A preliminary study of wear of porcelain when subjected to functional movements of retentive clasp arms
Porcelain-metal crowns simulating abutment retainers for removable partial denture clasping were studied to determine the effects of wear to the porcelain surface and possibilities of fracture. Surface profile recordings at x 1,000 were made on the porcelain surfaces before and after subjecting samp...
Gespeichert in:
Veröffentlicht in: | The Journal of prosthetic dentistry 1981, Vol.45 (1), p.14-17 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 17 |
---|---|
container_issue | 1 |
container_start_page | 14 |
container_title | The Journal of prosthetic dentistry |
container_volume | 45 |
creator | Maroso, D.J. Schmidt, J.R. Blustein, R. |
description | Porcelain-metal crowns simulating abutment retainers for removable partial denture clasping were studied to determine the effects of wear to the porcelain surface and possibilities of fracture. Surface profile recordings at x 1,000 were made on the porcelain surfaces before and after subjecting samples to wear that was equivalent to 2 years of patient use. Little or no change was recorded in these surface profiles, indicating that little or no wear had occurred. None of the samples failed due to porcelain fracture. It appears that well-fabricated, glazed porcelain surfaces can withstand the wear forces of removable partial retentive clasp arms. |
doi_str_mv | 10.1016/0022-3913(81)90005-6 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_75554128</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0022391381900056</els_id><sourcerecordid>75554128</sourcerecordid><originalsourceid>FETCH-LOGICAL-c357t-5fffb930082560b02b4502b3f6840fa9acfa5681ade7180aefdf2a2fe68127873</originalsourceid><addsrcrecordid>eNp9kF9PwyAUxYnRzDn9BprwZPShCnSU9sVkWfyXLPFFnwmlF2VpS4V2y7691C0--sIl3HPu5fwQuqTkjhKa3RPCWJIWNL3J6W1BCOFJdoSmlBQiyfI5PUbTP8kpOgthHTU5F3SCJoIQkTE6RZ8L3HmobWNb5Xc49EO1w87gLSg_1s55DbWyLd5-QYvDUK5B91Dh3mEztLq3rlU1btwGGmj7MHo89PFqN4B1rUKHlW_COToxqg5wcagz9PH0-L58SVZvz6_LxSrRKRd9wo0xZZHGfzKekZKwcs7jkZoYiBhVKG0Uz3KqKhA0JwpMZZhiBuIbE7lIZ-h6P7fz7nuA0MvGhpigVi24IUjBOZ9TlkfhfC_U3oXgwcjO2yYykJTIka8c4ckRnsyp_OUrs2i7OswfygaqP9MBaOw_7PsQQ24seBm0hVZDZX0EJytn_1_wA-2HiwQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>75554128</pqid></control><display><type>article</type><title>A preliminary study of wear of porcelain when subjected to functional movements of retentive clasp arms</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Maroso, D.J. ; Schmidt, J.R. ; Blustein, R.</creator><creatorcontrib>Maroso, D.J. ; Schmidt, J.R. ; Blustein, R.</creatorcontrib><description>Porcelain-metal crowns simulating abutment retainers for removable partial denture clasping were studied to determine the effects of wear to the porcelain surface and possibilities of fracture. Surface profile recordings at x 1,000 were made on the porcelain surfaces before and after subjecting samples to wear that was equivalent to 2 years of patient use. Little or no change was recorded in these surface profiles, indicating that little or no wear had occurred. None of the samples failed due to porcelain fracture. It appears that well-fabricated, glazed porcelain surfaces can withstand the wear forces of removable partial retentive clasp arms.</description><identifier>ISSN: 0022-3913</identifier><identifier>EISSN: 1097-6841</identifier><identifier>DOI: 10.1016/0022-3913(81)90005-6</identifier><identifier>PMID: 7007621</identifier><language>eng</language><publisher>United States: Mosby, Inc</publisher><subject>Dental Abutments ; Dental Porcelain ; Dental Stress Analysis - instrumentation ; Dentistry ; Denture Design ; Denture Retention ; Denture, Partial, Removable ; Surface Properties</subject><ispartof>The Journal of prosthetic dentistry, 1981, Vol.45 (1), p.14-17</ispartof><rights>1981 The C. V. Mosby Co.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c357t-5fffb930082560b02b4502b3f6840fa9acfa5681ade7180aefdf2a2fe68127873</citedby><cites>FETCH-LOGICAL-c357t-5fffb930082560b02b4502b3f6840fa9acfa5681ade7180aefdf2a2fe68127873</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/0022-3913(81)90005-6$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,4024,27923,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7007621$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Maroso, D.J.</creatorcontrib><creatorcontrib>Schmidt, J.R.</creatorcontrib><creatorcontrib>Blustein, R.</creatorcontrib><title>A preliminary study of wear of porcelain when subjected to functional movements of retentive clasp arms</title><title>The Journal of prosthetic dentistry</title><addtitle>J Prosthet Dent</addtitle><description>Porcelain-metal crowns simulating abutment retainers for removable partial denture clasping were studied to determine the effects of wear to the porcelain surface and possibilities of fracture. Surface profile recordings at x 1,000 were made on the porcelain surfaces before and after subjecting samples to wear that was equivalent to 2 years of patient use. Little or no change was recorded in these surface profiles, indicating that little or no wear had occurred. None of the samples failed due to porcelain fracture. It appears that well-fabricated, glazed porcelain surfaces can withstand the wear forces of removable partial retentive clasp arms.