Measuring of distortion product otoacoustic emissions using multiple tone pairs

In order to reduce the examination time of the Distortion Product Otoacoustic Emissions (DPOAE) test, we investigated the applicability of the multiple-tone pairs method by comparing the DPOAE evoked by 4- and 3-tone pairs (Sim) with the conventional 1-tone pair (Seq) in 116 ears of human adults wit...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European archives of oto-rhino-laryngology 2003-08, Vol.260 (7), p.395-400
Hauptverfasser: KASTANIOUDAKIS, Ioannis, ZIAVRA, Nausica, ANASTASOPOULOS, Dimitrios, SKEVAS, Antonios
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 400
container_issue 7
container_start_page 395
container_title European archives of oto-rhino-laryngology
container_volume 260
creator KASTANIOUDAKIS, Ioannis
ZIAVRA, Nausica
ANASTASOPOULOS, Dimitrios
SKEVAS, Antonios
description In order to reduce the examination time of the Distortion Product Otoacoustic Emissions (DPOAE) test, we investigated the applicability of the multiple-tone pairs method by comparing the DPOAE evoked by 4- and 3-tone pairs (Sim) with the conventional 1-tone pair (Seq) in 116 ears of human adults with normal hearing (NH) and 86 ears with sensorineural hearing loss (SNHL). We found that: (1) DPOAE amplitudes in the NH group obtained with the Sim method were strongly correlated with those of Seq. (2) DPOAE amplitude and noise level mean values obtained with the Seq method were significantly higher than those obtained with Sim. (3) DPOAE amplitude was independent of the stimulation side (right vs. left ears). (4) Both methods can equally distinguish ears with NH and a low degree of SNHL from those with higher degrees of SNHL. (5) Examination time was shorter with the Sim method in both groups. In conclusion, the Sim method produces results similar to those of Seq. However, a significant difference between the two methods in relation to DPOAE amplitudes and noise levels was found. Because of this, normal data for both the DPOAE amplitude and noise level are required to improve the sensitivity of the Sim method. The mean examination time in both groups (NH and SNHL) was shorter with the Sim method. Therefore, the multiple-tone pairs stimulation method seems to be more suitable when it is used as an auditory screening test.
doi_str_mv 10.1007/s00405-003-0596-9
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73568535</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>73568535</sourcerecordid><originalsourceid>FETCH-LOGICAL-c327t-a4e799c63fdd85a26b3c3d3f53e0dc9e5421c5e8a2b1326cc7a7879f6d9e1fd13</originalsourceid><addsrcrecordid>eNpFkD1PwzAQhi0EoqXwA1hQFtgC59iO6xEhvqSiLjBbru0gozQOPmfg3-OqlTrdcM979-oh5JrCPQWQDwjAQdQArAah2lqdkDnljNdcNu0pmYNisuZcyhm5QPwBAMEVOycz2pSNomJO1h_e4JTC8F3FrnIBc0w5xKEaU3STzVXM0dg4YQ628tuAWJZYTbhLbKc-h7H3VY6Dr0YTEl6Ss8706K8Oc0G-Xp4_n97q1fr1_elxVVvWyFwb7qVStmWdc0thmnbDLHOsE8yDs8oL3lAr_NI0G8qa1lpp5FKqrnXK085RtiB3-7ul5-_kMevSzfq-N4MvbbVkol0KJgpI96BNETH5To8pbE360xT0zqLeW9TFot5Z1Kpkbg7Hp83Wu2PioK0AtwfAoDV9l8xgAx45AZJDef8PF5d8Ew</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73568535</pqid></control><display><type>article</type><title>Measuring of distortion product otoacoustic emissions using multiple tone pairs</title><source>MEDLINE</source><source>SpringerNature Journals</source><creator>KASTANIOUDAKIS, Ioannis ; ZIAVRA, Nausica ; ANASTASOPOULOS, Dimitrios ; SKEVAS, Antonios</creator><creatorcontrib>KASTANIOUDAKIS, Ioannis ; ZIAVRA, Nausica ; ANASTASOPOULOS, Dimitrios ; SKEVAS, Antonios</creatorcontrib><description>In order to reduce the examination time of the Distortion Product Otoacoustic Emissions (DPOAE) test, we investigated the applicability of the