Identification of two different rate-limiting mechanisms controlling the release of NSAIDs from silastic polymeric devices, and possible implications

Two different rate-limiting mechanisms have been found by examining the release characteristics of meclofenamic acid, BW755C.hydrochloride, and diclofenac sodium from silastic polymeric rods into phosphate (0.1 M, pH 7.3) at 37°C. Experiments were performed using rods with initial drug concentration...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Prostaglandins, leukotrienes and essential fatty acids leukotrienes and essential fatty acids, 1993-05, Vol.48 (5), p.391-395
1. Verfasser: Peplow, P.V.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 395
container_issue 5
container_start_page 391
container_title Prostaglandins, leukotrienes and essential fatty acids
container_volume 48
creator Peplow, P.V.
description Two different rate-limiting mechanisms have been found by examining the release characteristics of meclofenamic acid, BW755C.hydrochloride, and diclofenac sodium from silastic polymeric rods into phosphate (0.1 M, pH 7.3) at 37°C. Experiments were performed using rods with initial drug concentrations of 3, 6 and 9% w/w and plots of Q-t and Q-t 1 2 were made (Q, cumulative amount of drug released into solution; t, time). For each of the three loadings of meclofenamic acid, the Q-t 1 2 plot was linear which indicated a matrix controlled release of the drug. With diclofenac sodium, each of the three loadings gave a Q-t plot that was linear thereby indicating a partition controlled release of this drug. For BW755C.HCl, the release of the drug from rods at the two lowest loadings was matrix controlled, but release from rods at the highest loading was partition controlled. The possible implications of these findings are discussed in regard to medicated vaginal devices or intracervical devices.
doi_str_mv 10.1016/0952-3278(93)90120-L
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_75800043</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>095232789390120L</els_id><sourcerecordid>75800043</sourcerecordid><originalsourceid>FETCH-LOGICAL-c301t-f376361ae94fbb40abdfcfaeca0df7f0342181f7e5a8863704241125438aadfc3</originalsourceid><addsrcrecordid>eNp9kd2KFDEQhYMo6-zqGyjkQkTB1vzNdPpGWHb9GRj0Qr0O6XTFLUl3ZpPMyj6I72vaaebSq4Q6XxWnThHyjLO3nPHNO9atRSNFq1918nXHuGDN7gFZ8bUUjdBCPiSrE_KYnOf8izEmOFdn5EzLjrdMr8if7QBTQY_OFowTjZ6W35EO6D2kqtBkCzQBRyw4_aQjuBs7YR4zdXEqKYYwl8sN0AQBbIZ5wpdvl9vrTH2KI80YbC7o6D6G-xFS_Q1whw7yG2qnoZZzxj4AxXEfFhf5CXnkbcjwdHkvyI-PH75ffW52Xz9try53jZOMl8bLdiM33EKnfN8rZvvBO2_BWTb41jOpBNfct7C2Wm9ky5RQnIu1ktraisoL8vI4d5_i7QFyMSNmByHYCeIhm3ata2ZKVlAdQZeq3wTe7BOONt0bzsx8DTNHbeaoTSfNv2uYXW17vsw_9CMMp6Yl_qq_WHSbnQ0-2clhPmGq1bpuULH3RwxqFncIyWSHMDkYMIErZoj4fx9_AST7qb8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>75800043</pqid></control><display><type>article</type><title>Identification of two different rate-limiting mechanisms controlling the release of NSAIDs from silastic polymeric devices, and possible implications</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Peplow, P.V.</creator><creatorcontrib>Peplow, P.V.</creatorcontrib><description>Two different rate-limiting mechanisms have been found by examining the release characteristics of meclofenamic acid, BW755C.hydrochloride, and diclofenac sodium from silastic polymeric rods into phosphate (0.1 M, pH 7.3) at 37°C. Experiments were performed using rods with initial drug concentrations of 3, 6 and 9% w/w and plots of Q-t and Q-t 1 2 were made (Q, cumulative amount of drug released into solution; t, time). For each of the three loadings of meclofenamic acid, the Q-t 1 2 plot was linear which indicated a matrix controlled release of the drug. With diclofenac sodium, each of the three loadings gave a Q-t plot that was linear thereby indicating a partition controlled release of this drug. For BW755C.HCl, the release of the drug from rods at the two lowest loadings was matrix controlled, but release from rods at the highest loading was partition controlled. The possible implications of these findings are discussed in regard to medicated vaginal devices or intracervical devices.