Effect of daily setup errors on individual dose distribution in conventional radiotherapy: an initial study

Recent linear accelerators can perform cone-beam computed tomography to correct setup errors immediately before dose delivery. We calculated the dose distribution with setup errors acquired from cone-beam computed tomography to determine a more realistic and individual effect of setup errors. The di...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiological physics and technology 2009-07, Vol.2 (2), p.151-158
Hauptverfasser: Takemura, Akihiro, Shoji, Saori, Ueda, Sinichi, Kurata, Yuichi, Kumano, Tomoyasu, Takamatsu, Shigeyuki, Suzuki, Masayuki
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 158
container_issue 2
container_start_page 151
container_title Radiological physics and technology
container_volume 2
creator Takemura, Akihiro
Shoji, Saori
Ueda, Sinichi
Kurata, Yuichi
Kumano, Tomoyasu
Takamatsu, Shigeyuki
Suzuki, Masayuki
description Recent linear accelerators can perform cone-beam computed tomography to correct setup errors immediately before dose delivery. We calculated the dose distribution with setup errors acquired from cone-beam computed tomography to determine a more realistic and individual effect of setup errors. The differences in dose distribution were analyzed. The setup errors of three patients who were irradiated in the neck, esophagus, and pelvic area were obtained retrospectively. We found that the maximum dose variances for the three cases were 19.9–35.9%. The maximum dose variance points were relatively far from the isocenter. The volume of the 10% dose difference had widths of 1.3–1.85 cm around the beam edges. The V95 and mean doses at the clinical target volume were mostly unchanged. Doses around the beam edges were more varied than those around the isocenter for every case. The dose on the spinal cord located near the beam edges varied by 5–10% compared with the dose of the radiotherapy plan in two of the cases. We demonstrated the individual dose distributions of the cases affected by daily setup errors for all fractions.
doi_str_mv 10.1007/s12194-009-0059-0
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_754022017</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>754022017</sourcerecordid><originalsourceid>FETCH-LOGICAL-c411t-548f2ae532cb7ac0e2c6cde8296e85168d4db6daf56feee35738f51948f60cdd3</originalsourceid><addsrcrecordid>eNp9kE9PwyAYh4nRuDn9AF4MN09VoKXtvBkz_yRLvOiZMHhRZlcq0CX79lI7d_QAvOT3vL_Dg9AlJTeUkOo2UEbnRUbIPB2eriM0pXXJM5IX9Pgw5_kEnYWwJqSkjLFTNGGkZpTSYoq-FsaAitgZrKVtdjhA7DsM3jsfsGuxbbXdWt3LBmsXAGsborerPtrfECvXbqEdfonwUlsXP8HLbneH5QDYaFMQYq935-jEyCbAxf6doffHxdvDc7Z8fXp5uF9mqqA0ZryoDZPAc6ZWlVQEmCqVhprNS6g5LWtd6FWppeGlAYCcV3lteBJRm5IorfMZuh57O---ewhRbGxQ0DSyBdcHUfGCMEZolUg6ksq7EDwY0Xm7kX4nKBGDYjEqFkmxGBQLknau9u39agP6sPHnNAFsBEKK2g_wYu16n_SEf1p_AAROiRY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>754022017</pqid></control><display><type>article</type><title>Effect of daily setup errors on individual dose distribution in conventional radiotherapy: an initial study</title><source>MEDLINE</source><source>Springer Nature - Complete Springer Journals</source><creator>Takemura, Akihiro ; Shoji, Saori ; Ueda, Sinichi ; Kurata, Yuichi ; Kumano, Tomoyasu ; Takamatsu, Shigeyuki ; Suzuki, Masayuki</creator><creatorcontrib>Takemura, Akihiro ; Shoji, Saori ; Ueda, Sinichi ; Kurata, Yuichi ; Kumano, Tomoyasu ; Takamatsu, Shigeyuki ; Suzuki, Masayuki</creatorcontrib><description>Recent linear accelerators can perform cone-beam computed tomography to correct setup errors immediately before dose delivery. We calculated the dose distribution with setup errors acquired from cone-beam computed tomography to determine a more realistic and individual effect of setup errors. The differences in dose distribution were analyzed. The setup errors of three patients who were irradiated in the neck, esophagus, and pelvic area were obtained retrospectively. We found that the maximum dose variances for the three cases were 19.9–35.9%. The maximum dose variance points were relatively far from the isocenter. The volume of the 10% dose difference had widths of 1.3–1.85 cm around the beam edges. The V95 and mean doses at the clinical target volume were mostly unchanged. Doses around the beam edges were more varied than those around the isocenter for every case. The dose on the spinal cord located near the beam edges varied by 5–10% compared with the dose of the radiotherapy plan in two of the cases. We demonstrated the individual dose distributions of the cases affected by daily setup errors for all fractions.