Isoelectric focusing and isoelectric points of bovine liver histones

A technique for isoelectric focusing of total histones in very narrow pH gradients is described. The isoelectric focusing was performed in 5% acrylamide gels at the pH range 9–11 in long quartz tubes (24 cm) in a nitrogen atmosphere. The total bovine liver histones separated into five main fractions...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical biochemistry 1980-05, Vol.104 (2), p.499-505
Hauptverfasser: Valkonen, Kaija H., Piha, R.S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 505
container_issue 2
container_start_page 499
container_title Analytical biochemistry
container_volume 104
creator Valkonen, Kaija H.
Piha, R.S.
description A technique for isoelectric focusing of total histones in very narrow pH gradients is described. The isoelectric focusing was performed in 5% acrylamide gels at the pH range 9–11 in long quartz tubes (24 cm) in a nitrogen atmosphere. The total bovine liver histones separated into five main fractions which were identified as H1, H3, H2B, H2A, and H4 histones, and their apparent isoelectric points were determined. The main fractions were further divided into several subfractions, the maximal number of bands being 12. The isoelectric point for H1 histone in 6.25 m urea solution in the presence of a nitrogen atmosphere was 8.90, and the corresponding values for H3, H2B, H2A, and H4 histones were 9.80, 9.90, 10.10, and 10.25, respectively. The focusing technique described here has a high resolution, reproducibility, and sensitivity. The technique can be used for preparative and quantitative analysis and for studies on specificity and developmental changes of histones.
doi_str_mv 10.1016/0003-2697(80)90107-4
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_75386210</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0003269780901074</els_id><sourcerecordid>75386210</sourcerecordid><originalsourceid>FETCH-LOGICAL-c357t-69069b1b4e47ffddf4a6ca76b1d8a04da563f1858305290ba3393b7bbf5d3feb3</originalsourceid><addsrcrecordid>eNp9kEtLAzEQx4MotVa_gcKeRA-rkyab3b0IUl-Fghc9hzwmGtluarJb8Nu7tUU8eRqY_2OYHyGnFK4oUHENACyfirq8qOCyBgplzvfImEItcmBQ75Pxr-WQHKX0AUApL8SIjErOh60Yk7t5Ctig6aI3mQumT759y1RrM_9HWAXfdikLLtNh7VvMGr_GmL371IUW0zE5cKpJeLKbE_L6cP8ye8oXz4_z2e0iN6wou1zUIGpNNUdeOmet40oYVQpNbaWAW1UI5mhVVAyKaQ1aMVYzXWrtCsscajYh59veVQyfPaZOLn0y2DSqxdAnWRasElMKg5FvjSaGlCI6uYp-qeKXpCA38OSGjNyQkRXIH3iSD7GzXX-vl2h_Qztag36z1XF4cu0xymQ8tgatjwMpaYP__8A3K8x-rw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>75386210</pqid></control><display><type>article</type><title>Isoelectric focusing and isoelectric points of bovine liver histones</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Valkonen, Kaija H. ; Piha, R.S.</creator><creatorcontrib>Valkonen, Kaija H. ; Piha, R.S.</creatorcontrib><description>A technique for isoelectric focusing of total histones in very narrow pH gradients is described. The isoelectric focusing was performed in 5% acrylamide gels at the pH range 9–11 in long quartz tubes (24 cm) in a nitrogen atmosphere. The total bovine liver histones separated into five main fractions which were identified as H1, H3, H2B, H2A, and H4 histones, and their apparent isoelectric points were determined. The main fractions were further divided into several subfractions, the maximal number of bands being 12. The isoelectric point for H1 histone in 6.25 m urea solution in the presence of a nitrogen atmosphere was 8.90, and the corresponding values for H3, H2B, H2A, and H4 histones were 9.80, 9.90, 10.10, and 10.25, respectively. The focusing technique described here has a high resolution, reproducibility, and sensitivity. The technique can be used for preparative and quantitative analysis and for studies on specificity and developmental changes of histones.</description><identifier>ISSN: 0003-2697</identifier><identifier>EISSN: 1096-0309</identifier><identifier>DOI: 10.1016/0003-2697(80)90107-4</identifier><identifier>PMID: 7446976</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Animals ; Cattle ; Cell Nucleus - analysis ; Electrophoresis, Polyacrylamide Gel ; Histones - isolation &amp; purification ; Hydrogen-Ion Concentration ; Isoelectric Focusing ; Isoelectric Point ; Liver - analysis</subject><ispartof>Analytical biochemistry, 1980-05, Vol.104 (2), p.499-505</ispartof><rights>1980</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c357t-69069b1b4e47ffddf4a6ca76b1d8a04da563f1858305290ba3393b7bbf5d3feb3</citedby><cites>FETCH-LOGICAL-c357t-69069b1b4e47ffddf4a6ca76b1d8a04da563f1858305290ba3393b7bbf5d3feb3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/0003269780901074$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7446976$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Valkonen, Kaija H.</creatorcontrib><creatorcontrib>Piha, R.S.