</description><identifier>ISSN: 0952-3278</identifier><identifier>EISSN: 1532-2823</identifier><identifier>DOI: 10.1016/0952-3278(93)90120-L</identifier><identifier>PMID: 8391708</identifier><language>eng</language><publisher>Kidlington: Elsevier Ltd</publisher><subject>4,5-Dihydro-1-(3-(trifluoromethyl)phenyl)-1H-pyrazol-3-amine - administration &amp; dosage ; Biological and medical sciences ; Delayed-Action Preparations ; Diclofenac - administration &amp; dosage ; General pharmacology ; Meclofenamic Acid - administration &amp; dosage ; Medical sciences ; Pharmaceutical technology. Pharmaceutical industry ; Pharmacology. Drug treatments ; Silicone Elastomers ; Silicones</subject><ispartof>Prostaglandins, leukotrienes and essential fatty acids, 1993-05, Vol.48 (5), p.391-395</ispartof><rights>1993</rights><rights>1993 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c301t-f376361ae94fbb40abdfcfaeca0df7f0342181f7e5a8863704241125438aadfc3</citedby><cites>FETCH-LOGICAL-c301t-f376361ae94fbb40abdfcfaeca0df7f0342181f7e5a8863704241125438aadfc3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/0952-3278(93)90120-L$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,27922,27923,45993</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=4788218$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8391708$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Peplow, P.V.</creatorcontrib><title>Identification of two different rate-limiting mechanisms controlling the release of NSAIDs from silastic polymeric devices, and possible implications</title><title>Prostaglandins, leukotrienes and essential fatty acids</title><addtitle>Prostaglandins Leukot Essent Fatty Acids</addtitle><description>Two different rate-limiting mechanisms have been found by examining the release characteristics of meclofenamic acid, BW755C.hydrochloride, and diclofenac sodium from silastic polymeric rods into phosphate (0.1 M, pH 7.3) at 37°C. Experiments were performed using rods with initial drug concentrations of 3, 6 and 9% w/w and plots of Q-t and Q-t 1 2 were made (Q, cumulative amount of drug released into solution; t, time). For each of the three loadings of meclofenamic acid, the Q-t 1 2 plot was linear which indicated a matrix controlled release of the drug. With diclofenac sodium, each of the three loadings gave a Q-t plot that was linear thereby indicating a partition controlled release of this drug. For BW755C.HCl, the release of the drug from rods at the two lowest loadings was matrix controlled, but release from rods at the highest loading was partition controlled. The possible implications of these findings are discussed in regard to medicated vaginal devices or intracervical devices.</description><subject>4,5-Dihydro-1-(3-(trifluoromethyl)phenyl)-1H-pyrazol-3-amine - administration &amp; dosage</subject><subject>Biological and medical sciences</subject><subject>Delayed-Action Preparations</subject><subject>Diclofenac - administration &amp; dosage</subject><subject>General pharmacology</subject><subject>Meclofenamic Acid - administration &amp; dosage</subject><subject>Medical sciences</subject><subject>Pharmaceutical technology. Pharmaceutical industry</subject><subject>Pharmacology. Drug treatments</subject><subject>Silicone Elastomers</subject><subject>Silicones</subject><issn>0952-3278</issn><issn>1532-2823</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1993</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kd2KFDEQhYMo6-zqGyjkQkTB1vzNdPpGWHb9GRj0Qr0O6XTFLUl3ZpPMyj6I72vaaebSq4Q6XxWnThHyjLO3nPHNO9atRSNFq1918nXHuGDN7gFZ8bUUjdBCPiSrE_KYnOf8izEmOFdn5EzLjrdMr8if7QBTQY_OFowTjZ6W35EO6D2kqtBkCzQBRyw4_aQjuBs7YR4zdXEqKYYwl8sN0AQBbIZ5wpdvl9vrTH2KI80YbC7o6D6G-xFS_Q1whw7yG2qnoZZzxj4AxXEfFhf5CXnkbcjwdHkvyI-PH75ffW52Xz9try53jZOMl8bLdiM33EKnfN8rZvvBO2_BWTb41jOpBNfct7C2Wm9ky5RQnIu1ktraisoL8vI4d5_i7QFyMSNmByHYCeIhm3ata2ZKVlAdQZeq3wTe7BOONt0bzsx8DTNHbeaoTSfNv2uYXW17vsw_9CMMp6Yl_qq_WHSbnQ0-2clhPmGq1bpuULH3RwxqFncIyWSHMDkYMIErZoj4fx9_AST7qb8</recordid><startdate>199305</startdate><enddate>199305</enddate><creator>Peplow, P.V.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199305</creationdate><title>Identification of two different rate-limiting mechanisms controlling the release of NSAIDs from silastic polymeric devices, and possible implications</title><author>Peplow, P.V.