Absorption measurements of water-vapor concentration, temperature, and line-shape parameters using a tunable InGaAsP diode laser

A tunable diode laser diagnostic based on spectrally resolved laser absorption has been developed to detect water vapor. The system uses a distributed feedback InGaAsP diode laser, emitting at ~ 1.38 µm. The diode laser is tuned in wavelength by modulation of the current, resulting in 1-cm(-1) tunin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Optics 1993-10, Vol.32 (30), p.6104-6116
Hauptverfasser: ARROYO, M. P, HANSON, R. K
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 6116
container_issue 30
container_start_page 6104
container_title Applied Optics
container_volume 32
creator ARROYO, M. P
HANSON, R. K
description A tunable diode laser diagnostic based on spectrally resolved laser absorption has been developed to detect water vapor. The system uses a distributed feedback InGaAsP diode laser, emitting at ~ 1.38 µm. The diode laser is tuned in wavelength by modulation of the current, resulting in 1-cm(-1) tuning at 80-Hz repetition rate. The directly measured absorption spectra yield values for water-vapor concentration and temperature, as well as a collision-broadening line shape. To our knowledge, we accurately determined required data for H(2)O line strengths and self-broadening coefficients for several spectral lines in a static cell filled with pure water vapor. The temperature and concentration of the water vapor present in laboratory room air and in the postflame gases above a methane-air flat flame burner have also been measured. These results agree well with calculated values and independent measurements.
doi_str_mv 10.1364/ao.32.006104
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_755161363</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>755161363</sourcerecordid><originalsourceid>FETCH-LOGICAL-c383t-2b3c54fd2b0fa95f31f36df4105965104d14f9c83feed70210685201500e61383</originalsourceid><addsrcrecordid>eNo90EFv1DAQBWCrArVL4cYZ-YDUy2YZ27E3Oa4qKJUqlQOco0kyhqDEDp6kiBs_va5229PIo89PmifEewU7ZVz5CePO6B2AU1CeiY2ypi5Kq_UrsQEAU7ja2Avxhvk3gNKVq8_FhYbKutJUG_H_0HJM8zLEICdCXhNNFBaW0cu_uFAqHnCOSXYxdHmf8Elu5ULTTPmR-VZi6OU4BCr4F84kZ0w4Uf7KcuUh_JQolzVgO5K8DTd44G-yH2JPckSm9Fa89jgyvTvNS_Hjy-fv11-Lu_ub2-vDXdGZyiyFbk1nS9_rFjzW1hvljet9qcDWzubTe1X6uquMJ-r3oBW4ympQFoCcyhGX4uqYO6f4ZyVemmngjsYRA8WVm721KkNnstweZZcicyLfzGmYMP1rFDRPlTeH-8bo5lh55h9OwWs7Uf-CnzvO4OMJIHc4-oShG_jF5ROg3BvzCB3QiYo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>755161363</pqid></control><display><type>article</type><title>Absorption measurements of water-vapor concentration, temperature, and line-shape parameters using a tunable InGaAsP diode laser</title><source>Alma/SFX Local Collection</source><source>Optica Publishing Group Journals</source><creator>ARROYO, M. P ; HANSON, R. K</creator><creatorcontrib>ARROYO, M. P ; HANSON, R. K</creatorcontrib><description>A tunable diode laser diagnostic based on spectrally resolved laser absorption has been developed to detect water vapor. The system uses a distributed feedback InGaAsP diode laser, emitting at ~ 1.38 µm. The diode laser is tuned in wavelength by modulation of the current, resulting in 1-cm(-1) tuning at 80-Hz repetition rate. The directly measured absorption spectra yield values for water-vapor concentration and temperature, as well as a collision-broadening line shape. To our knowledge, we accurately determined required data for H(2)O line strengths and self-broadening coefficients for several spectral lines in a static cell filled with pure water vapor. The temperature and concentration of the water vapor present in laboratory room air and in the postflame gases above a methane-air flat flame burner have also been measured. These results agree well with calculated values and independent measurements.</description><identifier>ISSN: 0003-6935</identifier><identifier>ISSN: 1559-128X</identifier><identifier>EISSN: 1539-4522</identifier><identifier>DOI: 10.1364/ao.32.006104</identifier><identifier>PMID: 20856438</identifier><identifier>CODEN: APOPAI</identifier><language>eng</language><publisher>Washington, DC: Optical Society of America</publisher><subject>Applied sciences ; Combustion. Flame ; Energy ; Energy. Thermal use of fuels ; Exact sciences and technology ; Miscellaneous ; Theoretical studies. Data and constants. Metering</subject><ispartof>Applied Optics, 1993-10, Vol.32 (30), p.6104-6116</ispartof><rights>1994 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c383t-2b3c54fd2b0fa95f31f36df4105965104d14f9c83feed70210685201500e61383</citedby><cites>FETCH-LOGICAL-c383t-2b3c54fd2b0fa95f31f36df4105965104d14f9c83feed70210685201500e61383</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=4100473$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20856438$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>ARROYO, M. P</creatorcontrib><creatorcontrib>HANSON, R. K</creatorcontrib><title>Absorption measurements of water-vapor concentration, temperature, and line-shape parameters using a tunable InGaAsP diode laser</title><title>Applied Optics</title><addtitle>Appl Opt</addtitle><description>A tunable diode laser diagnostic based on spectrally resolved laser absorption has been developed to detect water vapor. The system uses a distributed feedback InGaAsP diode laser, emitting at ~ 1.38 µm. The diode laser is tuned in wavelength by modulation of the current, resulting in 1-cm(-1) tuning at 80-Hz repetition rate. The directly measured absorption spectra yield values for water-vapor concentration and temperature, as well as a collision-broadening line shape. To our knowledge, we accurately determined required data for H(2)O line strengths and self-broadening coefficients for several spectral lines in a static cell filled with pure water vapor. The temperature and concentration of the water vapor present in laboratory room air and in the postflame gases above a methane-air flat flame burner have also been measured. These results agree well with calculated values and independent measurements.