Miniaturized multiple Fourier-horn ultrasonic droplet generators for biomedical applications

Here we report micro-electro-mechanical system (MEMS)-based miniaturized silicon ultrasonic droplet generators of a new and simple nozzle architecture with multiple Fourier horns in resonance but without a central channel. The centimetre-sized nozzles operate at one to two MHz and a single vibration...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Lab on a chip 2010-01, Vol.10 (20), p.2733-2740
Hauptverfasser: Tsai, Chen S, Mao, Rong W, Lin, Shih K, Wang, Ning, Tsai, Shirley C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2740
container_issue 20
container_start_page 2733
container_title Lab on a chip
container_volume 10
creator Tsai, Chen S
Mao, Rong W
Lin, Shih K
Wang, Ning
Tsai, Shirley C
description Here we report micro-electro-mechanical system (MEMS)-based miniaturized silicon ultrasonic droplet generators of a new and simple nozzle architecture with multiple Fourier horns in resonance but without a central channel. The centimetre-sized nozzles operate at one to two MHz and a single vibration mode which readily facilitates temporal instability of Faraday waves to produce monodisperse droplets. Droplets with diameter range 2.2-4.6 μm are produced at high throughput of 420 μl min(-1) and very low electrical drive power of 80 mW. We also report the first theoretical prediction of the droplet diameter. The resulting MHz ultrasonic devices possess important advantages and demonstrate superior performance over earlier devices with a central channel and thus have high potential for biomedical applications such as efficient and effective delivery of inhaled medications and encapsulated therapy to the lung.
doi_str_mv 10.1039/c005262k
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_756298475</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>756298475</sourcerecordid><originalsourceid>FETCH-LOGICAL-c381t-3129045885939f3d7b774af2d5231620f4ffd3d58cae2be2094f137741da26b83</originalsourceid><addsrcrecordid>eNp9kL1OwzAYRS0EoqUg8QQoGywB__-MqKKABGKBDSlyYhsMSRzsZICnx4i2bEzf1f2O7nAAOEbwHEGiLhoIGeb4fQfMERWkhEiq3W1WYgYOUnqDEDHK5T6YYSgQZVDNwfO9770ep-i_rCm6qR390NpiFXJjY_kaYl_kMuoUet8UJob8HosX29uoxxBT4UIsah86a3yj20IPQ5vD6EOfDsGe022yR-u7AE-rq8flTXn3cH27vLwrGyLRWBKEFaRMSqaIcsSIWgiqHTYME8QxdNQ5QwyTjba4thgq6hDJDDIa81qSBTj93R1i-JhsGqvOp8a2re5tmFIlGMdKUsEyefYviTDngiGO-B_axJBStK4aou90_KwQrH6sVxvrGT1Zr0519rAFN5rJN-lPfTw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1266751616</pqid></control><display><type>article</type><title>Miniaturized multiple Fourier-horn ultrasonic droplet generators for biomedical applications</title><source>MEDLINE</source><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Tsai, Chen S ; Mao, Rong W ; Lin, Shih K ; Wang, Ning ; Tsai, Shirley C</creator><creatorcontrib>Tsai, Chen S ; Mao, Rong W ; Lin, Shih K ; Wang, Ning ; Tsai, Shirley C</creatorcontrib><description>Here we report micro-electro-mechanical system (MEMS)-based miniaturized silicon ultrasonic droplet generators of a new and simple nozzle architecture with multiple Fourier horns in resonance but without a central channel. The centimetre-sized nozzles operate at one to two MHz and a single vibration mode which readily facilitates temporal instability of Faraday waves to produce monodisperse droplets. Droplets with diameter range 2.2-4.6 μm are produced at high throughput of 420 μl min(-1) and very low electrical drive power of 80 mW. We also report the first theoretical prediction of the droplet diameter. The resulting MHz ultrasonic devices possess important advantages and demonstrate superior performance over earlier devices with a central channel and thus have high potential for biomedical applications such as efficient and effective delivery of inhaled medications and encapsulated therapy to the lung.