Temperature dependence of the chromatographic assay of hemoglobin A1 and application of a temperature controlled assay to clinical evaluation of diabetic control

We investigated the temperature dependence of the cation-exchange chromatographic properties of hemoglobin A1 using the "Fast Hemoglobins Test System" obtained from Isolab, Inc., Akron, OH, U.S.A. and a temperature control chamber constructed in our laboratory. Six patient samples, two eac...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinica chimica acta 1980-07, Vol.104 (3), p.319-328
Hauptverfasser: Johnson, M W, Dobrea, G M, Bendezu, R, Wieland, R G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 328
container_issue 3
container_start_page 319
container_title Clinica chimica acta
container_volume 104
creator Johnson, M W
Dobrea, G M
Bendezu, R
Wieland, R G
description We investigated the temperature dependence of the cation-exchange chromatographic properties of hemoglobin A1 using the "Fast Hemoglobins Test System" obtained from Isolab, Inc., Akron, OH, U.S.A. and a temperature control chamber constructed in our laboratory. Six patient samples, two each from the "normal" range (5--8.5%, "transitional" range (8.5--12.0%) and "uncontrolled diabetic" range (12--20%) described by Isolab (as measured at 24 degrees C) were collected, hemolyzed and assayed according to product insert instructions. Each sample was assayed in triplicate in three separate runs at 20 degrees C, 22 degrees C, 24 degrees C, 26 degrees C and 28 degrees C in the temperature controlled (+/- 0.25 degrees C) chamber. Resultant mean increases in assay results of 0.8, 1.1 and 1.6% hemoglobin A1 per 2 degrees C increase in temperature for the three ranges respectively, indicate that the temperature dependence of the microcolumn assay for hemoglobin A1 is at least partially a function of the relative percentage of glycosylated hemoglobin in the sample. By controlling assay temperature we have reduced interassay variation throughout all concentration ranges by more than one-half to less than 5%. We applied this temperature controlled assay to measurement of hemoglobin A1 levels in 33 non-diabetic subjects and to the screening of hemoglobin A1 levels in 77 diabetic patients regularly attending the diabetic-endocrine outpatient clinic of this hospital. No non-diabetic subject had a HbA1 level above 8.5% and of the diabetic patients, 26% fell within the "normal" range, 43% within the "transitional" range and 31% within the "uncontrolled diabetic" range.
doi_str_mv 10.1016/0009-8981(80)90389-7
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_75162664</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>75162664</sourcerecordid><originalsourceid>FETCH-LOGICAL-c302t-472869a7215c09018c976af4ceb3ac716581845066b143e77ec143f75c91f5033</originalsourceid><addsrcrecordid>eNpNkU1LxDAQhnNQdP34Bwo5iR6qybZN0uOy-AULXvQcpunUraRNTVLBn-M_tXXL4mmYmfd5B-Yl5IKzW864uGOMFYkqFL9W7KZgqSoSeUAW-_ExOQnhY2wzJvgROZKjgmd8QX5ese3RQxw80gp77CrsDFJX07hFarbetRDdu4d-2xgKIcD3tNxi696tK5uOrjiFrqLQ97YxEBvXTQKg8Z-zcV30zlqsZovoqLFNNwKW4hfYYQ9WDZQYx1szc0YOa7ABz-d6St4e7l_XT8nm5fF5vdokJmXLmGRyqUQBcslzwwrGlSmkgDozWKZgJBe54irLmRAlz1KUEs1Ya5mbgtc5S9NTcrXz7b37HDBE3TbBoLXQoRuCljkXSyGyUZjthMa7EDzWuvdNC_5bc6anNPT0dj29XSum_9LQcsQuZ_-hbLHaQ3MU6S8zDYod</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>75162664</pqid></control><display><type>article</type><title>Temperature dependence of the chromatographic assay of hemoglobin A1 and application of a temperature controlled assay to clinical evaluation of diabetic control</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Johnson, M W ; Dobrea, G M ; Bendezu, R ; Wieland, R G</creator><creatorcontrib>Johnson, M W ; Dobrea, G M ; Bendezu, R ; Wieland, R G</creatorcontrib><description>We investigated the temperature dependence of the cation-exchange chromatographic properties of hemoglobin A1 using the "Fast Hemoglobins Test System" obtained from Isolab, Inc., Akron, OH, U.S.A. and a temperature control chamber constructed in our laboratory. Six patient samples, two each from the "normal" range (5--8.5%, "transitional" range (8.5--12.0%) and "uncontrolled diabetic" range (12--20%) described by Isolab (as measured at 24 degrees C) were collected, hemolyzed and assayed according to product insert instructions. Each sample was assayed in triplicate in three separate runs at 20 degrees C, 22 degrees C, 24 degrees C, 26 degrees C and 28 degrees C in the temperature controlled (+/- 0.25 degrees C) chamber. Resultant mean increases in assay results of 0.8, 1.1 and 1.6% hemoglobin A1 per 2 degrees C increase in temperature for the three ranges respectively, indicate that the temperature dependence of the microcolumn assay for hemoglobin A1 is at least partially a function of the relative percentage of glycosylated hemoglobin in the sample. By controlling assay temperature we have reduced interassay variation throughout all concentration ranges by more than one-half to less than 5%. We applied this temperature controlled assay to measurement of hemoglobin A1 levels in 33 non-diabetic subjects and to the screening of hemoglobin A1 levels in 77 diabetic patients regularly attending the diabetic-endocrine outpatient clinic of this hospital. No non-diabetic subject had a HbA1 level above 8.5% and of the diabetic patients, 26% fell within the "normal" range, 43% within the "transitional" range and 31% within the "uncontrolled diabetic" range.