Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method

A non-invasive technique is implemented to measure a peripheral vascular compliance index Cindex, using an infrared photoplethysmographic waveform as an indicator of intravascular volume change and a continuous blood pressure monitor to measure the blood pressure during each heart-beat. The non-line...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical & biological engineering & computing 1998-11, Vol.36 (6), p.748-753
Hauptverfasser: LOPEZ-BELTRAN, E. A, BLACKSHEAR, P. L, FINKELSTEIN, S. M, COHN, J. N
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 753
container_issue 6
container_start_page 748
container_title Medical & biological engineering & computing
container_volume 36
creator LOPEZ-BELTRAN, E. A
BLACKSHEAR, P. L
FINKELSTEIN, S. M
COHN, J. N
description A non-invasive technique is implemented to measure a peripheral vascular compliance index Cindex, using an infrared photoplethysmographic waveform as an indicator of intravascular volume change and a continuous blood pressure monitor to measure the blood pressure during each heart-beat. The non-linear behaviour of Cindex with pressure and the effect of age on Cindex are studied in 62 males (15-73 years). Repeatability tests and the effect of ice-water exposure of a portion of a limb are studied in 10 and 14 subjects, respectively. For each individual, Cindex measurements are taken at discrete values of local mean arterial pressure (Pmean), and a Cindex against Pmean plot is obtained. There is a statistically significant difference (p < 0.05) in Cindex for the lower values of Pmean (60-100 mmHg) between two age groups formed (15-52 and 58-73 years). The cold-pressor test (CPT) shows a 68% median decrease in Cindex, with an inter-quartile range of 60-77%, in a matter of seconds. The results suggest that Cindex may be a useful noninvasive indicator of peripheral vascular compliance in humans.
doi_str_mv 10.1007/bf02518879
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_754881789</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2090143221</sourcerecordid><originalsourceid>FETCH-LOGICAL-c501t-d8cef02d16644421a3cf9dd4fd4f7440f53fcebe1d01fddeab2e7cec1de44a8e3</originalsourceid><addsrcrecordid>eNqF0UFrFTEQB_Agin1WL34AWURUCquZbDbJHrVYWyh60fOSl0z6UnY3a7Jb6LfvlPdE8VAhEIb8ZmDyZ-wl8A_Auf64DVy0YIzuHrENaAk1l1I-ZhsOktccwByxZ6Vccy6gFfIpOwLeKC2V3rD4LU11nG5siTdYlWX1EUuVQjVjjvMOsx0qenTrYHPl0jgP0U4Oq7XE6aqy1UTtybmB-qied2lJ84DL7raM6SrbeRddNVKd_HP2JNih4IvDfcx-nn35cXpeX37_enH66bJ2LYel9sYh7eNBKVpCgG1c6LyXgY6Wkoe2CQ63CJ5D8B7tVqB26MCjlNZgc8ze7efOOf1asSz9GIvDYbATprX0upXGgDYdybcPStUJKehb_wsFNJ1s4B6-fxCC0iCFokP09T_0Oq15op_plWoaTsFyQid75HIqJWPo5xxHm2974P199v3ns9_ZE351mLhuR_R_0X3YBN4cAAVqh5ApyVj-uLZTQpnmDp0Vt68</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>663300070</pqid></control><display><type>article</type><title>Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method</title><source>MEDLINE</source><source>SpringerNature Journals</source><creator>LOPEZ-BELTRAN, E. A ; BLACKSHEAR, P. L ; FINKELSTEIN, S. M ; COHN, J. N</creator><creatorcontrib>LOPEZ-BELTRAN, E. A ; BLACKSHEAR, P. L ; FINKELSTEIN, S. M ; COHN, J. N</creatorcontrib><description>A non-invasive technique is implemented to measure a peripheral vascular compliance index Cindex, using an infrared photoplethysmographic waveform as an indicator of intravascular volume change and a continuous blood pressure monitor to measure the blood pressure during each heart-beat. The non-linear behaviour of Cindex with pressure and the effect of age on Cindex are studied in 62 males (15-73 years). Repeatability tests and the effect of ice-water exposure of a portion of a limb are studied in 10 and 14 subjects, respectively. For each individual, Cindex measurements are taken at discrete values of local mean arterial pressure (Pmean), and a Cindex against Pmean plot is obtained. There is a statistically significant difference (p &lt; 0.05) in Cindex for the lower values of Pmean (60-100 mmHg) between two age groups formed (15-52 and 58-73 years). The cold-pressor test (CPT) shows a 68% median decrease in Cindex, with an inter-quartile range of 60-77%, in a matter of seconds. The results suggest that Cindex may be a useful noninvasive indicator of peripheral vascular compliance in humans.