Effect of daily setup errors on individual dose distribution in conventional radiotherapy: an initial study
Recent linear accelerators can perform cone-beam computed tomography to correct setup errors immediately before dose delivery. We calculated the dose distribution with setup errors acquired from cone-beam computed tomography to determine a more realistic and individual effect of setup errors. The di...
Gespeichert in:
Veröffentlicht in: | Radiological physics and technology 2009-07, Vol.2 (2), p.151-158 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 158 |
---|---|
container_issue | 2 |
container_start_page | 151 |
container_title | Radiological physics and technology |
container_volume | 2 |
creator | Takemura, Akihiro Shoji, Saori Ueda, Sinichi Kurata, Yuichi Kumano, Tomoyasu Takamatsu, Shigeyuki Suzuki, Masayuki |
description | Recent linear accelerators can perform cone-beam computed tomography to correct setup errors immediately before dose delivery. We calculated the dose distribution with setup errors acquired from cone-beam computed tomography to determine a more realistic and individual effect of setup errors. The differences in dose distribution were analyzed. The setup errors of three patients who were irradiated in the neck, esophagus, and pelvic area were obtained retrospectively. We found that the maximum dose variances for the three cases were 19.9–35.9%. The maximum dose variance points were relatively far from the isocenter. The volume of the 10% dose difference had widths of 1.3–1.85 cm around the beam edges. The V95 and mean doses at the clinical target volume were mostly unchanged. Doses around the beam edges were more varied than those around the isocenter for every case. The dose on the spinal cord located near the beam edges varied by 5–10% compared with the dose of the radiotherapy plan in two of the cases. We demonstrated the individual dose distributions of the cases affected by daily setup errors for all fractions. |
doi_str_mv | 10.1007/s12194-009-0059-0 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_754022017</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>754022017</sourcerecordid><originalsourceid>FETCH-LOGICAL-c411t-548f2ae532cb7ac0e2c6cde8296e85168d4db6daf56feee35738f51948f60cdd3</originalsourceid><addsrcrecordid>eNp9kE9PwyAYh4nRuDn9AF4MN09VoKXtvBkz_yRLvOiZMHhRZlcq0CX79lI7d_QAvOT3vL_Dg9AlJTeUkOo2UEbnRUbIPB2eriM0pXXJM5IX9Pgw5_kEnYWwJqSkjLFTNGGkZpTSYoq-FsaAitgZrKVtdjhA7DsM3jsfsGuxbbXdWt3LBmsXAGsborerPtrfECvXbqEdfonwUlsXP8HLbneH5QDYaFMQYq935-jEyCbAxf6doffHxdvDc7Z8fXp5uF9mqqA0ZryoDZPAc6ZWlVQEmCqVhprNS6g5LWtd6FWppeGlAYCcV3lteBJRm5IorfMZuh57O---ewhRbGxQ0DSyBdcHUfGCMEZolUg6ksq7EDwY0Xm7kX4nKBGDYjEqFkmxGBQLknau9u39agP6sPHnNAFsBEKK2g_wYu16n_SEf1p_AAROiRY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>754022017</pqid></control><display><type>article</type><title>Effect of daily setup errors on individual dose distribution in conventional radiotherapy: an initial study</title><source>MEDLINE</source><source>Springer Nature - Complete Springer Journals</source><creator>Takemura, Akihiro ; Shoji, Saori ; Ueda, Sinichi ; Kurata, Yuichi ; Kumano, Tomoyasu ; Takamatsu, Shigeyuki ; Suzuki, Masayuki</creator><creatorcontrib>Takemura, Akihiro ; Shoji, Saori ; Ueda, Sinichi ; Kurata, Yuichi ; Kumano, Tomoyasu ; Takamatsu, Shigeyuki ; Suzuki, Masayuki</creatorcontrib><description>Recent linear accelerators can perform cone-beam computed tomography to correct setup errors immediately before dose delivery. We calculated the dose distribution with setup errors acquired from cone-beam computed tomography to determine a more realistic and individual effect of setup errors. The differences in dose distribution were analyzed. The setup errors of three patients who were irradiated in the neck, esophagus, and pelvic area were obtained retrospectively. We found that the maximum dose variances for the three cases were 19.9–35.9%. The maximum dose variance points were relatively far from the isocenter. The volume of the 10% dose difference had widths of 1.3–1.85 cm around the beam edges. The V95 and mean doses at the clinical target volume were mostly unchanged. Doses around the beam edges were more varied than those around the isocenter for every case. The dose on the spinal cord located near the beam edges varied by 5–10% compared with the dose of the radiotherapy plan in two of the cases. We demonstrated the individual dose distributions of the cases affected by daily setup errors for all fractions.