Beam test of Shashlyk EM calorimeter prototypes readout by novel MAPD with super high linearity
The main properties of two different Shashlyk EM calorimeter modules readout by novel micropixel avalanche photodiodes (MAPD) with microwell structure and very high density of pixels were studied at the T9 CERN PS test-beam facility. A MAPD-3A with density of pixels 1.5×10 4 mm −2 and area 3×3 mm 2...
Gespeichert in:
Veröffentlicht in: | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2010-05, Vol.617 (1), p.78-80 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 80 |
---|---|
container_issue | 1 |
container_start_page | 78 |
container_title | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment |
container_volume | 617 |
creator | Anfimov, N. Chirikov-Zorin, I. Dovlatov, A. Gavrishchuk, O. Guskov, A. Khovanskiy, N. Krumshtein, Z. Leitner, R. Meshcheryakov, G. Nagaytsev, A. Olchevski, A. Rezinko, T. Sadovskiy, A. Sadygov, Z. Savin, I. Tchalyshev, V. Tyapkin, I. Yarygin, G. Zerrouk, F. |
description | The main properties of two different Shashlyk EM calorimeter modules readout by novel micropixel avalanche photodiodes (MAPD) with microwell structure and very high density of pixels were studied at the T9 CERN PS test-beam facility. A MAPD-3A with density of pixels 1.5×10
4
mm
−2 and area 3×3
mm
2 manufactured by Zecotek Company was used in our test. |
doi_str_mv | 10.1016/j.nima.2009.10.019 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_753645476</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S016890020901924X</els_id><sourcerecordid>753645476</sourcerecordid><originalsourceid>FETCH-LOGICAL-c332t-79a8532b6d3bcdaa3166c76904c87825f460d3ee5b089e5c942f1f270fe3d7573</originalsourceid><addsrcrecordid>eNp9kM1OwzAQhC0EEqXwApx845Ti2IkdS1wKlB-pFUjA2XKdDXFJ42K7RXl7XJUze1lp9M1qZxC6zMkkJzm_Xk16u9YTSohMwoTk8giN8krQTJaCH6NRgqpMEkJP0VkIK5JGimqE1C3oNY4QInYNfmt1aLvhC88W2OjOebuGCB5vvIsuDhsI2IOu3Tbi5YB7t4MOL6av9_jHxhaH7Saxrf1scWd70N7G4RydNLoLcPG3x-jjYfZ-95TNXx6f76bzzDBGYyakrkpGl7xmS1NrzXLOjeCSFKYSFS2bgpOaAZRLUkkojSxokzdUkAZYLUrBxujqcDe9-r1NcdTaBgNdp3tw26BEyXhRFoInkh5I410IHhq1STG1H1RO1L5MtVL7MtW-zL2Wykymm4MJUoadBa-CsdAbqK0HE1Xt7H_2X6Yefd0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>753645476</pqid></control><display><type>article</type><title>Beam test of Shashlyk EM calorimeter prototypes readout by novel MAPD with super high linearity</title><source>Elsevier ScienceDirect Journals</source><creator>Anfimov, N. ; Chirikov-Zorin, I. ; Dovlatov, A. ; Gavrishchuk, O. ; Guskov, A. ; Khovanskiy, N. ; Krumshtein, Z. ; Leitner, R. ; Meshcheryakov, G. ; Nagaytsev, A. ; Olchevski, A. ; Rezinko, T. ; Sadovskiy, A. ; Sadygov, Z. ; Savin, I. ; Tchalyshev, V. ; Tyapkin, I. ; Yarygin, G. ; Zerrouk, F.</creator><creatorcontrib>Anfimov, N. ; Chirikov-Zorin, I. ; Dovlatov, A. ; Gavrishchuk, O. ; Guskov, A. ; Khovanskiy, N. ; Krumshtein, Z. ; Leitner, R. ; Meshcheryakov, G. ; Nagaytsev, A. ; Olchevski, A. ; Rezinko, T. ; Sadovskiy, A. ; Sadygov, Z. ; Savin, I. ; Tchalyshev, V. ; Tyapkin, I. ; Yarygin, G. ; Zerrouk, F.</creatorcontrib><description>The main properties of two different Shashlyk EM calorimeter modules readout by novel micropixel avalanche photodiodes (MAPD) with microwell structure and very high density of pixels were studied at the T9 CERN PS test-beam facility. A MAPD-3A with density of pixels 1.5×10
4
mm
−2 and area 3×3
mm