</description><identifier>ISSN: 1865-0333</identifier><identifier>EISSN: 1865-0341</identifier><identifier>DOI: 10.1007/s12194-009-0059-0</identifier><identifier>PMID: 20821114</identifier><language>eng</language><publisher>Tokyo: Springer Japan</publisher><subject>Aged ; Cone-Beam Computed Tomography ; Dose Fractionation ; Female ; Humans ; Imaging ; Imaging, Three-Dimensional ; Male ; Medical and Radiation Physics ; Medical Errors ; Medicine ; Medicine &amp; Public Health ; Middle Aged ; Neoplasms - diagnostic imaging ; Neoplasms - radiotherapy ; Nuclear Medicine ; Radiology ; Radiotherapy ; Retrospective Studies ; Time Factors</subject><ispartof>Radiological physics and technology, 2009-07, Vol.2 (2), p.151-158</ispartof><rights>Japanese Society of Radiological Technology and Japan Society of Medical Physics 2009</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c411t-548f2ae532cb7ac0e2c6cde8296e85168d4db6daf56feee35738f51948f60cdd3</citedby><cites>FETCH-LOGICAL-c411t-548f2ae532cb7ac0e2c6cde8296e85168d4db6daf56feee35738f51948f60cdd3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s12194-009-0059-0$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s12194-009-0059-0$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,41464,42533,51294</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20821114$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Takemura, Akihiro</creatorcontrib><creatorcontrib>Shoji, Saori</creatorcontrib><creatorcontrib>Ueda, Sinichi</creatorcontrib><creatorcontrib>Kurata, Yuichi</creatorcontrib><creatorcontrib>Kumano, Tomoyasu</creatorcontrib><creatorcontrib>Takamatsu, Shigeyuki</creatorcontrib><creatorcontrib>Suzuki, Masayuki</creatorcontrib><title>Effect of daily setup errors on individual dose distribution in conventional radiotherapy: an initial study</title><title>Radiological physics and technology</title><addtitle>Radiol Phys Technol</addtitle><addtitle>Radiol Phys Technol</addtitle><description>Recent linear accelerators can perform cone-beam computed tomography to correct setup errors immediately before dose delivery. We calculated the dose distribution with setup errors acquired from cone-beam computed tomography to determine a more realistic and individual effect of setup errors. The differences in dose distribution were analyzed. The setup errors of three patients who were irradiated in the neck, esophagus, and pelvic area were obtained retrospectively. We found that the maximum dose variances for the three cases were 19.9–35.9%. The maximum dose variance points were relatively far from the isocenter. The volume of the 10% dose difference had widths of 1.3–1.85 cm around the beam edges. The V95 and mean doses at the clinical target volume were mostly unchanged. Doses around the beam edges were more varied than those around the isocenter for every case. The dose on the spinal cord located near the beam edges varied by 5–10% compared with the dose of the radiotherapy plan in two of the cases. We demonstrated the individual dose distributions of the cases affected by daily setup errors for all fractions.</description><subject>Aged</subject><subject>Cone-Beam Computed Tomography</subject><subject>Dose Fractionation</subject><subject>Female</subject><subject>Humans</subject><subject>Imaging</subject><subject>Imaging, Three-Dimensional</subject><subject>Male</subject><subject>Medical and Radiation Physics</subject><subject>Medical Errors</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Middle Aged</subject><subject>Neoplasms - diagnostic imaging</subject><subject>Neoplasms - radiotherapy</subject><subject>Nuclear Medicine</subject><subject>Radiology</subject><subject>Radiotherapy</subject><subject>Retrospective Studies</subject><subject>Time Factors</subject><issn>1865-0333</issn><issn>1865-0341</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE9PwyAYh4nRuDn9AF4MN09VoKXtvBkz_yRLvOiZMHhRZlcq0CX79lI7d_QAvOT3vL_Dg9AlJTeUkOo2UEbnRUbIPB2eriM0pXXJM5IX9Pgw5_kEnYWwJqSkjLFTNGGkZpTSYoq-FsaAitgZrKVtdjhA7DsM3jsfsGuxbbXdWt3LBmsXAGsborerPtrfECvXbqEdfonwUlsXP8HLbneH5QDYaFMQYq935-jEyCbAxf6doffHxdvDc7Z8fXp5uF9mqqA0ZryoDZPAc6ZWlVQEmCqVhprNS6g5LWtd6FWppeGlAYCcV3lteBJRm5IorfMZuh57O---ewhRbGxQ0DSyBdcHUfGCMEZolUg6ksq7EDwY0Xm7kX4nKBGDYjEqFkmxGBQLknau9u39agP6sPHnNAFsBEKK2g_wYu16n_SEf1p_AAROiRY</recordid><startdate>20090701</startdate><enddate>20090701</enddate><creator>Takemura, Akihiro</creator><creator>Shoji, Saori</creator><creator>Ueda, Sinichi</creator><creator>Kurata, Yuichi</creator><creator>Kumano, Tomoyasu</creator><creator>Takamatsu, Shigeyuki</creator><creator>Suzuki, Masayuki</creator><general>Springer Japan</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20090701</creationdate><title>Effect of daily setup errors on