Precise control over the oxygen conditions within the Boyden chamber using a microfabricated insert

Cell migration is a hallmark of cancer cell metastasis and is highly correlated with hypoxia in tumors. The Boyden chamber is a porous membrane-based migration platform that has seen a great deal of use for both in vitro migration and invasion assays due to its adaptability to common culture vessels...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Lab on a chip 2010-01, Vol.10 (18), p.2366-2373
Hauptverfasser: Oppegard, Shawn C, Blake, Alexander J, Williams, Justin C, Eddington, David T
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2373
container_issue 18
container_start_page 2366
container_title Lab on a chip
container_volume 10
creator Oppegard, Shawn C
Blake, Alexander J
Williams, Justin C
Eddington, David T
description Cell migration is a hallmark of cancer cell metastasis and is highly correlated with hypoxia in tumors. The Boyden chamber is a porous membrane-based migration platform that has seen a great deal of use for both in vitro migration and invasion assays due to its adaptability to common culture vessels and relative ease of use. The hypoxic chamber is a current tool that can be implemented to investigate the cellular response to oxygen paradigms. Unfortunately, this method lacks the spatial and temporal precision to accurately model a number of physiological phenomena. In this article, we present a newly developed microfabricated polydimethylsiloxane (PDMS) device that easily adapts to the Boyden chamber, and provides more control over the oxygenation conditions exposed to cells. The device equilibrates to 1% oxygen in about 20 min, thus demonstrating the capabilities of a system for researchers to establish both short-term continuous and intermittent hypoxia regimes. A Parylene-C thin-film coating was used to prevent ambient air penetration through the bulk PDMS and was found to yield improved equilibration times and end-point concentrations. MDA-MD-231 cells, an invasive breast cancer line, were used as a model cell type to demonstrate the effect of oxygen concentration on cell migration through the Boyden chamber porous membrane. Continuous hypoxia downregulated migration of cells relative to the normoxic control, as did an intermittent hypoxia regime (IH) cycling between 0% and 21% oxygen (0-21% IH). However, cells exposed to 5-21% IH exhibited increased migration compared to the other conditions, as well as relative to the normoxic control. The results presented here show the device can be utilized for experiments implementing the Boyden chamber for in vitro hypoxic studies, allowing experiments to be conducted faster and with more precision than currently possible.
doi_str_mv 10.1039/c004856a
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_748987840</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>748987840</sourcerecordid><originalsourceid>FETCH-LOGICAL-c381t-8f82a4430a90b2b4168509a194c589d967611231e17cbf48db85310822d802593</originalsourceid><addsrcrecordid>eNp9kEtPwzAQhC0EoqUg8QuQb3AJrB9J7CNUvKRKcIBz5DhOa5TExXaA_ntSaMuN0652Ps1qBqFTApcEmLzSAFykmdpDY8JzlgARcn-3y3yEjkJ4AyApz8QhGlHIhBQZHSP97I22wWDtuuhdg92H8TguDHZfq7np1vfKRuu6gD9tXNjuR7xxq2otLlRbDnwfbDfHCrdWe1er0lutoqmw7YLx8Rgd1KoJ5mQzJ-j17vZl-pDMnu4fp9ezRDNBYiJqQRXnDJSEkpacZCIFqYjkOhWyklmeEUIZMSTXZc1FVYqUERCUVgJoKtkEnf_6Lr17702IRWuDNk2jOuP6UOR8CJ0LDgN58S9JaDZ8A8nyP3RIFoI3dbH0tlV-VRAo1uUX2_IH9Gzj2petqXbgtm32DR5bffs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1266760937</pqid></control><display><type>article</type><title>Precise control over the oxygen conditions within the Boyden chamber using a microfabricated insert</title><source>MEDLINE</source><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Oppegard, Shawn C ; Blake, Alexander J ; Williams, Justin C ; Eddington, David T</creator><creatorcontrib>Oppegard, Shawn C ; Blake, Alexander J ; Williams, Justin C ; Eddington, David T</creatorcontrib><description>Cell migration is a hallmark of cancer cell metastasis and is highly correlated with hypoxia in tumors. The Boyden chamber is a porous membrane-based migration platform that has seen a great deal of use for both in vitro migration and invasion assays due to its adaptability to common culture vessels and relative ease of use. The hypoxic chamber is a current tool that can be implemented to investigate the cellular response to oxygen paradigms. Unfortunately, this method lacks the spatial and temporal precision to accurately model a number of physiological phenomena. In this article, we present a newly developed microfabricated polydimethylsiloxane (PDMS) device that easily adapts to the Boyden chamber, and provides more control over the oxygenation conditions exposed to cells. The device equilibrates to 1% oxygen in about 20 min, thus demonstrating the capabilities of a system for researchers to establish both short-term continuous and intermittent hypoxia regimes. A Parylene-C thin-film coating was used to prevent ambient air penetration through the bulk PDMS and was found to yield improved equilibration times and end-point concentrations. MDA-MD-231 cells, an invasive breast cancer line, were used as a model cell type to demonstrate the effect of oxygen concentration on cell migration through the Boyden chamber porous membrane. Continuous hypoxia downregulated migration of cells relative to the normoxic control, as did an intermittent hypoxia regime (IH) cycling between 0% and 21% oxygen (0-21% IH). However, cells exposed to 5-21% IH exhibited increased migration compared to the other conditions, as well as relative to the normoxic control. The results presented here show the device can be utilized for experiments implementing the Boyden chamber for in vitro hypoxic studies, allowing experiments to be conducted faster and with more precision than currently possible.</description><identifier>ISSN: 1473-0197</identifier><identifier>EISSN: 1473-0189</identifier><identifier>DOI: 10.1039/c004856a</identifier><identifier>PMID: 20689862</identifier><language>eng</language><publisher>England</publisher><subject>Balancing ; Cancer ; Cell Hypoxia ; Cell Line, Tumor ; Cell Movement ; Chambers ; Devices ; Diffusion ; Dimethylpolysiloxanes ; Humans ; Hypoxia ; In vitro testing ; Membranes, Artificial ; Microtechnology - methods ; Migration ; Neoplasm Invasiveness ; Oxygen - metabolism ; Polymers - chemistry ; Porosity ; Silicone resins ; Xylenes - chemistry</subject><ispartof>Lab on a chip, 2010-01, Vol.10 (18), p.2366-2373</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c381t-8f82a4430a90b2b4168509a194c589d967611231e17cbf48db85310822d802593</citedby><cites>FETCH-LOGICAL-c381t-8f82a4430a90b2b4168509a194c589d967611231e17cbf48db85310822d802593</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20689862$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Oppegard, Shawn C</creatorcontrib><creatorcontrib>Blake, Alexander J</creatorcontrib><creatorcontrib>Williams, Justin C</creatorcontrib><creatorcontrib>Eddington, David T</creatorcontrib><title>Precise control over the oxygen conditions within the Boyden chamber using a microfabricated insert</title><title>Lab on a chip</title><addtitle>Lab Chip</addtitle><description>Cell migration is a hallmark of cancer cell metastasis and is highly correlated with hypoxia in tumors. The Boyden chamber is a porous membrane-based migration platform that has seen a great deal of use for both in vitro migration and invasion assays due to its adaptability to common culture vessels and relative ease of use. The hypoxic chamber is a current tool that can be implemented to investigate the cellular response to oxygen paradigms. Unfortunately, this method lacks the spatial and temporal precision to accurately model a number of physiological phenomena. In this article, we present a newly developed