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c301t-f376361ae94fbb40abdfcfaeca0df7f0342181f7e5a8863704241125438aadfc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1993</creationdate><topic>4,5-Dihydro-1-(3-(trifluoromethyl)phenyl)-1H-pyrazol-3-amine - administration &amp; dosage</topic><topic>Biological and medical sciences</topic><topic>Delayed-Action Preparations</topic><topic>Diclofenac - administration &amp; dosage</topic><topic>General pharmacology</topic><topic>Meclofenamic Acid - administration &amp; dosage</topic><topic>Medical sciences</topic><topic>Pharmaceutical technology. Pharmaceutical industry</topic><topic>Pharmacology. Drug treatments</topic><topic>Silicone Elastomers</topic><topic>Silicones</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Peplow, P.V.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Prostaglandins, leukotrienes and essential fatty acids</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Peplow, P.V.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Identification of two different rate-limiting mechanisms controlling the release of NSAIDs from silastic polymeric devices, and possible implications</atitle><jtitle>Prostaglandins, leukotrienes and essential fatty acids</jtitle><addtitle>Prostaglandins Leukot Essent Fatty Acids</addtitle><date>1993-05</date><risdate>1993</risdate><volume>48</volume><issue>5</issue><spage>391</spage><epage>395</epage><pages>391-395</pages><issn>0952-3278</issn><eissn>1532-2823</eissn><abstract>Two different rate-limiting mechanisms have been found by examining the release characteristics of meclofenamic acid, BW755C.hydrochloride, and diclofenac sodium from silastic polymeric rods into phosphate (0.1 M, pH 7.3) at 37°C. Experiments were performed using rods with initial drug concentrations of 3, 6 and 9% w/w and plots of Q-t and Q-t 1 2 were made (Q, cumulative amount of drug released into solution; t, time). For each of the three loadings of meclofenamic acid, the Q-t 1 2 plot was linear which indicated a matrix controlled release of the drug. With diclofenac sodium, each of the three loadings gave a Q-t plot that was linear thereby indicating a partition controlled release of this drug. For BW755C.HCl, the release of the drug from rods at the two lowest loadings was matrix controlled, but release from rods at the highest loading was partition controlled. The possible implications of these findings are discussed in regard to medicated vaginal devices or intracervical devices.</abstract><cop>Kidlington</cop><pub>Elsevier Ltd</pub><pmid>8391708</pmid><doi>10.1016/0952-3278(93)90120-L</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0952-3278
ispartof Prostaglandins, leukotrienes and essential fatty acids, 1993-05, Vol.48 (5), p.391-395
issn 0952-3278
1532-2823
language eng
recordid cdi_proquest_miscellaneous_75800043
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects 4,5-Dihydro-1-(3-(trifluoromethyl)phenyl)-1H-pyrazol-3-amine - administration & dosage
Biological and medical sciences
Delayed-Action Preparations
Diclofenac - administration & dosage
General pharmacology
Meclofenamic Acid - administration & dosage
Medical sciences
Pharmaceutical technology. Pharmaceutical industry
Pharmacology. Drug treatments
Silicone Elastomers
Silicones
title Identification of two different rate-limiting mechanisms controlling the release of NSAIDs from silastic polymeric devices, and possible implications
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T05%3A40%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Identification%20of%20two%20different%20rate-limiting%20mechanisms%20controlling%20the%20release%20of%20NSAIDs%20from%20silastic%20polymeric%20devices,%20and%20possible%20implications&rft.jtitle=Prostaglandins,%20leukotrienes%20and%20essential%20fatty%20acids&rft.au=Peplow,%20P.V.&rft.date=1993-05&rft.volume=48&rft.issue=5&rft.spage=391&rft.epage=395&rft.pages=391-395&rft.issn=0952-3278&rft.eissn=1532-2823&rft_id=info:doi/10.1016/0952-3278(93)90120-L&rft_dat=%3Cproquest_cross%3E75800043%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=75800043&rft_id=info:pmid/8391708&rft_els_id=095232789390120L&rfr_iscdi=true