A morphological and an electrochemical characterization of a pvd titanium film deposited upon an AISI 316L stainless steel

من أجل تحسين التلاؤم البيولوجي للفولاذ الأوستنيتي (AISI 316L) المقاوم للصدأ, تم إيداع التيتانيوم عليه من خلال عملية فيزيائية بخارية مع تغيير معالم التجربة. و قد تم التحقيق في سطح المواد الحيوية الجديدة من قبل التقنيات AFM, XRD و SEM. كذلك تم إجراء اختبارات ميكيانيكية و كهركيميائية, و ذلك لأن هذه هي...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Arabian journal for science and engineering. Section B, Engineering Engineering, 2009-12, Vol.34 (2C(s)), p.7-17
Hauptverfasser: al-Hachi, Yunus, Atman, Fuad, Daimellah, Abd al-Rahman, Hilal, Fath
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 17
container_issue 2C(s)
container_start_page 7
container_title Arabian journal for science and engineering. Section B, Engineering
container_volume 34
creator al-Hachi, Yunus
Atman, Fuad
Daimellah, Abd al-Rahman
Hilal, Fath
description من أجل تحسين التلاؤم البيولوجي للفولاذ الأوستنيتي (AISI 316L) المقاوم للصدأ, تم إيداع التيتانيوم عليه من خلال عملية فيزيائية بخارية مع تغيير معالم التجربة. و قد تم التحقيق في سطح المواد الحيوية الجديدة من قبل التقنيات AFM, XRD و SEM. كذلك تم إجراء اختبارات ميكيانيكية و كهركيميائية, و ذلك لأن هذه هي الخصائص اللازمة لزراعة هذه المواد الحيوية. و قد ركزنا – في هذا العمل – على العلاقة بين عوامل شكل السطح (خشونة, حدوث مسامية, شعرية البلورية) و خصائص السطح. و تبدو القشرة متجانسة, لكن تتأثر المعلمة RMS بمدة عملية الترسيب الفيزيائي البخاري. و يظهر تبلور التيتانيوم مرتبطا بخشونة السطح و تركيب الفولاذ الأوستنيتي المقاوم للصدأ. و ترجع المقاومة الأفضل للتآكل للالتصاق الجيد للقشرة. In order to improve the biocompatibility of austenitic stainless steel (AISI 316L), titanium has been deposited upon it by a physical vapour process. Depositions have been carried out by varying experiment parameters. The new biomaterial surface has been investigated by AFM, EDX, and SEM. Further, mechanical and electrochemical tests were performed, because these are the required properties for such biomaterial implants. In this work, we focused on the relationship between shape surface factors (roughness, porosity occurrence, crystalline lattice) and surface properties. The film seems to be homogeneous, but its RMS parameter is affected by the duration of the PVD process. Crystallization of titanium is probably linked to the stainless steel surface roughness and its microstructure. The better corrosion resistance is due to the good adhesion of the columnar deposited film.
