Relationship between Length of Time and Contamination in Open Intravenous Solutions
This study investigated rate of contamination in simulated in-use intravenous solutions to obtain data from which to recommend a standard time period for the administration of intravenous solutions. Although the Center for Disease Control and many medical institutions have recommended that all bottl...
Gespeichert in:
Veröffentlicht in: | Nursing research (New York) 1978-11, Vol.27 (6), p.372-374 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 374 |
---|---|
container_issue | 6 |
container_start_page | 372 |
container_title | Nursing research (New York) |
container_volume | 27 |
creator | Amonsen, Sharon Gren, Janet E |
description | This study investigated rate of contamination in simulated in-use intravenous solutions to obtain data from which to recommend a standard time period for the administration of intravenous solutions. Although the Center for Disease Control and many medical institutions have recommended that all bottles of in-use intravenous solutions be changed every 24 hours, there are no published data to support the 24-hour standard. In this study, samples were drawn from 80 bottles of Ringerʼs Lactale solution at predetermined time intervals over 48 hours and cultured on blood agar plates to determine rate of contamination. A low incidence of intravenous solution contamination was found at all time periods. Of 430 total samples, only 12 (2.8 percent) were contaminated. Results of this study did not indicate a significant relationship between time and contamination of simulated in-use intravenous solutions. Therefore, contamination that does occur within 48 hours in intravenous solutions must be introduced from some exogenous source. Further research is required to elucidate exogenous sources of contamination. In the meantime, it can be concluded, the 24-hour standard is adequate to protect against contamination that would occur solely from preparation of the intravenous solution for administration. |
doi_str_mv | 10.1097/00006199-197811000-00009 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_74318251</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>74318251</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3549-92c4a46645603218470ff55c20caad86cb07f4d532a1f4af2b7f265a2addc2573</originalsourceid><addsrcrecordid>eNp1kU1PxCAQhonxa139Bx44easCBVqOZuPHJpuYuOuZ0BZsldK1UDf-e9ntuje5EGaeeWfmBQCI0S1GIrtD8XAsRIJFlmMcX8k2JI7ABLM0T0ROs2MwQYiIhDNOzsGF9x-RoJykZ-CUMEyomIDlq7YqNJ3zdbOGhQ4brR1caPceatgZuGpaDZWr4KxzQbWN28GwcfBlHcG5C7361q4bPFx2dtgpXYITo6zXV_t7Ct4eH1az52Tx8jSf3S-SMmVUJIKUVFHOKeMoJTgOjIxhrCSoVKrKeVmgzNCKpURhQ5UhRWYIZ4qoqioJy9IpuBl11333NWgfZNv4UlurnI4DyYymOI-LRjAfwbLvvO-1keu-aVX_IzGSWzvln53yYOcuJGLp9b7HULS6OhSO_sU0HdObzgbd-087bHQva61sqOV_n5T-Ava8f7k</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>74318251</pqid></control><display><type>article</type><title>Relationship between Length of Time and Contamination in Open Intravenous Solutions</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>Amonsen, Sharon ; Gren, Janet E</creator><creatorcontrib>Amonsen, Sharon ; Gren, Janet E</creatorcontrib><description>This study investigated rate of contamination in simulated in-use intravenous solutions to obtain data from which to recommend a standard time period for the administration of intravenous solutions. Although the Center for Disease Control and many medical institutions have recommended that all bottles of in-use intravenous solutions be changed every 24 hours, there are no published data to support the 24-hour standard. In this study, samples were drawn from 80 bottles of Ringerʼs Lactale solution at predetermined time intervals over 48 hours and cultured on blood agar plates to determine rate of contamination. A low incidence of intravenous solution contamination was found at all time periods. Of 430 total samples, only 12 (2.8 percent) were contaminated. Results of this study did not indicate a significant relationship between time and contamination of simulated in-use intravenous solutions. Therefore, contamination that does occur within 48 hours in intravenous solutions must be introduced from some exogenous source. Further research is required to elucidate exogenous sources of contamination. In the meantime, it can be concluded, the 24-hour standard is adequate to protect against contamination that would occur solely from preparation of the intravenous solution for administration.</description><identifier>ISSN: 0029-6562</identifier><identifier>EISSN: 1538-9847</identifier><identifier>DOI: 10.1097/00006199-197811000-00009</identifier><identifier>PMID: 251249</identifier><language>eng</language><publisher>United States: Lippincott-Raven Publishers</publisher><subject>Drug Contamination ; Evaluation Studies as Topic ; Infusions, Parenteral ; Nursing ; Time Factors</subject><ispartof>Nursing research (New York), 1978-11, Vol.27 (6), p.372-374</ispartof><rights>Lippincott-Raven Publishers.