High flow coronary fistula closure by percutaneous coil packing
Few cases of transcatheter coronary fistula closure have been reported. High flow coronary fistulae are usually treated by surgery. This case report presents a 5.4 liters/min flow coronary fistula percutaneously closed by steel coils. This large flow needed the packing of 25 coils, 10‐15 cm long, fo...
Gespeichert in:
Veröffentlicht in: | Catheterization and cardiovascular diagnosis 1993-04, Vol.28 (4), p.342-346 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Few cases of transcatheter coronary fistula closure have been reported. High flow coronary fistulae are usually treated by surgery. This case report presents a 5.4 liters/min flow coronary fistula percutaneously closed by steel coils. This large flow needed the packing of 25 coils, 10‐15 cm long, for its total occlusion. © 1993 Wiley‐Liss, Inc. |
---|---|
ISSN: | 0098-6569 1097-0304 |
DOI: | 10.1002/ccd.1810280415 |