GRAY SCALE TRANSRECTAL ULTRASONOTOMOGRAPHY: 2. Clinical Evaluation for Prostatic Echography

The improved gray scale echography in transrectal ultrasonotomography can provide fine visualization of anatomical structures and pathological changes of prostatic gland. Ultrasonic findings from the inside of the prostate were classified into three acoustical patterns: solid pattern, cystic pattern...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nippon Hinyokika Gakkai zasshi 1979/10/20, Vol.70(10), pp.1078-1087
Hauptverfasser: Harada, Kazuya, Igari, Dairoku, Tanahashi, Yoshikatsu
Format: Artikel
Sprache:jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1087
container_issue 10
container_start_page 1078
container_title Nippon Hinyokika Gakkai zasshi
container_volume 70
creator Harada, Kazuya
Igari, Dairoku
Tanahashi, Yoshikatsu
description The improved gray scale echography in transrectal ultrasonotomography can provide fine visualization of anatomical structures and pathological changes of prostatic gland. Ultrasonic findings from the inside of the prostate were classified into three acoustical patterns: solid pattern, cystic pattern and mixed pattern. The findings under each pattern were sub-classified according to their shape, distribution and border. Another classification was also done from pathoanatomical view dividing the findings into inner gland pattern, outer gland pattern, nodule pattern, stone pattern and miscellaneous. Each pattern was statistically evaluated in normal and abnormal prostate. Diagnostic criteria for prostatic diseases were revised, considering the internal echo patterns from the prostate. Diagnostic accuracy in 167 gray scale prostatic scans was 89per cent, 9per cent higher as compared with that of conventional scan. Gray scale transrectal ultrasonotomography proved to be more accurate diagnostic means for analysis of prostatic pathology.
doi_str_mv 10.5980/jpnjurol1928.70.10_1078
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_74897286</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>74897286</sourcerecordid><originalsourceid>FETCH-LOGICAL-j187t-5694aed4bc85901174411180007027dcab1ca8f8847a580b1e3d3eeaecac5ca63</originalsourceid><addsrcrecordid>eNpNkM1PwkAQxTdGogT5CzzIyYNJcabbZafHhiAYKzVQDpw22-2ibcqH_Tj431uEEC8zmbxfXuY9xh4QhsIneM4Pu7wp9wX6Lg0lDBEUgqQr1kUiz5GIcM26AC46wiV5y_pVlSXAUZJLnN-wjs9ReF32NF0E68FyHISTQbwI5svFZBwH4WAVttcymkdx9B61zMdsfcc6G11Utn_ePbZ6mcTjmRNG09fWwMmRZO2Ike9pm3qJIeEDovQ8RCQAkODK1OgEjaZN-6bUgiBBy1NurbZGG2H0iPfY48n3UO6_G1vVaptVxhaF3tl9UynpkS9dOoL3Z7BJtjZVhzLb6vJH_UVr1beTmle1_rQXVZd1Zgqr_leo5LG_8zwWeaHMly6V3fFfKtxp5g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>74897286</pqid></control><display><type>article</type><title>GRAY SCALE TRANSRECTAL ULTRASONOTOMOGRAPHY: 2. Clinical Evaluation for Prostatic Echography</title><source>J-STAGE Free</source><source>MEDLINE</source><creator>Harada, Kazuya ; Igari, Dairoku ; Tanahashi, Yoshikatsu</creator><creatorcontrib>Harada, Kazuya ; Igari, Dairoku ; Tanahashi, Yoshikatsu</creatorcontrib><description>The improved gray scale echography in transrectal ultrasonotomography can provide fine visualization of anatomical structures and pathological changes of prostatic gland. Ultrasonic findings from the inside of the prostate were classified into three acoustical patterns: solid pattern, cystic pattern and mixed pattern. The findings under each pattern were sub-classified according to their shape, distribution and border. Another classification was also done from pathoanatomical view dividing the findings into inner gland pattern, outer gland pattern, nodule pattern, stone pattern and miscellaneous. Each pattern was statistically evaluated in normal and abnormal prostate. Diagnostic criteria for prostatic diseases were revised, considering the internal echo patterns from the prostate. Diagnostic accuracy in 167 gray scale prostatic scans was 89per cent, 9per cent higher as compared with that of conventional scan. Gray scale transrectal ultrasonotomography proved to be more accurate diagnostic means for analysis of prostatic pathology.