microfabricated polydimethylsiloxane (PDMS) device that easily adapts to the Boyden chamber, and provides more control over the oxygenation conditions exposed to cells. The device equilibrates to 1% oxygen in about 20 min, thus demonstrating the capabilities of a system for researchers to establish both short-term continuous and intermittent hypoxia regimes. A Parylene-C thin-film coating was used to prevent ambient air penetration through the bulk PDMS and was found to yield improved equilibration times and end-point concentrations. MDA-MD-231 cells, an invasive breast cancer line, were used as a model cell type to demonstrate the effect of oxygen concentration on cell migration through the Boyden chamber porous membrane. Continuous hypoxia downregulated migration of cells relative to the normoxic control, as did an intermittent hypoxia regime (IH) cycling between 0% and 21% oxygen (0-21% IH). However, cells exposed to 5-21% IH exhibited increased migration compared to the other conditions, as well as relative to the normoxic control. The results presented here show the device can be utilized for experiments implementing the Boyden chamber for in vitro hypoxic studies, allowing experiments to be conducted faster and with more precision than currently possible.</description><subject>Balancing</subject><subject>Cancer</subject><subject>Cell Hypoxia</subject><subject>Cell Line, Tumor</subject><subject>Cell Movement</subject><subject>Chambers</subject><subject>Devices</subject><subject>Diffusion</subject><subject>Dimethylpolysiloxanes</subject><subject>Humans</subject><subject>Hypoxia</subject><subject>In vitro testing</subject><subject>Membranes, Artificial</subject><subject>Microtechnology - methods</subject><subject>Migration</subject><subject>Neoplasm Invasiveness</subject><subject>Oxygen - metabolism</subject><subject>Polymers - chemistry</subject><subject>Porosity</subject><subject>Silicone resins</subject><subject>Xylenes - chemistry</subject><issn>1473-0197</issn><issn>1473-0189</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kEtPwzAQhC0EoqUg8QuQb3AJrB9J7CNUvKRKcIBz5DhOa5TExXaA_ntSaMuN0652Ps1qBqFTApcEmLzSAFykmdpDY8JzlgARcn-3y3yEjkJ4AyApz8QhGlHIhBQZHSP97I22wWDtuuhdg92H8TguDHZfq7np1vfKRuu6gD9tXNjuR7xxq2otLlRbDnwfbDfHCrdWe1er0lutoqmw7YLx8Rgd1KoJ5mQzJ-j17vZl-pDMnu4fp9ezRDNBYiJqQRXnDJSEkpacZCIFqYjkOhWyklmeEUIZMSTXZc1FVYqUERCUVgJoKtkEnf_6Lr17702IRWuDNk2jOuP6UOR8CJ0LDgN58S9JaDZ8A8nyP3RIFoI3dbH0tlV-VRAo1uUX2_IH9Gzj2petqXbgtm32DR5bffs</recordid><startdate>20100101</startdate><enddate>20100101</enddate><creator>Oppegard, Shawn C</creator><creator>Blake, Alexander J</creator><creator>Williams, Justin C</creator><creator>Eddington, David T</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>20100101</creationdate><title>Precise control over the oxygen conditions within the Boyden chamber using a microfabricated insert</title><author>Oppegard, Shawn C ; Blake, Alexander J ; Williams, Justin C ; Eddington, David T</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c381t-8f82a4430a90b2b4168509a194c589d967611231e17cbf48db85310822d802593</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Balancing</topic><topic>Cancer</topic><topic>Cell Hypoxia</topic><topic>Cell Line, Tumor</topic><topic>Cell Movement</topic><topic>Chambers</topic><topic>Devices</topic><topic>Diffusion</topic><topic>Dimethylpolysiloxanes</topic><topic>Humans</topic><topic>Hypoxia</topic><topic>In vitro testing</topic><topic>Membranes, Artificial</topic><topic>Microtechnology - methods</topic><topic>Migration</topic><topic>Neoplasm Invasiveness</topic><topic>Oxygen - metabolism</topic><topic>Polymers - chemistry</topic><topic>Porosity</topic><topic>Silicone resins</topic><topic>Xylenes - chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Oppegard, Shawn C</creatorcontrib><creatorcontrib>Blake, Alexander J</creatorcontrib><creatorcontrib>Williams, Justin C</creatorcontrib><creatorcontrib>Eddington, David