A medical robot for needle placement therapy in liver cancer
Hepatocellular carcinoma (HCC) is the second most common malignancy in China. As microwave ablation (MWA) is an effective method for liver cancer, a robotic surgical system with ultrasound-directed was designed to assist surgeons on positioning the needles. This robotic system includes a surgical ro...
Gespeichert in:
Veröffentlicht in: | Journal of Zhejiang University. A. Science 2010-04, Vol.11 (4), p.263-269 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 269 |
---|---|
container_issue | 4 |
container_start_page | 263 |
container_title | Journal of Zhejiang University. A. Science |
container_volume | 11 |
creator | Duan, Xing-guang Bian, Gui-bin Zhao, Hong-hua Wang, Xing-tao Huang, Qiang |
description | Hepatocellular carcinoma (HCC) is the second most common malignancy in China. As microwave ablation (MWA) is an effective method for liver cancer, a robotic surgical system with ultrasound-directed was designed to assist surgeons on positioning the needles. This robotic system includes a surgical robot with 5 degrees of freedom, a workstation for path-planning and image processing, a conventional 2D ultrasound device, and an electromagnetic (EM) tracking system. Surgery space, clinical operation requirements and optimal mechanical structure are the key factors to be considered in designing a medical robot suitable for use by surgeons. Based on the mechanics of the needle placement robot, we have conducted detailed kinematic analysis, including a combined numerical algorithm and coordinate mapping. Finally, the feasibility of the needle placement robot has been validated by experiment. |
doi_str_mv | 10.1631/jzus.a1000040 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_743690059</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>33422083</cqvip_id><sourcerecordid>743690059</sourcerecordid><originalsourceid>FETCH-LOGICAL-c401t-da636f132d0ed8bcf5e492e0a185aac7ff5adcff7b7a64bd5963a48e25530b6d3</originalsourceid><addsrcrecordid>eNp1kL1PwzAQxS0EEqUwslssTCl2HNuJxFJVfEmVWEBisy7OuU1JnNROkcpfT6p25ZZ3w-_d6T1CbjmbcSX4w-Z3F2fA2TgZOyMTnqs04VrL83FXWiRSya9LchXjhjGpmdIT8jinLVa1hYaGruwG6rpAPWLVIO0bsNiiH-iwxgD9ntaeNvUPBmrBWwzX5MJBE_HmpFPy-fz0sXhNlu8vb4v5MrEZ40NSgRLKcZFWDKu8tE5iVqTIgOcSwGrnJFTWOV1qUFlZyUIJyHJMpRSsVJWYkvvj3T502x3GwbR1tNg04LHbRaMzoYoxUjGSyZG0oYsxoDN9qFsIe8OZOZRkDiWZ-amkkZ8d-ThyfoXBbLpd8GOYfw13pwfrzq-2o8eUYL9d3aARIktTlgvxB21gdg4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>743690059</pqid></control><display><type>article</type><title>A medical robot for needle placement therapy in liver cancer</title><source>Alma/SFX Local Collection</source><source>SpringerLink Journals - AutoHoldings</source><creator>Duan, Xing-guang ; Bian, Gui-bin ; Zhao, Hong-hua ; Wang, Xing-tao ; Huang, Qiang</creator><creatorcontrib>Duan, Xing-guang ; Bian, Gui-bin ; Zhao, Hong-hua ; Wang, Xing-tao ; Huang, Qiang</creatorcontrib><description>Hepatocellular carcinoma (HCC) is the second most common malignancy in China. As microwave ablation (MWA) is an effective method for liver cancer, a robotic surgical system with ultrasound-directed was designed to assist surgeons on positioning the needles. This robotic system includes a surgical robot with 5 degrees of freedom, a workstation for path-planning and image processing, a conventional 2D ultrasound device, and an electromagnetic (EM) tracking system. Surgery space, clinical operation requirements and optimal mechanical structure are the key factors to be considered in designing a medical robot suitable for use by surgeons. Based on the mechanics of the needle placement robot, we have conducted detailed kinematic analysis, including a combined numerical algorithm and coordinate mapping. Finally, the feasibility of the needle placement robot has been validated by experiment.