa5FoUDwHrnqgdGSK85YVXYtL3shCqF53fG-bwCSW3NdtLSGSou2EnXbUMam5Gw3d-Xd6xpDlEsTOhxHZdGtg6xLIQRLzikRO2PnXQgetVx5s1T-XVKQW8TyE7H8Qiw_EKfor_0f63aJ_VdwzzTpfKdv3BjRh5dxvUEvB1RjHOR3m2P_Afuxhb8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>75888391</pqid></control><display><type>article</type><title>In-Vitro Assessment of the Behavior of Magnetic Resonance Angiography in the Presence of Constrictions</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>SEBOK, NANCY R ; SEBOK, DAVID A ; WILKERSON, DONALD ; MEZRICH, REUBEN S ; ZATINA, MICHAEL</creator><creatorcontrib>SEBOK, NANCY R ; SEBOK, DAVID A ; WILKERSON, DONALD ; MEZRICH, REUBEN S ; ZATINA, MICHAEL</creatorcontrib><description>Sebok NK, Sebok DA, Wilkerson D, Mezrich RS, Zatina M. In-vitro assessment of the behavior of magnetic resonance angiography in the presence of constrictions. Invest Radiol 1993; 28:604-610. RATIONALE AND OBJECTIVES.Timc-of-flight magnetic resonance angiography (TOF/MRA) is increasingly used to assess the nature and severity of stenotic blood vessels. Flow artifacts associated with high flows and/or narrow constrictions may confuse the interpretation of these studies. Accurate TOF/MRA evaluations demand an understanding of the nature of these flow effects. METHODS.A two-dimensional TOF pulse sequence was used to acquire images of five smoothly constricted phantoms at various flows. Analysis included, assessment of phantom appearance and quantification of apparent constriction diameter and signal variations. RESULTS.Most notable flow phenomena were a cone-shaped region of high signal, a region of signal void, and signal preservation along the wall. When visible, constriction diameter was accurately measured. CONCLUSIONS.The behavior observed in TOF/MRA images can be understood by considering the contributing mechanisms of phase dispersion, turbulence, poststenotic flow eddies, flow reversal, and flow separation.</description><identifier>ISSN: 0020-9996</identifier><identifier>EISSN: 1536-0210</identifier><identifier>DOI: 10.1097/00004424-199307000-00011</identifier><identifier>PMID: 8344810</identifier><language>eng</language><publisher>United States: Lippincott-Raven Publishers</publisher><subject>Blood Vessels - pathology ; Constriction ; In Vitro Techniques ; Magnetic Resonance Imaging ; Models, Structural</subject><ispartof>Investigative radiology, 1993-07, Vol.28 (7), p.604-610</ispartof><rights>Lippincott-Raven Publishers.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3551-f82a084de4ad03154a43365cb45d8828f47c4dd900551f4f2b1706f8b687b9133</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8344810$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>SEBOK, NANCY R</creatorcontrib><creatorcontrib>SEBOK, DAVID A</creatorcontrib><creatorcontrib>WILKERSON, DONALD</creatorcontrib><creatorcontrib>MEZRICH, REUBEN S</creatorcontrib><creatorcontrib>ZATINA, MICHAEL</creatorcontrib><title>In-Vitro Assessment of the Behavior of Magnetic Resonance Angiography in the Presence of Constrictions</title><title>Investigative radiology</title><addtitle>Invest Radiol</addtitle><description>Sebok NK, Sebok DA, Wilkerson D, Mezrich RS, Zatina M. In-vitro assessment of the behavior of magnetic resonance angiography in the presence of constrictions. Invest Radiol 1993; 28:604-610. RATIONALE AND OBJECTIVES.Timc-of-flight magnetic resonance angiography (TOF/MRA) is increasingly used to assess the nature and severity of stenotic blood vessels. Flow artifacts associated with high flows and/or narrow constrictions may confuse the interpretation of these studies. Accurate TOF/MRA evaluations demand an understanding of the nature of these flow effects. METHODS.A two-dimensional TOF pulse sequence was used to acquire images of five smoothly constricted phantoms at various flows. Analysis included, assessment of phantom appearance and quantification of apparent constriction diameter and signal variations. RESULTS.Most notable flow phenomena were a cone-shaped region of high signal, a region of signal void, and signal preservation along the wall. When visible, constriction diameter was accurately measured. CONCLUSIONS.The behavior observed in TOF/MRA images can be understood by considering the contributing mechanisms of phase dispersion, turbulence, poststenotic flow eddies, flow reversal, and flow separation.