multiple-tone pairs method by comparing the DPOAE evoked by 4- and 3-tone pairs (Sim) with the conventional 1-tone pair (Seq) in 116 ears of human adults with normal hearing (NH) and 86 ears with sensorineural hearing loss (SNHL). We found that: (1) DPOAE amplitudes in the NH group obtained with the Sim method were strongly correlated with those of Seq. (2) DPOAE amplitude and noise level mean values obtained with the Seq method were significantly higher than those obtained with Sim. (3) DPOAE amplitude was independent of the stimulation side (right vs. left ears). (4) Both methods can equally distinguish ears with NH and a low degree of SNHL from those with higher degrees of SNHL. (5) Examination time was shorter with the Sim method in both groups. In conclusion, the Sim method produces results similar to those of Seq. However, a significant difference between the two methods in relation to DPOAE amplitudes and noise levels was found. Because of this, normal data for both the DPOAE amplitude and noise level are required to improve the sensitivity of the Sim method. The mean examination time in both groups (NH and SNHL) was shorter with the Sim method. Therefore, the multiple-tone pairs stimulation method seems to be more suitable when it is used as an auditory screening test.</description><identifier>ISSN: 0937-4477</identifier><identifier>EISSN: 1434-4726</identifier><identifier>DOI: 10.1007/s00405-003-0596-9</identifier><identifier>PMID: 12937915</identifier><language>eng</language><publisher>Berlin: Springer</publisher><subject>Acoustic Stimulation ; Adolescent ; Adult ; Aged ; Audiometry, Pure-Tone ; Auditory Threshold ; Biological and medical sciences ; Ear, auditive nerve, cochleovestibular tract, facial nerve: diseases, semeiology ; Female ; Hearing ; Hearing Disorders - diagnosis ; Hearing Disorders - physiopathology ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Male ; Medical sciences ; Middle Aged ; Non tumoral diseases ; Otoacoustic Emissions, Spontaneous ; Otorhinolaryngology functional investigation (larynx, voice, audiometry, vestibular function, equilibration...) ; Otorhinolaryngology. Stomatology</subject><ispartof>European archives of oto-rhino-laryngology, 2003-08, Vol.260 (7), p.395-400</ispartof><rights>2004 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c327t-a4e799c63fdd85a26b3c3d3f53e0dc9e5421c5e8a2b1326cc7a7879f6d9e1fd13</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=15074085$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12937915$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>KASTANIOUDAKIS, Ioannis</creatorcontrib><creatorcontrib>ZIAVRA, Nausica</creatorcontrib><creatorcontrib>ANASTASOPOULOS, Dimitrios</creatorcontrib><creatorcontrib>SKEVAS, Antonios</creatorcontrib><title>Measuring of distortion product otoacoustic emissions using multiple tone pairs</title><title>European archives of oto-rhino-laryngology</title><addtitle>Eur Arch Otorhinolaryngol</addtitle><description>In order to reduce the examination time of the Distortion Product Otoacoustic Emissions (DPOAE) test, we investigated the applicability of the multiple-tone pairs method by comparing the DPOAE evoked by 4- and 3-tone pairs (Sim) with the conventional 1-tone pair (Seq) in 116 ears of human adults with normal hearing (NH) and 86 ears with sensorineural hearing loss (SNHL). We found that: (1) DPOAE amplitudes in the NH group obtained with the Sim method were strongly correlated with those of Seq. (2) DPOAE amplitude and noise level mean values obtained with the Seq method were significantly higher than those obtained with Sim. (3) DPOAE amplitude was independent of the stimulation side (right vs. left ears). (4) Both methods can equally