Accuracy and reproducibility of a quantitative electrophoresis of plasma lipoproteins: interlaboratory comparison and verification by ultracentrifugation

Fifty-three samples of sera from normal subjects and from patients with type IIa, IIb and IV hyperlipoproteinemia were shipped from Hannover to the collaborative laboratories in Vienna and Mannheim, which participated in the quantification of their lipoprotein fractions based on polyanion precipitat...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinica chimica acta 1981-11, Vol.116 (3), p.381-387
Hauptverfasser: Bojanovski, Dubo, Wippermann, Burkhard, Molinari, Ewald, Schuster, Jürgen, Canzler, Helmut
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 387
container_issue 3
container_start_page 381
container_title Clinica chimica acta
container_volume 116
creator Bojanovski, Dubo
Wippermann, Burkhard
Molinari, Ewald
Schuster, Jürgen
Canzler, Helmut
description Fifty-three samples of sera from normal subjects and from patients with type IIa, IIb and IV hyperlipoproteinemia were shipped from Hannover to the collaborative laboratories in Vienna and Mannheim, which participated in the quantification of their lipoprotein fractions based on polyanion precipitation of electrophoretically separated lipoproteins followed by densitometric measurement of alpha-, prebeta- and beta-lipoproteins. Total serum cholesterol and cholesterol calculated from quantified lipoprotein fractions were highly correlated, the correlation coefficients ranged between r = 0.93–0.98. Furthermore, we found a high concordance comparing the beta-, prebeta- and alpha-cholesterol with data obtained from lipoprotein fractionation and subsequent cholesterol measurement by ultracentrifugation. The obtained correlation coefficients were always higher than r = 0.91. High accuracy and reproducibility of the quantitative lipoprotein electrophoresis justify its recommendation for wide use in the field of clinical chemistry.
doi_str_mv 10.1016/0009-8981(81)90057-7
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73710712</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0009898181900577</els_id><sourcerecordid>73710712</sourcerecordid><originalsourceid>FETCH-LOGICAL-c272t-a267f6b3fb6477fe244ea848231fcc691cf314d0137722fc53692c03a6c3bf5d3</originalsourceid><addsrcrecordid>eNp9UU1rFTEUDaLU16f_QCEr0cXYfL1kxoVQirWFQje6DpnMjUYyk2mSeTA_xX9r3gddCoGQc8899-YchN5R8pkSKq8IIV3Tdi392NJPHSE71agXaENbxRsuOvYSbZ4pr9Flzn_qUxBJL9CF7MSuY2KD_l5buyRjV2ymASeYUxwW63sffFlxdNjgp8VMxRdT_B4wBLAlxfl3TJB9PjDmYPJocPBzrN0F_JS_YD8VSMH0MZkS04ptHGeTfI7TcdAeknfeVs0K9CteQqlLwFQqvPw6wm_QK2dChrfne4t-3n77cXPXPDx-v7-5fmgsU6w0hknlZM9dL4VSDpgQYFrRMk6dtbKj1nEqBkK5Uow5u-OyY5ZwIy3v3W7gW_ThpFuXf1ogFz36bCEEM0FcslZcUaIoq0RxItoUc07g9Jz8aNKqKdGHRPTBbn2wW9dzTKR2b9H7s_7SjzA8N50jqPWvpzrUT-49JJ2th8nC4FP1Wg_R_3_APxhpoAE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73710712</pqid></control><display><type>article</type><title>Accuracy and reproducibility of a quantitative electrophoresis of plasma lipoproteins: interlaboratory comparison and verification by ultracentrifugation</title><source>MEDLINE</source><source>ScienceDirect Freedom Collection (Elsevier)</source><creator>Bojanovski, Dubo ; Wippermann, Burkhard ; Molinari, Ewald ; Schuster, Jürgen ; Canzler, Helmut</creator><creatorcontrib>Bojanovski, Dubo ; Wippermann, Burkhard ; Molinari, Ewald ; Schuster, Jürgen ; Canzler, Helmut</creatorcontrib><description>Fifty-three samples of sera from normal subjects and from patients with type IIa, IIb and IV hyperlipoproteinemia were shipped from Hannover to the collaborative laboratories in Vienna and Mannheim, which participated in the quantification of their lipoprotein fractions based on polyanion precipitation of electrophoretically separated lipoproteins followed by densitometric measurement of alpha-, prebeta- and beta-lipoproteins. Total serum cholesterol and cholesterol calculated from quantified lipoprotein fractions were highly correlated, the correlation coefficients ranged between r = 0.93–0.98. Furthermore, we found a high concordance comparing the beta-, prebeta- and alpha-cholesterol with data obtained from lipoprotein fractionation and subsequent cholesterol measurement by ultracentrifugation. The obtained correlation coefficients were always higher than r = 0.91. High accuracy and reproducibility of the quantitative lipoprotein electrophoresis justify its recommendation for wide use in the field of clinical chemistry.