Colonoscopy aided by magnetic 3D imaging : assessing the routine use of a stiffening sigmoid overtube to speed up the procedure

There are not enough trained colonoscopists to cope with the present recommended number of examinations required for diagnostic and surveillance purposes. If colorectal cancer screening is to be introduced, endoscopic examination of the large bowel needs to be easier to learn and significantly quick...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical & biological engineering & computing 1999-09, Vol.37 (5), p.605-611
Hauptverfasser: BELL, G. D, ROWLAND, R. S, RUTTER, M, ABU-SADA, M, DOGRAMADZI, S, ALLEN, C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 611
container_issue 5
container_start_page 605
container_title Medical & biological engineering & computing
container_volume 37
creator BELL, G. D
ROWLAND, R. S
RUTTER, M
ABU-SADA, M
DOGRAMADZI, S
ALLEN, C
description There are not enough trained colonoscopists to cope with the present recommended number of examinations required for diagnostic and surveillance purposes. If colorectal cancer screening is to be introduced, endoscopic examination of the large bowel needs to be easier to learn and significantly quicker to carry out. The 'Bladen system', first described in 1993, is a non-radiological method of visualising the path of the endoscope, using magnetic drive coils under the patient and a chain of sensors along the biopsy channel of the instrument. In 1998, results were published using a novel computer graphics system (the RMR system), in which a much more realistic image of the endoscope could be produced using the stored positional data from the Bladen system. The RMR system has been further refined to allow, for the first time ever, accurate measurement of the effect of the passage of a colonoscope along the bowel on the lengths of different segments of the large intestine. The results obtained in 232 patients undergoing colonoscopy are analysed. In 77 of the patients, a stiffening overtube is used to splint the sigmoid colon once the endoscope is at or beyond the splenic flexure. The mean time taken to pass the colonoscope across the transverse colon is significantly shorter (p < 0.001) when an overtube is used, despite it resulting in significant lengthening of the transverse colon. The routine use of a stiffening overtube can be expected to reduce the total procedure time by between 10 and 20%.
doi_str_mv 10.1007/BF02513355
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_754883561</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>69453336</sourcerecordid><originalsourceid>FETCH-LOGICAL-c402t-d3d8f82f99f1a9e9bf318b5fb5c7ea2225ccbca636a7d69b820af421a2ab69e43</originalsourceid><addsrcrecordid>eNqF0c9rFDEUB_AgFrutXvwDJIgoCKP5OTPpTbfWFgpe9DxkMi9ryuxkzJsIe-q_btZdqHjQUxLyyffx8gh5ztk7zljz_uMVE5pLqfUjsuKN4hVTSj0mK8YVqxjn7Sk5Q7xjTHAt1BNyylkjZGvaFblfxzFOEV2cd9SGAQba7-jWbiZYgqPykoZyCNOGXlCLCIj7_fIdaIp5CRPQjECjp5biEryHaX-PYbONYaDxJ6Ql90CXSHGGEp7n34_nFB0MOcFTcuLtiPDsuJ6Tb1efvq6vq9svn2_WH24rp5hYqkEOrW-FN8Zza8D0XvK2177XrgErhNDO9c7WsrbNUJu-Fcx6JbgVtq8NKHlO3hxyS-UfGXDptgEdjKOdIGbsGq3aVuqaF_n6n7I2Sksp6_9CwZVkjO_hy7_gXcxpKu12tTJGy9rIgt4ekEsRMYHv5lS-Pu06zrr9mLuHMRf84piY-y0Mf9DDXAt4dQQWnR19spML-OBMI1Up_AuG0673</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>649953693</pqid></control><display><type>article</type><title>Colonoscopy aided by magnetic 3D imaging : assessing the routine use of a stiffening sigmoid overtube to speed up the procedure</title><source>MEDLINE</source><source>Springer Nature - Complete Springer Journals</source><creator>BELL, G. D ; ROWLAND, R. S ; RUTTER, M ; ABU-SADA, M ; DOGRAMADZI, S ; ALLEN, C</creator><creatorcontrib>BELL, G. D ; ROWLAND, R. S ; RUTTER, M ; ABU-SADA, M ; DOGRAMADZI, S ; ALLEN, C</creatorcontrib><description>There are not enough trained colonoscopists to cope with the present recommended number of examinations required for diagnostic and surveillance purposes. If colorectal cancer screening is to be introduced, endoscopic examination of the large bowel needs to be easier to learn and significantly quicker to carry out. The 'Bladen system', first described in 1993, is a non-radiological method of visualising the path of the endoscope, using magnetic drive coils under the patient and a chain of sensors along the biopsy channel of the instrument. In 1998, results were published using a novel computer graphics system (the RMR system), in which a much more realistic image of the endoscope could be produced using the stored positional data from the Bladen system. The RMR system has been further refined to