A study on the performance of multi-stage condensation heat pumps
In this study, computer simulation programs were developed for multi-stage condensation heat pumps and their performance was examined for CFC11, HCFC123, HCFC141b under the same condition. The results showed that the coefficient of performance (COP) of an optimized ‘non-split type’ three-stage conde...
Gespeichert in:
Veröffentlicht in: | International journal of refrigeration 2000-11, Vol.23 (7), p.528-539 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 539 |
---|---|
container_issue | 7 |
container_start_page | 528 |
container_title | International journal of refrigeration |
container_volume | 23 |
creator | Jung, Dongsoo Lee, Yoonhak Park, Byungjin Kang, Byoungha |
description | In this study, computer simulation programs were developed for multi-stage condensation heat pumps and their performance was examined for CFC11, HCFC123, HCFC141b under the same condition. The results showed that the coefficient of performance (COP) of an optimized ‘non-split type’ three-stage condensation heat pump was 25–42% higher than that of a conventional single-stage heat pump. The increase in COP differed among the fluids examined. The improvement in COP was due largely to the decrease in average temperature difference between the refrigerant and water in the condensers, which resulted in a decrease in thermodynamic irreversibility. For the three-stage heat pump, the highest COP was achieved when the total condenser area was evenly distributed to the three condensers. For the two-stage heat pump, however, the optimum distribution of total condenser area varied with working fluids. For the three-stage system, splitting the condenser cooling water for the use of intermediate and high pressure subcoolers helped increase the COP further. When the individual cooling water for the intermediate and high pressure subcoolers was roughly 10% of the total condenser cooling water, the optimum COP was achieved showing an additional 11% increase in COP as compared to that of the ‘non-split type’ for the three-stage heat pump system.
Dans cette étude, on a développé des programmes de simulation informatiques afin d'étudier la performance des pompes à chaleur à condensation en plusieurs étages utilisant les frigorigènes suivants sous des conditions identiques : CFC11, HCFC123, HCFC123 et HCFC141b. Les résultats ont montré que le coefficient de performance (COP) d'une pompe à chaleur à condensation
optimisée à trois étages de type non split était supérieure de 25 à 42 % à celle d'une pompe à chaleur monoétagée classique. L'augmentation du COP obtenue variait selon les frigorigènes étudiés ; elle était surtout fonction de la diminution de la température moyenne entre le frigorigène et l'eau dans les condenseurs, donnant lieu à une irreversibilité thermodynamique diminuée. Pour la pompe à chaleur à trois étages, le COP plus élevé a été obtenu lorsque la superficie de condensation totale était distribuée de façon, uniforme à travers les trois condenseurs. Cependant, pour la pompe à chaleur biétagée, la distribution optimale de la superficie totale du condenseur variait selon les frigorigènes utilisés. Pour le système à trois étages, la répartition de l'eau de refroidi |
doi_str_mv | 10.1016/S0140-7007(99)00083-3 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_746166976</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0140700799000833</els_id><sourcerecordid>746166976</sourcerecordid><originalsourceid>FETCH-LOGICAL-c406t-33634fe6492cf5c62478eca61e228541f3d0be53d93e5732bee559f6cbe9fcb03</originalsourceid><addsrcrecordid>eNqFkEtLxDAUhYMoOI7-BKELQV1Ub5o2bVYyDL5gwIW6Dpn0xom0TU1SYf69nQe6dHU33zmH-xFyTuGGAuW3r0BzSEuA8kqIawCoWMoOyIRWpUgzqOghmfwix-QkhE8AWkJRTchsloQ41OvEdUlcYdKjN863qtOYOJO0QxNtGqL6wES7rsYuqGhHdoUqJv3Q9uGUHBnVBDzb3yl5f7h_mz-li5fH5_lskeoceEwZ4yw3yHORaVNonuVlhVpxillWFTk1rIYlFqwWDIuSZUvEohCG6yUKo5fApuRy19t79zVgiLK1QWPTqA7dEGSZc8q5KPlIFjtSexeCRyN7b1vl15KC3BiTW2Nyo0MKIbfGJBtzF_sFFbRqjB8t2PAXzjMhqBixux2G47ffFr0M2uIorLYedZS1s_8M_QAv9n8n</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>746166976</pqid></control><display><type>article</type><title>A study on the performance of multi-stage condensation heat pumps</title><source>Access via ScienceDirect (Elsevier)</source><creator>Jung, Dongsoo ; Lee, Yoonhak ; Park, Byungjin ; Kang, Byoungha</creator><creatorcontrib>Jung, Dongsoo ; Lee, Yoonhak ; Park, Byungjin ; Kang, Byoungha</creatorcontrib><description>In this study, computer simulation programs were developed for multi-stage condensation heat pumps and their performance was examined for CFC11, HCFC123, HCFC141b under the same condition. The results showed that the coefficient of performance (COP) of an optimized ‘non-split type’ three-stage condensation heat pump was 25–42% higher than that of a conventional single-stage heat pump. The increase in COP differed among the fluids examined. The improvement in COP was due largely to the decrease in average temperature difference between the refrigerant and water in the condensers, which resulted in a decrease in thermodynamic irreversibility. For the three-stage heat pump, the highest COP was achieved when the total condenser area was evenly distributed to the three condensers. For the two-stage heat pump, however, the optimum distribution of total condenser area varied with working fluids. For the three-stage system, splitting the condenser cooling water for the use of intermediate and high pressure subcoolers helped increase the COP further. When the individual cooling water for the intermediate and high pressure subcoolers was roughly 10% of the total condenser cooling water, the optimum COP was achieved showing an additional 11% increase in COP as compared to that of the ‘non-split type’ for the three-stage heat pump system.