</description><subject>Dental Abutments</subject><subject>Dental Porcelain</subject><subject>Dental Stress Analysis - instrumentation</subject><subject>Dentistry</subject><subject>Denture Design</subject><subject>Denture Retention</subject><subject>Denture, Partial, Removable</subject><subject>Surface Properties</subject><issn>0022-3913</issn><issn>1097-6841</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1981</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kF9PwyAUxYnRzDn9BprwZPShCnSU9sVkWfyXLPFFnwmlF2VpS4V2y7691C0--sIl3HPu5fwQuqTkjhKa3RPCWJIWNL3J6W1BCOFJdoSmlBQiyfI5PUbTP8kpOgthHTU5F3SCJoIQkTE6RZ8L3HmobWNb5Xc49EO1w87gLSg_1s55DbWyLd5-QYvDUK5B91Dh3mEztLq3rlU1btwGGmj7MHo89PFqN4B1rUKHlW_COToxqg5wcagz9PH0-L58SVZvz6_LxSrRKRd9wo0xZZHGfzKekZKwcs7jkZoYiBhVKG0Uz3KqKhA0JwpMZZhiBuIbE7lIZ-h6P7fz7nuA0MvGhpigVi24IUjBOZ9TlkfhfC_U3oXgwcjO2yYykJTIka8c4ckRnsyp_OUrs2i7OswfygaqP9MBaOw_7PsQQ24seBm0hVZDZX0EJytn_1_wA-2HiwQ</recordid><startdate>1981</startdate><enddate>1981</enddate><creator>Maroso, D.J.</creator><creator>Schmidt, J.R.</creator><creator>Blustein, R.</creator><general>Mosby, Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>1981</creationdate><title>A preliminary study of wear of porcelain when subjected to functional movements of retentive clasp arms</title><author>Maroso, D.J. ; Schmidt, J.R. ; Blustein, R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c357t-5fffb930082560b02b4502b3f6840fa9acfa5681ade7180aefdf2a2fe68127873</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1981</creationdate><topic>Dental Abutments</topic><topic>Dental Porcelain</topic><topic>Dental Stress Analysis - instrumentation</topic><topic>Dentistry</topic><topic>Denture Design</topic><topic>Denture Retention</topic><topic>Denture, Partial, Removable</topic><topic>Surface Properties</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Maroso, D.J.</creatorcontrib><creatorcontrib>Schmidt, J.R.</creatorcontrib><creatorcontrib>Blustein, R.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of prosthetic dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Maroso, D.J.</au><au>Schmidt, J.R.</au><au>Blustein, R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A preliminary study of wear of porcelain when subjected to functional movements of retentive clasp arms</atitle><jtitle>The Journal of prosthetic dentistry</jtitle><addtitle>J Prosthet Dent</addtitle><date>1981</date><risdate>1981</risdate><volume>45</volume><issue>1</issue><spage>14</spage><epage>17</epage><pages>14-17</pages><issn>0022-3913</issn><eissn>1097-6841</eissn><abstract>Porcelain-metal crowns simulating abutment retainers for removable partial denture clasping were studied to determine the effects of wear to the porcelain surface and possibilities of fracture. Surface profile recordings at x 1,000 were made on the porcelain surfaces before and after subjecting samples to wear that was equivalent to 2 years of patient use. Little or no change was recorded in these surface profiles, indicating that little or no wear had occurred. None of the samples failed due to porcelain fracture. It appears that well-fabricated, glazed porcelain surfaces can withstand the wear forces of removable partial retentive clasp arms.</abstract><cop>United States</cop><pub>Mosby, Inc</pub><pmid>7007621</pmid><doi>10.1016/0022-3913(81)90005-6</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0022-3913 |
ispartof | The Journal of prosthetic dentistry, 1981, Vol.45 (1), p.14-17 |
issn | 0022-3913 1097-6841 |
language | eng |
recordid | cdi_proquest_miscellaneous_75554128 |
source | MEDLINE; ScienceDirect Journals (5 years ago - present) |
subjects | Dental Abutments Dental Porcelain Dental Stress Analysis - instrumentation Dentistry Denture Design Denture Retention Denture, Partial, Removable Surface Properties |
title | A preliminary study of wear of porcelain when subjected to functional movements of retentive clasp arms |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T05%3A04%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20preliminary%20study%20of%20wear%20of%20porcelain%20when%20subjected%20to%20functional%20movements%20of%20retentive%20clasp%20arms&rft.jtitle=The%20Journal%20of%20prosthetic%20dentistry&rft.au=Maroso,%20D.J.&rft.date=1981&rft.volume=45&rft.issue=1&rft.spage=14&rft.epage=17&rft.pages=14-17&rft.issn=0022-3913&rft.eissn=1097-6841&rft_id=info:doi/10.1016/0022-3913(81)90005-6&rft_dat=%3Cproquest_cross%3E75554128%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=75554128&rft_id=info:pmid/7007621&rft_els_id=0022391381900056&rfr_iscdi=true |