Complication of benign tracheobronchial strictures by self-expanding metal stents

Self-expanding metal stents are used to palliate benign strictures. We examined the complications of this approach. Between 1997 and 2002, we observed recurrent airway obstruction and extension of benign inflammatory strictures after the placement of tracheobronchial Microvasive Ultraflex stents and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of thoracic and cardiovascular surgery 2003-09, Vol.126 (3), p.744-747
Hauptverfasser: Gaissert, Henning A, Grillo, Hermes C, Wright, Cameron D, Donahue, Dean M, Wain, John C, Mathisen, Douglas J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Self-expanding metal stents are used to palliate benign strictures. We examined the complications of this approach. Between 1997 and 2002, we observed recurrent airway obstruction and extension of benign inflammatory strictures after the placement of tracheobronchial Microvasive Ultraflex stents and Wallstents (Boston Scientific Corp, Natick, Mass), in 10 patients with postintubation strictures and 5 with other indications; all but 1 patient were referred to us. Patients with tracheal (9), subglottic (1), combined tracheal and subglottic (3), and bronchial (2) strictures had been treated with covered and uncovered Wallstents (6) and Microvasive Ultraflex stents (9). After stent insertion, stricture and granulations within previously normal airway were seen in all patients. New subglottic strictures resulting from the stent caused hoarseness in 4 patients. A bronchoesophageal fistula was found in 1 patient at presentation and a tracheoesophageal fistula in another during extraction of a Wallstent. Primary surgical reconstruction, judged to have been feasible before wire stent insertion in 10 patients, was possible after stenting in only 7 and failed in 2. Palliative tubes were placed in 60% (9/15). Self-expanding metal stents may lengthen luminal damage, incite subglottic strictures, and cause esophagorespiratory fistula in inflammatory airway strictures. The injury is severe, occurs after a short duration of stenting, and precludes definitive surgical treatment or requires more extensive tracheal resection. The current generation of self-expanding metal stents should be avoided in benign strictures of trachea and bronchi.
ISSN:0022-5223
1097-685X
DOI:10.1016/S0022-5223(03)00361-1