Computer interface and algorithm determines bioelectrode impedance

A computer system for measurement of electrode impedance was developed which permits periodic and automatic determination of proper electrode contact during long-term recording sessions. In addition, the voltage gain of the entire recording system was obtained for subsequent calibration of records....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Computer programs in biomedicine 1981-03, Vol.13 (1), p.3-8
1. Verfasser: Scobey, Robert P
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 8
container_issue 1
container_start_page 3
container_title Computer programs in biomedicine
container_volume 13
creator Scobey, Robert P
description A computer system for measurement of electrode impedance was developed which permits periodic and automatic determination of proper electrode contact during long-term recording sessions. In addition, the voltage gain of the entire recording system was obtained for subsequent calibration of records. The computer could then record the impedance for documentation or signal the operator for necessary electrode adjustment.
doi_str_mv 10.1016/0010-468X(81)90078-7
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73683214</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0010468X81900787</els_id><sourcerecordid>73683214</sourcerecordid><originalsourceid>FETCH-LOGICAL-c357t-ef11ff879ac5ff588f6036886a9a26ea196d73fa56a244ccb1cd4a02ce58a3863</originalsourceid><addsrcrecordid>eNp9kE1LxDAQhnNQ1nX1Hyj0JHqoJv1I04ugi1-w4EXBW5hNJhppm5q0gv_e1F326GUG3pn3HeYh5ITRS0YZv6KU0bTg4u1csIua0kqk1R6Z7-QDchjCJ6VZTqmYkVmVibLkxZzcLl3bjwP6xHaxGlCYQKcTaN6dt8NHm2iMems7DMnaOmxQDd5pTGzbo4ZO4RHZN9AEPN72BXm9v3tZPqar54en5c0qVXlZDSkaxowRVQ2qNKYUwnCacyE41JBxBFZzXeUGSg5ZUSi1ZkoXQDOFpYBc8HxBzja5vXdfI4ZBtjYobBro0I1BVjEtz1gRF4vNovIuBI9G9t624H8ko3LCJScucuIiBZN_uKJ7QU63-eO6Rb0zbVnF-fVmjvHJb4teBmUxAtDWRyhSO_v_gV9mrHyw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73683214</pqid></control><display><type>article</type><title>Computer interface and algorithm determines bioelectrode impedance</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Scobey, Robert P</creator><creatorcontrib>Scobey, Robert P</creatorcontrib><description>A computer system for measurement of electrode impedance was developed which permits periodic and automatic determination of proper electrode contact during long-term recording sessions. In addition, the voltage gain of the entire recording system was obtained for subsequent calibration of records. The computer could then record the impedance for documentation or signal the operator for necessary electrode adjustment.</description><identifier>ISSN: 0010-468X</identifier><identifier>DOI: 10.1016/0010-468X(81)90078-7</identifier><identifier>PMID: 7285564</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Bioelectrodes ; Computer interface ; Computers ; Electric Conductivity ; Electrodes ; Humans ; Impedance measurement ; Minicomputers</subject><ispartof>Computer programs in biomedicine, 1981-03, Vol.13 (1), p.3-8</ispartof><rights>1981</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c357t-ef11ff879ac5ff588f6036886a9a26ea196d73fa56a244ccb1cd4a02ce58a3863</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7285564$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Scobey, Robert P</creatorcontrib><title>Computer interface and algorithm determines bioelectrode impedance</title><title>Computer programs in biomedicine</title><addtitle>Comput Programs Biomed</addtitle><description>A computer system for measurement of electrode impedance was developed which permits periodic and automatic determination of proper electrode contact during long-term recording sessions. In addition, the voltage gain of the entire recording system was obtained for subsequent calibration of records. The computer could then record the impedance for documentation or signal the operator for necessary electrode adjustment.</description><subject>Bioelectrodes</subject><subject>Computer interface</subject><subject>Computers</subject><subject>Electric Conductivity</subject><subject>Electrodes</subject><subject>Humans</subject><subject>Impedance measurement</subject><subject>Minicomputers</subject><issn>0010-468X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1981</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE1LxDAQhnNQ1nX1Hyj0JHqoJv1I04ugi1-w4EXBW5hNJhppm5q0gv_e1F326GUG3pn3HeYh5ITRS0YZv6KU0bTg4u1csIua0kqk1R6Z7-QDchjCJ6VZTqmYkVmVibLkxZzcLl3bjwP6xHaxGlCYQKcTaN6dt8NHm2iMems7DMnaOmxQDd5pTGzbo4ZO4RHZN9AEPN72BXm9v3tZPqar54en5c0qVXlZDSkaxowRVQ2qNKYUwnCacyE41JBxBFZzXeUGSg5ZUSi1ZkoXQDOFpYBc8HxBzja5vXdfI4ZBtjYobBro0I1BVjEtz1gRF4vNovIuBI9G9t624H8ko3LCJScucuIiBZN_uKJ7QU63-eO6Rb0zbVnF-fVmjvHJb4teBmUxAtDWRyhSO_v_gV9mrHyw</recordid><startdate>198103</startdate><enddate>198103</enddate><creator>Scobey, Robert P</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>198103</creationdate><title>Computer interface and algorithm determines bioelectrode impedance</title><author>Scobey, Robert P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c357t-ef11ff879ac5ff588f6036886a9a26ea196d73fa56a244ccb1cd4a02ce58a3863</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1981</creationdate><topic>Bioelectrodes</topic><topic>Computer interface</topic><topic>Computers</topic><topic>Electric Conductivity</topic><topic>Electrodes</topic><topic>Humans</topic><topic>Impedance measurement</topic><topic>Minicomputers</topic><toplevel>online_resources</toplevel><creatorcontrib>Scobey, Robert P</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Computer programs in biomedicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Scobey, Robert P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Computer interface and algorithm determines bioelectrode impedance</atitle><jtitle>Computer programs in biomedicine</jtitle><addtitle>Comput Programs Biomed</addtitle><date>1981-03</date><risdate>1981</risdate><volume>13</volume><issue>1</issue><spage>3</spage><epage>8</epage><pages>3-8</pages><issn>0010-468X</issn><abstract>A computer system for measurement of electrode impedance was developed which permits periodic and automatic determination of proper electrode contact during long-term recording sessions. In addition, the voltage gain of the entire recording system was obtained for subsequent calibration of records. The computer could then record the impedance for documentation or signal the operator for necessary electrode adjustment.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>7285564</pmid><doi>10.1016/0010-468X(81)90078-7</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0010-468X
ispartof Computer programs in biomedicine, 1981-03, Vol.13 (1), p.3-8
issn 0010-468X
language eng
recordid cdi_proquest_miscellaneous_73683214
source MEDLINE; Alma/SFX Local Collection
subjects Bioelectrodes
Computer interface
Computers
Electric Conductivity
Electrodes
Humans
Impedance measurement
Minicomputers
title Computer interface and algorithm determines bioelectrode impedance
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T12%3A58%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Computer%20interface%20and%20algorithm%20determines%20bioelectrode%20impedance&rft.jtitle=Computer%20programs%20in%20biomedicine&rft.au=Scobey,%20Robert%20P&rft.date=1981-03&rft.volume=13&rft.issue=1&rft.spage=3&rft.epage=8&rft.pages=3-8&rft.issn=0010-468X&rft_id=info:doi/10.1016/0010-468X(81)90078-7&rft_dat=%3Cproquest_cross%3E73683214%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73683214&rft_id=info:pmid/7285564&rft_els_id=0010468X81900787&rfr_iscdi=true