Biological Thermal Detection: Micromechanical and Microthermal Properties of Biological Infrared Receptors
Bioinspired design of biomimetic sensors relies upon the complete understanding of properties and functioning of biological analogues in conjunction with an understanding of their microstructural organization at various length scales. In the spirit of this approach, the microscopic properties of inf...
Gespeichert in:
Veröffentlicht in: | Biomacromolecules 2002-01, Vol.3 (1), p.106-115 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 115 |
---|---|
container_issue | 1 |
container_start_page | 106 |
container_title | Biomacromolecules |
container_volume | 3 |
creator | Gorbunov, V Fuchigami, N Stone, M Grace, M Tsukruk, V. V |
description | Bioinspired design of biomimetic sensors relies upon the complete understanding of properties and functioning of biological analogues in conjunction with an understanding of their microstructural organization at various length scales. In the spirit of this approach, the microscopic properties of infrared (IR) receptors of snakes with “infrared vision” were studied with scanning thermal microscopy and micromechanical analysis. Low surface thermal conductivity of 0.11 W/(m K) was measured for the IR receptor surfaces as compared to the nonspecific skin areas. This difference in surface thermal conductivity should result in a significant local temperature gradient around the receptor areas. Micromechanical analysis showed that pit organs were more compliant than surrounding skin areas with an elastic modulus close to 40 MPa. In addition, the maximum elastic modulus was detected for the outermost layer with gradually reduced elastic resistance for the interior. The porous microstructure of the underlying tissue combined with the highly branched microfibrillar network (Biomacromolecules 2001, 2, 757) is thought to be responsible for such a combination of biomaterial properties. Considering these biomaterials features, we postulated a possible design of an artificial photothermal detector inspired by the microstructure of natural receptors. This bioinspired design would include a microfabricated cavity filled with an ordered lattice of microspheres with a gradient periodicity from the surface to the interior. Such a “photonic cavity” could provide an opportunity for multiple scattering at wavelength tuned to 8−12 μm as a range of highest sensitivity. |
doi_str_mv | 10.1021/bm015591f |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_754548970</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>754548970</sourcerecordid><originalsourceid>FETCH-LOGICAL-a343t-14e15605c6e7469f67607558cb89f72c97af62b5cf83b29adae087b4253a462d3</originalsourceid><addsrcrecordid>eNp90b1OwzAQB3ALgWgpDLwAygKIIWA7_ojZoHxVAoFQmSPHOdNUSVzsdGBj5TV5EkJbAQNiutPpp790dwjtEnxMMCUneY0J54rYNdQnnIqYCUzXFz2PpVSyh7ZCmGKMVcL4JuoRkgrBBe2j-rx0lXsuja6i8QR83dULaMG0pWtOP97eo7vSeFeDmehmoXRTLGftij94NwPflhAiZ6NfeaPGeu2hiB7BwKx1PmyjDaurADurOkBPV5fj4U18e389Gp7dxjphSRsTBoQLzI0AyYSyQgosOU9NniorqVFSW0Fzbmya5FTpQgNOZc4oTzQTtEgG6HCZO_PuZQ6hzeoyGKgq3YCbh0xyxlmqJO7kwf-SdA4r0sGjJew2D8GDzWa-rLV_zQjOvr6QfX-hs3ur0HleQ_EjV2fvwP4SaBOyqZv7prvGH0GfRgePbg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>71489091</pqid></control><display><type>article</type><title>Biological Thermal Detection: Micromechanical and Microthermal Properties of Biological Infrared Receptors</title><source>MEDLINE</source><source>American Chemical Society Journals</source><creator>Gorbunov, V ; Fuchigami, N ; Stone, M ; Grace, M ; Tsukruk, V. V</creator><creatorcontrib>Gorbunov, V ; Fuchigami, N ; Stone, M ; Grace, M ; Tsukruk, V. V</creatorcontrib><description>Bioinspired design of biomimetic sensors relies upon the complete understanding of properties and functioning of biological analogues in conjunction with an understanding of their microstructural organization at various length scales. In the spirit of this approach, the microscopic properties of infrared (IR) receptors of snakes with “infrared vision” were studied with scanning thermal microscopy and micromechanical analysis. Low surface thermal conductivity of 0.11 W/(m K) was measured for the IR receptor surfaces as compared to the nonspecific skin areas. This difference in surface thermal conductivity should result in a significant local temperature gradient around the receptor areas. Micromechanical analysis showed that pit organs were more compliant than surrounding skin areas with an elastic modulus close to 40 MPa. In addition, the maximum elastic modulus was detected for the outermost layer with gradually reduced elastic resistance for the interior. The porous microstructure of the underlying tissue combined with the highly branched microfibrillar network (Biomacromolecules 2001, 2, 757) is thought to be responsible for such a combination of biomaterial properties. Considering these biomaterials features, we postulated a possible design of an artificial photothermal detector inspired by the microstructure of natural receptors. This bioinspired design would include a microfabricated cavity filled with an ordered lattice of microspheres with a gradient periodicity from the surface to the interior. Such a “photonic cavity” could provide an opportunity for multiple scattering at wavelength tuned to 8−12 μm as a range of highest sensitivity.