</description><subject>Applied sciences</subject><subject>Combustion. Flame</subject><subject>Energy</subject><subject>Energy. Thermal use of fuels</subject><subject>Exact sciences and technology</subject><subject>Miscellaneous</subject><subject>Theoretical studies. Data and constants. Metering</subject><issn>0003-6935</issn><issn>1559-128X</issn><issn>1539-4522</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1993</creationdate><recordtype>article</recordtype><recordid>eNo90EFv1DAQBWCrArVL4cYZ-YDUy2YZ27E3Oa4qKJUqlQOco0kyhqDEDp6kiBs_va5229PIo89PmifEewU7ZVz5CePO6B2AU1CeiY2ypi5Kq_UrsQEAU7ja2Avxhvk3gNKVq8_FhYbKutJUG_H_0HJM8zLEICdCXhNNFBaW0cu_uFAqHnCOSXYxdHmf8Elu5ULTTPmR-VZi6OU4BCr4F84kZ0w4Uf7KcuUh_JQolzVgO5K8DTd44G-yH2JPckSm9Fa89jgyvTvNS_Hjy-fv11-Lu_ub2-vDXdGZyiyFbk1nS9_rFjzW1hvljet9qcDWzubTe1X6uquMJ-r3oBW4ympQFoCcyhGX4uqYO6f4ZyVemmngjsYRA8WVm721KkNnstweZZcicyLfzGmYMP1rFDRPlTeH-8bo5lh55h9OwWs7Uf-CnzvO4OMJIHc4-oShG_jF5ROg3BvzCB3QiYo</recordid><startdate>19931020</startdate><enddate>19931020</enddate><creator>ARROYO, M. P</creator><creator>HANSON, R. K</creator><general>Optical Society of America</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19931020</creationdate><title>Absorption measurements of water-vapor concentration, temperature, and line-shape parameters using a tunable InGaAsP diode laser</title><author>ARROYO, M. P ; HANSON, R. K</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c383t-2b3c54fd2b0fa95f31f36df4105965104d14f9c83feed70210685201500e61383</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Applied sciences</topic><topic>Combustion. Flame</topic><topic>Energy</topic><topic>Energy. Thermal use of fuels</topic><topic>Exact sciences and technology</topic><topic>Miscellaneous</topic><topic>Theoretical studies. Data and constants. Metering</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>ARROYO, M. P</creatorcontrib><creatorcontrib>HANSON, R. K</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied Optics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>ARROYO, M. P</au><au>HANSON, R. K</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Absorption measurements of water-vapor concentration, temperature, and line-shape parameters using a tunable InGaAsP diode laser</atitle><jtitle>Applied Optics</jtitle><addtitle>Appl Opt</addtitle><date>1993-10-20</date><risdate>1993</risdate><volume>32</volume><issue>30</issue><spage>6104</spage><epage>6116</epage><pages>6104-6116</pages><issn>0003-6935</issn><issn>1559-128X</issn><eissn>1539-4522</eissn><coden>APOPAI</coden><abstract>A tunable diode laser diagnostic based on spectrally resolved laser absorption has been developed to detect water vapor. The system uses a distributed feedback InGaAsP diode laser, emitting at ~ 1.38 µm. The diode laser is tuned in wavelength by modulation of the current, resulting in 1-cm(-1) tuning at 80-Hz repetition rate. The directly measured absorption spectra yield values for water-vapor concentration and temperature, as well as a collision-broadening line shape. To our knowledge, we accurately determined required data for H(2)O line strengths and self-broadening coefficients for several spectral lines in a static cell filled with pure water vapor. The temperature and concentration of the water vapor present in laboratory room air and in the postflame gases above a methane-air flat flame burner have also been measured. These results agree well with calculated values and independent measurements.</abstract><cop>Washington, DC</cop><pub>Optical Society of America</pub><pmid>20856438</pmid><doi>10.1364/ao.32.006104</doi><tpages>13</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-6935
ispartof Applied Optics, 1993-10, Vol.32 (30), p.6104-6116
issn 0003-6935
1559-128X
1539-4522
language eng
recordid cdi_proquest_miscellaneous_755161363
source Alma/SFX Local Collection; Optica Publishing Group Journals
subjects Applied sciences
Combustion. Flame
Energy
Energy. Thermal use of fuels
Exact sciences and technology
Miscellaneous
Theoretical studies. Data and constants. Metering
title Absorption measurements of water-vapor concentration, temperature, and line-shape parameters using a tunable InGaAsP diode laser
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T16%3A12%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Absorption%20measurements%20of%20water-vapor%20concentration,%20temperature,%20and%20line-shape%20parameters%20using%20a%20tunable%20InGaAsP%20diode%20laser&rft.jtitle=Applied%20Optics&rft.au=ARROYO,%20M.%20P&rft.date=1993-10-20&rft.volume=32&rft.issue=30&rft.spage=6104&rft.epage=6116&rft.pages=6104-6116&rft.issn=0003-6935&rft.eissn=1539-4522&rft.coden=APOPAI&rft_id=info:doi/10.1364/ao.32.006104&rft_dat=%3Cproquest_cross%3E755161363%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=755161363&rft_id=info:pmid/20856438&rfr_iscdi=true