</description><identifier>ISSN: 0140-0118</identifier><identifier>EISSN: 1741-0444</identifier><identifier>DOI: 10.1007/bf02518879</identifier><identifier>PMID: 10367467</identifier><language>eng</language><publisher>Heidelberg: Springer</publisher><subject>Adolescent ; Adult ; Age ; Aged ; Aging - physiology ; Biological and medical sciences ; Biomedical equipment ; Blood Pressure ; Compliance ; Fingers - blood supply ; Hemodynamics ; Humans ; Indicators ; Infrared ; Infrared devices ; Investigative techniques, diagnostic techniques (general aspects) ; Male ; Males ; Medical sciences ; Middle Aged ; Miscellaneous. Technology ; Monitors ; Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques ; Patient monitoring ; Photoplethysmography - methods ; Reproducibility ; Volume measurement ; Waveforms</subject><ispartof>Medical &amp; biological engineering &amp; computing, 1998-11, Vol.36 (6), p.748-753</ispartof><rights>1999 INIST-CNRS</rights><rights>IFMBE 1998</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c501t-d8cef02d16644421a3cf9dd4fd4f7440f53fcebe1d01fddeab2e7cec1de44a8e3</citedby><cites>FETCH-LOGICAL-c501t-d8cef02d16644421a3cf9dd4fd4f7440f53fcebe1d01fddeab2e7cec1de44a8e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1596268$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10367467$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>LOPEZ-BELTRAN, E. A</creatorcontrib><creatorcontrib>BLACKSHEAR, P. L</creatorcontrib><creatorcontrib>FINKELSTEIN, S. M</creatorcontrib><creatorcontrib>COHN, J. N</creatorcontrib><title>Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method</title><title>Medical &amp; biological engineering &amp; computing</title><addtitle>Med Biol Eng Comput</addtitle><description>A non-invasive technique is implemented to measure a peripheral vascular compliance index Cindex, using an infrared photoplethysmographic waveform as an indicator of intravascular volume change and a continuous blood pressure monitor to measure the blood pressure during each heart-beat. The non-linear behaviour of Cindex with pressure and the effect of age on Cindex are studied in 62 males (15-73 years). Repeatability tests and the effect of ice-water exposure of a portion of a limb are studied in 10 and 14 subjects, respectively. For each individual, Cindex measurements are taken at discrete values of local mean arterial pressure (Pmean), and a Cindex against Pmean plot is obtained. There is a statistically significant difference (p &lt; 0.05) in Cindex for the lower values of Pmean (60-100 mmHg) between two age groups formed (15-52 and 58-73 years). The cold-pressor test (CPT) shows a 68% median decrease in Cindex, with an inter-quartile range of 60-77%, in a matter of seconds. The results suggest that Cindex may be a useful noninvasive indicator of peripheral vascular compliance in humans.</description><subject>Adolescent</subject><subject>Adult</subject><subject>Age</subject><subject>Aged</subject><subject>Aging - physiology</subject><subject>Biological and medical sciences</subject><subject>Biomedical equipment</subject><subject>Blood Pressure</subject><subject>Compliance</subject><subject>Fingers - blood supply</subject><subject>Hemodynamics</subject><subject>Humans</subject><subject>Indicators</subject><subject>Infrared</subject><subject>Infrared devices</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Male</subject><subject>Males</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Miscellaneous. Technology</subject><subject>Monitors</subject><subject>Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques</subject><subject>Patient monitoring</subject><subject>Photoplethysmography - methods</subject><subject>Reproducibility</subject><subject>Volume