Transcatheter Electrocoagulation: Experimental Evaluation of the Anode
Transcatheter electrocoagulation using direct current has been shown to be an effective method for vessel occlusion. To date, the stainless steel anode has not been entirely satisfactory. Thus, an evaluation of bipolar platinum electrodes and a comparison of monopolar platinum and stainless steel el...
Gespeichert in:
Veröffentlicht in: | Investigative radiology 1979-01, Vol.14 (1), p.41-47 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 47 |
---|---|
container_issue | 1 |
container_start_page | 41 |
container_title | Investigative radiology |
container_volume | 14 |
creator | THOMPSON, WILLIAM M MCALISTER, DAVID S MILLER, MICHAEL PIZZO, SALVATORE V JACKSON, DONALD C JOHNSRUDE, IRWIN S |
description | Transcatheter electrocoagulation using direct current has been shown to be an effective method for vessel occlusion. To date, the stainless steel anode has not been entirely satisfactory. Thus, an evaluation of bipolar platinum electrodes and a comparison of monopolar platinum and stainless steel electrodes have been performed. Experimental results have shown that both monopolar and bipolar platinum electrodes caused perforation in most cases. At the present time, we have not found a satisfactory replacement for the unipolar stainless steel anode. |
doi_str_mv | 10.1097/00004424-197901000-00008 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_74692292</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>74692292</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3548-6fffcbbfc14aa834ebfe2c02f21d21492cb989ef7f00ccd8bc1c755b329e519c3</originalsourceid><addsrcrecordid>eNp1kU9TwyAQxRnHf7X6DTzk5C0KhCTgrdNJ1RlnvNQzQ8hiqzRUSKx-e2lTe5PLDvveW4bfIpQQfEuwKO9wPIxRlhJRCkziLd22-BEakTwrUkwJPkYjjClOhRDFOboI4T06aImzM3TKSl6KfIRmc6_aoFW3gA58UlnQnXfaqbfeqm7p2vuk-l6DX66g7ZRNqi9l-52QOJPEVDJpXQOX6MQoG-BqX8fodVbNp4_p88vD03TynOosZzwtjDG6ro0mTCmeMagNUI2poaShhAmqa8EFmNJgrHXDa010med1RgXkROhsjG6GuWvvPnsInVwtgwZrVQuuD7JkhaBU0Gjkg1F7F4IHI9fxD8r_SILllqD8IygPBHctHqPX-zf6egXNITggizIb5I2zEVn4sP0GvFyAst1C_reX7Bf3RXx0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>74692292</pqid></control><display><type>article</type><title>Transcatheter Electrocoagulation: Experimental Evaluation of the Anode</title><source>MEDLINE</source><source>Journals@Ovid Ovid Autoload</source><creator>THOMPSON, WILLIAM M ; MCALISTER, DAVID S ; MILLER, MICHAEL ; PIZZO, SALVATORE V ; JACKSON, DONALD C ; JOHNSRUDE, IRWIN S</creator><creatorcontrib>THOMPSON, WILLIAM M ; MCALISTER, DAVID S ; MILLER, MICHAEL ; PIZZO, SALVATORE V ; JACKSON, DONALD C ; JOHNSRUDE, IRWIN S</creatorcontrib><description>Transcatheter electrocoagulation using direct current has been shown to be an effective method for vessel occlusion. To date, the stainless steel anode has not been entirely satisfactory. Thus, an evaluation of bipolar platinum electrodes and a comparison of monopolar platinum and stainless steel electrodes have been performed. Experimental results have shown that both monopolar and bipolar platinum electrodes caused perforation in most cases. At the present time, we have not found a satisfactory replacement for the unipolar stainless steel anode.