</description><identifier>ISSN: 1525-7797</identifier><identifier>EISSN: 1526-4602</identifier><identifier>DOI: 10.1021/bm015591f</identifier><identifier>PMID: 11866562</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><subject>Animals ; Boidae - physiology ; Fixatives ; Formaldehyde ; Infrared Rays ; Macromolecular Substances ; Microscopy, Electron ; Microscopy, Scanning Probe ; Sensory Receptor Cells - physiology ; Sensory Receptor Cells - ultrastructure ; Skin - ultrastructure ; Thermal Conductivity</subject><ispartof>Biomacromolecules, 2002-01, Vol.3 (1), p.106-115</ispartof><rights>Copyright © 2002 American Chemical Society</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a343t-14e15605c6e7469f67607558cb89f72c97af62b5cf83b29adae087b4253a462d3</citedby><cites>FETCH-LOGICAL-a343t-14e15605c6e7469f67607558cb89f72c97af62b5cf83b29adae087b4253a462d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/bm015591f$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/bm015591f$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,780,784,2763,27074,27922,27923,56736,56786</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11866562$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gorbunov, V</creatorcontrib><creatorcontrib>Fuchigami, N</creatorcontrib><creatorcontrib>Stone, M</creatorcontrib><creatorcontrib>Grace, M</creatorcontrib><creatorcontrib>Tsukruk, V. V</creatorcontrib><title>Biological Thermal Detection: Micromechanical and Microthermal Properties of Biological Infrared Receptors</title><title>Biomacromolecules</title><addtitle>Biomacromolecules</addtitle><description>Bioinspired design of biomimetic sensors relies upon the complete understanding of properties and functioning of biological analogues in conjunction with an understanding of their microstructural organization at various length scales. In the spirit of this approach, the microscopic properties of infrared (IR) receptors of snakes with “infrared vision” were studied with scanning thermal microscopy and micromechanical analysis. Low surface thermal conductivity of 0.11 W/(m K) was measured for the IR receptor surfaces as compared to the nonspecific skin areas. This difference in surface thermal conductivity should result in a significant local temperature gradient around the receptor areas. Micromechanical analysis showed that pit organs were more compliant than surrounding skin areas with an elastic modulus close to 40 MPa. In addition, the maximum elastic modulus was detected for the outermost layer with gradually reduced elastic resistance for the interior. The porous microstructure of the underlying tissue combined with the highly branched microfibrillar network (Biomacromolecules 2001, 2, 757) is thought to be responsible for such a combination of biomaterial properties. Considering these biomaterials features, we postulated a possible design of an artificial photothermal detector inspired by the microstructure of natural receptors. This bioinspired design would include a microfabricated cavity filled with an ordered lattice of microspheres with a gradient periodicity from the surface to the interior. Such a “photonic cavity” could provide an opportunity for multiple scattering at wavelength tuned to 8−12 μm as a range of highest sensitivity.</description><subject>Animals</subject><subject>Boidae - physiology</subject><subject>Fixatives</subject><subject>Formaldehyde</subject><subject>Infrared Rays</subject><subject>Macromolecular Substances</subject><subject>Microscopy, Electron</subject><subject>Microscopy, Scanning Probe</subject><subject>Sensory Receptor Cells - physiology</subject><subject>Sensory Receptor Cells - ultrastructure</subject><subject>Skin - ultrastructure</subject><subject>Thermal Conductivity</subject><issn>1525-7797</issn><issn>1526-4602</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp90b1OwzAQB3ALgWgpDLwAygKIIWA7_ojZoHxVAoFQmSPHOdNUSVzsdGBj5TV5EkJbAQNiutPpp790dwjtEnxMMCUneY0J54rYNdQnnIqYCUzXFz2PpVSyh7ZCmGKMVcL4JuoRkgrBBe2j-rx0lXsuja6i8QR83dULaMG0pWtOP97eo7vSeFeDmehmoXRTLGftij94NwPflhAiZ6NfeaPGeu2hiB7BwKx1PmyjDaurADurOkBPV5fj4U18e389Gp7dxjphSRsTBoQLzI0AyYSyQgosOU9NniorqVFSW0Fzbmya5FTpQgNOZc4oTzQTtEgG6HCZO_PuZQ6hzeoyGKgq3YCbh0xyxlmqJO7kwf-SdA4r0sGjJew2D8GDzWa-rLV_zQjOvr6QfX-hs3ur0HleQ_EjV2fvwP4SaBOyqZv7prvGH0GfRgePbg</recordid><startdate>20020101</startdate><enddate>20020101</enddate><creator>Gorbunov, V</creator><creator>Fuchigami, N</creator><creator>Stone, M</creator><creator>Grace, M</creator><creator>Tsukruk, V. V</creator><general>American