Computer interface and algorithm determines bioelectrode impedance
A computer system for measurement of electrode impedance was developed which permits periodic and automatic determination of proper electrode contact during long-term recording sessions. In addition, the voltage gain of the entire recording system was obtained for subsequent calibration of records....
Gespeichert in:
Veröffentlicht in: | Computer programs in biomedicine 1981-03, Vol.13 (1), p.3-8 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 8 |
---|---|
container_issue | 1 |
container_start_page | 3 |
container_title | Computer programs in biomedicine |
container_volume | 13 |
creator | Scobey, Robert P |
description | A computer system for measurement of electrode impedance was developed which permits periodic and automatic determination of proper electrode contact during long-term recording sessions. In addition, the voltage gain of the entire recording system was obtained for subsequent calibration of records. The computer could then record the impedance for documentation or signal the operator for necessary electrode adjustment. |
doi_str_mv | 10.1016/0010-468X(81)90078-7 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73683214</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0010468X81900787</els_id><sourcerecordid>73683214</sourcerecordid><originalsourceid>FETCH-LOGICAL-c357t-ef11ff879ac5ff588f6036886a9a26ea196d73fa56a244ccb1cd4a02ce58a3863</originalsourceid><addsrcrecordid>eNp9kE1LxDAQhnNQ1nX1Hyj0JHqoJv1I04ugi1-w4EXBW5hNJhppm5q0gv_e1F326GUG3pn3HeYh5ITRS0YZv6KU0bTg4u1csIua0kqk1R6Z7-QDchjCJ6VZTqmYkVmVibLkxZzcLl3bjwP6xHaxGlCYQKcTaN6dt8NHm2iMems7DMnaOmxQDd5pTGzbo4ZO4RHZN9AEPN72BXm9v3tZPqar54en5c0qVXlZDSkaxowRVQ2qNKYUwnCacyE41JBxBFZzXeUGSg5ZUSi1ZkoXQDOFpYBc8HxBzja5vXdfI4ZBtjYobBro0I1BVjEtz1gRF4vNovIuBI9G9t624H8ko3LCJScucuIiBZN_uKJ7QU63-eO6Rb0zbVnF-fVmjvHJb4teBmUxAtDWRyhSO_v_gV9mrHyw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73683214</pqid></control><display><type>article</type><title>Computer interface and algorithm determines bioelectrode impedance</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Scobey, Robert P</creator><creatorcontrib>Scobey, Robert P</creatorcontrib><description>A computer system for measurement of electrode impedance was developed which permits periodic and automatic determination of proper electrode contact during long-term recording sessions. In addition, the voltage gain of the entire recording system was obtained for subsequent calibration of records. The computer could then record the impedance for documentation or signal the operator for necessary electrode adjustment.</description><identifier>ISSN: 0010-468X</identifier><identifier>DOI: 10.1016/0010-468X(81)90078-7</identifier><identifier>PMID: 7285564</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Bioelectrodes ; Computer interface ; Computers ; Electric Conductivity ; Electrodes ; Humans ; Impedance measurement ; Minicomputers</subject><ispartof>Computer programs in biomedicine, 1981-03, Vol.13 (1), p.3-8</ispartof><rights>1981</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c357t-ef11ff879ac5ff588f6036886a9a26ea196d73fa56a244ccb1cd4a02ce58a3863</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7285564$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Scobey, Robert P</creatorcontrib><title>Computer interface and algorithm determines bioelectrode impedance</title><title>Computer programs in biomedicine</title><addtitle>Comput Programs Biomed</addtitle><description>A computer system for measurement of electrode impedance was developed which permits periodic and automatic determination of proper electrode contact during long-term recording sessions. In addition, the voltage gain of the entire recording system was obtained for subsequent calibration of records. The computer could then record the impedance for documentation or signal the operator for necessary electrode adjustment.</description><subject>Bioelectrodes</subject><subject>Computer interface</subject><subject>Computers</subject><subject>Electric Conductivity</subject><subject>Electrodes</subject><subject>Humans</subject><subject>Impedance measurement</subject><subject>Minicomputers</subject><issn>0010-468X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1981</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE1LxDAQhnNQ1nX1Hyj0JHqoJv1I04ugi1-w4EXBW5hNJhppm5q0gv_e1F326GUG3pn3HeYh5ITRS0YZv6KU0bTg4u1csIua0kqk1R6Z7-QDchjCJ6VZTqmYkVmVibLkxZzcLl3bjwP6xHaxGlCYQKcTaN6dt8NHm2iMems7DMnaOmxQDd5pTGzbo4ZO4RHZN9AEPN72BXm9v3tZPqar54en5c0qVXlZDSkaxowRVQ2qNKYUwnCacyE41JBxBFZzXeUGSg5ZUSi1ZkoXQDOFpYBc8HxBzja5vXdfI4ZBtjYobBro0I1BVjEtz1gRF4vNovIuBI9G9t624H8ko3LCJScucuIiBZN_uKJ7QU63-eO6Rb0zbVnF-fVmjvHJb4teBmUxAtDWRyhSO_v_gV9mrHyw</recordid><startdate>198103</startdate><enddate>198103</enddate><creator>Scobey, Robert P</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>198103</creationdate><title>Computer interface and algorithm determines bioelectrode impedance</title><author>Scobey, Robert P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c357t-ef11ff879ac5ff588f6036886a9a26ea196d73fa56a244ccb1cd4a02ce58a3863</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1981</creationdate><topic>Bioelectrodes</topic><topic>Computer interface</topic><topic>Computers</topic><topic>Electric Conductivity</topic><topic>Electrodes</topic><topic>Humans</topic><topic>Impedance measurement</topic><topic>Minicomputers</topic><toplevel>online_resources</toplevel><creatorcontrib>Scobey, Robert P</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Computer programs in biomedicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Scobey, Robert P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Computer interface and algorithm determines bioelectrode impedance</atitle><jtitle>Computer programs in biomedicine</jtitle><addtitle>Comput Programs Biomed</addtitle><date>1981-03</date><risdate>1981</risdate><volume>13</volume><issue>1</issue><spage>3</spage><epage>8</epage><pages>3-8</pages><issn>0010-468X</issn><abstract>A computer system for measurement of electrode impedance was developed which permits periodic and automatic determination of proper electrode contact during long-term recording sessions. In addition, the voltage gain of the entire recording system was obtained for subsequent calibration of records. The computer could then record the impedance for documentation or signal the operator for necessary electrode adjustment.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>7285564</pmid><doi>10.1016/0010-468X(81)90078-7</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0010-468X |
ispartof | Computer programs in biomedicine, 1981-03, Vol.13 (1), p.3-8 |
issn | 0010-468X |
language | eng |
recordid | cdi_proquest_miscellaneous_73683214 |
source | MEDLINE; Alma/SFX Local Collection |
subjects | Bioelectrodes Computer interface Computers Electric Conductivity Electrodes Humans Impedance measurement Minicomputers |
title | Computer interface and algorithm determines bioelectrode impedance |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T12%3A58%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Computer%20interface%20and%20algorithm%20determines%20bioelectrode%20impedance&rft.jtitle=Computer%20programs%20in%20biomedicine&rft.au=Scobey,%20Robert%20P&rft.date=1981-03&rft.volume=13&rft.issue=1&rft.spage=3&rft.epage=8&rft.pages=3-8&rft.issn=0010-468X&rft_id=info:doi/10.1016/0010-468X(81)90078-7&rft_dat=%3Cproquest_cross%3E73683214%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73683214&rft_id=info:pmid/7285564&rft_els_id=0010468X81900787&rfr_iscdi=true |