</description><subject>Blood Vessels - pathology</subject><subject>Constriction</subject><subject>In Vitro Techniques</subject><subject>Magnetic Resonance Imaging</subject><subject>Models, Structural</subject><issn>0020-9996</issn><issn>1536-0210</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1993</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kUFP4zAQha0VKyiFn7BSTtyyjGMncY6lAhYJBELsXi0nGTeG1C62S8W_X5cWblga2aP33lj6hpCMwm8KTX0O6XBe8Jw2DYM6dXkqSn-QCS1ZlUNB4YBMAArIm6apjshxCM_JUtTADsmhYJwLChOib2z-z0TvslkIGMISbcyczuKA2QUO6s04v-3v1MJiNF32iMFZZTvMZnZh3MKr1fCeGfuRePAYcKulxNzZEL3pokmPE_JTqzHg6f6ekr9Xl0_zP_nt_fXNfHabd6wsaa5FoUDwHrnqgdGSK85YVXYtL3shCqF53fG-bwCSW3NdtLSGSou2EnXbUMam5Gw3d-Xd6xpDlEsTOhxHZdGtg6xLIQRLzikRO2PnXQgetVx5s1T-XVKQW8TyE7H8Qiw_EKfor_0f63aJ_VdwzzTpfKdv3BjRh5dxvUEvB1RjHOR3m2P_Afuxhb8</recordid><startdate>199307</startdate><enddate>199307</enddate><creator>SEBOK, NANCY R</creator><creator>SEBOK, DAVID A</creator><creator>WILKERSON, DONALD</creator><creator>MEZRICH, REUBEN S</creator><creator>ZATINA, MICHAEL</creator><general>Lippincott-Raven Publishers</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199307</creationdate><title>In-Vitro Assessment of the Behavior of Magnetic Resonance Angiography in the Presence of Constrictions</title><author>SEBOK, NANCY R ; SEBOK, DAVID A ; WILKERSON, DONALD ; MEZRICH, REUBEN S ; ZATINA, MICHAEL</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3551-f82a084de4ad03154a43365cb45d8828f47c4dd900551f4f2b1706f8b687b9133</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Blood Vessels - pathology</topic><topic>Constriction</topic><topic>In Vitro Techniques</topic><topic>Magnetic Resonance Imaging</topic><topic>Models, Structural</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>SEBOK, NANCY R</creatorcontrib><creatorcontrib>SEBOK, DAVID A</creatorcontrib><creatorcontrib>WILKERSON, DONALD</creatorcontrib><creatorcontrib>MEZRICH, REUBEN S</creatorcontrib><creatorcontrib>ZATINA, MICHAEL</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Investigative radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>SEBOK, NANCY R</au><au>SEBOK, DAVID A</au><au>WILKERSON, DONALD</au><au>MEZRICH, REUBEN S</au><au>ZATINA, MICHAEL</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>In-Vitro Assessment of the Behavior of Magnetic Resonance Angiography in the Presence of Constrictions</atitle><jtitle>Investigative radiology</jtitle><addtitle>Invest Radiol</addtitle><date>1993-07</date><risdate>1993</risdate><volume>28</volume><issue>7</issue><spage>604</spage><epage>610</epage><pages>604-610</pages><issn>0020-9996</issn><eissn>1536-0210</eissn><abstract>Sebok NK, Sebok DA, Wilkerson D, Mezrich RS, Zatina M. In-vitro assessment of the behavior of magnetic resonance angiography in the presence of constrictions. Invest Radiol 1993; 28:604-610. RATIONALE AND OBJECTIVES.Timc-of-flight magnetic resonance angiography (TOF/MRA) is increasingly used to assess the nature and severity of stenotic blood vessels. Flow artifacts associated with high flows and/or narrow constrictions may confuse the interpretation of these studies. Accurate TOF/MRA evaluations demand an understanding of the nature of these flow effects. METHODS.A two-dimensional TOF pulse sequence was used to acquire images of five smoothly constricted phantoms at various flows. Analysis included, assessment of phantom appearance and quantification of apparent constriction diameter and signal variations. RESULTS.Most notable flow phenomena were a cone-shaped region of high signal, a region of signal void, and signal preservation along the wall. When visible, constriction diameter was accurately measured. CONCLUSIONS.The behavior observed in TOF/MRA images can be understood by considering the contributing mechanisms of phase dispersion, turbulence, poststenotic flow eddies, flow reversal, and flow separation.</abstract><cop>United States</cop><pub>Lippincott-Raven Publishers</pub><pmid>8344810</pmid><doi>10.1097/00004424-199307000-00011</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0020-9996
ispartof Investigative radiology, 1993-07, Vol.28 (7), p.604-610
issn 0020-9996
1536-0210
language eng
recordid cdi_proquest_miscellaneous_75888391
source MEDLINE; Journals@Ovid Complete
subjects Blood Vessels - pathology
Constriction
In Vitro Techniques
Magnetic Resonance Imaging
Models, Structural
title In-Vitro Assessment of the Behavior of Magnetic Resonance Angiography in the Presence of Constrictions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T18%3A02%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=In-Vitro%20Assessment%20of%20the%20Behavior%20of%20Magnetic%20Resonance%20Angiography%20in%20the%20Presence%20of%20Constrictions&rft.jtitle=Investigative%20radiology&rft.au=SEBOK,%20NANCY%20R&rft.date=1993-07&rft.volume=28&rft.issue=7&rft.spage=604&rft.epage=610&rft.pages=604-610&rft.issn=0020-9996&rft.eissn=1536-0210&rft_id=info:doi/10.1097/00004424-199307000-00011&rft_dat=%3Cproquest_cross%3E75888391%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=75888391&rft_id=info:pmid/8344810&rfr_iscdi=true