Quality assurance of an image guided intracranial stereotactic positioning system for radiosurgery treatment with helical tomotherapy

The aim of this work was to determine the accuracy and precision of stereotactic localization and treatment delivery using a helical tomotherapy based stereotactic radiosurgery (SRS) system. A tomotherapy specific radiosurgery workflow was designed that exploits the system’s on board megavotage CT (...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of neuro-oncology 2010-06, Vol.98 (2), p.277-285
Hauptverfasser: Soisson, Emilie T., Hardcastle, Nick, Tomé, Wolfgang A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 285
container_issue 2
container_start_page 277
container_title Journal of neuro-oncology
container_volume 98
creator Soisson, Emilie T.
Hardcastle, Nick
Tomé, Wolfgang A.
description The aim of this work was to determine the accuracy and precision of stereotactic localization and treatment delivery using a helical tomotherapy based stereotactic radiosurgery (SRS) system. A tomotherapy specific radiosurgery workflow was designed that exploits the system’s on board megavotage CT (MVCT) imaging system so that it not only provides a pre-treatment volumetric verification image that can be used for stereotactic localization, eliminating the need for a patient-frame based coordinate system, but also supplies the treatment planning image. Using an imaging guidance based intracranial stereotactic positioning system, a head ring and tabletop docking device are used only for fixation, while image guidance is used for localization. Due to the unconventional workflow, a methodology for determining the localization accuracy was developed and results were compared to other linear accelerator based radiosurgery systems. In this work, the localization error using volumetric localization was found to be 0.45 mm ± 0.17 mm, indicating a localization precision of 0.3 mm within a 95% confidence interval. In addition, procedures for testing the delivery accuracy of the Tomotherapy system are described. Results show that the accuracy of the delivery can be verified to within ±1 voxel dimension. These results are well within conventional SRS tolerances and compare favorably to other linear accelerator based techniques.
doi_str_mv 10.1007/s11060-010-0227-4
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_744620147</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2057643481</sourcerecordid><originalsourceid>FETCH-LOGICAL-c402t-2b86d5419dc77a978e50d301f2c5cc9f7ceff4b6193ccdcf61cf3e54b90f59183</originalsourceid><addsrcrecordid>eNqFkc2KFDEUhYMoTjv6AG4kuHFVevNX6VrK4M_AgAgK7kI6ddOdoSppkxRDPYDvbZoeFQRxEbI43z25OYeQ5wxeMwD9pjAGPXTA2uFcd_IB2TClRaeFFg_JBlivOzXIbxfkSSm3ACC1YI_JBQcFatjChvz4vNgp1JXaUpZso0OaPLWRhtnuke6XMOJIQ6zZuiYHO9FSMWOq1tXg6DGVUEOKIe5pWZs0U58yzXYMqRnuMa-0ZrR1xljpXagHesApuOZT05zqAbM9rk_JI2-ngs_u70vy9f27L1cfu5tPH66v3t50TgKvHd9t-1FJNoxOazvoLSoYBTDPnXJu8Nqh93LXs0E4NzrfM-cFKrkbwKuBbcUleXX2Peb0fcFSzRyKw2myEdNSjJay58BaSv8lheBDD7Jv5Mu_yNu05Ni-YYRuy4IQskHsDLmcSsnozTG3hPNqGJhTl-bcpWldmlOX5jTz4t542c04_p74VV4D-BkoTYot6j8v_9v1JxpArO4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>375410334</pqid></control><display><type>article</type><title>Quality assurance of an image guided intracranial stereotactic positioning system for radiosurgery treatment with helical tomotherapy</title><source>MEDLINE</source><source>SpringerNature Journals</source><creator>Soisson, Emilie T. ; Hardcastle, Nick ; Tomé, Wolfgang A.</creator><creatorcontrib>Soisson, Emilie T. ; Hardcastle, Nick ; Tomé, Wolfgang A.</creatorcontrib><description>The aim of this work was to determine the accuracy and precision of stereotactic localization and treatment delivery using a helical tomotherapy based stereotactic radiosurgery (SRS) system. A tomotherapy specific radiosurgery workflow was designed that exploits the system’s on board megavotage CT (MVCT) imaging system so that it not only provides a pre-treatment volumetric verification image that can be used for stereotactic localization, eliminating the need for a patient-frame based coordinate system, but also supplies the treatment planning image. Using an imaging guidance based intracranial stereotactic positioning system, a head ring and tabletop docking device are used only for fixation, while image guidance is used for localization. Due to the unconventional workflow, a methodology for determining the localization accuracy was developed and results were compared to other linear accelerator based radiosurgery systems. In this work, the localization error using volumetric localization was found to be 0.45 mm ± 0.17 mm, indicating a localization precision of 0.3 mm within a 95% confidence interval. In addition, procedures for testing the delivery accuracy of the Tomotherapy system are described. Results show that the accuracy of the delivery can be verified to within ±1 voxel dimension. These results are well within conventional SRS tolerances and compare favorably to other linear accelerator based techniques.