</creatorcontrib><title>Isoelectric focusing and isoelectric points of bovine liver histones</title><title>Analytical biochemistry</title><addtitle>Anal Biochem</addtitle><description>A technique for isoelectric focusing of total histones in very narrow pH gradients is described. The isoelectric focusing was performed in 5% acrylamide gels at the pH range 9–11 in long quartz tubes (24 cm) in a nitrogen atmosphere. The total bovine liver histones separated into five main fractions which were identified as H1, H3, H2B, H2A, and H4 histones, and their apparent isoelectric points were determined. The main fractions were further divided into several subfractions, the maximal number of bands being 12. The isoelectric point for H1 histone in 6.25 m urea solution in the presence of a nitrogen atmosphere was 8.90, and the corresponding values for H3, H2B, H2A, and H4 histones were 9.80, 9.90, 10.10, and 10.25, respectively. The focusing technique described here has a high resolution, reproducibility, and sensitivity. The technique can be used for preparative and quantitative analysis and for studies on specificity and developmental changes of histones.</description><subject>Animals</subject><subject>Cattle</subject><subject>Cell Nucleus - analysis</subject><subject>Electrophoresis, Polyacrylamide Gel</subject><subject>Histones - isolation &amp; purification</subject><subject>Hydrogen-Ion Concentration</subject><subject>Isoelectric Focusing</subject><subject>Isoelectric Point</subject><subject>Liver - analysis</subject><issn>0003-2697</issn><issn>1096-0309</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1980</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kEtLAzEQx4MotVa_gcKeRA-rkyab3b0IUl-Fghc9hzwmGtluarJb8Nu7tUU8eRqY_2OYHyGnFK4oUHENACyfirq8qOCyBgplzvfImEItcmBQ75Pxr-WQHKX0AUApL8SIjErOh60Yk7t5Ctig6aI3mQumT759y1RrM_9HWAXfdikLLtNh7VvMGr_GmL371IUW0zE5cKpJeLKbE_L6cP8ye8oXz4_z2e0iN6wou1zUIGpNNUdeOmet40oYVQpNbaWAW1UI5mhVVAyKaQ1aMVYzXWrtCsscajYh59veVQyfPaZOLn0y2DSqxdAnWRasElMKg5FvjSaGlCI6uYp-qeKXpCA38OSGjNyQkRXIH3iSD7GzXX-vl2h_Qztag36z1XF4cu0xymQ8tgatjwMpaYP__8A3K8x-rw</recordid><startdate>19800515</startdate><enddate>19800515</enddate><creator>Valkonen, Kaija H.</creator><creator>Piha, R.S.</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19800515</creationdate><title>Isoelectric focusing and isoelectric points of bovine liver histones</title><author>Valkonen, Kaija H. ; Piha, R.S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c357t-69069b1b4e47ffddf4a6ca76b1d8a04da563f1858305290ba3393b7bbf5d3feb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1980</creationdate><topic>Animals</topic><topic>Cattle</topic><topic>Cell Nucleus - analysis</topic><topic>Electrophoresis, Polyacrylamide Gel</topic><topic>Histones - isolation &amp; purification</topic><topic>Hydrogen-Ion Concentration</topic><topic>Isoelectric Focusing</topic><topic>Isoelectric Point</topic><topic>Liver - analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Valkonen, Kaija H.</creatorcontrib><creatorcontrib>Piha, R.S.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical biochemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Valkonen, Kaija H.</au><au>Piha, R.S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Isoelectric focusing and isoelectric points of bovine liver histones</atitle><jtitle>Analytical biochemistry</jtitle><addtitle>Anal Biochem</addtitle><date>1980-05-15</date><risdate>1980</risdate><volume>104</volume><issue>2</issue><spage>499</spage><epage>505</epage><pages>499-505</pages><issn>0003-2697</issn><eissn>1096-0309</eissn><abstract>A technique for isoelectric focusing of total histones in very narrow pH gradients is described. The isoelectric focusing was performed in 5% acrylamide gels at the pH range 9–11 in long quartz tubes (24 cm) in a nitrogen atmosphere. The total bovine liver histones separated into five main fractions which were identified as H1, H3, H2B, H2A, and H4 histones, and their apparent isoelectric points were determined. The main fractions were further divided into several subfractions, the maximal number of bands being 12. The isoelectric point for H1 histone in 6.25 m urea solution in the presence of a nitrogen atmosphere was 8.90, and the corresponding values for H3, H2B, H2A, and H4 histones were 9.80, 9.90, 10.10, and 10.25, respectively. The focusing technique described here has a high resolution, reproducibility, and sensitivity. The technique can be used for preparative and quantitative analysis and for studies on specificity and developmental changes of histones.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>7446976</pmid><doi>10.1016/0003-2697(80)90107-4</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2697
ispartof Analytical biochemistry, 1980-05, Vol.104 (2), p.499-505
issn 0003-2697
1096-0309
language eng
recordid cdi_proquest_miscellaneous_75386210
source MEDLINE; Elsevier ScienceDirect Journals Complete
subjects Animals
Cattle
Cell Nucleus - analysis
Electrophoresis, Polyacrylamide Gel
Histones - isolation & purification
Hydrogen-Ion Concentration
Isoelectric Focusing
Isoelectric Point
Liver - analysis
title Isoelectric focusing and isoelectric points of bovine liver histones
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-01T09%3A27%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Isoelectric%20focusing%20and%20isoelectric%20points%20of%20bovine%20liver%20histones&rft.jtitle=Analytical%20biochemistry&rft.au=Valkonen,%20Kaija%20H.&rft.date=1980-05-15&rft.volume=104&rft.issue=2&rft.spage=499&rft.epage=505&rft.pages=499-505&rft.issn=0003-2697&rft.eissn=1096-0309&rft_id=info:doi/10.1016/0003-2697(80)90107-4&rft_dat=%3Cproquest_cross%3E75386210%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=75386210&rft_id=info:pmid/7446976&rft_els_id=0003269780901074&rfr_iscdi=true