</description><identifier>ISSN: 0009-8981</identifier><identifier>EISSN: 1873-3492</identifier><identifier>DOI: 10.1016/0009-8981(81)90057-7</identifier><identifier>PMID: 6945924</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Cholesterol - blood ; Cholesterol, HDL ; Cholesterol, LDL ; Cholesterol, VLDL ; Humans ; Hyperlipoproteinemias - blood ; Lipoproteins - blood ; Lipoproteins, HDL - blood ; Lipoproteins, LDL - blood ; Lipoproteins, VLDL - blood ; Quality Control</subject><ispartof>Clinica chimica acta, 1981-11, Vol.116 (3), p.381-387</ispartof><rights>1981</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c272t-a267f6b3fb6477fe244ea848231fcc691cf314d0137722fc53692c03a6c3bf5d3</citedby><cites>FETCH-LOGICAL-c272t-a267f6b3fb6477fe244ea848231fcc691cf314d0137722fc53692c03a6c3bf5d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/0009-8981(81)90057-7$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,27923,27924,45994</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/6945924$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bojanovski, Dubo</creatorcontrib><creatorcontrib>Wippermann, Burkhard</creatorcontrib><creatorcontrib>Molinari, Ewald</creatorcontrib><creatorcontrib>Schuster, Jürgen</creatorcontrib><creatorcontrib>Canzler, Helmut</creatorcontrib><title>Accuracy and reproducibility of a quantitative electrophoresis of plasma lipoproteins: interlaboratory comparison and verification by ultracentrifugation</title><title>Clinica chimica acta</title><addtitle>Clin Chim Acta</addtitle><description>Fifty-three samples of sera from normal subjects and from patients with type IIa, IIb and IV hyperlipoproteinemia were shipped from Hannover to the collaborative laboratories in Vienna and Mannheim, which participated in the quantification of their lipoprotein fractions based on polyanion precipitation of electrophoretically separated lipoproteins followed by densitometric measurement of alpha-, prebeta- and beta-lipoproteins. Total serum cholesterol and cholesterol calculated from quantified lipoprotein fractions were highly correlated, the correlation coefficients ranged between r = 0.93–0.98. Furthermore, we found a high concordance comparing the beta-, prebeta- and alpha-cholesterol with data obtained from lipoprotein fractionation and subsequent cholesterol measurement by ultracentrifugation. The obtained correlation coefficients were always higher than r = 0.91. High accuracy and reproducibility of the quantitative lipoprotein electrophoresis justify its recommendation for wide use in the field of clinical chemistry.</description><subject>Cholesterol - blood</subject><subject>Cholesterol, HDL</subject><subject>Cholesterol, LDL</subject><subject>Cholesterol, VLDL</subject><subject>Humans</subject><subject>Hyperlipoproteinemias - blood</subject><subject>Lipoproteins - blood</subject><subject>Lipoproteins, HDL - blood</subject><subject>Lipoproteins, LDL - blood</subject><subject>Lipoproteins, VLDL - blood</subject><subject>Quality Control</subject><issn>0009-8981</issn><issn>1873-3492</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1981</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9UU1rFTEUDaLU16f_QCEr0cXYfL1kxoVQirWFQje6DpnMjUYyk2mSeTA_xX9r3gddCoGQc8899-YchN5R8pkSKq8IIV3Tdi392NJPHSE71agXaENbxRsuOvYSbZ4pr9Flzn_qUxBJL9CF7MSuY2KD_l5buyRjV2ymASeYUxwW63sffFlxdNjgp8VMxRdT_B4wBLAlxfl3TJB9PjDmYPJocPBzrN0F_JS_YD8VSMH0MZkS04ptHGeTfI7TcdAeknfeVs0K9CteQqlLwFQqvPw6wm_QK2dChrfne4t-3n77cXPXPDx-v7-5fmgsU6w0hknlZM9dL4VSDpgQYFrRMk6dtbKj1nEqBkK5Uow5u-OyY5ZwIy3v3W7gW_ThpFuXf1ogFz36bCEEM0FcslZcUaIoq0RxItoUc07g9Jz8aNKqKdGHRPTBbn2wW9dzTKR2b9H7s_7SjzA8N50jqPWvpzrUT-49JJ2th8nC4FP1Wg_R_3_APxhpoAE</recordid><startdate>19811111</startdate><enddate>19811111</enddate><creator>Bojanovski, Dubo</creator><creator>Wippermann, Burkhard</creator><creator>Molinari, Ewald</creator><creator>Schuster, Jürgen</creator><creator>Canzler, Helmut</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19811111</creationdate><title>Accuracy and reproducibility of a quantitative electrophoresis