</description><identifier>ISSN: 0021-5287</identifier><identifier>EISSN: 1884-7110</identifier><identifier>DOI: 10.5980/jpnjurol1928.70.10_1078</identifier><identifier>PMID: 93154</identifier><language>jpn</language><publisher>Japan: THE JAPANESE UROLOGICAL ASSOCIATION</publisher><subject>Humans ; Male ; Prostate - anatomy &amp; histology ; Prostatic Hyperplasia - diagnosis ; Prostatic Neoplasms - diagnosis ; Prostatitis - diagnosis ; Tomography - methods ; Ultrasonography</subject><ispartof>The Japanese Journal of Urology, 1979/10/20, Vol.70(10), pp.1078-1087</ispartof><rights>Japanese Urological Association</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1877,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/93154$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Harada, Kazuya</creatorcontrib><creatorcontrib>Igari, Dairoku</creatorcontrib><creatorcontrib>Tanahashi, Yoshikatsu</creatorcontrib><title>GRAY SCALE TRANSRECTAL ULTRASONOTOMOGRAPHY: 2. Clinical Evaluation for Prostatic Echography</title><title>Nippon Hinyokika Gakkai zasshi</title><addtitle>Jpn. j. urol</addtitle><description>The improved gray scale echography in transrectal ultrasonotomography can provide fine visualization of anatomical structures and pathological changes of prostatic gland. Ultrasonic findings from the inside of the prostate were classified into three acoustical patterns: solid pattern, cystic pattern and mixed pattern. The findings under each pattern were sub-classified according to their shape, distribution and border. Another classification was also done from pathoanatomical view dividing the findings into inner gland pattern, outer gland pattern, nodule pattern, stone pattern and miscellaneous. Each pattern was statistically evaluated in normal and abnormal prostate. Diagnostic criteria for prostatic diseases were revised, considering the internal echo patterns from the prostate. Diagnostic accuracy in 167 gray scale prostatic scans was 89per cent, 9per cent higher as compared with that of conventional scan. Gray scale transrectal ultrasonotomography proved to be more accurate diagnostic means for analysis of prostatic pathology.</description><subject>Humans</subject><subject>Male</subject><subject>Prostate - anatomy &amp; histology</subject><subject>Prostatic Hyperplasia - diagnosis</subject><subject>Prostatic Neoplasms - diagnosis</subject><subject>Prostatitis - diagnosis</subject><subject>Tomography - methods</subject><subject>Ultrasonography</subject><issn>0021-5287</issn><issn>1884-7110</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1979</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNkM1PwkAQxTdGogT5CzzIyYNJcabbZafHhiAYKzVQDpw22-2ibcqH_Tj431uEEC8zmbxfXuY9xh4QhsIneM4Pu7wp9wX6Lg0lDBEUgqQr1kUiz5GIcM26AC46wiV5y_pVlSXAUZJLnN-wjs9ReF32NF0E68FyHISTQbwI5svFZBwH4WAVttcymkdx9B61zMdsfcc6G11Utn_ePbZ6mcTjmRNG09fWwMmRZO2Ike9pm3qJIeEDovQ8RCQAkODK1OgEjaZN-6bUgiBBy1NurbZGG2H0iPfY48n3UO6_G1vVaptVxhaF3tl9UynpkS9dOoL3Z7BJtjZVhzLb6vJH_UVr1beTmle1_rQXVZd1Zgqr_leo5LG_8zwWeaHMly6V3fFfKtxp5g</recordid><startdate>197910</startdate><enddate>197910</enddate><creator>Harada, Kazuya</creator><creator>Igari, Dairoku</creator><creator>Tanahashi, Yoshikatsu</creator><general>THE JAPANESE UROLOGICAL ASSOCIATION</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>197910</creationdate><title>GRAY SCALE TRANSRECTAL