</description><identifier>ISSN: 0009-8981</identifier><identifier>DOI: 10.1016/0009-8981(80)90389-7</identifier><identifier>PMID: 7389141</identifier><language>eng</language><publisher>Netherlands</publisher><subject>Adolescent ; Adult ; Aged ; Blood Glucose - metabolism ; Chromatography, Ion Exchange - methods ; Diabetes Mellitus - metabolism ; Diabetes Mellitus - therapy ; Hemoglobin A - analysis ; Humans ; Middle Aged ; Temperature</subject><ispartof>Clinica chimica acta, 1980-07, Vol.104 (3), p.319-328</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c302t-472869a7215c09018c976af4ceb3ac716581845066b143e77ec143f75c91f5033</citedby><cites>FETCH-LOGICAL-c302t-472869a7215c09018c976af4ceb3ac716581845066b143e77ec143f75c91f5033</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7389141$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Johnson, M W</creatorcontrib><creatorcontrib>Dobrea, G M</creatorcontrib><creatorcontrib>Bendezu, R</creatorcontrib><creatorcontrib>Wieland, R G</creatorcontrib><title>Temperature dependence of the chromatographic assay of hemoglobin A1 and application of a temperature controlled assay to clinical evaluation of diabetic control</title><title>Clinica chimica acta</title><addtitle>Clin Chim Acta</addtitle><description>We investigated the temperature dependence of the cation-exchange chromatographic properties of hemoglobin A1 using the "Fast Hemoglobins Test System" obtained from Isolab, Inc., Akron, OH, U.S.A. and a temperature control chamber constructed in our laboratory. Six patient samples, two each from the "normal" range (5--8.5%, "transitional" range (8.5--12.0%) and "uncontrolled diabetic" range (12--20%) described by Isolab (as measured at 24 degrees C) were collected, hemolyzed and assayed according to product insert instructions. Each sample was assayed in triplicate in three separate runs at 20 degrees C, 22 degrees C, 24 degrees C, 26 degrees C and 28 degrees C in the temperature controlled (+/- 0.25 degrees C) chamber. Resultant mean increases in assay results of 0.8, 1.1 and 1.6% hemoglobin A1 per 2 degrees C increase in temperature for the three ranges respectively, indicate that the temperature dependence of the microcolumn assay for hemoglobin A1 is at least partially a function of the relative percentage of glycosylated hemoglobin in the sample. By controlling assay temperature we have reduced interassay variation throughout all concentration ranges by more than one-half to less than 5%. We applied this temperature controlled assay to measurement of hemoglobin A1 levels in 33 non-diabetic subjects and to the screening of hemoglobin A1 levels in 77 diabetic patients regularly attending the diabetic-endocrine outpatient clinic of this hospital. No non-diabetic subject had a HbA1 level above 8.5% and of the diabetic patients, 26% fell within the "normal" range, 43% within the "transitional" range and 31% within the "uncontrolled diabetic" range.</description><subject>Adolescent</subject><subject>Adult</subject><subject>Aged</subject><subject>Blood Glucose - metabolism</subject><subject>Chromatography, Ion Exchange - methods</subject><subject>Diabetes Mellitus - metabolism</subject><subject>Diabetes Mellitus - therapy</subject><subject>Hemoglobin A - analysis</subject><subject>Humans</subject><subject>Middle Aged</subject><subject>Temperature</subject><issn>0009-8981</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1980</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNkU1LxDAQhnNQdP34Bwo5iR6qybZN0uOy-AULXvQcpunUraRNTVLBn-M_tXXL4mmYmfd5B-Yl5IKzW864uGOMFYkqFL9W7KZgqSoSeUAW-_ExOQnhY2wzJvgROZKjgmd8QX5ese3RQxw80gp77CrsDFJX07hFarbetRDdu4d-2xgKIcD3tNxi696tK5uOrjiFrqLQ97YxEBvXTQKg8Z-zcV30zlqsZovoqLFNNwKW4hfYYQ9WDZQYx1szc0YOa7ABz-d6St4e7l_XT8nm5fF5vdokJmXLmGRyqUQBcslzwwrGlSmkgDozWKZgJBe54irLmRAlz1KUEs1Ya5mbgtc5S9NTcrXz7b37HDBE3TbBoLXQoRuCljkXSyGyUZjthMa7EDzWuvdNC_5bc6anNPT0dj29XSum_9LQcsQuZ_-hbLHaQ3MU6S8zDYod</recordid><startdate>19800701</startdate><enddate>19800701</enddate><creator>Johnson, M W</creator><creator>Dobrea, G M</creator><creator>Bendezu, R</creator><creator>Wieland, R