allow, for the first time ever, accurate measurement of the effect of the passage of a colonoscope along the bowel on the lengths of different segments of the large intestine. The results obtained in 232 patients undergoing colonoscopy are analysed. In 77 of the patients, a stiffening overtube is used to splint the sigmoid colon once the endoscope is at or beyond the splenic flexure. The mean time taken to pass the colonoscope across the transverse colon is significantly shorter (p &lt; 0.001) when an overtube is used, despite it resulting in significant lengthening of the transverse colon. The routine use of a stiffening overtube can be expected to reduce the total procedure time by between 10 and 20%.</description><identifier>ISSN: 0140-0118</identifier><identifier>EISSN: 1741-0444</identifier><identifier>DOI: 10.1007/BF02513355</identifier><identifier>PMID: 10723898</identifier><language>eng</language><publisher>Heidelberg: Springer</publisher><subject>Adult ; Aged ; Biological and medical sciences ; Colon ; Colonoscopes ; Colonoscopy ; Colonoscopy - methods ; Colorectal cancer ; Colorectal Neoplasms - diagnosis ; Computer aided diagnosis ; Digestive system. Abdomen ; Endoscopy ; Female ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Magnetic devices ; Magnetics ; Male ; Medical sciences ; Medical screening ; Middle Aged ; Splints ; Time Factors</subject><ispartof>Medical &amp; biological engineering &amp; computing, 1999-09, Vol.37 (5), p.605-611</ispartof><rights>1999 INIST-CNRS</rights><rights>IFMBE 1999</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c402t-d3d8f82f99f1a9e9bf318b5fb5c7ea2225ccbca636a7d69b820af421a2ab69e43</citedby><cites>FETCH-LOGICAL-c402t-d3d8f82f99f1a9e9bf318b5fb5c7ea2225ccbca636a7d69b820af421a2ab69e43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1973495$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10723898$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>BELL, G. D</creatorcontrib><creatorcontrib>ROWLAND, R. S</creatorcontrib><creatorcontrib>RUTTER, M</creatorcontrib><creatorcontrib>ABU-SADA, M</creatorcontrib><creatorcontrib>DOGRAMADZI, S</creatorcontrib><creatorcontrib>ALLEN, C</creatorcontrib><title>Colonoscopy aided by magnetic 3D imaging : assessing the routine use of a stiffening sigmoid overtube to speed up the procedure</title><title>Medical &amp; biological engineering &amp; computing</title><addtitle>Med Biol Eng Comput</addtitle><description>There are not enough trained colonoscopists to cope with the present recommended number of examinations required for diagnostic and surveillance purposes. If colorectal cancer screening is to be introduced, endoscopic examination of the large bowel needs to be easier to learn and significantly quicker to carry out. The 'Bladen system', first described in 1993, is a non-radiological method of visualising the path of the endoscope, using magnetic drive coils under the patient and a chain of sensors along the biopsy channel of the instrument. In 1998, results were published using a novel computer graphics system (the RMR system), in which a much more realistic image of the endoscope could be produced using the stored positional data from the Bladen system. The RMR system has been further refined to allow, for the first time ever, accurate measurement of the effect of the passage of a colonoscope along the bowel on the lengths of different segments of the large intestine. The results obtained in 232 patients undergoing colonoscopy are analysed. In 77 of the patients, a stiffening overtube is used to splint the sigmoid colon once the endoscope is at or beyond the splenic flexure. The mean time taken to pass the colonoscope across the transverse colon is significantly shorter (p &lt; 0.001) when an overtube is used, despite it resulting in significant lengthening of the transverse colon. The routine use of a stiffening overtube can be expected to reduce the total procedure time by between 10 and 20%.