format Article
fullrecord <record><control><sourceid>proquest_emare</sourceid><recordid>TN_cdi_proquest_miscellaneous_743603429</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>743603429</sourcerecordid><originalsourceid>FETCH-LOGICAL-e209t-5ae5c45f5e22ca9ba7c404268ee9c78d8bc3e3143e522eb62939bd298a34fef73</originalsourceid><addsrcrecordid>eNotjE1LxDAYhIMouK7-BCE3T4Xmo21yXBY_FhY8qOfyNn3jRtKmJqng_nqLu4dhHoaZuSArzjQrJFfskqyYYLpQJa-uyU1KX2VZM9WIFTlu6BDidAg-fDoDnsLYL6Lo0eQYzAGH_9gcIILJGN0RsgsjDZYCnX56ml2G0c0Dtc4PtMcpJJexp_O0tJanze5tRwWr9zRlcKPHlBZC9LfkyoJPeHf2Nfl4enzfvhT71-fddrMvkJc6FxVgZWRlK-TcgO6gMbKUvFaI2jSqV50RKJgUWHGOXc210F3PtQIhLdpGrMnD6XeK4XvGlNvBJYPew4hhTm0jRV0KuezW5P7UxAEiWmin6Bb6bUWlNJfiD7udZu0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>743603429</pqid></control><display><type>article</type><title>A morphological and an electrochemical characterization of a pvd titanium film deposited upon an AISI 316L stainless steel</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>al-Hachi, Yunus ; Atman, Fuad ; Daimellah, Abd al-Rahman ; Hilal, Fath</creator><creatorcontrib>al-Hachi, Yunus ; Atman, Fuad ; Daimellah, Abd al-Rahman ; Hilal, Fath</creatorcontrib><description>من أجل تحسين التلاؤم البيولوجي للفولاذ الأوستنيتي (AISI 316L) المقاوم للصدأ, تم إيداع التيتانيوم عليه من خلال عملية فيزيائية بخارية مع تغيير معالم التجربة. و قد تم التحقيق في سطح المواد الحيوية الجديدة من قبل التقنيات AFM, XRD و SEM. كذلك تم إجراء اختبارات ميكيانيكية و كهركيميائية, و ذلك لأن هذه هي الخصائص اللازمة لزراعة هذه المواد الحيوية. و قد ركزنا – في هذا العمل – على العلاقة بين عوامل شكل السطح (خشونة, حدوث مسامية, شعرية البلورية) و خصائص السطح. و تبدو القشرة متجانسة, لكن تتأثر المعلمة RMS بمدة عملية الترسيب الفيزيائي البخاري. و يظهر تبلور التيتانيوم مرتبطا بخشونة السطح و تركيب الفولاذ الأوستنيتي المقاوم للصدأ. و ترجع المقاومة الأفضل للتآكل للالتصاق الجيد للقشرة. In order to improve the biocompatibility of austenitic stainless steel (AISI 316L), titanium has been deposited upon it by a physical vapour process. Depositions have been carried out by varying experiment parameters. The new biomaterial surface has been investigated by AFM, EDX, and SEM. Further, mechanical and electrochemical tests were performed, because these are the required properties for such biomaterial implants. In this work, we focused on the relationship between shape surface factors (roughness, porosity occurrence, crystalline lattice) and surface properties. The film seems to be homogeneous, but its RMS parameter is affected by the duration of the PVD process. Crystallization of titanium is probably linked to the stainless steel surface roughness and its microstructure. The better corrosion resistance is due to the good adhesion of the columnar deposited film.</description><identifier>ISSN: 1319-8025</identifier><identifier>EISSN: 2191-4281</identifier><language>eng</language><publisher>Dhahran, Saudi Arabia: King Fahd University of Petroleum and Minerals</publisher><subject>Analysis ; Corrosion ; Stainless steel ; Surfaces (Technology) ; Titanium thin films ; الفولاذ المقاوم للصدأ</subject><ispartof>Arabian journal for science and engineering. Section B, Engineering, 2009-12, Vol.34 (2C(s)), p.7-17</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids></links><search><creatorcontrib>al-Hachi, Yunus</creatorcontrib><creatorcontrib>Atman, Fuad</creatorcontrib><creatorcontrib>Daimellah, Abd al-Rahman</creatorcontrib><creatorcontrib>Hilal, Fath</creatorcontrib><title>A morphological and an electrochemical characterization of a pvd titanium film deposited upon an AISI 316L stainless steel</title><title>Arabian journal for science and engineering. Section B, Engineering</title><description>من أجل تحسين التلاؤم البيولوجي للفولاذ الأوستنيتي (AISI 316L) المقاوم للصدأ, تم