</description><identifier>ISSN: 1673-565X</identifier><identifier>EISSN: 1862-1775</identifier><identifier>DOI: 10.1631/jzus.a1000040</identifier><language>eng</language><publisher>Heidelberg: SP Zhejiang University Press</publisher><subject>Civil Engineering ; Classical and Continuum Physics ; Engineering ; Industrial Chemistry/Chemical Engineering ; Mechanical Engineering</subject><ispartof>Journal of Zhejiang University. A. Science, 2010-04, Vol.11 (4), p.263-269</ispartof><rights>Zhejiang University and Springer-Verlag Berlin Heidelberg 2010</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c401t-da636f132d0ed8bcf5e492e0a185aac7ff5adcff7b7a64bd5963a48e25530b6d3</citedby><cites>FETCH-LOGICAL-c401t-da636f132d0ed8bcf5e492e0a185aac7ff5adcff7b7a64bd5963a48e25530b6d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/88140X/88140X.jpg</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1631/jzus.A1000040$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1631/jzus.A1000040$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,776,780,27903,27904,41467,42536,51297</link.rule.ids></links><search><creatorcontrib>Duan, Xing-guang</creatorcontrib><creatorcontrib>Bian, Gui-bin</creatorcontrib><creatorcontrib>Zhao, Hong-hua</creatorcontrib><creatorcontrib>Wang, Xing-tao</creatorcontrib><creatorcontrib>Huang, Qiang</creatorcontrib><title>A medical robot for needle placement therapy in liver cancer</title><title>Journal of Zhejiang University. A. Science</title><addtitle>J. Zhejiang Univ. Sci. A</addtitle><addtitle>Journal of Zhejiang University Science</addtitle><description>Hepatocellular carcinoma (HCC) is the second most common malignancy in China. As microwave ablation (MWA) is an effective method for liver cancer, a robotic surgical system with ultrasound-directed was designed to assist surgeons on positioning the needles. This robotic system includes a surgical robot with 5 degrees of freedom, a workstation for path-planning and image processing, a conventional 2D ultrasound device, and an electromagnetic (EM) tracking system. Surgery space, clinical operation requirements and optimal mechanical structure are the key factors to be considered in designing a medical robot suitable for use by surgeons. Based on the mechanics of the needle placement robot, we have conducted detailed kinematic analysis, including a combined numerical algorithm and coordinate mapping. Finally, the feasibility of the needle placement robot has been validated by experiment.</description><subject>Civil Engineering</subject><subject>Classical and Continuum Physics</subject><subject>Engineering</subject><subject>Industrial Chemistry/Chemical Engineering</subject><subject>Mechanical Engineering</subject><issn>1673-565X</issn><issn>1862-1775</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNp1kL1PwzAQxS0EEqUwslssTCl2HNuJxFJVfEmVWEBisy7OuU1JnNROkcpfT6p25ZZ3w-_d6T1CbjmbcSX4w-Z3F2fA2TgZOyMTnqs04VrL83FXWiRSya9LchXjhjGpmdIT8jinLVa1hYaGruwG6rpAPWLVIO0bsNiiH-iwxgD9ntaeNvUPBmrBWwzX5MJBE_HmpFPy-fz0sXhNlu8vb4v5MrEZ40NSgRLKcZFWDKu8tE5iVqTIgOcSwGrnJFTWOV1qUFlZyUIJyHJMpRSsVJWYkvvj3T502x3GwbR1tNg04LHbRaMzoYoxUjGSyZG0oYsxoDN9qFsIe8OZOZRkDiWZ-amkkZ8d-ThyfoXBbLpd8GOYfw13pwfrzq-2o8eUYL9d3aARIktTlgvxB21gdg4</recordid><startdate>20100401</startdate><enddate>20100401</enddate><creator>Duan, Xing-guang</creator><creator>Bian, Gui-bin</creator><creator>Zhao, Hong-hua</creator><creator>Wang, Xing-tao</creator><creator>Huang, Qiang</creator><general>SP Zhejiang University Press</general><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>W92</scope><scope>~WA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>7SP</scope><scope>7SR</scope><scope>7TB</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>FR3</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope></search><sort><creationdate>20100401</creationdate><title>A