Axial Stiffness of Retention Pins in Human Dentin

Axial deflections of pins, anchored in specimens of human dentin by five different procedures, were measured by a specially constructed apparatus to an accuracy of 0.1 μ. Axial stiffness values calculated from these measurements were found to be significantly different for different methods of ancho...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of dental research 1979-03, Vol.58 (3), p.1055-1059
Hauptverfasser: Dhuru, V.B., McLachlan, K., Kasloff, Z.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!