T</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Lab on a chip</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Oppegard, Shawn C</au><au>Blake, Alexander J</au><au>Williams, Justin C</au><au>Eddington, David T</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Precise control over the oxygen conditions within the Boyden chamber using a microfabricated insert</atitle><jtitle>Lab on a chip</jtitle><addtitle>Lab Chip</addtitle><date>2010-01-01</date><risdate>2010</risdate><volume>10</volume><issue>18</issue><spage>2366</spage><epage>2373</epage><pages>2366-2373</pages><issn>1473-0197</issn><eissn>1473-0189</eissn><abstract>Cell migration is a hallmark of cancer cell metastasis and is highly correlated with hypoxia in tumors. The Boyden chamber is a porous membrane-based migration platform that has seen a great deal of use for both in vitro migration and invasion assays due to its adaptability to common culture vessels and relative ease of use. The hypoxic chamber is a current tool that can be implemented to investigate the cellular response to oxygen paradigms. Unfortunately, this method lacks the spatial and temporal precision to accurately model a number of physiological phenomena. In this article, we present a newly developed microfabricated polydimethylsiloxane (PDMS) device that easily adapts to the Boyden chamber, and provides more control over the oxygenation conditions exposed to cells. The device equilibrates to 1% oxygen in about 20 min, thus demonstrating the capabilities of a system for researchers to establish both short-term continuous and intermittent hypoxia regimes. A Parylene-C thin-film coating was used to prevent ambient air penetration through the bulk PDMS and was found to yield improved equilibration times and end-point concentrations. MDA-MD-231 cells, an invasive breast cancer line, were used as a model cell type to demonstrate the effect of oxygen concentration on cell migration through the Boyden chamber porous membrane. Continuous hypoxia downregulated migration of cells relative to the normoxic control, as did an intermittent hypoxia regime (IH) cycling between 0% and 21% oxygen (0-21% IH). However, cells exposed to 5-21% IH exhibited increased migration compared to the other conditions, as well as relative to the normoxic control. The results presented here show the device can be utilized for experiments implementing the Boyden chamber for in vitro hypoxic studies, allowing experiments to be conducted faster and with more precision than currently possible.</abstract><cop>England</cop><pmid>20689862</pmid><doi>10.1039/c004856a</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1473-0197
ispartof Lab on a chip, 2010-01, Vol.10 (18), p.2366-2373
issn 1473-0197
1473-0189
language eng
recordid cdi_proquest_miscellaneous_748987840
source MEDLINE; Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection
subjects Balancing
Cancer
Cell Hypoxia
Cell Line, Tumor
Cell Movement
Chambers
Devices
Diffusion
Dimethylpolysiloxanes
Humans
Hypoxia
In vitro testing
Membranes, Artificial
Microtechnology - methods
Migration
Neoplasm Invasiveness
Oxygen - metabolism
Polymers - chemistry
Porosity
Silicone resins
Xylenes - chemistry
title Precise control over the oxygen conditions within the Boyden chamber using a microfabricated insert
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T03%3A34%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Precise%20control%20over%20the%20oxygen%20conditions%20within%20the%20Boyden%20chamber%20using%20a%20microfabricated%20insert&rft.jtitle=Lab%20on%20a%20chip&rft.au=Oppegard,%20Shawn%20C&rft.date=2010-01-01&rft.volume=10&rft.issue=18&rft.spage=2366&rft.epage=2373&rft.pages=2366-2373&rft.issn=1473-0197&rft.eissn=1473-0189&rft_id=info:doi/10.1039/c004856a&rft_dat=%3Cproquest_cross%3E748987840%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1266760937&rft_id=info:pmid/20689862&rfr_iscdi=true