Dans cette étude, on a développé des programmes de simulation informatiques afin d'étudier la performance des pompes à chaleur à condensation en plusieurs étages utilisant les frigorigènes suivants sous des conditions identiques : CFC11, HCFC123, HCFC123 et HCFC141b. Les résultats ont montré que le coefficient de performance (COP) d'une pompe à chaleur à condensation
optimisée à trois étages de type non split était supérieure de 25 à 42 % à celle d'une pompe à chaleur monoétagée classique. L'augmentation du COP obtenue variait selon les frigorigènes étudiés ; elle était surtout fonction de la diminution de la température moyenne entre le frigorigène et l'eau dans les condenseurs, donnant lieu à une irreversibilité thermodynamique diminuée. Pour la pompe à chaleur à trois étages, le COP plus élevé a été obtenu lorsque la superficie de condensation totale était distribuée de façon, uniforme à travers les trois condenseurs. Cependant, pour la pompe à chaleur biétagée, la distribution optimale de la superficie totale du condenseur variait selon les frigorigènes utilisés. Pour le système à trois étages, la répartition de l'eau de refroidissement afin d'alimenter les sous-refroidisseurs à moyenne et à haute pression augmentait davantage le COP. Lorsque l'eau de refroidissement des sous-refroidisseurs à moyenne et à haute pression représentait 10% de l'eau de condensation totale, le COP optimal obtenu était supérieur d'environ 11% à celui des systèmes non « splits » pour le système de pompe à chaleur à 3 étages.</description><identifier>ISSN: 0140-7007</identifier><identifier>EISSN: 1879-2081</identifier><identifier>DOI: 10.1016/S0140-7007(99)00083-3</identifier><identifier>CODEN: IJRFDI</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Applied sciences ; Calcul ; Calculation ; Chlorofluorocarbons ; Condensation ; Cooling water ; Cycle frigorifique ; Devices using thermal energy ; Energy ; Energy. Thermal use of fuels ; Exact sciences and technology ; Fluorocarbons ; Heat pump ; Heat pump systems ; Heat pumps ; Multistage system ; Pompe à chaleur ; Refrigerating cycle ; Système polyétagé</subject><ispartof>International journal of refrigeration, 2000-11, Vol.23 (7), p.528-539</ispartof><rights>2000 Elsevier Science Ltd and IIR</rights><rights>2000 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c406t-33634fe6492cf5c62478eca61e228541f3d0be53d93e5732bee559f6cbe9fcb03</citedby><cites>FETCH-LOGICAL-c406t-33634fe6492cf5c62478eca61e228541f3d0be53d93e5732bee559f6cbe9fcb03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0140-7007(99)00083-3$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=1429919$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Jung, Dongsoo</creatorcontrib><creatorcontrib>Lee, Yoonhak</creatorcontrib><creatorcontrib>Park, Byungjin</creatorcontrib><creatorcontrib>Kang, Byoungha</creatorcontrib><title>A study on the performance of multi-stage condensation heat pumps</title><title>International journal of refrigeration</title><description>In this study, computer simulation programs were developed for multi-stage condensation heat pumps and their performance was examined for CFC11, HCFC123, HCFC141b under the same condition. The results showed that the coefficient of performance (COP) of an optimized ‘non-split type’ three-stage condensation heat pump was 25–42% higher than that of a conventional single-stage heat pump. The increase in COP differed among the fluids examined. The improvement in COP was due largely to the decrease in average temperature difference between the refrigerant and water in the condensers, which resulted in a decrease in thermodynamic irreversibility. For the three-stage heat pump, the highest COP was achieved when the total condenser area was evenly distributed to the three condensers. For the two-stage heat pump, however, the optimum distribution of total condenser area varied with working fluids. For the three-stage system, splitting the condenser cooling water for the use of intermediate and high pressure subcoolers helped increase the COP further. When the individual cooling water for the intermediate and high pressure subcoolers was roughly 10% of the total condenser cooling water, the optimum COP was achieved showing an additional 11% increase in COP as compared to that of the ‘non-split type’ for the three-stage heat pump system.