</description><identifier>ISSN: 0167-594X</identifier><identifier>EISSN: 1573-7373</identifier><identifier>DOI: 10.1007/s11060-010-0227-4</identifier><identifier>PMID: 20505980</identifier><language>eng</language><publisher>Boston: Springer US</publisher><subject>Brain Neoplasms - surgery ; Clinical Study/Patient Study ; Equipment Design ; Humans ; Medicine ; Medicine &amp; Public Health ; Neurology ; Oncology ; Patient Positioning - instrumentation ; Patient Positioning - methods ; Quality Control ; Radiosurgery - instrumentation ; Radiosurgery - methods ; Radiotherapy Planning, Computer-Assisted - instrumentation ; Radiotherapy Planning, Computer-Assisted - methods ; Stereotaxic Techniques - instrumentation ; Tomography, X-Ray Computed - instrumentation ; Tomography, X-Ray Computed - methods</subject><ispartof>Journal of neuro-oncology, 2010-06, Vol.98 (2), p.277-285</ispartof><rights>Springer Science+Business Media, LLC. 2010</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c402t-2b86d5419dc77a978e50d301f2c5cc9f7ceff4b6193ccdcf61cf3e54b90f59183</citedby><cites>FETCH-LOGICAL-c402t-2b86d5419dc77a978e50d301f2c5cc9f7ceff4b6193ccdcf61cf3e54b90f59183</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s11060-010-0227-4$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s11060-010-0227-4$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20505980$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Soisson, Emilie T.</creatorcontrib><creatorcontrib>Hardcastle, Nick</creatorcontrib><creatorcontrib>Tomé, Wolfgang A.</creatorcontrib><title>Quality assurance of an image guided intracranial stereotactic positioning system for radiosurgery treatment with helical tomotherapy</title><title>Journal of neuro-oncology</title><addtitle>J Neurooncol</addtitle><addtitle>J Neurooncol</addtitle><description>The aim of this work was to determine the accuracy and precision of stereotactic localization and treatment delivery using a helical tomotherapy based stereotactic radiosurgery (SRS) system. A tomotherapy specific radiosurgery workflow was designed that exploits the system’s on board megavotage CT (MVCT) imaging system so that it not only provides a pre-treatment volumetric verification image that can be used for stereotactic localization, eliminating the need for a patient-frame based coordinate system, but also supplies the treatment planning image. Using an imaging guidance based intracranial stereotactic positioning system, a head ring and tabletop docking device are used only for fixation, while image guidance is used for localization. Due to the unconventional workflow, a methodology for determining the localization accuracy was developed and results were compared to other linear accelerator based radiosurgery systems. In this work, the localization error using volumetric localization was found to be 0.45 mm ± 0.17 mm, indicating a localization precision of 0.3 mm within a 95% confidence interval. In addition, procedures for testing the delivery accuracy of the Tomotherapy system are described. Results show that the accuracy of the delivery can be verified to within ±1 voxel dimension. These results are well within conventional SRS tolerances and compare favorably to other linear accelerator based techniques.</description><subject>Brain Neoplasms - surgery</subject><subject>Clinical Study/Patient Study</subject><subject>Equipment Design</subject><subject>Humans</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Neurology</subject><subject>Oncology</subject><subject>Patient Positioning - instrumentation</subject><subject>Patient Positioning - methods</subject><subject>Quality Control</subject><subject>Radiosurgery - instrumentation</subject><subject>Radiosurgery - methods</subject><subject>Radiotherapy Planning, Computer-Assisted - instrumentation</subject><subject>Radiotherapy Planning, Computer-Assisted - methods</subject><subject>Stereotaxic Techniques - instrumentation</subject><subject>Tomography, X-Ray Computed - instrumentation</subject><subject>Tomography, X-Ray Computed - methods</subject><issn>0167-594X</issn><issn>1573-7373</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><recordid>eNqFkc2KFDEUhYMoTjv6AG4kuHFVevNX6VrK4M_AgAgK7kI6ddOdoSppkxRDPYDvbZoeFQRxEbI43z25OYeQ5wxeMwD9pjAGPXTA2uFcd_IB2TClRaeFFg_JBlivOzXIbxfkSSm3ACC1YI_JBQcFatjChvz4vNgp1JXaUpZso0OaPLWRhtnuke6XMOJIQ6zZuiYHO9FSMWOq1tXg6DGVUEOKIe5pWZs0U58yzXYMqRnuMa-0ZrR1xljpXagHesApuOZT05zqAbM9rk_JI2-ngs_u70vy9f27L1cfu5tPH66v3t50TgKvHd9t-1FJNoxOazvoLSoYBTDPnXJu8Nqh93LXs0E4NzrfM-cFKrkbwKuBbcUleXX2Peb0fcFSzRyKw2myEdNSjJay58BaSv8lheBDD7Jv5Mu_yNu05Ni-YYRuy4IQskHsDLmcSsnozTG3hPNqGJhTl-bcpWldmlOX5jTz4t542c04_p74VV4D-BkoTYot6j8v_9v1JxpArO4</recordid><startdate>20100601</startdate><enddate>20100601</enddate><creator>Soisson, Emilie T.</creator><creator>Hardcastle, Nick</creator><creator>Tomé, Wolfgang A.