ULTRASONOTOMOGRAPHY</title><author>Harada, Kazuya ; Igari, Dairoku ; Tanahashi, Yoshikatsu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-j187t-5694aed4bc85901174411180007027dcab1ca8f8847a580b1e3d3eeaecac5ca63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>jpn</language><creationdate>1979</creationdate><topic>Humans</topic><topic>Male</topic><topic>Prostate - anatomy &amp; histology</topic><topic>Prostatic Hyperplasia - diagnosis</topic><topic>Prostatic Neoplasms - diagnosis</topic><topic>Prostatitis - diagnosis</topic><topic>Tomography - methods</topic><topic>Ultrasonography</topic><toplevel>online_resources</toplevel><creatorcontrib>Harada, Kazuya</creatorcontrib><creatorcontrib>Igari, Dairoku</creatorcontrib><creatorcontrib>Tanahashi, Yoshikatsu</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Nippon Hinyokika Gakkai zasshi</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Harada, Kazuya</au><au>Igari, Dairoku</au><au>Tanahashi, Yoshikatsu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>GRAY SCALE TRANSRECTAL ULTRASONOTOMOGRAPHY: 2. Clinical Evaluation for Prostatic Echography</atitle><jtitle>Nippon Hinyokika Gakkai zasshi</jtitle><addtitle>Jpn. j. urol</addtitle><date>1979-10</date><risdate>1979</risdate><volume>70</volume><issue>10</issue><spage>1078</spage><epage>1087</epage><pages>1078-1087</pages><issn>0021-5287</issn><eissn>1884-7110</eissn><abstract>The improved gray scale echography in transrectal ultrasonotomography can provide fine visualization of anatomical structures and pathological changes of prostatic gland. Ultrasonic findings from the inside of the prostate were classified into three acoustical patterns: solid pattern, cystic pattern and mixed pattern. The findings under each pattern were sub-classified according to their shape, distribution and border. Another classification was also done from pathoanatomical view dividing the findings into inner gland pattern, outer gland pattern, nodule pattern, stone pattern and miscellaneous. Each pattern was statistically evaluated in normal and abnormal prostate. Diagnostic criteria for prostatic diseases were revised, considering the internal echo patterns from the prostate. Diagnostic accuracy in 167 gray scale prostatic scans was 89per cent, 9per cent higher as compared with that of conventional scan. Gray scale transrectal ultrasonotomography proved to be more accurate diagnostic means for analysis of prostatic pathology.</abstract><cop>Japan</cop><pub>THE JAPANESE UROLOGICAL ASSOCIATION</pub><pmid>93154</pmid><doi>10.5980/jpnjurol1928.70.10_1078</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0021-5287
ispartof The Japanese Journal of Urology, 1979/10/20, Vol.70(10), pp.1078-1087
issn 0021-5287
1884-7110
language jpn
recordid cdi_proquest_miscellaneous_74897286
source J-STAGE Free; MEDLINE
subjects Humans
Male
Prostate - anatomy & histology
Prostatic Hyperplasia - diagnosis
Prostatic Neoplasms - diagnosis
Prostatitis - diagnosis
Tomography - methods
Ultrasonography
title GRAY SCALE TRANSRECTAL ULTRASONOTOMOGRAPHY: 2. Clinical Evaluation for Prostatic Echography
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-04T10%3A30%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=GRAY%20SCALE%20TRANSRECTAL%20ULTRASONOTOMOGRAPHY:%202.%20Clinical%20Evaluation%20for%20Prostatic%20Echography&rft.jtitle=Nippon%20Hinyokika%20Gakkai%20zasshi&rft.au=Harada,%20Kazuya&rft.date=1979-10&rft.volume=70&rft.issue=10&rft.spage=1078&rft.epage=1087&rft.pages=1078-1087&rft.issn=0021-5287&rft.eissn=1884-7110&rft_id=info:doi/10.5980/jpnjurol1928.70.10_1078&rft_dat=%3Cproquest_pubme%3E74897286%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=74897286&rft_id=info:pmid/93154&rfr_iscdi=true