measurement</subject><subject>Waveforms</subject><issn>0140-0118</issn><issn>1741-0444</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNqF0UFrFTEQB_Agin1WL34AWURUCquZbDbJHrVYWyh60fOSl0z6UnY3a7Jb6LfvlPdE8VAhEIb8ZmDyZ-wl8A_Auf64DVy0YIzuHrENaAk1l1I-ZhsOktccwByxZ6Vccy6gFfIpOwLeKC2V3rD4LU11nG5siTdYlWX1EUuVQjVjjvMOsx0qenTrYHPl0jgP0U4Oq7XE6aqy1UTtybmB-qied2lJ84DL7raM6SrbeRddNVKd_HP2JNih4IvDfcx-nn35cXpeX37_enH66bJ2LYel9sYh7eNBKVpCgG1c6LyXgY6Wkoe2CQ63CJ5D8B7tVqB26MCjlNZgc8ze7efOOf1asSz9GIvDYbATprX0upXGgDYdybcPStUJKehb_wsFNJ1s4B6-fxCC0iCFokP09T_0Oq15op_plWoaTsFyQid75HIqJWPo5xxHm2974P199v3ns9_ZE351mLhuR_R_0X3YBN4cAAVqh5ApyVj-uLZTQpnmDp0Vt68</recordid><startdate>19981101</startdate><enddate>19981101</enddate><creator>LOPEZ-BELTRAN, E. A</creator><creator>BLACKSHEAR, P. L</creator><creator>FINKELSTEIN, S. M</creator><creator>COHN, J. N</creator><general>Springer</general><general>Springer Nature B.V</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7RV</scope><scope>7SC</scope><scope>7TB</scope><scope>7TS</scope><scope>7WY</scope><scope>7WZ</scope><scope>7X7</scope><scope>7XB</scope><scope>87Z</scope><scope>88A</scope><scope>88E</scope><scope>88I</scope><scope>8AL</scope><scope>8AO</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8FL</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BEZIV</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FR3</scope><scope>FRNLG</scope><scope>FYUFA</scope><scope>F~G</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>JQ2</scope><scope>K60</scope><scope>K6~</scope><scope>K7-</scope><scope>K9.</scope><scope>KB0</scope><scope>L.-</scope><scope>L7M</scope><scope>LK8</scope><scope>L~C</scope><scope>L~D</scope><scope>M0C</scope><scope>M0N</scope><scope>M0S</scope><scope>M1P</scope><scope>M2P</scope><scope>M7P</scope><scope>M7Z</scope><scope>NAPCQ</scope><scope>P5Z</scope><scope>P62</scope><scope>P64</scope><scope>PQBIZ</scope><scope>PQBZA</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>Q9U</scope><scope>7X8</scope><scope>7QO</scope></search><sort><creationdate>19981101</creationdate><title>Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method</title><author>LOPEZ-BELTRAN, E. A ; BLACKSHEAR, P. L ; FINKELSTEIN, S. M ; COHN, J. N</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c501t-d8cef02d16644421a3cf9dd4fd4f7440f53fcebe1d01fddeab2e7cec1de44a8e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>Age</topic><topic>Aged</topic><topic>Aging - physiology</topic><topic>Biological and medical sciences</topic><topic>Biomedical equipment</topic><topic>Blood Pressure</topic><topic>Compliance</topic><topic>Fingers - blood supply</topic><topic>Hemodynamics</topic><topic>Humans</topic><topic>Indicators</topic><topic>Infrared</topic><topic>Infrared devices</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Male</topic><topic>Males</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Miscellaneous. Technology</topic><topic>Monitors</topic><topic>Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques</topic><topic>Patient monitoring</topic><topic>Photoplethysmography - methods</topic><topic>Reproducibility</topic><topic>Volume measurement</topic><topic>Waveforms</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>LOPEZ-BELTRAN, E. A</creatorcontrib><creatorcontrib>BLACKSHEAR, P. L</creatorcontrib><creatorcontrib>FINKELSTEIN, S. M</creatorcontrib><creatorcontrib>COHN, J. N</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Proquest Nursing &amp; Allied Health Source</collection><collection>Computer and Information Systems Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Physical Education Index</collection><collection>Access via ABI/INFORM (ProQuest)</collection><collection>ABI/INFORM Global (PDF only)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ABI/INFORM Global (Alumni Edition)</collection><collection>Biology Database (Alumni Edition)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Science Database (Alumni Edition)</collection><collection>Computing Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ABI/INFORM Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Business Premium Collection</collection><collection>Technology Collection</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>Business Premium Collection (Alumni)</collection><collection>Health Research Premium Collection</collection><collection>ABI/INFORM Global (Corporate)</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Computer Science Collection</collection><collection>ProQuest