Chemical Society</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>20020101</creationdate><title>Biological Thermal Detection: Micromechanical and Microthermal Properties of Biological Infrared Receptors</title><author>Gorbunov, V ; Fuchigami, N ; Stone, M ; Grace, M ; Tsukruk, V. V</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a343t-14e15605c6e7469f67607558cb89f72c97af62b5cf83b29adae087b4253a462d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Animals</topic><topic>Boidae - physiology</topic><topic>Fixatives</topic><topic>Formaldehyde</topic><topic>Infrared Rays</topic><topic>Macromolecular Substances</topic><topic>Microscopy, Electron</topic><topic>Microscopy, Scanning Probe</topic><topic>Sensory Receptor Cells - physiology</topic><topic>Sensory Receptor Cells - ultrastructure</topic><topic>Skin - ultrastructure</topic><topic>Thermal Conductivity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gorbunov, V</creatorcontrib><creatorcontrib>Fuchigami, N</creatorcontrib><creatorcontrib>Stone, M</creatorcontrib><creatorcontrib>Grace, M</creatorcontrib><creatorcontrib>Tsukruk, V. V</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Biomacromolecules</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gorbunov, V</au><au>Fuchigami, N</au><au>Stone, M</au><au>Grace, M</au><au>Tsukruk, V. V</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Biological Thermal Detection: Micromechanical and Microthermal Properties of Biological Infrared Receptors</atitle><jtitle>Biomacromolecules</jtitle><addtitle>Biomacromolecules</addtitle><date>2002-01-01</date><risdate>2002</risdate><volume>3</volume><issue>1</issue><spage>106</spage><epage>115</epage><pages>106-115</pages><issn>1525-7797</issn><eissn>1526-4602</eissn><abstract>Bioinspired design of biomimetic sensors relies upon the complete understanding of properties and functioning of biological analogues in conjunction with an understanding of their microstructural organization at various length scales. In the spirit of this approach, the microscopic properties of infrared (IR) receptors of snakes with “infrared vision” were studied with scanning thermal microscopy and micromechanical analysis. Low surface thermal conductivity of 0.11 W/(m K) was measured for the IR receptor surfaces as compared to the nonspecific skin areas. This difference in surface thermal conductivity should result in a significant local temperature gradient around the receptor areas. Micromechanical analysis showed that pit organs were more compliant than surrounding skin areas with an elastic modulus close to 40 MPa. In addition, the maximum elastic modulus was detected for the outermost layer with gradually reduced elastic resistance for the interior. The porous microstructure of the underlying tissue combined with the highly branched microfibrillar network (Biomacromolecules 2001, 2, 757) is thought to be responsible for such a combination of biomaterial properties. Considering these biomaterials features, we postulated a possible design of an artificial photothermal detector inspired by the microstructure of natural receptors. This bioinspired design would include a microfabricated cavity filled with an ordered lattice of microspheres with a gradient periodicity from the surface to the interior. Such a “photonic cavity” could provide an opportunity for multiple scattering at wavelength tuned to 8−12 μm as a range of highest sensitivity.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>11866562</pmid><doi>10.1021/bm015591f</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1525-7797 |
ispartof | Biomacromolecules, 2002-01, Vol.3 (1), p.106-115 |
issn | 1525-7797 1526-4602 |
language | eng |
recordid | cdi_proquest_miscellaneous_754548970 |
source | MEDLINE; American Chemical Society Journals |
subjects | Animals Boidae - physiology Fixatives Formaldehyde Infrared Rays Macromolecular Substances Microscopy, Electron Microscopy, Scanning Probe Sensory Receptor Cells - physiology Sensory Receptor Cells - ultrastructure Skin - ultrastructure Thermal Conductivity |
title | Biological Thermal Detection: Micromechanical and Microthermal Properties of Biological Infrared Receptors |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T14%3A53%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Biological%20Thermal%20Detection:%E2%80%89%20Micromechanical%20and%20Microthermal%20Properties%20of%20Biological%20Infrared%20Receptors&rft.jtitle=Biomacromolecules&rft.au=Gorbunov,%20V&rft.date=2002-01-01&rft.volume=3&rft.issue=1&rft.spage=106&rft.epage=115&rft.pages=106-115&rft.issn=1525-7797&rft.eissn=1526-4602&rft_id=info:doi/10.1021/bm015591f&rft_dat=%3Cproquest_cross%3E754548970%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=71489091&rft_id=info:pmid/11866562&rfr_iscdi=true |