</description><identifier>ISSN: 1865-0333</identifier><identifier>EISSN: 1865-0341</identifier><identifier>DOI: 10.1007/s12194-009-0059-0</identifier><identifier>PMID: 20821114</identifier><language>eng</language><publisher>Tokyo: Springer Japan</publisher><subject>Aged ; Cone-Beam Computed Tomography ; Dose Fractionation ; Female ; Humans ; Imaging ; Imaging, Three-Dimensional ; Male ; Medical and Radiation Physics ; Medical Errors ; Medicine ; Medicine & Public Health ; Middle Aged ; Neoplasms - diagnostic imaging ; Neoplasms - radiotherapy ; Nuclear Medicine ; Radiology ; Radiotherapy ; Retrospective Studies ; Time Factors</subject><ispartof>Radiological physics and technology, 2009-07, Vol.2 (2), p.151-158</ispartof><rights>Japanese Society of Radiological Technology and Japan Society of Medical Physics 2009</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c411t-548f2ae532cb7ac0e2c6cde8296e85168d4db6daf56feee35738f51948f60cdd3</citedby><cites>FETCH-LOGICAL-c411t-548f2ae532cb7ac0e2c6cde8296e85168d4db6daf56feee35738f51948f60cdd3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s12194-009-0059-0$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s12194-009-0059-0$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,41464,42533,51294</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20821114$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Takemura, Akihiro</creatorcontrib><creatorcontrib>Shoji, Saori</creatorcontrib><creatorcontrib>Ueda, Sinichi</creatorcontrib><creatorcontrib>Kurata, Yuichi</creatorcontrib><creatorcontrib>Kumano, Tomoyasu</creatorcontrib><creatorcontrib>Takamatsu, Shigeyuki</creatorcontrib><creatorcontrib>Suzuki, Masayuki</creatorcontrib><title>Effect of daily setup errors on individual dose distribution in conventional radiotherapy: an initial study</title><title>Radiological physics and technology</title><addtitle>Radiol Phys Technol</addtitle><addtitle>Radiol Phys Technol</addtitle><description>Recent linear accelerators can perform cone-beam computed tomography to correct setup errors immediately before dose delivery. We calculated the dose distribution with setup errors acquired from cone-beam computed tomography to determine a more realistic and individual effect of setup errors. The differences in dose distribution were analyzed. The setup errors of three patients who were irradiated in the neck, esophagus, and pelvic area were obtained retrospectively. We found that the maximum dose variances for the three cases were 19.9–35.9%. The maximum dose variance points were relatively far from the isocenter. The volume of the 10% dose difference had widths of 1.3–1.85 cm around the beam edges. The V95 and mean doses at the clinical target volume were mostly unchanged. Doses around the beam edges were more varied than those around the isocenter for every case. The dose on the spinal cord located near the beam edges varied by 5–10% compared with the dose of the radiotherapy plan in two of the cases. We demonstrated the individual dose distributions of the cases affected by daily setup errors for all fractions.</description><subject>Aged</subject><subject>Cone-Beam Computed Tomography</subject><subject>Dose Fractionation</subject><subject>Female</subject><subject>Humans</subject><subject>Imaging</subject><subject>Imaging, Three-Dimensional</subject><subject>Male</subject><subject>Medical and Radiation Physics</subject><subject>Medical Errors</subject><subject>Medicine</subject><subject>Medicine & Public Health</subject><subject>Middle Aged</subject><subject>Neoplasms - diagnostic imaging</subject><subject>Neoplasms - radiotherapy</subject><subject>Nuclear Medicine</subject><subject>Radiology</subject><subject>Radiotherapy</subject><subject>Retrospective Studies</subject><subject>Time Factors</subject><issn>1865-0333</issn><issn>1865-0341</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE9PwyAYh4nRuDn9AF4MN09VoKXtvBkz_yRLvOiZMHhRZlcq0CX79lI7d_QAvOT3vL_Dg9AlJTeUkOo2UEbnRUbIPB2eriM0pXXJM5IX9Pgw5_kEnYWwJqSkjLFTNGGkZpTSYoq-FsaAitgZrKVtdjhA7DsM3jsfsGuxbbXdWt3LBmsXAGsborerPtrfECvXbqEdfonwUlsXP8HLbneH5QDYaFMQYq935-jEyCbAxf6doffHxdvDc7Z8fXp5uF9mqqA0ZryoDZPAc6ZWlVQEmCqVhprNS6g5LWtd6FWppeGlAYCcV3lteBJRm5IorfMZuh57O---ewhRbGxQ0DSyBdcHUfGCMEZolUg6ksq7EDwY0Xm7kX4nKBGDYjEqFkmxGBQLknau9u39agP6sPHnNAFsBEKK2g_wYu16n_SEf1p_AAROiRY</recordid><startdate>20090701</startdate><enddate>20090701</enddate><creator>Takemura, Akihiro</creator><creator>Shoji, Saori</creator><creator>Ueda, Sinichi</creator><creator>Kurata, Yuichi</creator><creator>Kumano, Tomoyasu</creator><creator>Takamatsu, Shigeyuki</creator><creator>Suzuki, Masayuki</creator><general>Springer Japan</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20090701</creationdate><title>Effect of daily setup errors on individual dose distribution in conventional radiotherapy: an