The use of solid phase clq and horseradish peroxidase-conjugated goat anti-IgG for the detection of immune complexes in human serum

An alternative method is described for detecting immune complexes in human serum. The technique uses peroxidase-conjugated goat anti-human IgG to detect immune complexes bound to solid phase Clq † † Clq is a subcomponent of Cl, the first component of complement: C l r̄ and C l s̄, activated forms of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Molecular immunology 1981-03, Vol.18 (3), p.157-162
Hauptverfasser: Wehler, Cheryl, Andrews, Judith M., Bing, David H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 162
container_issue 3
container_start_page 157
container_title Molecular immunology
container_volume 18
creator Wehler, Cheryl
Andrews, Judith M.
Bing, David H.
description An alternative method is described for detecting immune complexes in human serum. The technique uses peroxidase-conjugated goat anti-human IgG to detect immune complexes bound to solid phase Clq † † Clq is a subcomponent of Cl, the first component of complement: C l r̄ and C l s̄, activated forms of the other two subcomponents of Cl; EAC4, rabbit antibody sensitized sheep erythrocytes bound to C4, the fourth component of complement; C2, second component of complement; CEDTA, whole complement diluted in 0.01 M EDTA; HAG, heat-aggregated IgG; PBS, phosphate buffered saline; ELISA, enzyme linked immunoadsorbent assay; SLE, systemic lupus erythematosus. Complement nomenclature is the recommendation of Bull. W.H.0. 39, 935, 1968. . The level of immune complexes is determined by reference to a standard curve constructed with heat-aggregated IgG. The assay is sensitive, detecting 10–10,000 ng of heat-aggregated IgG. Exogenous Clq (5–100 μg/ml) and heparin (5–500 μg/ml) do not interfere with the assay. Data are presented which show the levels of immune complexes in 79 normal individuals and 25 patients with systemic lupus erythematosus.
doi_str_mv 10.1016/0161-5890(81)90081-X
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73531588</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>016158908190081X</els_id><sourcerecordid>73531588</sourcerecordid><originalsourceid>FETCH-LOGICAL-c357t-3ddbf0576fac6e106389560870037f28d68ac5ff84a1bb15999a1ea05d5d7a143</originalsourceid><addsrcrecordid>eNp9kEFLHDEYhkOx2K32H7SQk9jD1C87m0xyKRSxKgheFLyFbPJlJzIzGZMZsWf_uNnu4tFDCOF9v-cjDyHfGfxiwMRZOaziUsGpZD8VgGTVwyeyYLJZVoqtlgdk8V75Qr7m_AgAAgQ_JIdCNbVQsCCvdy3SOSONnubYBUfH1pSn7Z6oGRxtY8qYjAu5pSOm-BJciSsbh8d5YyZ0dBPNVKpTqK43l9THRKeCdDihnUIctuDQ9_NQmLEfO3zBTMNA27k3Ay3suT8mn73pMn7b30fk_u_F3flVdXN7eX3-56ayNW-mqnZu7YE3whsrkIGopeICZANQN34pnZDGcu_lyrD1mnGllGFogDvuGsNW9RE52XHHFJ9mzJPuQ7bYdWbAOGfd1LxmXMpSXO2KNsWcE3o9ptCb9E8z0Fv3eitWb8VqyfR_9_qhjP3Y8-d1j-59aC-75L93OZZPPgdMOtuAg0UXUpGlXQwfL3gDjbSVCg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73531588</pqid></control><display><type>article</type><title>The use of solid phase clq and horseradish peroxidase-conjugated goat anti-IgG for the detection of immune complexes in human serum</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Wehler, Cheryl ; Andrews, Judith M. ; Bing, David H.</creator><creatorcontrib>Wehler, Cheryl ; Andrews, Judith M. ; Bing, David H.</creatorcontrib><description>An alternative method is described for detecting immune complexes in human serum. The technique uses peroxidase-conjugated goat anti-human IgG to detect immune complexes bound to solid phase Clq † † Clq is a subcomponent of Cl, the first component of complement: C l r̄ and C l s̄, activated forms of the other two subcomponents of Cl; EAC4, rabbit antibody sensitized sheep erythrocytes bound to C4, the fourth component of complement; C2, second component of complement; CEDTA, whole complement diluted in 0.01 M EDTA; HAG, heat-aggregated IgG; PBS, phosphate buffered saline; ELISA, enzyme linked immunoadsorbent assay; SLE, systemic lupus erythematosus. Complement nomenclature is the recommendation of Bull. W.H.0. 