</creator><general>Springer US</general><general>Springer Nature B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7TK</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8C1</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope></search><sort><creationdate>20100601</creationdate><title>Quality assurance of an image guided intracranial stereotactic positioning system for radiosurgery treatment with helical tomotherapy</title><author>Soisson, Emilie T. ; Hardcastle, Nick ; Tomé, Wolfgang A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c402t-2b86d5419dc77a978e50d301f2c5cc9f7ceff4b6193ccdcf61cf3e54b90f59183</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Brain Neoplasms - surgery</topic><topic>Clinical Study/Patient Study</topic><topic>Equipment Design</topic><topic>Humans</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Neurology</topic><topic>Oncology</topic><topic>Patient Positioning - instrumentation</topic><topic>Patient Positioning - methods</topic><topic>Quality Control</topic><topic>Radiosurgery - instrumentation</topic><topic>Radiosurgery - methods</topic><topic>Radiotherapy Planning, Computer-Assisted - instrumentation</topic><topic>Radiotherapy Planning, Computer-Assisted - methods</topic><topic>Stereotaxic Techniques - instrumentation</topic><topic>Tomography, X-Ray Computed - instrumentation</topic><topic>Tomography, X-Ray Computed - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Soisson, Emilie T.</creatorcontrib><creatorcontrib>Hardcastle, Nick</creatorcontrib><creatorcontrib>Tomé, Wolfgang A.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Neurosciences Abstracts</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Public Health Database</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of neuro-oncology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Soisson, Emilie T.</au><au>Hardcastle, Nick</au><au>Tomé, Wolfgang A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Quality assurance of an image guided intracranial stereotactic positioning system for radiosurgery treatment with helical tomotherapy</atitle><jtitle>Journal of neuro-oncology</jtitle><stitle>J Neurooncol</stitle><addtitle>J Neurooncol</addtitle><date>2010-06-01</date><risdate>2010</risdate><volume>98</volume><issue>2</issue><spage>277</spage><epage>285</epage><pages>277-285</pages><issn>0167-594X</issn><eissn>1573-7373</eissn><abstract>The aim of this work was to determine the accuracy and precision of stereotactic localization and treatment delivery using a helical tomotherapy based stereotactic radiosurgery (SRS) system. A tomotherapy specific radiosurgery workflow was designed that exploits the system’s on board megavotage CT (MVCT) imaging system so that it not only provides a pre-treatment volumetric verification image that can be used for stereotactic localization, eliminating the need for a patient-frame based coordinate system, but also supplies the treatment planning image. Using an imaging guidance based intracranial stereotactic positioning system, a head ring and tabletop docking device are used only for fixation, while image guidance is used for localization. Due to the unconventional workflow, a methodology for determining the localization accuracy was developed and results were compared to other linear accelerator based radiosurgery systems. In this work, the localization error using volumetric localization was found to be 0.45 mm ± 0.17 mm, indicating a localization precision of 0.3 mm within a 95% confidence interval. In addition, procedures for testing the delivery accuracy of the Tomotherapy system are described. Results show that the accuracy of the delivery can be verified to within ±1 voxel dimension. These results are well within conventional SRS tolerances and compare favorably to other linear accelerator based techniques.</abstract><cop>Boston</cop><pub>Springer US</pub><pmid>20505980</pmid><doi>10.1007/s11060-010-0227-4</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0167-594X
ispartof Journal of neuro-oncology, 2010-06, Vol.98 (2), p.277-285
issn 0167-594X
1573-7373
language eng
recordid cdi_proquest_miscellaneous_744620147
source MEDLINE; SpringerNature Journals
subjects Brain Neoplasms - surgery
Clinical Study/Patient Study
Equipment Design
Humans
Medicine
Medicine & Public Health
Neurology
Oncology
Patient Positioning - instrumentation
Patient Positioning - methods
Quality Control
Radiosurgery - instrumentation
Radiosurgery - methods
Radiotherapy Planning, Computer-Assisted - instrumentation
Radiotherapy Planning, Computer-Assisted - methods
Stereotaxic Techniques - instrumentation
Tomography, X-Ray Computed - instrumentation
Tomography, X-Ray Computed - methods
title Quality assurance of an image guided intracranial stereotactic positioning system for radiosurgery treatment with helical tomotherapy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T02%3A24%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Quality%20assurance%20of%20an%20image%20guided%20intracranial%20stereotactic%20positioning%20system%20for%20radiosurgery%20treatment%20with%20helical%20tomotherapy&rft.jtitle=Journal%20of%20neuro-oncology&rft.au=Soisson,%20Emilie%20T.&rft.date=2010-06-01&rft.volume=98&rft.issue=2&rft.spage=277&rft.epage=285&rft.pages=277-285&rft.issn=0167-594X&rft.eissn=1573-7373&rft_id=info:doi/10.1007/s11060-010-0227-4&rft_dat=%3Cproquest_cross%3E2057643481%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=375410334&rft_id=info:pmid/20505980&rfr_iscdi=true