individual dose distribution in conventional radiotherapy: an initial study</title><author>Takemura, Akihiro ; Shoji, Saori ; Ueda, Sinichi ; Kurata, Yuichi ; Kumano, Tomoyasu ; Takamatsu, Shigeyuki ; Suzuki, Masayuki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c411t-548f2ae532cb7ac0e2c6cde8296e85168d4db6daf56feee35738f51948f60cdd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Aged</topic><topic>Cone-Beam Computed Tomography</topic><topic>Dose Fractionation</topic><topic>Female</topic><topic>Humans</topic><topic>Imaging</topic><topic>Imaging, Three-Dimensional</topic><topic>Male</topic><topic>Medical and Radiation Physics</topic><topic>Medical Errors</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Middle Aged</topic><topic>Neoplasms - diagnostic imaging</topic><topic>Neoplasms - radiotherapy</topic><topic>Nuclear Medicine</topic><topic>Radiology</topic><topic>Radiotherapy</topic><topic>Retrospective Studies</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Takemura, Akihiro</creatorcontrib><creatorcontrib>Shoji, Saori</creatorcontrib><creatorcontrib>Ueda, Sinichi</creatorcontrib><creatorcontrib>Kurata, Yuichi</creatorcontrib><creatorcontrib>Kumano, Tomoyasu</creatorcontrib><creatorcontrib>Takamatsu, Shigeyuki</creatorcontrib><creatorcontrib>Suzuki, Masayuki</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Radiological physics and technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Takemura, Akihiro</au><au>Shoji, Saori</au><au>Ueda, Sinichi</au><au>Kurata, Yuichi</au><au>Kumano, Tomoyasu</au><au>Takamatsu, Shigeyuki</au><au>Suzuki, Masayuki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of daily setup errors on individual dose distribution in conventional radiotherapy: an initial study</atitle><jtitle>Radiological physics and technology</jtitle><stitle>Radiol Phys Technol</stitle><addtitle>Radiol Phys Technol</addtitle><date>2009-07-01</date><risdate>2009</risdate><volume>2</volume><issue>2</issue><spage>151</spage><epage>158</epage><pages>151-158</pages><issn>1865-0333</issn><eissn>1865-0341</eissn><abstract>Recent linear accelerators can perform cone-beam computed tomography to correct setup errors immediately before dose delivery. We calculated the dose distribution with setup errors acquired from cone-beam computed tomography to determine a more realistic and individual effect of setup errors. The differences in dose distribution were analyzed. The setup errors of three patients who were irradiated in the neck, esophagus, and pelvic area were obtained retrospectively. We found that the maximum dose variances for the three cases were 19.9–35.9%. The maximum dose variance points were relatively far from the isocenter. The volume of the 10% dose difference had widths of 1.3–1.85 cm around the beam edges. The V95 and mean doses at the clinical target volume were mostly unchanged. Doses around the beam edges were more varied than those around the isocenter for every case. The dose on the spinal cord located near the beam edges varied by 5–10% compared with the dose of the radiotherapy plan in two of the cases. We demonstrated the individual dose distributions of the cases affected by daily setup errors for all fractions.</abstract><cop>Tokyo</cop><pub>Springer Japan</pub><pmid>20821114</pmid><doi>10.1007/s12194-009-0059-0</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1865-0333
ispartof Radiological physics and technology, 2009-07, Vol.2 (2), p.151-158
issn 1865-0333
1865-0341
language eng
recordid cdi_proquest_miscellaneous_754022017
source MEDLINE; Springer Nature - Complete Springer Journals
subjects Aged
Cone-Beam Computed Tomography
Dose Fractionation
Female
Humans
Imaging
Imaging, Three-Dimensional
Male
Medical and Radiation Physics
Medical Errors
Medicine
Medicine & Public Health
Middle Aged
Neoplasms - diagnostic imaging
Neoplasms - radiotherapy
Nuclear Medicine
Radiology
Radiotherapy
Retrospective Studies
Time Factors
title Effect of daily setup errors on individual dose distribution in conventional radiotherapy: an initial study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T20%3A40%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20daily%20setup%20errors%20on%20individual%20dose%20distribution%20in%20conventional%20radiotherapy:%20an%20initial%20study&rft.jtitle=Radiological%20physics%20and%20technology&rft.au=Takemura,%20Akihiro&rft.date=2009-07-01&rft.volume=2&rft.issue=2&rft.spage=151&rft.epage=158&rft.pages=151-158&rft.issn=1865-0333&rft.eissn=1865-0341&rft_id=info:doi/10.1007/s12194-009-0059-0&rft_dat=%3Cproquest_cross%3E754022017%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=754022017&rft_id=info:pmid/20821114&rfr_iscdi=true