Technical note-test instructions for the technical testing of mono-functional myoelectrically-controlled prosthetic hands. A proposal

To get an acceptable standard of prostheses and orthoses in Sweden, the Swedish Institute for the Handicapped is testing this group of aids. One important part of the work is to draw up test instructions. In response to a request from the Swedish Institute for the Handicapped, the Laboratory of Reha...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Prosthetics and orthotics international 1982-04, Vol.6 (1), p.41-42
Hauptverfasser: Ingvarsson, B., Karlsson, I., Ottosson, L-G., Thyberg, M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 42
container_issue 1
container_start_page 41
container_title Prosthetics and orthotics international
container_volume 6
creator Ingvarsson, B.
Karlsson, I.
Ottosson, L-G.
Thyberg, M.
description To get an acceptable standard of prostheses and orthoses in Sweden, the Swedish Institute for the Handicapped is testing this group of aids. One important part of the work is to draw up test instructions. In response to a request from the Swedish Institute for the Handicapped, the Laboratory of Rehabilitation Engineering at the University Hospital of Linköping in Sweden, has suggested instructions for the technical testing of mono-functional myoelectrically controlled prosthetic hands. These test instructions contain different inspection and control factors which are important for the function of the prosthetic hand.
doi_str_mv 10.3109/03093648209167739
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_74064456</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.3109_03093648209167739</sage_id><sourcerecordid>74064456</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3459-3c8ed6997f0b1f5bd8efeac72e7465d31f530f1e39d6a13ba412ddf623047a9d3</originalsourceid><addsrcrecordid>eNqNkUFPIyEYhslGU6u7P2APm3DyNhXKDJR4MsZdTZp4cc8TCh-dMQxUYA79Af5vGdt4MTGeSL73eV_4XhD6TcmCUSKvCCOS8Xq1JJJyIZj8geZU1LyiTcNO0HzSqwLwM3Se0jMhTEhJZmgmiJCUkjl6fQLd-V4rh33IUGVIGfc-5Tjq3AefsA0R5w5w_gAnpvdbHCwegg-VHf07W6RhH8CBznEC3b7SwecYnAODdzGkkpN7jTvlTVrgm2m2C0m5n-jUKpfg1_G8QP__3j3d3lfrx38PtzfrSrO6KZvoFRgupbBkQ22zMSuwoLRYQtm5MazMGLEUmDRcUbZRNV0aY_mSkVooadgFujzklotfxrJGO_RJg3PKQxhTK2rC67rhBaQHUJdXpwi23cV-UHHfUtJO1befqi-eP8fwcTOA-XAcuy764qAntYX2OYyxNJa-DLw-GHpfPmFQHSiXO63it9xvwxmiGA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>74064456</pqid></control><display><type>article</type><title>Technical note-test instructions for the technical testing of mono-functional myoelectrically-controlled prosthetic hands. A proposal</title><source>MEDLINE</source><source>Taylor &amp; Francis:Master (3349 titles)</source><creator>Ingvarsson, B. ; Karlsson, I. ; Ottosson, L-G. ; Thyberg, M.</creator><creatorcontrib>Ingvarsson, B. ; Karlsson, I. ; Ottosson, L-G. ; Thyberg, M.</creatorcontrib><description>To get an acceptable standard of prostheses and orthoses in Sweden, the Swedish Institute for the Handicapped is testing this group of aids. One important part of the work is to draw up test instructions. In response to a request from the Swedish Institute for the Handicapped, the Laboratory of Rehabilitation Engineering at the University Hospital of Linköping in Sweden, has suggested instructions for the technical testing of mono-functional myoelectrically controlled prosthetic hands. These test instructions contain different inspection and control factors which are important for the function of the prosthetic hand.</description><identifier>ISSN: 0309-3646</identifier><identifier>EISSN: 1746-1553</identifier><identifier>DOI: 10.3109/03093648209167739</identifier><identifier>PMID: 7079110</identifier><language>eng</language><publisher>London, England: Informa UK Ltd</publisher><subject>Amputation - rehabilitation ; Artificial Limbs - standards ; Biomedical Engineering - standards ; Electric Power Supplies ; Hand ; Humans</subject><ispartof>Prosthetics and orthotics international, 1982-04, Vol.6 (1), p.41-42</ispartof><rights>1982 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted 1982</rights><rights>1982 SAGE Publications</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3459-3c8ed6997f0b1f5bd8efeac72e7465d31f530f1e39d6a13ba412ddf623047a9d3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.tandfonline.com/doi/pdf/10.3109/03093648209167739$$EPDF$$P50$$Ginformahealthcare$$H</linktopdf><linktohtml>$$Uhttps://www.tandfonline.com/doi/full/10.3109/03093648209167739$$EHTML$$P50$$Ginformahealthcare$$H</linktohtml><link.rule.ids>314,780,784,27923,27924,61220,61401</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7079110$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ingvarsson, B.</creatorcontrib><creatorcontrib>Karlsson, I.</creatorcontrib><creatorcontrib>Ottosson, L-G.</creatorcontrib><creatorcontrib>Thyberg, M.