Dans cette étude, on a développé des programmes de simulation informatiques afin d'étudier la performance des pompes à chaleur à condensation en plusieurs étages utilisant les frigorigènes suivants sous des conditions identiques : CFC11, HCFC123, HCFC123 et HCFC141b. Les résultats ont montré que le coefficient de performance (COP) d'une pompe à chaleur à condensation
optimisée à trois étages de type non split était supérieure de 25 à 42 % à celle d'une pompe à chaleur monoétagée classique. L'augmentation du COP obtenue variait selon les frigorigènes étudiés ; elle était surtout fonction de la diminution de la température moyenne entre le frigorigène et l'eau dans les condenseurs, donnant lieu à une irreversibilité thermodynamique diminuée. Pour la pompe à chaleur à trois étages, le COP plus élevé a été obtenu lorsque la superficie de condensation totale était distribuée de façon, uniforme à travers les trois condenseurs. Cependant, pour la pompe à chaleur biétagée, la distribution optimale de la superficie totale du condenseur variait selon les frigorigènes utilisés. Pour le système à trois étages, la répartition de l'eau de refroidissement afin d'alimenter les sous-refroidisseurs à moyenne et à haute pression augmentait davantage le COP. Lorsque l'eau de refroidissement des sous-refroidisseurs à moyenne et à haute pression représentait 10% de l'eau de condensation totale, le COP optimal obtenu était supérieur d'environ 11% à celui des systèmes non « splits » pour le système de pompe à chaleur à 3 étages.</description><subject>Applied sciences</subject><subject>Calcul</subject><subject>Calculation</subject><subject>Chlorofluorocarbons</subject><subject>Condensation</subject><subject>Cooling water</subject><subject>Cycle frigorifique</subject><subject>Devices using thermal energy</subject><subject>Energy</subject><subject>Energy. Thermal use of fuels</subject><subject>Exact sciences and technology</subject><subject>Fluorocarbons</subject><subject>Heat pump</subject><subject>Heat pump systems</subject><subject>Heat pumps</subject><subject>Multistage system</subject><subject>Pompe à chaleur</subject><subject>Refrigerating cycle</subject><subject>Système polyétagé</subject><issn>0140-7007</issn><issn>1879-2081</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNqFkEtLxDAUhYMoOI7-BKELQV1Ub5o2bVYyDL5gwIW6Dpn0xom0TU1SYf69nQe6dHU33zmH-xFyTuGGAuW3r0BzSEuA8kqIawCoWMoOyIRWpUgzqOghmfwix-QkhE8AWkJRTchsloQ41OvEdUlcYdKjN863qtOYOJO0QxNtGqL6wES7rsYuqGhHdoUqJv3Q9uGUHBnVBDzb3yl5f7h_mz-li5fH5_lskeoceEwZ4yw3yHORaVNonuVlhVpxillWFTk1rIYlFqwWDIuSZUvEohCG6yUKo5fApuRy19t79zVgiLK1QWPTqA7dEGSZc8q5KPlIFjtSexeCRyN7b1vl15KC3BiTW2Nyo0MKIbfGJBtzF_sFFbRqjB8t2PAXzjMhqBixux2G47ffFr0M2uIorLYedZS1s_8M_QAv9n8n</recordid><startdate>20001101</startdate><enddate>20001101</enddate><creator>Jung, Dongsoo</creator><creator>Lee, Yoonhak</creator><creator>Park, Byungjin</creator><creator>Kang, Byoungha</creator><general>Elsevier Ltd</general><general>Elsevier Science</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TC</scope></search><sort><creationdate>20001101</creationdate><title>A study on the performance of multi-stage condensation heat pumps</title><author>Jung, Dongsoo ; Lee, Yoonhak ; Park, Byungjin ; Kang, Byoungha</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c406t-33634fe6492cf5c62478eca61e228541f3d0be53d93e5732bee559f6cbe9fcb03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Applied sciences</topic><topic>Calcul</topic><topic>Calculation</topic><topic>Chlorofluorocarbons</topic><topic>Condensation</topic><topic>Cooling water</topic><topic>Cycle frigorifique</topic><topic>Devices using thermal energy</topic><topic>Energy</topic><topic>Energy. Thermal use of fuels</topic><topic>Exact sciences and technology</topic><topic>Fluorocarbons</topic><topic>Heat pump</topic><topic>Heat pump systems</topic><topic>Heat pumps</topic><topic>Multistage system</topic><topic>Pompe à chaleur</topic><topic>Refrigerating cycle</topic><topic>Système polyétagé</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jung, Dongsoo</creatorcontrib><creatorcontrib>Lee, Yoonhak</creatorcontrib><creatorcontrib>Park, Byungjin</creatorcontrib><creatorcontrib>Kang, Byoungha</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Mechanical Engineering Abstracts</collection><jtitle>International journal of refrigeration</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jung, Dongsoo</au><au>Lee, Yoonhak</au><au>Park, Byungjin</au><au>Kang, Byoungha</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A study on the performance of multi-stage condensation