إيداع التيتانيوم عليه من خلال عملية فيزيائية بخارية مع تغيير معالم التجربة. و قد تم التحقيق في سطح المواد الحيوية الجديدة من قبل التقنيات AFM, XRD و SEM. كذلك تم إجراء اختبارات ميكيانيكية و كهركيميائية, و ذلك لأن هذه هي الخصائص اللازمة لزراعة هذه المواد الحيوية. و قد ركزنا – في هذا العمل – على العلاقة بين عوامل شكل السطح (خشونة, حدوث مسامية, شعرية البلورية) و خصائص السطح. و تبدو القشرة متجانسة, لكن تتأثر المعلمة RMS بمدة عملية الترسيب الفيزيائي البخاري. و يظهر تبلور التيتانيوم مرتبطا بخشونة السطح و تركيب الفولاذ الأوستنيتي المقاوم للصدأ. و ترجع المقاومة الأفضل للتآكل للالتصاق الجيد للقشرة. In order to improve the biocompatibility of austenitic stainless steel (AISI 316L), titanium has been deposited upon it by a physical vapour process. Depositions have been carried out by varying experiment parameters. The new biomaterial surface has been investigated by AFM, EDX, and SEM. Further, mechanical and electrochemical tests were performed, because these are the required properties for such biomaterial implants. In this work, we focused on the relationship between shape surface factors (roughness, porosity occurrence, crystalline lattice) and surface properties. The film seems to be homogeneous, but its RMS parameter is affected by the duration of the PVD process. Crystallization of titanium is probably linked to the stainless steel surface roughness and its microstructure. The better corrosion resistance is due to the good adhesion of the columnar deposited film.</description><subject>Analysis</subject><subject>Corrosion</subject><subject>Stainless steel</subject><subject>Surfaces (Technology)</subject><subject>Titanium thin films</subject><subject>الفولاذ المقاوم للصدأ</subject><issn>1319-8025</issn><issn>2191-4281</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNotjE1LxDAYhIMouK7-BCE3T4Xmo21yXBY_FhY8qOfyNn3jRtKmJqng_nqLu4dhHoaZuSArzjQrJFfskqyYYLpQJa-uyU1KX2VZM9WIFTlu6BDidAg-fDoDnsLYL6Lo0eQYzAGH_9gcIILJGN0RsgsjDZYCnX56ml2G0c0Dtc4PtMcpJJexp_O0tJanze5tRwWr9zRlcKPHlBZC9LfkyoJPeHf2Nfl4enzfvhT71-fddrMvkJc6FxVgZWRlK-TcgO6gMbKUvFaI2jSqV50RKJgUWHGOXc210F3PtQIhLdpGrMnD6XeK4XvGlNvBJYPew4hhTm0jRV0KuezW5P7UxAEiWmin6Bb6bUWlNJfiD7udZu0</recordid><startdate>20091201</startdate><enddate>20091201</enddate><creator>al-Hachi, Yunus</creator><creator>Atman, Fuad</creator><creator>Daimellah, Abd al-Rahman</creator><creator>Hilal, Fath</creator><general>King Fahd University of Petroleum and Minerals</general><scope>AACQA</scope><scope>ADJCN</scope><scope>ADLFG</scope><scope>AHFXO</scope><scope>7SE</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>JG9</scope><scope>KR7</scope></search><sort><creationdate>20091201</creationdate><title>A morphological and an electrochemical characterization of a pvd titanium film deposited upon an AISI 316L stainless steel</title><author>al-Hachi, Yunus ; Atman, Fuad ; Daimellah, Abd al-Rahman ; Hilal, Fath</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-e209t-5ae5c45f5e22ca9ba7c404268ee9c78d8bc3e3143e522eb62939bd298a34fef73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Analysis</topic><topic>Corrosion</topic><topic>Stainless steel</topic><topic>Surfaces (Technology)</topic><topic>Titanium thin films</topic><topic>الفولاذ المقاوم للصدأ</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>al-Hachi, Yunus</creatorcontrib><creatorcontrib>Atman, Fuad</creatorcontrib><creatorcontrib>Daimellah, Abd al-Rahman</creatorcontrib><creatorcontrib>Hilal, Fath</creatorcontrib><collection>بنك معلومات "معرفة" لدراسات العلوم العسكرية والأمنية - e-Marefa Military &amp; Security Database</collection><collection>الدوريات العلمية والإحصائية - e-Marefa Academic and Statistical Periodicals</collection><collection>قاعدة الدراسات الاستراتيجية والشؤون الدولية - e-Marefa Strategic Studies &amp; International