39, 935, 1968. . The level of immune complexes is determined by reference to a standard curve constructed with heat-aggregated IgG. The assay is sensitive, detecting 10–10,000 ng of heat-aggregated IgG. Exogenous Clq (5–100 μg/ml) and heparin (5–500 μg/ml) do not interfere with the assay. Data are presented which show the levels of immune complexes in 79 normal individuals and 25 patients with systemic lupus erythematosus.</description><identifier>ISSN: 0161-5890</identifier><identifier>EISSN: 1872-9142</identifier><identifier>DOI: 10.1016/0161-5890(81)90081-X</identifier><identifier>PMID: 6973690</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Antigen-Antibody Complex - analysis ; Complement Activating Enzymes - immunology ; Complement C1q ; Dose-Response Relationship, Immunologic ; Enzyme-Linked Immunosorbent Assay ; Heparin - pharmacology ; Horseradish Peroxidase ; Hot Temperature ; Humans ; Immunoglobulin G - immunology ; Methods</subject><ispartof>Molecular immunology, 1981-03, Vol.18 (3), p.157-162</ispartof><rights>1981</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c357t-3ddbf0576fac6e106389560870037f28d68ac5ff84a1bb15999a1ea05d5d7a143</citedby><cites>FETCH-LOGICAL-c357t-3ddbf0576fac6e106389560870037f28d68ac5ff84a1bb15999a1ea05d5d7a143</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/0161-5890(81)90081-X$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/6973690$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wehler, Cheryl</creatorcontrib><creatorcontrib>Andrews, Judith M.</creatorcontrib><creatorcontrib>Bing, David H.</creatorcontrib><title>The use of solid phase clq and horseradish peroxidase-conjugated goat anti-IgG for the detection of immune complexes in human serum</title><title>Molecular immunology</title><addtitle>Mol Immunol</addtitle><description>An alternative method is described for detecting immune complexes in human serum. The technique uses peroxidase-conjugated goat anti-human IgG to detect immune complexes bound to solid phase Clq † † Clq is a subcomponent of Cl, the first component of complement: C l r̄ and C l s̄, activated forms of the other two subcomponents of Cl; EAC4, rabbit antibody sensitized sheep erythrocytes bound to C4, the fourth component of complement; C2, second component of complement; CEDTA, whole complement diluted in 0.01 M EDTA; HAG, heat-aggregated IgG; PBS, phosphate buffered saline; ELISA, enzyme linked immunoadsorbent assay; SLE, systemic lupus erythematosus. Complement nomenclature is the recommendation of Bull. W.H.0. 39, 935, 1968. . The level of immune complexes is determined by reference to a standard curve constructed with heat-aggregated IgG. The assay is sensitive, detecting 10–10,000 ng of heat-aggregated IgG. Exogenous Clq (5–100 μg/ml) and heparin (5–500 μg/ml) do not interfere with the assay. Data are presented which show the levels of immune complexes in 79 normal individuals and 25 patients with systemic lupus erythematosus.</description><subject>Antigen-Antibody Complex - analysis</subject><subject>Complement Activating Enzymes - immunology</subject><subject>Complement C1q</subject><subject>Dose-Response Relationship, Immunologic</subject><subject>Enzyme-Linked Immunosorbent Assay</subject><subject>Heparin - pharmacology</subject><subject>Horseradish Peroxidase</subject><subject>Hot Temperature</subject><subject>Humans</subject><subject>Immunoglobulin G - immunology</subject><subject>Methods</subject><issn>0161-5890</issn><issn>1872-9142</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1981</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kEFLHDEYhkOx2K32H7SQk9jD1C87m0xyKRSxKgheFLyFbPJlJzIzGZMZsWf_uNnu4tFDCOF9v-cjDyHfGfxiwMRZOaziUsGpZD8VgGTVwyeyYLJZVoqtlgdk8V75Qr7m_AgAAgQ_JIdCNbVQsCCvdy3SOSONnubYBUfH1pSn7Z6oGRxtY8qYjAu5pSOm-BJciSsbh8d5YyZ0dBPNVKpTqK43l9THRKeCdDihnUIctuDQ9_NQmLEfO3zBTMNA27k3Ay3suT8mn73pMn7b30fk_u_F3flVdXN7eX3-56ayNW-mqnZu7YE3whsrkIGopeICZANQN34pnZDGcu_lyrD1mnGllGFogDvuGsNW9RE52XHHFJ9mzJPuQ7bYdWbAOGfd1LxmXMpSXO2KNsWcE3o9ptCb9E8z0Fv3eitWb8VqyfR_9_qhjP3Y8-d1j-59aC-75L93OZZPPgdMOtuAg0UXUpGlXQwfL3gDjbSVCg</recordid><startdate>198103</startdate><enddate>198103</enddate><creator>Wehler, Cheryl</creator><creator>Andrews, Judith M.</creator><creator>Bing, David H.