G</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19800701</creationdate><title>Temperature dependence of the chromatographic assay of hemoglobin A1 and application of a temperature controlled assay to clinical evaluation of diabetic control</title><author>Johnson, M W ; Dobrea, G M ; Bendezu, R ; Wieland, R G</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c302t-472869a7215c09018c976af4ceb3ac716581845066b143e77ec143f75c91f5033</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1980</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>Aged</topic><topic>Blood Glucose - metabolism</topic><topic>Chromatography, Ion Exchange - methods</topic><topic>Diabetes Mellitus - metabolism</topic><topic>Diabetes Mellitus - therapy</topic><topic>Hemoglobin A - analysis</topic><topic>Humans</topic><topic>Middle Aged</topic><topic>Temperature</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Johnson, M W</creatorcontrib><creatorcontrib>Dobrea, G M</creatorcontrib><creatorcontrib>Bendezu, R</creatorcontrib><creatorcontrib>Wieland, R G</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Clinica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Johnson, M W</au><au>Dobrea, G M</au><au>Bendezu, R</au><au>Wieland, R G</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Temperature dependence of the chromatographic assay of hemoglobin A1 and application of a temperature controlled assay to clinical evaluation of diabetic control</atitle><jtitle>Clinica chimica acta</jtitle><addtitle>Clin Chim Acta</addtitle><date>1980-07-01</date><risdate>1980</risdate><volume>104</volume><issue>3</issue><spage>319</spage><epage>328</epage><pages>319-328</pages><issn>0009-8981</issn><abstract>We investigated the temperature dependence of the cation-exchange chromatographic properties of hemoglobin A1 using the "Fast Hemoglobins Test System" obtained from Isolab, Inc., Akron, OH, U.S.A. and a temperature control chamber constructed in our laboratory. Six patient samples, two each from the "normal" range (5--8.5%, "transitional" range (8.5--12.0%) and "uncontrolled diabetic" range (12--20%) described by Isolab (as measured at 24 degrees C) were collected, hemolyzed and assayed according to product insert instructions. Each sample was assayed in triplicate in three separate runs at 20 degrees C, 22 degrees C, 24 degrees C, 26 degrees C and 28 degrees C in the temperature controlled (+/- 0.25 degrees C) chamber. Resultant mean increases in assay results of 0.8, 1.1 and 1.6% hemoglobin A1 per 2 degrees C increase in temperature for the three ranges respectively, indicate that the temperature dependence of the microcolumn assay for hemoglobin A1 is at least partially a function of the relative percentage of glycosylated hemoglobin in the sample. By controlling assay temperature we have reduced interassay variation throughout all concentration ranges by more than one-half to less than 5%. We applied this temperature controlled assay to measurement of hemoglobin A1 levels in 33 non-diabetic subjects and to the screening of hemoglobin A1 levels in 77 diabetic patients regularly attending the diabetic-endocrine outpatient clinic of this hospital. No non-diabetic subject had a HbA1 level above 8.5% and of the diabetic patients, 26% fell within the "normal" range, 43% within the "transitional" range and 31% within the "uncontrolled diabetic" range.</abstract><cop>Netherlands</cop><pmid>7389141</pmid><doi>10.1016/0009-8981(80)90389-7</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0009-8981
ispartof Clinica chimica acta, 1980-07, Vol.104 (3), p.319-328
issn 0009-8981
language eng
recordid cdi_proquest_miscellaneous_75162664
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects Adolescent
Adult
Aged
Blood Glucose - metabolism
Chromatography, Ion Exchange - methods
Diabetes Mellitus - metabolism
Diabetes Mellitus - therapy
Hemoglobin A - analysis
Humans
Middle Aged
Temperature
title Temperature dependence of the chromatographic assay of hemoglobin A1 and application of a temperature controlled assay to clinical evaluation of diabetic control
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T03%3A19%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Temperature%20dependence%20of%20the%20chromatographic%20assay%20of%20hemoglobin%20A1%20and%20application%20of%20a%20temperature%20controlled%20assay%20to%20clinical%20evaluation%20of%20diabetic%20control&rft.jtitle=Clinica%20chimica%20acta&rft.au=Johnson,%20M%20W&rft.date=1980-07-01&rft.volume=104&rft.issue=3&rft.spage=319&rft.epage=328&rft.pages=319-328&rft.issn=0009-8981&rft_id=info:doi/10.1016/0009-8981(80)90389-7&rft_dat=%3Cproquest_cross%3E75162664%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=75162664&rft_id=info:pmid/7389141&rfr_iscdi=true