distinguish ears with NH and a low degree of SNHL from those with higher degrees of SNHL. (5) Examination time was shorter with the Sim method in both groups. In conclusion, the Sim method produces results similar to those of Seq. However, a significant difference between the two methods in relation to DPOAE amplitudes and noise levels was found. Because of this, normal data for both the DPOAE amplitude and noise level are required to improve the sensitivity of the Sim method. The mean examination time in both groups (NH and SNHL) was shorter with the Sim method. Therefore, the multiple-tone pairs stimulation method seems to be more suitable when it is used as an auditory screening test.</description><subject>Acoustic Stimulation</subject><subject>Adolescent</subject><subject>Adult</subject><subject>Aged</subject><subject>Audiometry, Pure-Tone</subject><subject>Auditory Threshold</subject><subject>Biological and medical sciences</subject><subject>Ear, auditive nerve, cochleovestibular tract, facial nerve: diseases, semeiology</subject><subject>Female</subject><subject>Hearing</subject><subject>Hearing Disorders - diagnosis</subject><subject>Hearing Disorders - physiopathology</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Non tumoral diseases</subject><subject>Otoacoustic Emissions, Spontaneous</subject><subject>Otorhinolaryngology functional investigation (larynx, voice, audiometry, vestibular function, equilibration...)</subject><subject>Otorhinolaryngology. Stomatology</subject><issn>0937-4477</issn><issn>1434-4726</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkD1PwzAQhi0EoqXwA1hQFtgC59iO6xEhvqSiLjBbru0gozQOPmfg3-OqlTrdcM979-oh5JrCPQWQDwjAQdQArAah2lqdkDnljNdcNu0pmYNisuZcyhm5QPwBAMEVOycz2pSNomJO1h_e4JTC8F3FrnIBc0w5xKEaU3STzVXM0dg4YQ628tuAWJZYTbhLbKc-h7H3VY6Dr0YTEl6Ss8706K8Oc0G-Xp4_n97q1fr1_elxVVvWyFwb7qVStmWdc0thmnbDLHOsE8yDs8oL3lAr_NI0G8qa1lpp5FKqrnXK085RtiB3-7ul5-_kMevSzfq-N4MvbbVkol0KJgpI96BNETH5To8pbE360xT0zqLeW9TFot5Z1Kpkbg7Hp83Wu2PioK0AtwfAoDV9l8xgAx45AZJDef8PF5d8Ew</recordid><startdate>20030801</startdate><enddate>20030801</enddate><creator>KASTANIOUDAKIS, Ioannis</creator><creator>ZIAVRA, Nausica</creator><creator>ANASTASOPOULOS, Dimitrios</creator><creator>SKEVAS, Antonios</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20030801</creationdate><title>Measuring of distortion product otoacoustic emissions using multiple tone pairs</title><author>KASTANIOUDAKIS, Ioannis ; ZIAVRA, Nausica ; ANASTASOPOULOS, Dimitrios ; SKEVAS, Antonios</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c327t-a4e799c63fdd85a26b3c3d3f53e0dc9e5421c5e8a2b1326cc7a7879f6d9e1fd13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Acoustic Stimulation</topic><topic>Adolescent</topic><topic>Adult</topic><topic>Aged</topic><topic>Audiometry, Pure-Tone</topic><topic>Auditory Threshold</topic><topic>Biological and medical sciences</topic><topic>Ear, auditive nerve, cochleovestibular tract, facial nerve: diseases, semeiology</topic><topic>Female</topic><topic>Hearing</topic><topic>Hearing Disorders - diagnosis</topic><topic>Hearing Disorders - physiopathology</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Non tumoral diseases</topic><topic>Otoacoustic Emissions, Spontaneous</topic><topic>Otorhinolaryngology functional investigation (larynx, voice, audiometry, vestibular function, equilibration...)