</description><identifier>ISSN: 1473-0197</identifier><identifier>EISSN: 1473-0189</identifier><identifier>DOI: 10.1039/c005262k</identifier><identifier>PMID: 20714509</identifier><language>eng</language><publisher>England</publisher><subject>Biomedical Engineering - instrumentation ; Channels ; Devices ; Droplets ; Equipment Design ; Equipment Failure Analysis ; Generators ; Horns ; Instability ; Microfluidic Analytical Techniques - instrumentation ; Miniaturization ; Nebulizers and Vaporizers ; Nozzles ; Solutions - chemistry ; Ultrasonics - instrumentation ; Vibration mode</subject><ispartof>Lab on a chip, 2010-01, Vol.10 (20), p.2733-2740</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c381t-3129045885939f3d7b774af2d5231620f4ffd3d58cae2be2094f137741da26b83</citedby><cites>FETCH-LOGICAL-c381t-3129045885939f3d7b774af2d5231620f4ffd3d58cae2be2094f137741da26b83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20714509$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tsai, Chen S</creatorcontrib><creatorcontrib>Mao, Rong W</creatorcontrib><creatorcontrib>Lin, Shih K</creatorcontrib><creatorcontrib>Wang, Ning</creatorcontrib><creatorcontrib>Tsai, Shirley C</creatorcontrib><title>Miniaturized multiple Fourier-horn ultrasonic droplet generators for biomedical applications</title><title>Lab on a chip</title><addtitle>Lab Chip</addtitle><description>Here we report micro-electro-mechanical system (MEMS)-based miniaturized silicon ultrasonic droplet generators of a new and simple nozzle architecture with multiple Fourier horns in resonance but without a central channel. The centimetre-sized nozzles operate at one to two MHz and a single vibration mode which readily facilitates temporal instability of Faraday waves to produce monodisperse droplets. Droplets with diameter range 2.2-4.6 μm are produced at high throughput of 420 μl min(-1) and very low electrical drive power of 80 mW. We also report the first theoretical prediction of the droplet diameter. The resulting MHz ultrasonic devices possess important advantages and demonstrate superior performance over earlier devices with a central channel and thus have high potential for biomedical applications such as efficient and effective delivery of inhaled medications and encapsulated therapy to the lung.</description><subject>Biomedical Engineering - instrumentation</subject><subject>Channels</subject><subject>Devices</subject><subject>Droplets</subject><subject>Equipment Design</subject><subject>Equipment Failure Analysis</subject><subject>Generators</subject><subject>Horns</subject><subject>Instability</subject><subject>Microfluidic Analytical Techniques - instrumentation</subject><subject>Miniaturization</subject><subject>Nebulizers and Vaporizers</subject><subject>Nozzles</subject><subject>Solutions - chemistry</subject><subject>Ultrasonics - instrumentation</subject><subject>Vibration mode</subject><issn>1473-0197</issn><issn>1473-0189</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kL1OwzAYRS0EoqUg8QQoGywB__-MqKKABGKBDSlyYhsMSRzsZICnx4i2bEzf1f2O7nAAOEbwHEGiLhoIGeb4fQfMERWkhEiq3W1WYgYOUnqDEDHK5T6YYSgQZVDNwfO9770ep-i_rCm6qR390NpiFXJjY_kaYl_kMuoUet8UJob8HosX29uoxxBT4UIsah86a3yj20IPQ5vD6EOfDsGe022yR-u7AE-rq8flTXn3cH27vLwrGyLRWBKEFaRMSqaIcsSIWgiqHTYME8QxdNQ5QwyTjba4thgq6hDJDDIa81qSBTj93R1i-JhsGqvOp8a2re5tmFIlGMdKUsEyefYviTDngiGO-B_axJBStK4aou90_KwQrH6sVxvrGT1Zr0519rAFN5rJN-lPfTw</recordid><startdate>20100101</startdate><enddate>20100101</enddate><creator>Tsai, Chen S</creator><creator>Mao, Rong W</creator><creator>Lin, Shih K</creator><creator>Wang, Ning</creator><creator>Tsai, Shirley C</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>20100101</creationdate><title>Miniaturized multiple Fourier-horn ultrasonic droplet generators for biomedical applications</title><author>Tsai, Chen S ; Mao, Rong W ; Lin, Shih K ; Wang, Ning ; Tsai, Shirley C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c381t-3129045885939f3d7b774af2d5231620f4ffd3d58cae2be2094f137741da26b83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Biomedical Engineering - instrumentation</topic><topic>Channels</topic><topic>Devices</topic><topic>Droplets</topic><topic>Equipment Design</topic><topic>Equipment Failure Analysis</topic><topic>Generators</topic><topic>Horns</topic><topic>Instability</topic><topic>Microfluidic Analytical Techniques - instrumentation</topic><topic>Miniaturization</topic><topic>Nebulizers and Vaporizers</topic><topic>Nozzles</topic><topic>Solutions - chemistry</topic><topic>Ultrasonics - instrumentation</topic><topic>Vibration mode</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tsai, Chen S</creatorcontrib><creatorcontrib>Mao, Rong W</creatorcontrib><creatorcontrib>Lin, Shih K</creatorcontrib><creatorcontrib>Wang, Ning</creatorcontrib><creatorcontrib>Tsai, Shirley C</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Lab on a chip</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tsai, Chen S</au><au>Mao, Rong W</au><au>Lin, Shih K</au><au>Wang, Ning</au><au>Tsai, Shirley C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Miniaturized multiple Fourier-horn ultrasonic droplet generators for biomedical applications</atitle><jtitle>Lab on a chip</jtitle><addtitle>Lab Chip</addtitle><date>2010-01-01</date><risdate>2010</risdate><volume>10</volume><issue>20</issue><spage>2733</spage><epage>2740</epage><pages>2733-2740</pages><issn>1473-0197</issn><eissn>1473-0189</eissn><abstract>Here we report micro-electro-mechanical system (MEMS)-based miniaturized silicon ultrasonic droplet generators of a new and simple nozzle architecture with multiple Fourier horns in resonance but without a central channel. The centimetre-sized nozzles operate at one to two MHz and a single vibration mode which readily facilitates temporal instability of Faraday waves to produce monodisperse droplets. Droplets with diameter range 2.2-4.6 μm are produced at high throughput of 420 μl min(-1) and very low electrical drive power of 80 mW. We also report the first theoretical prediction of the droplet diameter. The resulting MHz ultrasonic devices possess important advantages and demonstrate superior performance over earlier devices with a central channel and thus have high potential for biomedical applications such as efficient and effective delivery of inhaled medications and encapsulated therapy to the lung.</abstract><cop>England</cop><pmid>20714509</pmid><doi>10.1039/c005262k</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1473-0197
ispartof Lab on a chip, 2010-01, Vol.10 (20), p.2733-2740
issn 1473-0197
1473-0189
language eng
recordid cdi_proquest_miscellaneous_756298475
source MEDLINE; Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection
subjects Biomedical Engineering - instrumentation
Channels
Devices
Droplets
Equipment Design
Equipment Failure Analysis
Generators
Horns
Instability
Microfluidic Analytical Techniques - instrumentation
Miniaturization
Nebulizers and Vaporizers
Nozzles
Solutions - chemistry
Ultrasonics - instrumentation
Vibration mode
title Miniaturized multiple Fourier-horn ultrasonic droplet generators for biomedical applications
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-14T16%3A38%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Miniaturized%20multiple%20Fourier-horn%20ultrasonic%20droplet%20generators%20for%20biomedical%20applications&rft.jtitle=Lab%20on%20a%20chip&rft.au=Tsai,%20Chen%20S&rft.date=2010-01-01&rft.volume=10&rft.issue=20&rft.spage=2733&rft.epage=2740&rft.pages=2733-2740&rft.issn=1473-0197&rft.eissn=1473-0189&rft_id=info:doi/10.1039/c005262k&rft_dat=%3Cproquest_cross%3E756298475%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1266751616&rft_id=info:pmid/20714509&rfr_iscdi=true