2 manufactured by Zecotek Company was used in our test.</description><identifier>ISSN: 0168-9002</identifier><identifier>EISSN: 1872-9576</identifier><identifier>DOI: 10.1016/j.nima.2009.10.019</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Accelerators ; Beam ; Beams (radiation) ; Calorimeter ; CERN ; Density ; Gain ; High density ; Linearity ; MAPD ; Photodiodes ; Pixels ; PMT ; Polystyrene resins ; Resolution ; Scintillator</subject><ispartof>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 2010-05, Vol.617 (1), p.78-80</ispartof><rights>2009 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c332t-79a8532b6d3bcdaa3166c76904c87825f460d3ee5b089e5c942f1f270fe3d7573</citedby><cites>FETCH-LOGICAL-c332t-79a8532b6d3bcdaa3166c76904c87825f460d3ee5b089e5c942f1f270fe3d7573</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S016890020901924X$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Anfimov, N.</creatorcontrib><creatorcontrib>Chirikov-Zorin, I.</creatorcontrib><creatorcontrib>Dovlatov, A.</creatorcontrib><creatorcontrib>Gavrishchuk, O.</creatorcontrib><creatorcontrib>Guskov, A.</creatorcontrib><creatorcontrib>Khovanskiy, N.</creatorcontrib><creatorcontrib>Krumshtein, Z.</creatorcontrib><creatorcontrib>Leitner, R.</creatorcontrib><creatorcontrib>Meshcheryakov, G.</creatorcontrib><creatorcontrib>Nagaytsev, A.</creatorcontrib><creatorcontrib>Olchevski, A.</creatorcontrib><creatorcontrib>Rezinko, T.</creatorcontrib><creatorcontrib>Sadovskiy, A.</creatorcontrib><creatorcontrib>Sadygov, Z.</creatorcontrib><creatorcontrib>Savin, I.</creatorcontrib><creatorcontrib>Tchalyshev, V.</creatorcontrib><creatorcontrib>Tyapkin, I.</creatorcontrib><creatorcontrib>Yarygin, G.</creatorcontrib><creatorcontrib>Zerrouk, F.</creatorcontrib><title>Beam test of Shashlyk EM calorimeter prototypes readout by novel MAPD with super high linearity</title><title>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment</title><description>The main properties of two different Shashlyk EM calorimeter modules readout by novel micropixel avalanche photodiodes (MAPD) with microwell structure and very high density of pixels were studied at the T9 CERN PS test-beam facility. A MAPD-3A with density of pixels 1.5×10
4
mm
−2 and area 3×3
mm
2 manufactured by Zecotek Company was used in our test.</description><subject>Accelerators</subject><subject>Beam</subject><subject>Beams (radiation)</subject><subject>Calorimeter</subject><subject>CERN</subject><subject>Density</subject><subject>Gain</subject><subject>High density</subject><subject>Linearity</subject><subject>MAPD</subject><subject>Photodiodes</subject><subject>Pixels</subject><subject>PMT</subject><subject>Polystyrene resins</subject><subject>Resolution</subject><subject>Scintillator</subject><issn>0168-9002</issn><issn>1872-9576</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNp9kM1OwzAQhC0EEqXwApx845Ti2IkdS1wKlB-pFUjA2XKdDXFJ42K7RXl7XJUze1lp9M1qZxC6zMkkJzm_Xk16u9YTSohMwoTk8giN8krQTJaCH6NRgqpMEkJP0VkIK5JGimqE1C3oNY4QInYNfmt1aLvhC88W2OjOebuGCB5vvIsuDhsI2IOu3Tbi5YB7t4MOL6av9_jHxhaH7Saxrf1scWd70N7G4RydNLoLcPG3x-jjYfZ-95TNXx6f76bzzDBGYyakrkpGl7xmS1NrzXLOjeCSFKYSFS2bgpOaAZRLUkkojSxokzdUkAZYLUrBxujqcDe9-r1NcdTaBgNdp3tw26BEyXhRFoInkh5I410IHhq1STG1H1RO1L5MtVL7MtW-zL2Wykymm4MJUoadBa-CsdAbqK0HE1Xt7H_2X6Yefd0</recordid><startdate>20100511</startdate><enddate>20100511</enddate><creator>Anfimov, N.</creator><creator>Chirikov-Zorin, I.</creator><creator>Dovlatov, A.</creator><creator>Gavrishchuk, O.</creator><creator>Guskov, A.</creator><creator>Khovanskiy, N.</creator><creator>Krumshtein, Z.</creator><creator>Leitner, R.</creator><creator>Meshcheryakov, G.</creator><creator>Nagaytsev, A.</creator><creator>Olchevski, A.</creator><creator>Rezinko, T.</creator><creator>Sadovskiy, A.</creator><creator>Sadygov, Z.</creator><creator>Savin, I.</creator><creator>Tchalyshev, V.</creator><creator>Tyapkin, I.</creator><creator>Yarygin, G.</creator><creator>Zerrouk, F.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20100511</creationdate><title>Beam test of Shashlyk EM calorimeter prototypes readout by novel MAPD with super high linearity</title><author>Anfimov, N. ; Chirikov-Zorin, I. ; Dovlatov, A. ; Gavrishchuk, O. ; Guskov, A. ; Khovanskiy, N. ; Krumshtein, Z. ; Leitner, R. ; Meshcheryakov, G. ; Nagaytsev, A. ; Olchevski, A. ; Rezinko, T. ; Sadovskiy, A. ; Sadygov, Z. ; Savin, I. ; Tchalyshev, V. ; Tyapkin, I. ; Yarygin, G. ; Zerrouk, F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c332t-79a8532b6d3bcdaa3166c76904c87825f460d3ee5b089e5c942f1f270fe3d7573</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Accelerators</topic><topic>Beam</topic><topic>Beams (radiation)</topic><topic>Calorimeter</topic><topic>CERN</topic><topic>Density</topic><topic>Gain</topic><topic>High density</topic><topic>Linearity</topic><topic>MAPD</topic><topic>Photodiodes</topic><topic>Pixels</topic><topic>PMT</topic><topic>Polystyrene resins</topic><topic>Resolution</topic><topic>Scintillator</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Anfimov, N.