</topic><topic>Otorhinolaryngology. Stomatology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>KASTANIOUDAKIS, Ioannis</creatorcontrib><creatorcontrib>ZIAVRA, Nausica</creatorcontrib><creatorcontrib>ANASTASOPOULOS, Dimitrios</creatorcontrib><creatorcontrib>SKEVAS, Antonios</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European archives of oto-rhino-laryngology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>KASTANIOUDAKIS, Ioannis</au><au>ZIAVRA, Nausica</au><au>ANASTASOPOULOS, Dimitrios</au><au>SKEVAS, Antonios</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Measuring of distortion product otoacoustic emissions using multiple tone pairs</atitle><jtitle>European archives of oto-rhino-laryngology</jtitle><addtitle>Eur Arch Otorhinolaryngol</addtitle><date>2003-08-01</date><risdate>2003</risdate><volume>260</volume><issue>7</issue><spage>395</spage><epage>400</epage><pages>395-400</pages><issn>0937-4477</issn><eissn>1434-4726</eissn><abstract>In order to reduce the examination time of the Distortion Product Otoacoustic Emissions (DPOAE) test, we investigated the applicability of the multiple-tone pairs method by comparing the DPOAE evoked by 4- and 3-tone pairs (Sim) with the conventional 1-tone pair (Seq) in 116 ears of human adults with normal hearing (NH) and 86 ears with sensorineural hearing loss (SNHL). We found that: (1) DPOAE amplitudes in the NH group obtained with the Sim method were strongly correlated with those of Seq. (2) DPOAE amplitude and noise level mean values obtained with the Seq method were significantly higher than those obtained with Sim. (3) DPOAE amplitude was independent of the stimulation side (right vs. left ears). (4) Both methods can equally distinguish ears with NH and a low degree of SNHL from those with higher degrees of SNHL. (5) Examination time was shorter with the Sim method in both groups. In conclusion, the Sim method produces results similar to those of Seq. However, a significant difference between the two methods in relation to DPOAE amplitudes and noise levels was found. Because of this, normal data for both the DPOAE amplitude and noise level are required to improve the sensitivity of the Sim method. The mean examination time in both groups (NH and SNHL) was shorter with the Sim method. Therefore, the multiple-tone pairs stimulation method seems to be more suitable when it is used as an auditory screening test.</abstract><cop>Berlin</cop><pub>Springer</pub><pmid>12937915</pmid><doi>10.1007/s00405-003-0596-9</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0937-4477
ispartof European archives of oto-rhino-laryngology, 2003-08, Vol.260 (7), p.395-400
issn 0937-4477
1434-4726
language eng
recordid cdi_proquest_miscellaneous_73568535
source MEDLINE; SpringerNature Journals
subjects Acoustic Stimulation
Adolescent
Adult
Aged
Audiometry, Pure-Tone
Auditory Threshold
Biological and medical sciences
Ear, auditive nerve, cochleovestibular tract, facial nerve: diseases, semeiology
Female
Hearing
Hearing Disorders - diagnosis
Hearing Disorders - physiopathology
Humans
Investigative techniques, diagnostic techniques (general aspects)
Male
Medical sciences
Middle Aged
Non tumoral diseases
Otoacoustic Emissions, Spontaneous
Otorhinolaryngology functional investigation (larynx, voice, audiometry, vestibular function, equilibration...)
Otorhinolaryngology. Stomatology
title Measuring of distortion product otoacoustic emissions using multiple tone pairs
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T23%3A37%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Measuring%20of%20distortion%20product%20otoacoustic%20emissions%20using%20multiple%20tone%20pairs&rft.jtitle=European%20archives%20of%20oto-rhino-laryngology&rft.au=KASTANIOUDAKIS,%20Ioannis&rft.date=2003-08-01&rft.volume=260&rft.issue=7&rft.spage=395&rft.epage=400&rft.pages=395-400&rft.issn=0937-4477&rft.eissn=1434-4726&rft_id=info:doi/10.1007/s00405-003-0596-9&rft_dat=%3Cproquest_cross%3E73568535%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73568535&rft_id=info:pmid/12937915&rfr_iscdi=true