</description><identifier>ISSN: 0020-9996</identifier><identifier>EISSN: 1536-0210</identifier><identifier>DOI: 10.1097/00004424-197901000-00008</identifier><identifier>PMID: 478795</identifier><language>eng</language><publisher>United States: Lippincott-Raven Publishers</publisher><subject>Animals ; Catheterization - instrumentation ; Dogs ; Electrocoagulation - instrumentation ; Electrodes ; Evaluation Studies as Topic ; Femoral Artery - diagnostic imaging ; Femoral Artery - pathology ; Platinum ; Radiography ; Renal Artery - diagnostic imaging ; Renal Artery - pathology ; Steel ; Thrombosis - diagnostic imaging ; Thrombosis - pathology</subject><ispartof>Investigative radiology, 1979-01, Vol.14 (1), p.41-47</ispartof><rights>Lippincott-Raven Publishers.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3548-6fffcbbfc14aa834ebfe2c02f21d21492cb989ef7f00ccd8bc1c755b329e519c3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/478795$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>THOMPSON, WILLIAM M</creatorcontrib><creatorcontrib>MCALISTER, DAVID S</creatorcontrib><creatorcontrib>MILLER, MICHAEL</creatorcontrib><creatorcontrib>PIZZO, SALVATORE V</creatorcontrib><creatorcontrib>JACKSON, DONALD C</creatorcontrib><creatorcontrib>JOHNSRUDE, IRWIN S</creatorcontrib><title>Transcatheter Electrocoagulation: Experimental Evaluation of the Anode</title><title>Investigative radiology</title><addtitle>Invest Radiol</addtitle><description>Transcatheter electrocoagulation using direct current has been shown to be an effective method for vessel occlusion. To date, the stainless steel anode has not been entirely satisfactory. Thus, an evaluation of bipolar platinum electrodes and a comparison of monopolar platinum and stainless steel electrodes have been performed. Experimental results have shown that both monopolar and bipolar platinum electrodes caused perforation in most cases. At the present time, we have not found a satisfactory replacement for the unipolar stainless steel anode.</description><subject>Animals</subject><subject>Catheterization - instrumentation</subject><subject>Dogs</subject><subject>Electrocoagulation - instrumentation</subject><subject>Electrodes</subject><subject>Evaluation Studies as Topic</subject><subject>Femoral Artery - diagnostic imaging</subject><subject>Femoral Artery - pathology</subject><subject>Platinum</subject><subject>Radiography</subject><subject>Renal Artery - diagnostic imaging</subject><subject>Renal Artery - pathology</subject><subject>Steel</subject><subject>Thrombosis - diagnostic imaging</subject><subject>Thrombosis - pathology</subject><issn>0020-9996</issn><issn>1536-0210</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1979</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kU9TwyAQxRnHf7X6DTzk5C0KhCTgrdNJ1RlnvNQzQ8hiqzRUSKx-e2lTe5PLDvveW4bfIpQQfEuwKO9wPIxRlhJRCkziLd22-BEakTwrUkwJPkYjjClOhRDFOboI4T06aImzM3TKSl6KfIRmc6_aoFW3gA58UlnQnXfaqbfeqm7p2vuk-l6DX66g7ZRNqi9l-52QOJPEVDJpXQOX6MQoG-BqX8fodVbNp4_p88vD03TynOosZzwtjDG6ro0mTCmeMagNUI2poaShhAmqa8EFmNJgrHXDa010med1RgXkROhsjG6GuWvvPnsInVwtgwZrVQuuD7JkhaBU0Gjkg1F7F4IHI9fxD8r_SILllqD8IygPBHctHqPX-zf6egXNITggizIb5I2zEVn4sP0GvFyAst1C_reX7Bf3RXx0</recordid><startdate>197901</startdate><enddate>197901</enddate><creator>THOMPSON, WILLIAM M</creator><creator>MCALISTER, DAVID S</creator><creator>MILLER, MICHAEL</creator><creator>PIZZO, SALVATORE V</creator><creator>JACKSON, DONALD C</creator><creator>JOHNSRUDE, IRWIN S</creator><general>Lippincott-Raven Publishers</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>197901</creationdate><title>Transcatheter Electrocoagulation: Experimental Evaluation of the Anode</title><author>THOMPSON, WILLIAM M ; MCALISTER, DAVID S ; MILLER, MICHAEL ; PIZZO, SALVATORE V ; JACKSON, DONALD C ; JOHNSRUDE, IRWIN