</creatorcontrib><creatorcontrib>Chirikov-Zorin, I.</creatorcontrib><creatorcontrib>Dovlatov, A.</creatorcontrib><creatorcontrib>Gavrishchuk, O.</creatorcontrib><creatorcontrib>Guskov, A.</creatorcontrib><creatorcontrib>Khovanskiy, N.</creatorcontrib><creatorcontrib>Krumshtein, Z.</creatorcontrib><creatorcontrib>Leitner, R.</creatorcontrib><creatorcontrib>Meshcheryakov, G.</creatorcontrib><creatorcontrib>Nagaytsev, A.</creatorcontrib><creatorcontrib>Olchevski, A.</creatorcontrib><creatorcontrib>Rezinko, T.</creatorcontrib><creatorcontrib>Sadovskiy, A.</creatorcontrib><creatorcontrib>Sadygov, Z.</creatorcontrib><creatorcontrib>Savin, I.</creatorcontrib><creatorcontrib>Tchalyshev, V.</creatorcontrib><creatorcontrib>Tyapkin, I.</creatorcontrib><creatorcontrib>Yarygin, G.</creatorcontrib><creatorcontrib>Zerrouk, F.</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Anfimov, N.</au><au>Chirikov-Zorin, I.</au><au>Dovlatov, A.</au><au>Gavrishchuk, O.</au><au>Guskov, A.</au><au>Khovanskiy, N.</au><au>Krumshtein, Z.</au><au>Leitner, R.</au><au>Meshcheryakov, G.</au><au>Nagaytsev, A.</au><au>Olchevski, A.</au><au>Rezinko, T.</au><au>Sadovskiy, A.</au><au>Sadygov, Z.</au><au>Savin, I.</au><au>Tchalyshev, V.</au><au>Tyapkin, I.</au><au>Yarygin, G.</au><au>Zerrouk, F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Beam test of Shashlyk EM calorimeter prototypes readout by novel MAPD with super high linearity</atitle><jtitle>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment</jtitle><date>2010-05-11</date><risdate>2010</risdate><volume>617</volume><issue>1</issue><spage>78</spage><epage>80</epage><pages>78-80</pages><issn>0168-9002</issn><eissn>1872-9576</eissn><abstract>The main properties of two different Shashlyk EM calorimeter modules readout by novel micropixel avalanche photodiodes (MAPD) with microwell structure and very high density of pixels were studied at the T9 CERN PS test-beam facility. A MAPD-3A with density of pixels 1.5×10
4
mm
−2 and area 3×3
mm
2 manufactured by Zecotek Company was used in our test.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.nima.2009.10.019</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0168-9002 |
ispartof | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 2010-05, Vol.617 (1), p.78-80 |
issn | 0168-9002 1872-9576 |
language | eng |
recordid | cdi_proquest_miscellaneous_753645476 |
source | Elsevier ScienceDirect Journals |
subjects | Accelerators Beam Beams (radiation) Calorimeter CERN Density Gain High density Linearity MAPD Photodiodes Pixels PMT Polystyrene resins Resolution Scintillator |
title | Beam test of Shashlyk EM calorimeter prototypes readout by novel MAPD with super high linearity |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T05%3A35%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Beam%20test%20of%20Shashlyk%20EM%20calorimeter%20prototypes%20readout%20by%20novel%20MAPD%20with%20super%20high%20linearity&rft.jtitle=Nuclear%20instruments%20&%20methods%20in%20physics%20research.%20Section%20A,%20Accelerators,%20spectrometers,%20detectors%20and%20associated%20equipment&rft.au=Anfimov,%20N.&rft.date=2010-05-11&rft.volume=617&rft.issue=1&rft.spage=78&rft.epage=80&rft.pages=78-80&rft.issn=0168-9002&rft.eissn=1872-9576&rft_id=info:doi/10.1016/j.nima.2009.10.019&rft_dat=%3Cproquest_cross%3E753645476%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=753645476&rft_id=info:pmid/&rft_els_id=S016890020901924X&rfr_iscdi=true |