Energy use and management in production of entrees in hospital food service systems
Extract: Energy required for process stages of production of beef loaves was determined for 5 simulated hospital food service systems. Three were on-premise systems: conventional, cook/chill, and cook/freeze. Two were assembly/serve systems: thaw/heat/serve and heat/serve. Meters were used to monito...
Gespeichert in:
Veröffentlicht in: | Journal of the American Dietetic Association 1982-08, Vol.81 (2), p.145-151 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 151 |
---|---|
container_issue | 2 |
container_start_page | 145 |
container_title | Journal of the American Dietetic Association |
container_volume | 81 |
creator | McProud, L.M David, B.D |
description | Extract: Energy required for process stages of production of beef loaves was determined for 5 simulated hospital food service systems. Three were on-premise systems: conventional, cook/chill, and cook/freeze. Two were assembly/serve systems: thaw/heat/serve and heat/serve. Meters were used to monitor actual energy, and apportioned energy was based on percentage usable equipment space occupied by the beef loaves. Theoretical energy was calculated on the basis of temperature change, product mass, and heat capacity. The cook/chill and cook/freeze systems required more energy than the conventional system; results varied according to measure used. (author) |
doi_str_mv | 10.1016/S0002-8223(21)38757-0 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_74167907</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>74167907</sourcerecordid><originalsourceid>FETCH-LOGICAL-c352t-ca98c1746e8829152d3473ac07c69cae8d2265c4d47fdaf72c9e7d1fdea5470e3</originalsourceid><addsrcrecordid>eNp9kE9v2zAMxYWiQ5em-whFdRrWg1dKskz5OATZHyDADlnPgibRqQvbyiS7QL79nCbosSeCfO-RxI-xWwFfBYjqYQsAsjBSqi9S3CuDGgu4YAth0BRKI1yyxZvlI7vO-XluQQu4YlcowADigm3XA6XdgU-ZuBsC793gdtTTMPJ24PsUw-THNg48NnweJqJ8FJ5i3rej63gTY-CZ0kvriedDHqnPN-xD47pMn851yR6_r_-sfhab3z9-rb5tCq-0HAvvauMFlhUZI2uhZVAlKucBfVV7RyZIWWlfhhKb4BqUviYMognkdIlAask-n_bOb_6bKI-2b7OnrnMDxSlbLEWFNeBs1CejTzHnRI3dp7Z36WAF2CNM-wrTHklZKewrTAtz7vZ8YPrbU3hLnenN-t1Jb1y0bpfabB-3EoQCOa-rQb3jEHVdaZDqP4xFgqg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>74167907</pqid></control><display><type>article</type><title>Energy use and management in production of entrees in hospital food service systems</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>McProud, L.M ; David, B.D</creator><creatorcontrib>McProud, L.M ; David, B.D</creatorcontrib><description>Extract: Energy required for process stages of production of beef loaves was determined for 5 simulated hospital food service systems. Three were on-premise systems: conventional, cook/chill, and cook/freeze. Two were assembly/serve systems: thaw/heat/serve and heat/serve. Meters were used to monitor actual energy, and apportioned energy was based on percentage usable equipment space occupied by the beef loaves. Theoretical energy was calculated on the basis of temperature change, product mass, and heat capacity. The cook/chill and cook/freeze systems required more energy than the conventional system; results varied according to measure used. (author)</description><identifier>ISSN: 0002-8223</identifier><identifier>EISSN: 1878-3570</identifier><identifier>DOI: 10.1016/S0002-8223(21)38757-0</identifier><identifier>PMID: 7108077</identifier><language>eng</language><publisher>United States</publisher><subject>Animals ; beef ; bioenergy ; Cattle ; Conservation of Energy Resources - methods ; Conservation of Natural Resources - methods ; Electricity - economics ; energy conservation ; energy resources ; Food Handling - economics ; Food Preservation - economics ; food production ; food service ; food service management ; Food Service, Hospital - economics ; Fossil Fuels ; Frozen Foods ; hospital food service ; Meat - economics ; Microwaves ; natural resources ; Refrigeration - economics ; Thermodynamics</subject><ispartof>Journal of the American Dietetic Association, 1982-08, Vol.81 (2), p.145-151</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c352t-ca98c1746e8829152d3473ac07c69cae8d2265c4d47fdaf72c9e7d1fdea5470e3</citedby><cites>FETCH-LOGICAL-c352t-ca98c1746e8829152d3473ac07c69cae8d2265c4d47fdaf72c9e7d1fdea5470e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7108077$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>McProud, L.M</creatorcontrib><creatorcontrib>David, B.D</creatorcontrib><title>Energy use and management in production of entrees in hospital food service systems</title><title>Journal of the American Dietetic Association</title><addtitle>J Am Diet Assoc</addtitle><description>Extract: Energy required for process stages of production of beef loaves was determined for 5 simulated hospital food service systems. Three were on-premise systems: conventional, cook/chill, and cook/freeze. Two were assembly/serve systems: thaw/heat/serve and heat/serve. Meters were used to monitor actual energy, and apportioned energy was based on percentage usable equipment space occupied by the beef loaves. Theoretical energy was calculated on the basis of temperature change, product mass, and heat capacity. The cook/chill and cook/freeze systems required more energy than the conventional system; results varied according to measure used. (author)</description><subject>Animals</subject><subject>beef</subject><subject>bioenergy</subject><subject>Cattle</subject><subject>Conservation of Energy Resources - methods</subject><subject>Conservation of Natural Resources - methods</subject><subject>Electricity - economics</subject><subject>energy conservation</subject><subject>energy resources</subject><subject>Food Handling - economics</subject><subject>Food Preservation - economics</subject><subject>food production</subject><subject>food service</subject><subject>food service management</subject><subject>Food Service, Hospital - economics</subject><subject>Fossil Fuels</subject><subject>Frozen Foods</subject><subject>hospital food service</subject><subject>Meat - economics</subject><subject>Microwaves</subject><subject>natural resources</subject><subject>Refrigeration - economics</subject><subject>Thermodynamics</subject><issn>0002-8223</issn><issn>1878-3570</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1982</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE9v2zAMxYWiQ5em-whFdRrWg1dKskz5OATZHyDADlnPgibRqQvbyiS7QL79nCbosSeCfO-RxI-xWwFfBYjqYQsAsjBSqi9S3CuDGgu4YAth0BRKI1yyxZvlI7vO-XluQQu4YlcowADigm3XA6XdgU-ZuBsC793gdtTTMPJ24PsUw-THNg48NnweJqJ8FJ5i3rej63gTY-CZ0kvriedDHqnPN-xD47pMn851yR6_r_-sfhab3z9-rb5tCq-0HAvvauMFlhUZI2uhZVAlKucBfVV7RyZIWWlfhhKb4BqUviYMognkdIlAask-n_bOb_6bKI-2b7OnrnMDxSlbLEWFNeBs1CejTzHnRI3dp7Z36WAF2CNM-wrTHklZKewrTAtz7vZ8YPrbU3hLnenN-t1Jb1y0bpfabB-3EoQCOa-rQb3jEHVdaZDqP4xFgqg</recordid><startdate>198208</startdate><enddate>198208</enddate><creator>McProud, L.M</creator><creator>David, B.D</creator><scope>FBQ</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>198208</creationdate><title>Energy use and management in production of entrees in hospital food service systems</title><author>McProud, L.M ; David, B.D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c352t-ca98c1746e8829152d3473ac07c69cae8d2265c4d47fdaf72c9e7d1fdea5470e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1982</creationdate><topic>Animals</topic><topic>beef</topic><topic>bioenergy</topic><topic>Cattle</topic><topic>Conservation of Energy Resources - methods</topic><topic>Conservation of Natural Resources - methods</topic><topic>Electricity - economics</topic><topic>energy conservation</topic><topic>energy resources</topic><topic>Food Handling - economics</topic><topic>Food Preservation - economics</topic><topic>food production</topic><topic>food service</topic><topic>food service management</topic><topic>Food Service, Hospital - economics</topic><topic>Fossil Fuels</topic><topic>Frozen Foods</topic><topic>hospital food service</topic><topic>Meat - economics</topic><topic>Microwaves</topic><topic>natural resources</topic><topic>Refrigeration - economics</topic><topic>Thermodynamics</topic><toplevel>online_resources</toplevel><creatorcontrib>McProud, L.M</creatorcontrib><creatorcontrib>David, B.D</creatorcontrib><collection>AGRIS</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the American Dietetic Association</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>McProud, L.M</au><au>David, B.D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Energy use and management in production of entrees in hospital food service systems</atitle><jtitle>Journal of the American Dietetic Association</jtitle><addtitle>J Am Diet Assoc</addtitle><date>1982-08</date><risdate>1982</risdate><volume>81</volume><issue>2</issue><spage>145</spage><epage>151</epage><pages>145-151</pages><issn>0002-8223</issn><eissn>1878-3570</eissn><abstract>Extract: Energy required for process stages of production of beef loaves was determined for 5 simulated hospital food service systems. Three were on-premise systems: conventional, cook/chill, and cook/freeze. Two were assembly/serve systems: thaw/heat/serve and heat/serve. Meters were used to monitor actual energy, and apportioned energy was based on percentage usable equipment space occupied by the beef loaves. Theoretical energy was calculated on the basis of temperature change, product mass, and heat capacity. The cook/chill and cook/freeze systems required more energy than the conventional system; results varied according to measure used. (author)</abstract><cop>United States</cop><pmid>7108077</pmid><doi>10.1016/S0002-8223(21)38757-0</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0002-8223 |
ispartof | Journal of the American Dietetic Association, 1982-08, Vol.81 (2), p.145-151 |
issn | 0002-8223 1878-3570 |
language | eng |
recordid | cdi_proquest_miscellaneous_74167907 |
source | MEDLINE; ScienceDirect Journals (5 years ago - present) |
subjects | Animals beef bioenergy Cattle Conservation of Energy Resources - methods Conservation of Natural Resources - methods Electricity - economics energy conservation energy resources Food Handling - economics Food Preservation - economics food production food service food service management Food Service, Hospital - economics Fossil Fuels Frozen Foods hospital food service Meat - economics Microwaves natural resources Refrigeration - economics Thermodynamics |
title | Energy use and management in production of entrees in hospital food service systems |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T16%3A37%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Energy%20use%20and%20management%20in%20production%20of%20entrees%20in%20hospital%20food%20service%20systems&rft.jtitle=Journal%20of%20the%20American%20Dietetic%20Association&rft.au=McProud,%20L.M&rft.date=1982-08&rft.volume=81&rft.issue=2&rft.spage=145&rft.epage=151&rft.pages=145-151&rft.issn=0002-8223&rft.eissn=1878-3570&rft_id=info:doi/10.1016/S0002-8223(21)38757-0&rft_dat=%3Cproquest_cross%3E74167907%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=74167907&rft_id=info:pmid/7108077&rfr_iscdi=true |