</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>198103</creationdate><title>The use of solid phase clq and horseradish peroxidase-conjugated goat anti-IgG for the detection of immune complexes in human serum</title><author>Wehler, Cheryl ; Andrews, Judith M. ; Bing, David H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c357t-3ddbf0576fac6e106389560870037f28d68ac5ff84a1bb15999a1ea05d5d7a143</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1981</creationdate><topic>Antigen-Antibody Complex - analysis</topic><topic>Complement Activating Enzymes - immunology</topic><topic>Complement C1q</topic><topic>Dose-Response Relationship, Immunologic</topic><topic>Enzyme-Linked Immunosorbent Assay</topic><topic>Heparin - pharmacology</topic><topic>Horseradish Peroxidase</topic><topic>Hot Temperature</topic><topic>Humans</topic><topic>Immunoglobulin G - immunology</topic><topic>Methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wehler, Cheryl</creatorcontrib><creatorcontrib>Andrews, Judith M.</creatorcontrib><creatorcontrib>Bing, David H.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Molecular immunology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wehler, Cheryl</au><au>Andrews, Judith M.</au><au>Bing, David H.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The use of solid phase clq and horseradish peroxidase-conjugated goat anti-IgG for the detection of immune complexes in human serum</atitle><jtitle>Molecular immunology</jtitle><addtitle>Mol Immunol</addtitle><date>1981-03</date><risdate>1981</risdate><volume>18</volume><issue>3</issue><spage>157</spage><epage>162</epage><pages>157-162</pages><issn>0161-5890</issn><eissn>1872-9142</eissn><abstract>An alternative method is described for detecting immune complexes in human serum. The technique uses peroxidase-conjugated goat anti-human IgG to detect immune complexes bound to solid phase Clq † † Clq is a subcomponent of Cl, the first component of complement: C l r̄ and C l s̄, activated forms of the other two subcomponents of Cl; EAC4, rabbit antibody sensitized sheep erythrocytes bound to C4, the fourth component of complement; C2, second component of complement; CEDTA, whole complement diluted in 0.01 M EDTA; HAG, heat-aggregated IgG; PBS, phosphate buffered saline; ELISA, enzyme linked immunoadsorbent assay; SLE, systemic lupus erythematosus. Complement nomenclature is the recommendation of Bull. W.H.0. 39, 935, 1968. . The level of immune complexes is determined by reference to a standard curve constructed with heat-aggregated IgG. The assay is sensitive, detecting 10–10,000 ng of heat-aggregated IgG. Exogenous Clq (5–100 μg/ml) and heparin (5–500 μg/ml) do not interfere with the assay. Data are presented which show the levels of immune complexes in 79 normal individuals and 25 patients with systemic lupus erythematosus.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>6973690</pmid><doi>10.1016/0161-5890(81)90081-X</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0161-5890
ispartof Molecular immunology, 1981-03, Vol.18 (3), p.157-162
issn 0161-5890
1872-9142
language eng
recordid cdi_proquest_miscellaneous_73531588
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects Antigen-Antibody Complex - analysis
Complement Activating Enzymes - immunology
Complement C1q
Dose-Response Relationship, Immunologic
Enzyme-Linked Immunosorbent Assay
Heparin - pharmacology
Horseradish Peroxidase
Hot Temperature
Humans
Immunoglobulin G - immunology
Methods
title The use of solid phase clq and horseradish peroxidase-conjugated goat anti-IgG for the detection of immune complexes in human serum
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T17%3A35%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20use%20of%20solid%20phase%20clq%20and%20horseradish%20peroxidase-conjugated%20goat%20anti-IgG%20for%20the%20detection%20of%20immune%20complexes%20in%20human%20serum&rft.jtitle=Molecular%20immunology&rft.au=Wehler,%20Cheryl&rft.date=1981-03&rft.volume=18&rft.issue=3&rft.spage=157&rft.epage=162&rft.pages=157-162&rft.issn=0161-5890&rft.eissn=1872-9142&rft_id=info:doi/10.1016/0161-5890(81)90081-X&rft_dat=%3Cproquest_cross%3E73531588%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73531588&rft_id=info:pmid/6973690&rft_els_id=016158908190081X&rfr_iscdi=true