</description><subject>Adult</subject><subject>Aged</subject><subject>Biological and medical sciences</subject><subject>Colon</subject><subject>Colonoscopes</subject><subject>Colonoscopy</subject><subject>Colonoscopy - methods</subject><subject>Colorectal cancer</subject><subject>Colorectal Neoplasms - diagnosis</subject><subject>Computer aided diagnosis</subject><subject>Digestive system. Abdomen</subject><subject>Endoscopy</subject><subject>Female</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Magnetic devices</subject><subject>Magnetics</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Medical screening</subject><subject>Middle Aged</subject><subject>Splints</subject><subject>Time Factors</subject><issn>0140-0118</issn><issn>1741-0444</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNqF0c9rFDEUB_AgFrutXvwDJIgoCKP5OTPpTbfWFgpe9DxkMi9ryuxkzJsIe-q_btZdqHjQUxLyyffx8gh5ztk7zljz_uMVE5pLqfUjsuKN4hVTSj0mK8YVqxjn7Sk5Q7xjTHAt1BNyylkjZGvaFblfxzFOEV2cd9SGAQba7-jWbiZYgqPykoZyCNOGXlCLCIj7_fIdaIp5CRPQjECjp5biEryHaX-PYbONYaDxJ6Ql90CXSHGGEp7n34_nFB0MOcFTcuLtiPDsuJ6Tb1efvq6vq9svn2_WH24rp5hYqkEOrW-FN8Zza8D0XvK2177XrgErhNDO9c7WsrbNUJu-Fcx6JbgVtq8NKHlO3hxyS-UfGXDptgEdjKOdIGbsGq3aVuqaF_n6n7I2Sksp6_9CwZVkjO_hy7_gXcxpKu12tTJGy9rIgt4ekEsRMYHv5lS-Pu06zrr9mLuHMRf84piY-y0Mf9DDXAt4dQQWnR19spML-OBMI1Up_AuG0673</recordid><startdate>19990901</startdate><enddate>19990901</enddate><creator>BELL, G. D</creator><creator>ROWLAND, R. S</creator><creator>RUTTER, M</creator><creator>ABU-SADA, M</creator><creator>DOGRAMADZI, S</creator><creator>ALLEN, C</creator><general>Springer</general><general>Springer Nature B.V</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7RV</scope><scope>7SC</scope><scope>7TB</scope><scope>7TS</scope><scope>7WY</scope><scope>7WZ</scope><scope>7X7</scope><scope>7XB</scope><scope>87Z</scope><scope>88A</scope><scope>88E</scope><scope>88I</scope><scope>8AL</scope><scope>8AO</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8FL</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BEZIV</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FR3</scope><scope>FRNLG</scope><scope>FYUFA</scope><scope>F~G</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>JQ2</scope><scope>K60</scope><scope>K6~</scope><scope>K7-</scope><scope>K9.</scope><scope>KB0</scope><scope>L.-</scope><scope>L7M</scope><scope>LK8</scope><scope>L~C</scope><scope>L~D</scope><scope>M0C</scope><scope>M0N</scope><scope>M0S</scope><scope>M1P</scope><scope>M2P</scope><scope>M7P</scope><scope>M7Z</scope><scope>NAPCQ</scope><scope>P5Z</scope><scope>P62</scope><scope>P64</scope><scope>PQBIZ</scope><scope>PQBZA</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>Q9U</scope><scope>7X8</scope><scope>7QO</scope></search><sort><creationdate>19990901</creationdate><title>Colonoscopy aided by magnetic 3D imaging : assessing the routine use of a stiffening sigmoid overtube to speed up the procedure</title><author>BELL, G. D ; ROWLAND, R. S ; RUTTER, M ; ABU-SADA, M ; DOGRAMADZI, S ; ALLEN, C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c402t-d3d8f82f99f1a9e9bf318b5fb5c7ea2225ccbca636a7d69b820af421a2ab69e43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Biological and medical sciences</topic><topic>Colon</topic><topic>Colonoscopes</topic><topic>Colonoscopy</topic><topic>Colonoscopy - methods</topic><topic>Colorectal cancer</topic><topic>Colorectal Neoplasms - diagnosis</topic><topic>Computer aided diagnosis</topic><topic>Digestive system. Abdomen</topic><topic>Endoscopy</topic><topic>Female</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Magnetic devices</topic><topic>Magnetics</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Medical screening</topic><topic>Middle Aged</topic><topic>Splints</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>BELL, G. D</creatorcontrib><creatorcontrib>ROWLAND, R. S</creatorcontrib><creatorcontrib>RUTTER, M</creatorcontrib><creatorcontrib>ABU-SADA, M</creatorcontrib><creatorcontrib>DOGRAMADZI, S</creatorcontrib><creatorcontrib>ALLEN, C</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Nursing &amp; Allied Health Database</collection><collection>Computer and Information Systems Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Physical Education Index</collection><collection>ABI/INFORM Collection</collection><collection>ABI/INFORM Global (PDF only)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ABI/INFORM Global (Alumni Edition)</collection><collection>Biology Database (Alumni Edition)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Science Database (Alumni Edition)</collection><collection>Computing Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ABI/INFORM Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Business Premium Collection</collection><collection>Technology Collection</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>Business Premium Collection (Alumni)</collection><collection>Health Research Premium Collection</collection><collection>ABI/INFORM Global (Corporate)</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Computer Science Collection</collection><collection>ProQuest Business Collection (Alumni Edition)</collection><collection>ProQuest Business Collection</collection><collection>Computer Science