Business Collection (Alumni Edition)</collection><collection>ProQuest Business Collection</collection><collection>Computer Science Database</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>ABI/INFORM Professional Advanced</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ProQuest Biological Science Collection</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>ABI/INFORM Global</collection><collection>Computing Database</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Science Database</collection><collection>Biological Science Database</collection><collection>Biochemistry Abstracts 1</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>Advanced Technologies &amp; Aerospace Database</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>ProQuest One Business</collection><collection>ProQuest One Business (Alumni)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><collection>Biotechnology Research Abstracts</collection><jtitle>Medical &amp; biological engineering &amp; computing</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>LOPEZ-BELTRAN, E. A</au><au>BLACKSHEAR, P. L</au><au>FINKELSTEIN, S. M</au><au>COHN, J. N</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method</atitle><jtitle>Medical &amp; biological engineering &amp; computing</jtitle><addtitle>Med Biol Eng Comput</addtitle><date>1998-11-01</date><risdate>1998</risdate><volume>36</volume><issue>6</issue><spage>748</spage><epage>753</epage><pages>748-753</pages><issn>0140-0118</issn><eissn>1741-0444</eissn><abstract>A non-invasive technique is implemented to measure a peripheral vascular compliance index Cindex, using an infrared photoplethysmographic waveform as an indicator of intravascular volume change and a continuous blood pressure monitor to measure the blood pressure during each heart-beat. The non-linear behaviour of Cindex with pressure and the effect of age on Cindex are studied in 62 males (15-73 years). Repeatability tests and the effect of ice-water exposure of a portion of a limb are studied in 10 and 14 subjects, respectively. For each individual, Cindex measurements are taken at discrete values of local mean arterial pressure (Pmean), and a Cindex against Pmean plot is obtained. There is a statistically significant difference (p &lt; 0.05) in Cindex for the lower values of Pmean (60-100 mmHg) between two age groups formed (15-52 and 58-73 years). The cold-pressor test (CPT) shows a 68% median decrease in Cindex, with an inter-quartile range of 60-77%, in a matter of seconds. The results suggest that Cindex may be a useful noninvasive indicator of peripheral vascular compliance in humans.</abstract><cop>Heidelberg</cop><pub>Springer</pub><pmid>10367467</pmid><doi>10.1007/bf02518879</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0140-0118
ispartof Medical & biological engineering & computing, 1998-11, Vol.36 (6), p.748-753
issn 0140-0118
1741-0444
language eng
recordid cdi_proquest_miscellaneous_754881789
source MEDLINE; SpringerNature Journals
subjects Adolescent
Adult
Age
Aged
Aging - physiology
Biological and medical sciences
Biomedical equipment
Blood Pressure
Compliance
Fingers - blood supply
Hemodynamics
Humans
Indicators
Infrared
Infrared devices
Investigative techniques, diagnostic techniques (general aspects)
Male
Males
Medical sciences
Middle Aged
Miscellaneous. Technology
Monitors
Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques
Patient monitoring
Photoplethysmography - methods
Reproducibility
Volume measurement
Waveforms
title Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T08%3A46%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Non-invasive%20studies%20of%20peripheral%20vascular%20compliance%20using%20a%20non-occluding%20photoplethysmographic%20method&rft.jtitle=Medical%20&%20biological%20engineering%20&%20computing&rft.au=LOPEZ-BELTRAN,%20E.%20A&rft.date=1998-11-01&rft.volume=36&rft.issue=6&rft.spage=748&rft.epage=753&rft.pages=748-753&rft.issn=0140-0118&rft.eissn=1741-0444&rft_id=info:doi/10.1007/bf02518879&rft_dat=%3Cproquest_cross%3E2090143221%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=663300070&rft_id=info:pmid/10367467&rfr_iscdi=true