A Starr-Edwards mitral prosthesis after 44 years of good performance
The Starr-Edwards caged-ball prosthesis has been widely used to replace cardiac valves. The Model 6120 mitral prosthesis was introduced on the market in 1965 to reduce the high incidence of ball variance and thromboembolism of the previous model. We report the case of a Starr-Edwards Model 6120 whic...
Gespeichert in:
Veröffentlicht in: | International journal of artificial organs 2010-06, Vol.33 (6), p.405-407 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 407 |
---|---|
container_issue | 6 |
container_start_page | 405 |
container_title | International journal of artificial organs |
container_volume | 33 |
creator | DE SANTO, Luca Salvatore DE FEO, Marisa DELLA CORTE, Alessandro CERASUOLO, Flavio SANTE, Pasquale TORELLA, Michele NAPPI, Gianantonio |
description | The Starr-Edwards caged-ball prosthesis has been widely used to replace cardiac valves. The Model 6120 mitral prosthesis was introduced on the market in 1965 to reduce the high incidence of ball variance and thromboembolism of the previous model. We report the case of a Starr-Edwards Model 6120 which had been in place for 44 years and was still well functioning with no apparent structural damage. |
doi_str_mv | 10.1177/039139881003300609 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_754014344</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>754014344</sourcerecordid><originalsourceid>FETCH-LOGICAL-c247t-da11031d4f6c1bfb1bff5a69220762c6759501fdff12532d85b545293ed27d703</originalsourceid><addsrcrecordid>eNplkD1PwzAQhi0EoqXwBxiQF8QUuPNnMlalfEiVGIA5cmIbgpKm2KlQ_z2uWmBgON3yvK_uHkLOEa4Rtb4BXiAv8hwBOAdQUByQMWomMgUCDsl4C2RbYkROYvwAQCWEPCYjBjkywdWY3E7p82BCyOb2ywQbadcMwbR0Ffo4vLvYRGr84AIVgm6cCZH2nr71vaUrF3wfOrOs3Sk58qaN7my_J-T1bv4ye8gWT_ePs-kiq5nQQ2YNInC0wqsaK1-l8dKogjHQitVKy0ICeus9MsmZzWUlhWQFd5Zpq4FPyNWuN133uXZxKLsm1q5tzdL161hqKQAFFyKRbEfW6Y8YnC9XoelM2JQI5VZe-V9eCl3s69dV5-xv5MdWAi73gIm1aX1Izzfxj-PAWTLMvwGEBXSi</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>754014344</pqid></control><display><type>article</type><title>A Starr-Edwards mitral prosthesis after 44 years of good performance</title><source>MEDLINE</source><source>SAGE Complete</source><creator>DE SANTO, Luca Salvatore ; DE FEO, Marisa ; DELLA CORTE, Alessandro ; CERASUOLO, Flavio ; SANTE, Pasquale ; TORELLA, Michele ; NAPPI, Gianantonio</creator><creatorcontrib>DE SANTO, Luca Salvatore ; DE FEO, Marisa ; DELLA CORTE, Alessandro ; CERASUOLO, Flavio ; SANTE, Pasquale ; TORELLA, Michele ; NAPPI, Gianantonio</creatorcontrib><description>The Starr-Edwards caged-ball prosthesis has been widely used to replace cardiac valves. The Model 6120 mitral prosthesis was introduced on the market in 1965 to reduce the high incidence of ball variance and thromboembolism of the previous model. We report the case of a Starr-Edwards Model 6120 which had been in place for 44 years and was still well functioning with no apparent structural damage.</description><identifier>ISSN: 0391-3988</identifier><identifier>EISSN: 1724-6040</identifier><identifier>DOI: 10.1177/039139881003300609</identifier><identifier>PMID: 20812436</identifier><language>eng</language><publisher>Milano: Wichtig</publisher><subject>Aged ; Biological and medical sciences ; Female ; Heart Valve Diseases - etiology ; Heart Valve Diseases - pathology ; Heart Valve Diseases - therapy ; Heart Valve Prosthesis ; Humans ; Medical sciences ; Mitral Valve ; Prosthesis Design ; Prosthesis Failure ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Surgery of the heart ; Time Factors</subject><ispartof>International journal of artificial organs, 2010-06, Vol.33 (6), p.405-407</ispartof><rights>2015 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c247t-da11031d4f6c1bfb1bff5a69220762c6759501fdff12532d85b545293ed27d703</citedby><cites>FETCH-LOGICAL-c247t-da11031d4f6c1bfb1bff5a69220762c6759501fdff12532d85b545293ed27d703</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,27907,27908</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=23032644$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20812436$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>DE SANTO, Luca Salvatore</creatorcontrib><creatorcontrib>DE FEO, Marisa</creatorcontrib><creatorcontrib>DELLA CORTE, Alessandro</creatorcontrib><creatorcontrib>CERASUOLO, Flavio</creatorcontrib><creatorcontrib>SANTE, Pasquale</creatorcontrib><creatorcontrib>TORELLA, Michele</creatorcontrib><creatorcontrib>NAPPI, Gianantonio</creatorcontrib><title>A Starr-Edwards mitral prosthesis after 44 years of good performance</title><title>International journal of artificial organs</title><addtitle>Int J Artif Organs</addtitle><description>The Starr-Edwards caged-ball prosthesis has been widely used to replace cardiac valves. The Model 6120 mitral prosthesis was introduced on the market in 1965 to reduce the high incidence of ball variance and thromboembolism of the previous model. We report the case of a Starr-Edwards Model 6120 which had been in place for 44 years and was still well functioning with no apparent structural damage.