heat pumps</atitle><jtitle>International journal of refrigeration</jtitle><date>2000-11-01</date><risdate>2000</risdate><volume>23</volume><issue>7</issue><spage>528</spage><epage>539</epage><pages>528-539</pages><issn>0140-7007</issn><eissn>1879-2081</eissn><coden>IJRFDI</coden><abstract>In this study, computer simulation programs were developed for multi-stage condensation heat pumps and their performance was examined for CFC11, HCFC123, HCFC141b under the same condition. The results showed that the coefficient of performance (COP) of an optimized ‘non-split type’ three-stage condensation heat pump was 25–42% higher than that of a conventional single-stage heat pump. The increase in COP differed among the fluids examined. The improvement in COP was due largely to the decrease in average temperature difference between the refrigerant and water in the condensers, which resulted in a decrease in thermodynamic irreversibility. For the three-stage heat pump, the highest COP was achieved when the total condenser area was evenly distributed to the three condensers. For the two-stage heat pump, however, the optimum distribution of total condenser area varied with working fluids. For the three-stage system, splitting the condenser cooling water for the use of intermediate and high pressure subcoolers helped increase the COP further. When the individual cooling water for the intermediate and high pressure subcoolers was roughly 10% of the total condenser cooling water, the optimum COP was achieved showing an additional 11% increase in COP as compared to that of the ‘non-split type’ for the three-stage heat pump system.
Dans cette étude, on a développé des programmes de simulation informatiques afin d'étudier la performance des pompes à chaleur à condensation en plusieurs étages utilisant les frigorigènes suivants sous des conditions identiques : CFC11, HCFC123, HCFC123 et HCFC141b. Les résultats ont montré que le coefficient de performance (COP) d'une pompe à chaleur à condensation
optimisée à trois étages de type non split était supérieure de 25 à 42 % à celle d'une pompe à chaleur monoétagée classique. L'augmentation du COP obtenue variait selon les frigorigènes étudiés ; elle était surtout fonction de la diminution de la température moyenne entre le frigorigène et l'eau dans les condenseurs, donnant lieu à une irreversibilité thermodynamique diminuée. Pour la pompe à chaleur à trois étages, le COP plus élevé a été obtenu lorsque la superficie de condensation totale était distribuée de façon, uniforme à travers les trois condenseurs. Cependant, pour la pompe à chaleur biétagée, la distribution optimale de la superficie totale du condenseur variait selon les frigorigènes utilisés. Pour le système à trois étages, la répartition de l'eau de refroidissement afin d'alimenter les sous-refroidisseurs à moyenne et à haute pression augmentait davantage le COP. Lorsque l'eau de refroidissement des sous-refroidisseurs à moyenne et à haute pression représentait 10% de l'eau de condensation totale, le COP optimal obtenu était supérieur d'environ 11% à celui des systèmes non « splits » pour le système de pompe à chaleur à 3 étages.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/S0140-7007(99)00083-3</doi><tpages>12</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0140-7007 |
ispartof | International journal of refrigeration, 2000-11, Vol.23 (7), p.528-539 |
issn | 0140-7007 1879-2081 |
language | eng |
recordid | cdi_proquest_miscellaneous_746166976 |
source | Access via ScienceDirect (Elsevier) |
subjects | Applied sciences Calcul Calculation Chlorofluorocarbons Condensation Cooling water Cycle frigorifique Devices using thermal energy Energy Energy. Thermal use of fuels Exact sciences and technology Fluorocarbons Heat pump Heat pump systems Heat pumps Multistage system Pompe à chaleur Refrigerating cycle Système polyétagé |
title | A study on the performance of multi-stage condensation heat pumps |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T20%3A17%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20study%20on%20the%20performance%20of%20multi-stage%20condensation%20heat%20pumps&rft.jtitle=International%20journal%20of%20refrigeration&rft.au=Jung,%20Dongsoo&rft.date=2000-11-01&rft.volume=23&rft.issue=7&rft.spage=528&rft.epage=539&rft.pages=528-539&rft.issn=0140-7007&rft.eissn=1879-2081&rft.coden=IJRFDI&rft_id=info:doi/10.1016/S0140-7007(99)00083-3&rft_dat=%3Cproquest_cross%3E746166976%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=746166976&rft_id=info:pmid/&rft_els_id=S0140700799000833&rfr_iscdi=true |