A blinded, randomized, multicenter study of an intravenous Staphylococcus aureus immune globulin
Very low birth weight (VLBW) infants are vulnerable to nosocomial infections and subsequent morbidity; including infections caused by Staphylococcus aureus: 85% of nosocomial S. aureus infections are caused by capsular polysaccharide (CPS) types 5 and 8. Altastaph is a polyclonal investigational hum...
Gespeichert in:
Veröffentlicht in: | Journal of perinatology 2006-05, Vol.26 (5), p.290-295 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Very low birth weight (VLBW) infants are vulnerable to nosocomial infections and subsequent morbidity; including infections caused by Staphylococcus aureus: 85% of nosocomial S. aureus infections are caused by capsular polysaccharide (CPS) types 5 and 8. Altastaph is a polyclonal investigational human immunoglobulin G (IgG) with high levels of opsonizing S. aureus CPS types 5 and 8 IgG.
A Phase 2 clinical trial to assess the safety and kinetics of Altastaph in VLBW infants. Neonates in this multicenter study were randomized to receive two identical 20 ml/kg i.v. infusions of either 0.45% NaCl placebo or 1000 mg Altastaph/kg. Each infant was followed for 28 days after the second infusion or until discharge. Serum S. aureus CPS types 5 and 8 IgG levels were measured preinfusion and at various times after each infusion.
Of 206 neonates, 158 received both infusions. Adverse events were similar in the two treatment groups. Six subjects (3% in each group) discontinued owing to an adverse event. Geometric mean anti-type 5 IgG levels were 402 and 642 mcg/ml 1 day following infusion of the first (day 0) and Second (day 14) doses, respectively, in neonates < or =1000 g and slightly higher in neonates 1001 to 1500 g. Trough levels before second infusion were 188 mcg/ml. Type 8 IgG levels were similar. Geometric mean IgG levels among placebo recipients were consistently |
---|---|
ISSN: | 0743-8346 1476-5543 |