Database</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>ABI/INFORM Professional Advanced</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ProQuest Biological Science Collection</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>ABI/INFORM Global</collection><collection>Computing Database</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Science Database</collection><collection>Biological Science Database</collection><collection>Biochemistry Abstracts 1</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>Advanced Technologies &amp; Aerospace Database</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>ProQuest One Business</collection><collection>ProQuest One Business (Alumni)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><collection>Biotechnology Research Abstracts</collection><jtitle>Medical &amp; biological engineering &amp; computing</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>BELL, G. D</au><au>ROWLAND, R. S</au><au>RUTTER, M</au><au>ABU-SADA, M</au><au>DOGRAMADZI, S</au><au>ALLEN, C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Colonoscopy aided by magnetic 3D imaging : assessing the routine use of a stiffening sigmoid overtube to speed up the procedure</atitle><jtitle>Medical &amp; biological engineering &amp; computing</jtitle><addtitle>Med Biol Eng Comput</addtitle><date>1999-09-01</date><risdate>1999</risdate><volume>37</volume><issue>5</issue><spage>605</spage><epage>611</epage><pages>605-611</pages><issn>0140-0118</issn><eissn>1741-0444</eissn><abstract>There are not enough trained colonoscopists to cope with the present recommended number of examinations required for diagnostic and surveillance purposes. If colorectal cancer screening is to be introduced, endoscopic examination of the large bowel needs to be easier to learn and significantly quicker to carry out. The 'Bladen system', first described in 1993, is a non-radiological method of visualising the path of the endoscope, using magnetic drive coils under the patient and a chain of sensors along the biopsy channel of the instrument. In 1998, results were published using a novel computer graphics system (the RMR system), in which a much more realistic image of the endoscope could be produced using the stored positional data from the Bladen system. The RMR system has been further refined to allow, for the first time ever, accurate measurement of the effect of the passage of a colonoscope along the bowel on the lengths of different segments of the large intestine. The results obtained in 232 patients undergoing colonoscopy are analysed. In 77 of the patients, a stiffening overtube is used to splint the sigmoid colon once the endoscope is at or beyond the splenic flexure. The mean time taken to pass the colonoscope across the transverse colon is significantly shorter (p &lt; 0.001) when an overtube is used, despite it resulting in significant lengthening of the transverse colon. The routine use of a stiffening overtube can be expected to reduce the total procedure time by between 10 and 20%.</abstract><cop>Heidelberg</cop><pub>Springer</pub><pmid>10723898</pmid><doi>10.1007/BF02513355</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0140-0118
ispartof Medical & biological engineering & computing, 1999-09, Vol.37 (5), p.605-611
issn 0140-0118
1741-0444
language eng
recordid cdi_proquest_miscellaneous_754883561
source MEDLINE; Springer Nature - Complete Springer Journals
subjects Adult
Aged
Biological and medical sciences
Colon
Colonoscopes
Colonoscopy
Colonoscopy - methods
Colorectal cancer
Colorectal Neoplasms - diagnosis
Computer aided diagnosis
Digestive system. Abdomen
Endoscopy
Female
Humans
Investigative techniques, diagnostic techniques (general aspects)
Magnetic devices
Magnetics
Male
Medical sciences
Medical screening
Middle Aged
Splints
Time Factors
title Colonoscopy aided by magnetic 3D imaging : assessing the routine use of a stiffening sigmoid overtube to speed up the procedure
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T12%3A50%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Colonoscopy%20aided%20by%20magnetic%203D%20imaging%20:%20assessing%20the%20routine%20use%20of%20a%20stiffening%20sigmoid%20overtube%20to%20speed%20up%20the%20procedure&rft.jtitle=Medical%20&%20biological%20engineering%20&%20computing&rft.au=BELL,%20G.%20D&rft.date=1999-09-01&rft.volume=37&rft.issue=5&rft.spage=605&rft.epage=611&rft.pages=605-611&rft.issn=0140-0118&rft.eissn=1741-0444&rft_id=info:doi/10.1007/BF02513355&rft_dat=%3Cproquest_cross%3E69453336%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=649953693&rft_id=info:pmid/10723898&rfr_iscdi=true