Affairs</collection><collection>معرفة - المحتوى العربي الأكاديمي المتكامل - e-Marefa Academic Complete</collection><collection>Corrosion Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Arabian journal for science and engineering. Section B, Engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>al-Hachi, Yunus</au><au>Atman, Fuad</au><au>Daimellah, Abd al-Rahman</au><au>Hilal, Fath</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A morphological and an electrochemical characterization of a pvd titanium film deposited upon an AISI 316L stainless steel</atitle><jtitle>Arabian journal for science and engineering. Section B, Engineering</jtitle><date>2009-12-01</date><risdate>2009</risdate><volume>34</volume><issue>2C(s)</issue><spage>7</spage><epage>17</epage><pages>7-17</pages><issn>1319-8025</issn><eissn>2191-4281</eissn><abstract>من أجل تحسين التلاؤم البيولوجي للفولاذ الأوستنيتي (AISI 316L) المقاوم للصدأ, تم إيداع التيتانيوم عليه من خلال عملية فيزيائية بخارية مع تغيير معالم التجربة. و قد تم التحقيق في سطح المواد الحيوية الجديدة من قبل التقنيات AFM, XRD و SEM. كذلك تم إجراء اختبارات ميكيانيكية و كهركيميائية, و ذلك لأن هذه هي الخصائص اللازمة لزراعة هذه المواد الحيوية. و قد ركزنا – في هذا العمل – على العلاقة بين عوامل شكل السطح (خشونة, حدوث مسامية, شعرية البلورية) و خصائص السطح. و تبدو القشرة متجانسة, لكن تتأثر المعلمة RMS بمدة عملية الترسيب الفيزيائي البخاري. و يظهر تبلور التيتانيوم مرتبطا بخشونة السطح و تركيب الفولاذ الأوستنيتي المقاوم للصدأ. و ترجع المقاومة الأفضل للتآكل للالتصاق الجيد للقشرة. In order to improve the biocompatibility of austenitic stainless steel (AISI 316L), titanium has been deposited upon it by a physical vapour process. Depositions have been carried out by varying experiment parameters. The new biomaterial surface has been investigated by AFM, EDX, and SEM. Further, mechanical and electrochemical tests were performed, because these are the required properties for such biomaterial implants. In this work, we focused on the relationship between shape surface factors (roughness, porosity occurrence, crystalline lattice) and surface properties. The film seems to be homogeneous, but its RMS parameter is affected by the duration of the PVD process. Crystallization of titanium is probably linked to the stainless steel surface roughness and its microstructure. The better corrosion resistance is due to the good adhesion of the columnar deposited film.</abstract><cop>Dhahran, Saudi Arabia</cop><pub>King Fahd University of Petroleum and Minerals</pub><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1319-8025
ispartof Arabian journal for science and engineering. Section B, Engineering, 2009-12, Vol.34 (2C(s)), p.7-17
issn 1319-8025
2191-4281
language eng
recordid cdi_proquest_miscellaneous_743603429
source EZB-FREE-00999 freely available EZB journals
subjects Analysis
Corrosion
Stainless steel
Surfaces (Technology)
Titanium thin films
الفولاذ المقاوم للصدأ
title A morphological and an electrochemical characterization of a pvd titanium film deposited upon an AISI 316L stainless steel
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T05%3A56%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_emare&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20morphological%20and%20an%20electrochemical%20characterization%20of%20a%20pvd%20titanium%20film%20deposited%20upon%20an%20AISI%20316L%20stainless%20steel&rft.jtitle=Arabian%20journal%20for%20science%20and%20engineering.%20Section%20B,%20Engineering&rft.au=al-Hachi,%20Yunus&rft.date=2009-12-01&rft.volume=34&rft.issue=2C(s)&rft.spage=7&rft.epage=17&rft.pages=7-17&rft.issn=1319-8025&rft.eissn=2191-4281&rft_id=info:doi/&rft_dat=%3Cproquest_emare%3E743603429%3C/proquest_emare%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=743603429&rft_id=info:pmid/&rfr_iscdi=true