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3549-92c4a46645603218470ff55c20caad86cb07f4d532a1f4af2b7f265a2addc2573</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/251249$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Amonsen, Sharon</creatorcontrib><creatorcontrib>Gren, Janet E</creatorcontrib><title>Relationship between Length of Time and Contamination in Open Intravenous Solutions</title><title>Nursing research (New York)</title><addtitle>Nurs Res</addtitle><description>This study investigated rate of contamination in simulated in-use intravenous solutions to obtain data from which to recommend a standard time period for the administration of intravenous solutions. Although the Center for Disease Control and many medical institutions have recommended that all bottles of in-use intravenous solutions be changed every 24 hours, there are no published data to support the 24-hour standard. In this study, samples were drawn from 80 bottles of Ringerʼs Lactale solution at predetermined time intervals over 48 hours and cultured on blood agar plates to determine rate of contamination. A low incidence of intravenous solution contamination was found at all time periods. Of 430 total samples, only 12 (2.8 percent) were contaminated. Results of this study did not indicate a significant relationship between time and contamination of simulated in-use intravenous solutions. Therefore, contamination that does occur within 48 hours in intravenous solutions must be introduced from some exogenous source. Further research is required to elucidate exogenous sources of contamination. In the meantime, it can be concluded, the 24-hour standard is adequate to protect against contamination that would occur solely from preparation of the intravenous solution for administration.</description><subject>Drug Contamination</subject><subject>Evaluation Studies as Topic</subject><subject>Infusions, Parenteral</subject><subject>Nursing</subject><subject>Time Factors</subject><issn>0029-6562</issn><issn>1538-9847</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1978</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kU1PxCAQhonxa139Bx44easCBVqOZuPHJpuYuOuZ0BZsldK1UDf-e9ntuje5EGaeeWfmBQCI0S1GIrtD8XAsRIJFlmMcX8k2JI7ABLM0T0ROs2MwQYiIhDNOzsGF9x-RoJykZ-CUMEyomIDlq7YqNJ3zdbOGhQ4brR1caPceatgZuGpaDZWr4KxzQbWN28GwcfBlHcG5C7361q4bPFx2dtgpXYITo6zXV_t7Ct4eH1az52Tx8jSf3S-SMmVUJIKUVFHOKeMoJTgOjIxhrCSoVKrKeVmgzNCKpURhQ5UhRWYIZ4qoqioJy9IpuBl11333NWgfZNv4UlurnI4DyYymOI-LRjAfwbLvvO-1keu-aVX_IzGSWzvln53yYOcuJGLp9b7HULS6OhSO_sU0HdObzgbd-087bHQva61sqOV_n5T-Ava8f7k</recordid><startdate>197811</startdate><enddate>197811</enddate><creator>Amonsen, Sharon</creator><creator>Gren, Janet E</creator><general>Lippincott-Raven Publishers</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>197811</creationdate><title>Relationship between Length of Time and Contamination in Open Intravenous Solutions</title><author>Amonsen, Sharon ; Gren, Janet E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3549-92c4a46645603218470ff55c20caad86cb07f4d532a1f4af2b7f265a2addc2573</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1978</creationdate><topic>Drug Contamination</topic><topic>Evaluation Studies as Topic</topic><topic>Infusions, Parenteral</topic><topic>Nursing</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Amonsen, Sharon</creatorcontrib><creatorcontrib>Gren, Janet E</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Nursing research (New York)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Amonsen, Sharon</au><au>Gren, Janet E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Relationship between Length of Time and Contamination in Open Intravenous Solutions</atitle><jtitle>Nursing research (New York)</jtitle><addtitle>Nurs Res</addtitle><date>1978-11</date><risdate>1978</risdate><volume>27</volume><issue>6</issue><spage>372</spage><epage>374</epage><pages>372-374</pages><issn>0029-6562</issn><eissn>1538-9847</eissn><abstract>This study investigated rate of contamination in simulated in-use intravenous solutions to obtain data from which to recommend a standard time period for the administration of intravenous solutions. Although the Center for Disease Control and many medical institutions have recommended that all bottles of in-use intravenous solutions be changed every 24 hours, there are no published data to support the 24-hour standard. In this study, samples were drawn from 80 bottles of Ringerʼs Lactale solution at predetermined time intervals over 48 hours and cultured on blood agar plates to determine rate of contamination. A low incidence of intravenous solution contamination was found at all time periods. Of 430 total samples, only 12 (2.8 percent) were contaminated. Results of this study did not indicate a significant relationship between time and contamination of simulated in-use intravenous solutions. Therefore, contamination that does occur within 48 hours in intravenous solutions must be introduced from some exogenous source. Further research is required to elucidate exogenous sources of contamination. In the meantime, it can be concluded, the 24-hour standard is adequate to protect against contamination that would occur solely from preparation of the intravenous solution for administration.</abstract><cop>United States</cop><pub>Lippincott-Raven Publishers</pub><pmid>251249</pmid><doi>10.1097/00006199-197811000-00009</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0029-6562 |
ispartof | Nursing research (New York), 1978-11, Vol.27 (6), p.372-374 |
issn | 0029-6562 1538-9847 |
language | eng |
recordid | cdi_proquest_miscellaneous_74318251 |
source | MEDLINE; Journals@Ovid Complete |
subjects | Drug Contamination Evaluation Studies as Topic Infusions, Parenteral Nursing Time Factors |
title | Relationship between Length of Time and Contamination in Open Intravenous Solutions |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T06%3A29%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Relationship%20between%20Length%20of%20Time%20and%20Contamination%20in%20Open%20Intravenous%20Solutions&rft.jtitle=Nursing%20research%20(New%20York)&rft.au=Amonsen,%20Sharon&rft.date=1978-11&rft.volume=27&rft.issue=6&rft.spage=372&rft.epage=374&rft.pages=372-374&rft.issn=0029-6562&rft.eissn=1538-9847&rft_id=info:doi/10.1097/00006199-197811000-00009&rft_dat=%3Cproquest_cross%3E74318251%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=74318251&rft_id=info:pmid/251249&rfr_iscdi=true |