External Monitoring of Kidney Transplant Function Using Tc-99m(Sn)DTPA

The purpose of this study was to evaluate the use of an external counting technique to provide daily monitoring of kidney transplant function by measuring the renal clearance of Tc-99m(Sn)DTPA. During the first few weeks following transplant, 15 patients had their renal clearance of Tc-99m DTPA meas...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of nuclear medicine (1978) 1981-05, Vol.22 (5), p.411-416
Hauptverfasser: Sampson, William F. D, Macleod, Murdo A, Warren, David
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 416
container_issue 5
container_start_page 411
container_title The Journal of nuclear medicine (1978)
container_volume 22
creator Sampson, William F. D
Macleod, Murdo A
Warren, David
description The purpose of this study was to evaluate the use of an external counting technique to provide daily monitoring of kidney transplant function by measuring the renal clearance of Tc-99m(Sn)DTPA. During the first few weeks following transplant, 15 patients had their renal clearance of Tc-99m DTPA measured daily over periods of 5-24 hr. Clearance rates were compared with daily plasma creatinine levels, and the effects of diurnal variation, drug treatment, and physical activity noted. The results show that any significant fall in clearance rate of chelate, indicating a rejection episode, preceded a rise in plasma creatinine levels by at least 24 hr. One episode of transplant failure presented as a sudden deterioration in clearance rate of chelate; in the others the change was more gradual but was still apparent within hours. It is considered that this noninvasive, low-dose, easy-to-perform technique is of considerable value in extended daily monitoring of renal function and is superior to standard daily or twice-weekly renography for the early detection of transplant rejection.
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_75598070</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>75598070</sourcerecordid><originalsourceid>FETCH-LOGICAL-h237t-699f7248fe6c83e77c00448be9d7987ffcae48156f69f9ea88d512324b1d632a3</originalsourceid><addsrcrecordid>eNpFz81LwzAABfAgypzTP0HoSfRQyEfzdRxzVXGiYHcOWZpsGW06kxbdf--GA0_v8uPx3hkYI0poThnj52AMEUM5pZBegquUthBCJoQYgRGHCGOBxqCc__Q2Bt1kb13wfRd9WGedy159Hew-q6IOadfo0GflEEzvu5At09FUJpeyvf8MD4_Vx_QaXDjdJHtzyglYlvNq9pwv3p9eZtNFvsGE9zmT0nFcCGeZEcRybiAsCrGysuZScOeMtoVAlDkmnbRaiJoiTHCxQjUjWJMJuPvr3cXua7CpV61PxjaHhbYbkuKUSgE5PMDbExxWra3VLvpWx706Hf8v2vj15ttHq8JgGqvjEW9Di7GiqkCI_ALlL2EQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>75598070</pqid></control><display><type>article</type><title>External Monitoring of Kidney Transplant Function Using Tc-99m(Sn)DTPA</title><source>MEDLINE</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Sampson, William F. D ; Macleod, Murdo A ; Warren, David</creator><creatorcontrib>Sampson, William F. D ; Macleod, Murdo A ; Warren, David</creatorcontrib><description>The purpose of this study was to evaluate the use of an external counting technique to provide daily monitoring of kidney transplant function by measuring the renal clearance of Tc-99m(Sn)DTPA. During the first few weeks following transplant, 15 patients had their renal clearance of Tc-99m DTPA measured daily over periods of 5-24 hr. Clearance rates were compared with daily plasma creatinine levels, and the effects of diurnal variation, drug treatment, and physical activity noted. The results show that any significant fall in clearance rate of chelate, indicating a rejection episode, preceded a rise in plasma creatinine levels by at least 24 hr. One episode of transplant failure presented as a sudden deterioration in clearance rate of chelate; in the others the change was more gradual but was still apparent within hours. It is considered that this noninvasive, low-dose, easy-to-perform technique is of considerable value in extended daily monitoring of renal function and is superior to standard daily or twice-weekly renography for the early detection of transplant rejection.</description><identifier>ISSN: 0161-5505</identifier><identifier>EISSN: 1535-5667</identifier><identifier>PMID: 7012281</identifier><language>eng</language><publisher>United States: Soc Nuclear Med</publisher><subject>Creatinine - blood ; Glomerular Filtration Rate ; Graft Rejection ; Humans ; Kidney - diagnostic imaging ; Kidney - physiology ; Kidney Transplantation ; Pentetic Acid ; Radionuclide Imaging ; Technetium ; Technetium Tc 99m Pentetate ; Time Factors ; Transplantation, Homologous</subject><ispartof>The Journal of nuclear medicine (1978), 1981-05, Vol.22 (5), p.411-416</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7012281$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sampson, William F. D</creatorcontrib><creatorcontrib>Macleod, Murdo A</creatorcontrib><creatorcontrib>Warren, David</creatorcontrib><title>External Monitoring of Kidney Transplant Function Using Tc-99m(Sn)DTPA</title><title>The Journal of nuclear medicine (1978)</title><addtitle>J Nucl Med</addtitle><description>The purpose of this study was to evaluate the use of an external counting technique to provide daily monitoring of kidney transplant function by measuring the renal clearance of Tc-99m(Sn)DTPA. During the first few weeks following transplant, 15 patients had their renal clearance of Tc-99m DTPA measured daily over periods of 5-24 hr. Clearance rates were compared with daily plasma creatinine levels, and the effects of diurnal variation, drug treatment, and physical activity noted. The results show that any significant fall in clearance rate of chelate, indicating a rejection episode, preceded a rise in plasma creatinine levels by at least 24 hr. One episode of transplant failure presented as a sudden deterioration in clearance rate of chelate; in the others the change was more gradual but was still apparent within hours. It is considered that this noninvasive, low-dose, easy-to-perform technique is of considerable value in extended daily monitoring of renal function and is superior to standard daily or twice-weekly renography for the early detection of transplant rejection.