S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3548-6fffcbbfc14aa834ebfe2c02f21d21492cb989ef7f00ccd8bc1c755b329e519c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1979</creationdate><topic>Animals</topic><topic>Catheterization - instrumentation</topic><topic>Dogs</topic><topic>Electrocoagulation - instrumentation</topic><topic>Electrodes</topic><topic>Evaluation Studies as Topic</topic><topic>Femoral Artery - diagnostic imaging</topic><topic>Femoral Artery - pathology</topic><topic>Platinum</topic><topic>Radiography</topic><topic>Renal Artery - diagnostic imaging</topic><topic>Renal Artery - pathology</topic><topic>Steel</topic><topic>Thrombosis - diagnostic imaging</topic><topic>Thrombosis - pathology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>THOMPSON, WILLIAM M</creatorcontrib><creatorcontrib>MCALISTER, DAVID S</creatorcontrib><creatorcontrib>MILLER, MICHAEL</creatorcontrib><creatorcontrib>PIZZO, SALVATORE V</creatorcontrib><creatorcontrib>JACKSON, DONALD C</creatorcontrib><creatorcontrib>JOHNSRUDE, IRWIN S</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Investigative radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>THOMPSON, WILLIAM M</au><au>MCALISTER, DAVID S</au><au>MILLER, MICHAEL</au><au>PIZZO, SALVATORE V</au><au>JACKSON, DONALD C</au><au>JOHNSRUDE, IRWIN S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Transcatheter Electrocoagulation: Experimental Evaluation of the Anode</atitle><jtitle>Investigative radiology</jtitle><addtitle>Invest Radiol</addtitle><date>1979-01</date><risdate>1979</risdate><volume>14</volume><issue>1</issue><spage>41</spage><epage>47</epage><pages>41-47</pages><issn>0020-9996</issn><eissn>1536-0210</eissn><abstract>Transcatheter electrocoagulation using direct current has been shown to be an effective method for vessel occlusion. To date, the stainless steel anode has not been entirely satisfactory. Thus, an evaluation of bipolar platinum electrodes and a comparison of monopolar platinum and stainless steel electrodes have been performed. Experimental results have shown that both monopolar and bipolar platinum electrodes caused perforation in most cases. At the present time, we have not found a satisfactory replacement for the unipolar stainless steel anode.</abstract><cop>United States</cop><pub>Lippincott-Raven Publishers</pub><pmid>478795</pmid><doi>10.1097/00004424-197901000-00008</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0020-9996 |
ispartof | Investigative radiology, 1979-01, Vol.14 (1), p.41-47 |
issn | 0020-9996 1536-0210 |
language | eng |
recordid | cdi_proquest_miscellaneous_74692292 |
source | MEDLINE; Journals@Ovid Ovid Autoload |
subjects | Animals Catheterization - instrumentation Dogs Electrocoagulation - instrumentation Electrodes Evaluation Studies as Topic Femoral Artery - diagnostic imaging Femoral Artery - pathology Platinum Radiography Renal Artery - diagnostic imaging Renal Artery - pathology Steel Thrombosis - diagnostic imaging Thrombosis - pathology |
title | Transcatheter Electrocoagulation: Experimental Evaluation of the Anode |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T02%3A04%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Transcatheter%20Electrocoagulation:%20Experimental%20Evaluation%20of%20the%20Anode&rft.jtitle=Investigative%20radiology&rft.au=THOMPSON,%20WILLIAM%20M&rft.date=1979-01&rft.volume=14&rft.issue=1&rft.spage=41&rft.epage=47&rft.pages=41-47&rft.issn=0020-9996&rft.eissn=1536-0210&rft_id=info:doi/10.1097/00004424-197901000-00008&rft_dat=%3Cproquest_cross%3E74692292%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=74692292&rft_id=info:pmid/478795&rfr_iscdi=true |