medical robot for needle placement therapy in liver cancer</title><author>Duan, Xing-guang ; Bian, Gui-bin ; Zhao, Hong-hua ; Wang, Xing-tao ; Huang, Qiang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c401t-da636f132d0ed8bcf5e492e0a185aac7ff5adcff7b7a64bd5963a48e25530b6d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Civil Engineering</topic><topic>Classical and Continuum Physics</topic><topic>Engineering</topic><topic>Industrial Chemistry/Chemical Engineering</topic><topic>Mechanical Engineering</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Duan, Xing-guang</creatorcontrib><creatorcontrib>Bian, Gui-bin</creatorcontrib><creatorcontrib>Zhao, Hong-hua</creatorcontrib><creatorcontrib>Wang, Xing-tao</creatorcontrib><creatorcontrib>Huang, Qiang</creatorcontrib><collection>中文科技期刊数据库</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库-工程技术</collection><collection>中文科技期刊数据库- 镜像站点</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><jtitle>Journal of Zhejiang University. A. Science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Duan, Xing-guang</au><au>Bian, Gui-bin</au><au>Zhao, Hong-hua</au><au>Wang, Xing-tao</au><au>Huang, Qiang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A medical robot for needle placement therapy in liver cancer</atitle><jtitle>Journal of Zhejiang University. A. Science</jtitle><stitle>J. Zhejiang Univ. Sci. A</stitle><addtitle>Journal of Zhejiang University Science</addtitle><date>2010-04-01</date><risdate>2010</risdate><volume>11</volume><issue>4</issue><spage>263</spage><epage>269</epage><pages>263-269</pages><issn>1673-565X</issn><eissn>1862-1775</eissn><abstract>Hepatocellular carcinoma (HCC) is the second most common malignancy in China. As microwave ablation (MWA) is an effective method for liver cancer, a robotic surgical system with ultrasound-directed was designed to assist surgeons on positioning the needles. This robotic system includes a surgical robot with 5 degrees of freedom, a workstation for path-planning and image processing, a conventional 2D ultrasound device, and an electromagnetic (EM) tracking system. Surgery space, clinical operation requirements and optimal mechanical structure are the key factors to be considered in designing a medical robot suitable for use by surgeons. Based on the mechanics of the needle placement robot, we have conducted detailed kinematic analysis, including a combined numerical algorithm and coordinate mapping. Finally, the feasibility of the needle placement robot has been validated by experiment.</abstract><cop>Heidelberg</cop><pub>SP Zhejiang University Press</pub><doi>10.1631/jzus.a1000040</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1673-565X |
ispartof | Journal of Zhejiang University. A. Science, 2010-04, Vol.11 (4), p.263-269 |
issn | 1673-565X 1862-1775 |
language | eng |
recordid | cdi_proquest_miscellaneous_743690059 |
source | Alma/SFX Local Collection; SpringerLink Journals - AutoHoldings |
subjects | Civil Engineering Classical and Continuum Physics Engineering Industrial Chemistry/Chemical Engineering Mechanical Engineering |
title | A medical robot for needle placement therapy in liver cancer |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T12%3A11%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20medical%20robot%20for%20needle%20placement%20therapy%20in%20liver%20cancer&rft.jtitle=Journal%20of%20Zhejiang%20University.%20A.%20Science&rft.au=Duan,%20Xing-guang&rft.date=2010-04-01&rft.volume=11&rft.issue=4&rft.spage=263&rft.epage=269&rft.pages=263-269&rft.issn=1673-565X&rft.eissn=1862-1775&rft_id=info:doi/10.1631/jzus.a1000040&rft_dat=%3Cproquest_cross%3E743690059%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=743690059&rft_id=info:pmid/&rft_cqvip_id=33422083&rfr_iscdi=true |