of plasma lipoproteins: interlaboratory comparison and verification by ultracentrifugation</title><author>Bojanovski, Dubo ; Wippermann, Burkhard ; Molinari, Ewald ; Schuster, Jürgen ; Canzler, Helmut</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c272t-a267f6b3fb6477fe244ea848231fcc691cf314d0137722fc53692c03a6c3bf5d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1981</creationdate><topic>Cholesterol - blood</topic><topic>Cholesterol, HDL</topic><topic>Cholesterol, LDL</topic><topic>Cholesterol, VLDL</topic><topic>Humans</topic><topic>Hyperlipoproteinemias - blood</topic><topic>Lipoproteins - blood</topic><topic>Lipoproteins, HDL - blood</topic><topic>Lipoproteins, LDL - blood</topic><topic>Lipoproteins, VLDL - blood</topic><topic>Quality Control</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bojanovski, Dubo</creatorcontrib><creatorcontrib>Wippermann, Burkhard</creatorcontrib><creatorcontrib>Molinari, Ewald</creatorcontrib><creatorcontrib>Schuster, Jürgen</creatorcontrib><creatorcontrib>Canzler, Helmut</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Clinica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bojanovski, Dubo</au><au>Wippermann, Burkhard</au><au>Molinari, Ewald</au><au>Schuster, Jürgen</au><au>Canzler, Helmut</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Accuracy and reproducibility of a quantitative electrophoresis of plasma lipoproteins: interlaboratory comparison and verification by ultracentrifugation</atitle><jtitle>Clinica chimica acta</jtitle><addtitle>Clin Chim Acta</addtitle><date>1981-11-11</date><risdate>1981</risdate><volume>116</volume><issue>3</issue><spage>381</spage><epage>387</epage><pages>381-387</pages><issn>0009-8981</issn><eissn>1873-3492</eissn><abstract>Fifty-three samples of sera from normal subjects and from patients with type IIa, IIb and IV hyperlipoproteinemia were shipped from Hannover to the collaborative laboratories in Vienna and Mannheim, which participated in the quantification of their lipoprotein fractions based on polyanion precipitation of electrophoretically separated lipoproteins followed by densitometric measurement of alpha-, prebeta- and beta-lipoproteins. Total serum cholesterol and cholesterol calculated from quantified lipoprotein fractions were highly correlated, the correlation coefficients ranged between r = 0.93–0.98. Furthermore, we found a high concordance comparing the beta-, prebeta- and alpha-cholesterol with data obtained from lipoprotein fractionation and subsequent cholesterol measurement by ultracentrifugation. The obtained correlation coefficients were always higher than r = 0.91. High accuracy and reproducibility of the quantitative lipoprotein electrophoresis justify its recommendation for wide use in the field of clinical chemistry.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>6945924</pmid><doi>10.1016/0009-8981(81)90057-7</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0009-8981
ispartof Clinica chimica acta, 1981-11, Vol.116 (3), p.381-387
issn 0009-8981
1873-3492
language eng
recordid cdi_proquest_miscellaneous_73710712
source MEDLINE; ScienceDirect Freedom Collection (Elsevier)
subjects Cholesterol - blood
Cholesterol, HDL
Cholesterol, LDL
Cholesterol, VLDL
Humans
Hyperlipoproteinemias - blood
Lipoproteins - blood
Lipoproteins, HDL - blood
Lipoproteins, LDL - blood
Lipoproteins, VLDL - blood
Quality Control
title Accuracy and reproducibility of a quantitative electrophoresis of plasma lipoproteins: interlaboratory comparison and verification by ultracentrifugation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T15%3A13%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Accuracy%20and%20reproducibility%20of%20a%20quantitative%20electrophoresis%20of%20plasma%20lipoproteins:%20interlaboratory%20comparison%20and%20verification%20by%20ultracentrifugation&rft.jtitle=Clinica%20chimica%20acta&rft.au=Bojanovski,%20Dubo&rft.date=1981-11-11&rft.volume=116&rft.issue=3&rft.spage=381&rft.epage=387&rft.pages=381-387&rft.issn=0009-8981&rft.eissn=1873-3492&rft_id=info:doi/10.1016/0009-8981(81)90057-7&rft_dat=%3Cproquest_cross%3E73710712%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73710712&rft_id=info:pmid/6945924&rft_els_id=0009898181900577&rfr_iscdi=true