</description><subject>Creatinine - blood</subject><subject>Glomerular Filtration Rate</subject><subject>Graft Rejection</subject><subject>Humans</subject><subject>Kidney - diagnostic imaging</subject><subject>Kidney - physiology</subject><subject>Kidney Transplantation</subject><subject>Pentetic Acid</subject><subject>Radionuclide Imaging</subject><subject>Technetium</subject><subject>Technetium Tc 99m Pentetate</subject><subject>Time Factors</subject><subject>Transplantation, Homologous</subject><issn>0161-5505</issn><issn>1535-5667</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1981</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFz81LwzAABfAgypzTP0HoSfRQyEfzdRxzVXGiYHcOWZpsGW06kxbdf--GA0_v8uPx3hkYI0poThnj52AMEUM5pZBegquUthBCJoQYgRGHCGOBxqCc__Q2Bt1kb13wfRd9WGedy159Hew-q6IOadfo0GflEEzvu5At09FUJpeyvf8MD4_Vx_QaXDjdJHtzyglYlvNq9pwv3p9eZtNFvsGE9zmT0nFcCGeZEcRybiAsCrGysuZScOeMtoVAlDkmnbRaiJoiTHCxQjUjWJMJuPvr3cXua7CpV61PxjaHhbYbkuKUSgE5PMDbExxWra3VLvpWx706Hf8v2vj15ttHq8JgGqvjEW9Di7GiqkCI_ALlL2EQ</recordid><startdate>198105</startdate><enddate>198105</enddate><creator>Sampson, William F. D</creator><creator>Macleod, Murdo A</creator><creator>Warren, David</creator><general>Soc Nuclear Med</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>198105</creationdate><title>External Monitoring of Kidney Transplant Function Using Tc-99m(Sn)DTPA</title><author>Sampson, William F. D ; Macleod, Murdo A ; Warren, David</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-h237t-699f7248fe6c83e77c00448be9d7987ffcae48156f69f9ea88d512324b1d632a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1981</creationdate><topic>Creatinine - blood</topic><topic>Glomerular Filtration Rate</topic><topic>Graft Rejection</topic><topic>Humans</topic><topic>Kidney - diagnostic imaging</topic><topic>Kidney - physiology</topic><topic>Kidney Transplantation</topic><topic>Pentetic Acid</topic><topic>Radionuclide Imaging</topic><topic>Technetium</topic><topic>Technetium Tc 99m Pentetate</topic><topic>Time Factors</topic><topic>Transplantation, Homologous</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sampson, William F. D</creatorcontrib><creatorcontrib>Macleod, Murdo A</creatorcontrib><creatorcontrib>Warren, David</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of nuclear medicine (1978)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sampson, William F. D</au><au>Macleod, Murdo A</au><au>Warren, David</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>External Monitoring of Kidney Transplant Function Using Tc-99m(Sn)DTPA</atitle><jtitle>The Journal of nuclear medicine (1978)</jtitle><addtitle>J Nucl Med</addtitle><date>1981-05</date><risdate>1981</risdate><volume>22</volume><issue>5</issue><spage>411</spage><epage>416</epage><pages>411-416</pages><issn>0161-5505</issn><eissn>1535-5667</eissn><abstract>The purpose of this study was to evaluate the use of an external counting technique to provide daily monitoring of kidney transplant function by measuring the renal clearance of Tc-99m(Sn)DTPA. During the first few weeks following transplant, 15 patients had their renal clearance of Tc-99m DTPA measured daily over periods of 5-24 hr. Clearance rates were compared with daily plasma creatinine levels, and the effects of diurnal variation, drug treatment, and physical activity noted. The results show that any significant fall in clearance rate of chelate, indicating a rejection episode, preceded a rise in plasma creatinine levels by at least 24 hr. One episode of transplant failure presented as a sudden deterioration in clearance rate of chelate; in the others the change was more gradual but was still apparent within hours. It is considered that this noninvasive, low-dose, easy-to-perform technique is of considerable value in extended daily monitoring of renal function and is superior to standard daily or twice-weekly renography for the early detection of transplant rejection.</abstract><cop>United States</cop><pub>Soc Nuclear Med</pub><pmid>7012281</pmid><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0161-5505
ispartof The Journal of nuclear medicine (1978), 1981-05, Vol.22 (5), p.411-416
issn 0161-5505
1535-5667
language eng
recordid cdi_proquest_miscellaneous_75598070
source MEDLINE; EZB-FREE-00999 freely available EZB journals
subjects Creatinine - blood
Glomerular Filtration Rate
Graft Rejection
Humans
Kidney - diagnostic imaging
Kidney - physiology
Kidney Transplantation
Pentetic Acid
Radionuclide Imaging
Technetium
Technetium Tc 99m Pentetate
Time Factors
Transplantation, Homologous
title External Monitoring of Kidney Transplant Function Using Tc-99m(Sn)DTPA
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T11%3A37%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=External%20Monitoring%20of%20Kidney%20Transplant%20Function%20Using%20Tc-99m(Sn)DTPA&rft.jtitle=The%20Journal%20of%20nuclear%20medicine%20(1978)&rft.au=Sampson,%20William%20F.%20D&rft.date=1981-05&rft.volume=22&rft.issue=5&rft.spage=411&rft.epage=416&rft.pages=411-416&rft.issn=0161-5505&rft.eissn=1535-5667&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E75598070%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=75598070&rft_id=info:pmid/7012281&rfr_iscdi=true