</creatorcontrib><title>Technical note-test instructions for the technical testing of mono-functional myoelectrically-controlled prosthetic hands. A proposal</title><title>Prosthetics and orthotics international</title><addtitle>Prosthet Orthot Int</addtitle><description>To get an acceptable standard of prostheses and orthoses in Sweden, the Swedish Institute for the Handicapped is testing this group of aids. One important part of the work is to draw up test instructions. In response to a request from the Swedish Institute for the Handicapped, the Laboratory of Rehabilitation Engineering at the University Hospital of Linköping in Sweden, has suggested instructions for the technical testing of mono-functional myoelectrically controlled prosthetic hands. These test instructions contain different inspection and control factors which are important for the function of the prosthetic hand.</description><subject>Amputation - rehabilitation</subject><subject>Artificial Limbs - standards</subject><subject>Biomedical Engineering - standards</subject><subject>Electric Power Supplies</subject><subject>Hand</subject><subject>Humans</subject><issn>0309-3646</issn><issn>1746-1553</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1982</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNkUFPIyEYhslGU6u7P2APm3DyNhXKDJR4MsZdTZp4cc8TCh-dMQxUYA79Af5vGdt4MTGeSL73eV_4XhD6TcmCUSKvCCOS8Xq1JJJyIZj8geZU1LyiTcNO0HzSqwLwM3Se0jMhTEhJZmgmiJCUkjl6fQLd-V4rh33IUGVIGfc-5Tjq3AefsA0R5w5w_gAnpvdbHCwegg-VHf07W6RhH8CBznEC3b7SwecYnAODdzGkkpN7jTvlTVrgm2m2C0m5n-jUKpfg1_G8QP__3j3d3lfrx38PtzfrSrO6KZvoFRgupbBkQ22zMSuwoLRYQtm5MazMGLEUmDRcUbZRNV0aY_mSkVooadgFujzklotfxrJGO_RJg3PKQxhTK2rC67rhBaQHUJdXpwi23cV-UHHfUtJO1befqi-eP8fwcTOA-XAcuy764qAntYX2OYyxNJa-DLw-GHpfPmFQHSiXO63it9xvwxmiGA</recordid><startdate>198204</startdate><enddate>198204</enddate><creator>Ingvarsson, B.</creator><creator>Karlsson, I.</creator><creator>Ottosson, L-G.</creator><creator>Thyberg, M.</creator><general>Informa UK Ltd</general><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>198204</creationdate><title>Technical note-test instructions for the technical testing of mono-functional myoelectrically-controlled prosthetic hands. A proposal</title><author>Ingvarsson, B. ; Karlsson, I. ; Ottosson, L-G. ; Thyberg, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3459-3c8ed6997f0b1f5bd8efeac72e7465d31f530f1e39d6a13ba412ddf623047a9d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1982</creationdate><topic>Amputation - rehabilitation</topic><topic>Artificial Limbs - standards</topic><topic>Biomedical Engineering - standards</topic><topic>Electric Power Supplies</topic><topic>Hand</topic><topic>Humans</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ingvarsson, B.</creatorcontrib><creatorcontrib>Karlsson, I.</creatorcontrib><creatorcontrib>Ottosson, L-G.</creatorcontrib><creatorcontrib>Thyberg, M.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Prosthetics and orthotics international</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ingvarsson, B.</au><au>Karlsson, I.</au><au>Ottosson, L-G.</au><au>Thyberg, M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Technical note-test instructions for the technical testing of mono-functional myoelectrically-controlled prosthetic hands. A proposal</atitle><jtitle>Prosthetics and orthotics international</jtitle><addtitle>Prosthet Orthot Int</addtitle><date>1982-04</date><risdate>1982</risdate><volume>6</volume><issue>1</issue><spage>41</spage><epage>42</epage><pages>41-42</pages><issn>0309-3646</issn><eissn>1746-1553</eissn><abstract>To get an acceptable standard of prostheses and orthoses in Sweden, the Swedish Institute for the Handicapped is testing this group of aids. One important part of the work is to draw up test instructions. In response to a request from the Swedish Institute for the Handicapped, the Laboratory of Rehabilitation Engineering at the University Hospital of Linköping in Sweden, has suggested instructions for the technical testing of mono-functional myoelectrically controlled prosthetic hands. These test instructions contain different inspection and control factors which are important for the function of the prosthetic hand.</abstract><cop>London, England</cop><pub>Informa UK Ltd</pub><pmid>7079110</pmid><doi>10.3109/03093648209167739</doi><tpages>2</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0309-3646
ispartof Prosthetics and orthotics international, 1982-04, Vol.6 (1), p.41-42
issn 0309-3646
1746-1553
language eng
recordid cdi_proquest_miscellaneous_74064456
source MEDLINE; Taylor & Francis:Master (3349 titles)
subjects Amputation - rehabilitation
Artificial Limbs - standards
Biomedical Engineering - standards
Electric Power Supplies
Hand
Humans
title Technical note-test instructions for the technical testing of mono-functional myoelectrically-controlled prosthetic hands. A proposal
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T18%3A12%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Technical%20note-test%20instructions%20for%20the%20technical%20testing%20of%20mono-functional%20myoelectrically-controlled%20prosthetic%20hands.%20A%20proposal&rft.jtitle=Prosthetics%20and%20orthotics%20international&rft.au=Ingvarsson,%20B.&rft.date=1982-04&rft.volume=6&rft.issue=1&rft.spage=41&rft.epage=42&rft.pages=41-42&rft.issn=0309-3646&rft.eissn=1746-1553&rft_id=info:doi/10.3109/03093648209167739&rft_dat=%3Cproquest_cross%3E74064456%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=74064456&rft_id=info:pmid/7079110&rft_sage_id=10.3109_03093648209167739&rfr_iscdi=true