Simultaneous quantitative determination of N(G),N(G)-dimethyl-L-arginine or asymmetric dimethylarginine and related pathway's metabolites in biological fluids by ultrahigh-performance liquid chromatography/electrospray ionization-tandem mass spectrometry
Asymmetric dimethylarginine (ADMA), an endogenous nitric oxide (NO) formation inhibitor, has emerged as a promising biomarker of NO-associated endothelial dysfunction in cardiovascular diseases as well in chronic renal failure. The interest in potentially fundamental role of this metabolite, in basi...
Gespeichert in:
Veröffentlicht in: | Analytica chimica acta 2010-09, Vol.677 (2), p.140-148 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Asymmetric dimethylarginine (ADMA), an endogenous nitric oxide (NO) formation inhibitor, has emerged as a promising biomarker of NO-associated endothelial dysfunction in cardiovascular diseases as well in chronic renal failure. The interest in potentially fundamental role of this metabolite, in basic and clinical research, led to the development of numerous analytical methods for the quantitative determination of ADMA and dimethylarginines in biological systems, notably plasma, serum and urine.
The aim of this work was to present a simple, fast and accurate UPLC-tandem-MS-based method for the simultaneous determination and quantification of arginine, ADMA, SDMA, NMMA, homo-arginine and citrulline. This method is designed for high sample throughput of only 10 μL of human plasma, serum or urine.
The analysis time is reduced to 1.9 min by an ultrahigh-performance liquid chromatography run coupled with electrospray ionization (ESI) in the positive mode tandem mass spectrometry detection.
The method was validated in plasma, serum and urine. Correlation coefficients (r(2)) of the calibration curves in all matrices considered ranged from 0.9810 to 0.9993. Inter- and intra-assay precision, accuracy, recovery and carry-over were evaluated for validation. The LOD was 0.01 μM for all compounds in water, plasma and serum and 0.1 μM in urine. The LOQ was 0.05 μM for ADMA, SDMA, NMMA and H-Arg and 0.5 μM for Arg and Cit in water, plasma and serum; while in urine was 0.1 μM for ADMA, SDMA, NMMA and H-Arg and 0.5 μM for Arg and Cit. The precision was ranged from 1% to 15% expressed as CV% and the accuracy (bias %) was |
---|---|
ISSN: | 1873-4324 |
DOI: | 10.1016/j.aca.2010.08.011 |