</description><subject>Aged</subject><subject>Biological and medical sciences</subject><subject>Female</subject><subject>Heart Valve Diseases - etiology</subject><subject>Heart Valve Diseases - pathology</subject><subject>Heart Valve Diseases - therapy</subject><subject>Heart Valve Prosthesis</subject><subject>Humans</subject><subject>Medical sciences</subject><subject>Mitral Valve</subject><subject>Prosthesis Design</subject><subject>Prosthesis Failure</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Surgery of the heart</subject><subject>Time Factors</subject><issn>0391-3988</issn><issn>1724-6040</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNplkD1PwzAQhi0EoqXwBxiQF8QUuPNnMlalfEiVGIA5cmIbgpKm2KlQ_z2uWmBgON3yvK_uHkLOEa4Rtb4BXiAv8hwBOAdQUByQMWomMgUCDsl4C2RbYkROYvwAQCWEPCYjBjkywdWY3E7p82BCyOb2ywQbadcMwbR0Ffo4vLvYRGr84AIVgm6cCZH2nr71vaUrF3wfOrOs3Sk58qaN7my_J-T1bv4ye8gWT_ePs-kiq5nQQ2YNInC0wqsaK1-l8dKogjHQitVKy0ICeus9MsmZzWUlhWQFd5Zpq4FPyNWuN133uXZxKLsm1q5tzdL161hqKQAFFyKRbEfW6Y8YnC9XoelM2JQI5VZe-V9eCl3s69dV5-xv5MdWAi73gIm1aX1Izzfxj-PAWTLMvwGEBXSi</recordid><startdate>201006</startdate><enddate>201006</enddate><creator>DE SANTO, Luca Salvatore</creator><creator>DE FEO, Marisa</creator><creator>DELLA CORTE, Alessandro</creator><creator>CERASUOLO, Flavio</creator><creator>SANTE, Pasquale</creator><creator>TORELLA, Michele</creator><creator>NAPPI, Gianantonio</creator><general>Wichtig</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201006</creationdate><title>A Starr-Edwards mitral prosthesis after 44 years of good performance</title><author>DE SANTO, Luca Salvatore ; DE FEO, Marisa ; DELLA CORTE, Alessandro ; CERASUOLO, Flavio ; SANTE, Pasquale ; TORELLA, Michele ; NAPPI, Gianantonio</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c247t-da11031d4f6c1bfb1bff5a69220762c6759501fdff12532d85b545293ed27d703</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Aged</topic><topic>Biological and medical sciences</topic><topic>Female</topic><topic>Heart Valve Diseases - etiology</topic><topic>Heart Valve Diseases - pathology</topic><topic>Heart Valve Diseases - therapy</topic><topic>Heart Valve Prosthesis</topic><topic>Humans</topic><topic>Medical sciences</topic><topic>Mitral Valve</topic><topic>Prosthesis Design</topic><topic>Prosthesis Failure</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Surgery of the heart</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>DE SANTO, Luca Salvatore</creatorcontrib><creatorcontrib>DE FEO, Marisa</creatorcontrib><creatorcontrib>DELLA CORTE, Alessandro</creatorcontrib><creatorcontrib>CERASUOLO, Flavio</creatorcontrib><creatorcontrib>SANTE, Pasquale</creatorcontrib><creatorcontrib>TORELLA, Michele</creatorcontrib><creatorcontrib>NAPPI, Gianantonio</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International journal of artificial organs</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>DE SANTO, Luca Salvatore</au><au>DE FEO, Marisa</au><au>DELLA CORTE, Alessandro</au><au>CERASUOLO, Flavio</au><au>SANTE, Pasquale</au><au>TORELLA, Michele</au><au>NAPPI, Gianantonio</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Starr-Edwards mitral prosthesis after 44 years of good performance</atitle><jtitle>International journal of artificial organs</jtitle><addtitle>Int J Artif Organs</addtitle><date>2010-06</date><risdate>2010</risdate><volume>33</volume><issue>6</issue><spage>405</spage><epage>407</epage><pages>405-407</pages><issn>0391-3988</issn><eissn>1724-6040</eissn><abstract>The Starr-Edwards caged-ball prosthesis has been widely used to replace cardiac valves. The Model 6120 mitral prosthesis was introduced on the market in 1965 to reduce the high incidence of ball variance and thromboembolism of the previous model. We report the case of a Starr-Edwards Model 6120 which had been in place for 44 years and was still well functioning with no apparent structural damage.</abstract><cop>Milano</cop><pub>Wichtig</pub><pmid>20812436</pmid><doi>10.1177/039139881003300609</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0391-3988 |
ispartof | International journal of artificial organs, 2010-06, Vol.33 (6), p.405-407 |
issn | 0391-3988 1724-6040 |
language | eng |
recordid | cdi_proquest_miscellaneous_754014344 |
source | MEDLINE; SAGE Complete |
subjects | Aged Biological and medical sciences Female Heart Valve Diseases - etiology Heart Valve Diseases - pathology Heart Valve Diseases - therapy Heart Valve Prosthesis Humans Medical sciences Mitral Valve Prosthesis Design Prosthesis Failure Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases Surgery of the heart Time Factors |
title | A Starr-Edwards mitral prosthesis after 44 years of good performance |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T16%3A19%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Starr-Edwards%20mitral%20prosthesis%20after%2044%20years%20of%20good%20performance&rft.jtitle=International%20journal%20of%20artificial%20organs&rft.au=DE%20SANTO,%20Luca%20Salvatore&rft.date=2010-06&rft.volume=33&rft.issue=6&rft.spage=405&rft.epage=407&rft.pages=405-407&rft.issn=0391-3988&rft.eissn=1724-6040&rft_id=info:doi/10.1177/039139881003300609&rft_dat=%3Cproquest_cross%3E754014344%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=754014344&rft_id=info:pmid/20812436&rfr_iscdi=true |