initial study</title><author>Takemura, Akihiro ; Shoji, Saori ; Ueda, Sinichi ; Kurata, Yuichi ; Kumano, Tomoyasu ; Takamatsu, Shigeyuki ; Suzuki, Masayuki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c411t-548f2ae532cb7ac0e2c6cde8296e85168d4db6daf56feee35738f51948f60cdd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Aged</topic><topic>Cone-Beam Computed Tomography</topic><topic>Dose Fractionation</topic><topic>Female</topic><topic>Humans</topic><topic>Imaging</topic><topic>Imaging, Three-Dimensional</topic><topic>Male</topic><topic>Medical and Radiation Physics</topic><topic>Medical Errors</topic><topic>Medicine</topic><topic>Medicine & Public Health</topic><topic>Middle Aged</topic><topic>Neoplasms - diagnostic imaging</topic><topic>Neoplasms - radiotherapy</topic><topic>Nuclear Medicine</topic><topic>Radiology</topic><topic>Radiotherapy</topic><topic>Retrospective Studies</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Takemura, Akihiro</creatorcontrib><creatorcontrib>Shoji, Saori</creatorcontrib><creatorcontrib>Ueda, Sinichi</creatorcontrib><creatorcontrib>Kurata, Yuichi</creatorcontrib><creatorcontrib>Kumano, Tomoyasu</creatorcontrib><creatorcontrib>Takamatsu, Shigeyuki</creatorcontrib><creatorcontrib>Suzuki, Masayuki</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Radiological physics and technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Takemura, Akihiro</au><au>Shoji, Saori</au><au>Ueda, Sinichi</au><au>Kurata, Yuichi</au><au>Kumano, Tomoyasu</au><au>Takamatsu, Shigeyuki</au><au>Suzuki, Masayuki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of daily setup errors on individual dose distribution in conventional radiotherapy: an initial study</atitle><jtitle>Radiological physics and technology</jtitle><stitle>Radiol Phys Technol</stitle><addtitle>Radiol Phys Technol</addtitle><date>2009-07-01</date><risdate>2009</risdate><volume>2</volume><issue>2</issue><spage>151</spage><epage>158</epage><pages>151-158</pages><issn>1865-0333</issn><eissn>1865-0341</eissn><abstract>Recent linear accelerators can perform cone-beam computed tomography to correct setup errors immediately before dose delivery. We calculated the dose distribution with setup errors acquired from cone-beam computed tomography to determine a more realistic and individual effect of setup errors. The differences in dose distribution were analyzed. The setup errors of three patients who were irradiated in the neck, esophagus, and pelvic area were obtained retrospectively. We found that the maximum dose variances for the three cases were 19.9–35.9%. The maximum dose variance points were relatively far from the isocenter. The volume of the 10% dose difference had widths of 1.3–1.85 cm around the beam edges. The V95 and mean doses at the clinical target volume were mostly unchanged. Doses around the beam edges were more varied than those around the isocenter for every case. The dose on the spinal cord located near the beam edges varied by 5–10% compared with the dose of the radiotherapy plan in two of the cases. We demonstrated the individual dose distributions of the cases affected by daily setup errors for all fractions.</abstract><cop>Tokyo</cop><pub>Springer Japan</pub><pmid>20821114</pmid><doi>10.1007/s12194-009-0059-0</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1865-0333 |
ispartof | Radiological physics and technology, 2009-07, Vol.2 (2), p.151-158 |
issn | 1865-0333 1865-0341 |
language | eng |
recordid | cdi_proquest_miscellaneous_754022017 |
source | MEDLINE; Springer Nature - Complete Springer Journals |
subjects | Aged Cone-Beam Computed Tomography Dose Fractionation Female Humans Imaging Imaging, Three-Dimensional Male Medical and Radiation Physics Medical Errors Medicine Medicine & Public Health Middle Aged Neoplasms - diagnostic imaging Neoplasms - radiotherapy Nuclear Medicine Radiology Radiotherapy Retrospective Studies Time Factors |
title | Effect of daily setup errors on individual dose distribution in conventional radiotherapy: an initial study |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T20%3A40%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20daily%20setup%20errors%20on%20individual%20dose%20distribution%20in%20conventional%20radiotherapy:%20an%20initial%20study&rft.jtitle=Radiological%20physics%20and%20technology&rft.au=Takemura,%20Akihiro&rft.date=2009-07-01&rft.volume=2&rft.issue=2&rft.spage=151&rft.epage=158&rft.pages=151-158&rft.issn=1865-0333&rft.eissn=1865-0341&rft_id=info:doi/10.1007/s12194-009-0059-0&rft_dat=%3Cproquest_cross%3E754022017%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=754022017&rft_id=info:pmid/20821114&rfr_iscdi=true |