Form Reappearance of the Section Sensitivity Profile on Z-axis in Multi-detector Spiral Computed Tomography
The filter is hung in the direction of slice thickness (Z-axis) in the reconstruction of multi-detector spiral CT. Because of this, performing several time scans is considered useful from the standpoint of reappearance of the section sensitivity profile curves. However, when examination is done at f...
Gespeichert in:
Veröffentlicht in: | Japanese Journal of Radiological Technology 2003/05/20, Vol.59(5), pp.627-631 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng ; jpn |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 631 |
---|---|
container_issue | 5 |
container_start_page | 627 |
container_title | Japanese Journal of Radiological Technology |
container_volume | 59 |
creator | TACHIBANA, MASAYUKI |
description | The filter is hung in the direction of slice thickness (Z-axis) in the reconstruction of multi-detector spiral CT. Because of this, performing several time scans is considered useful from the standpoint of reappearance of the section sensitivity profile curves. However, when examination is done at full width half maximum (FWHM) and the position of the center of FWHM, there is non-symmetry and the level of hem extent of the section sensitivity profile curves. Change in FWHM and the position of the center of FWHM increases as pitch increases. Although the change in FWHM was less when the reconstruction slice thickness was increased, the change became larger in the center of FWHM as well. As for the non-symmetry of the section sensitivity profile curves and the level of hem extent, the change decreased when the reconstruction slice thickness was increased, although it increased when pitch was enlarged. It is considered that the cause of these changes is change in table movement speed during scanning. |
doi_str_mv | 10.6009/jjrt.KJ00000921803 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73511179</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>73511179</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3233-1066d582a45069ee442ac0c7a59ee50d2391ffab07e1517ea9ec200984c8b3a3</originalsourceid><addsrcrecordid>eNp9kMFu1DAURS0EoqPSH2CBvGKXYsdxYi_RiFKgFYjOio31xnnpeEjiYDuI-XsczaioLOqFn2ydc6V3CXnN2WXNmH6334d0-eUzW44uuWLiGVlxpXhRKSWekxUTtS4qweQZuYjRbRcuf7HqJTnjZQZrLVbk55UPA_2OME0IAUaL1Hc07ZDeoU3Oj3mO0SX326UD_RZ85_qMjPRHAX9cpG6kt3OfXNFiyoIP9G5yAXq69sM0J2zpxg_-PsC0O7wiLzroI16c5jnZXH3YrK-Lm68fP63f3xRWlEIUnNV1K1UJlWS1RqyqEiyzDcj8kKwtheZdB1vWIJe8QdBoy7ycqqzaChDn5O0xdgr-14wxmcFFi30PI_o5mkZIznmjM1geQRt8jAE7MwU3QDgYzsxSsllKNo9KztKbU_q8HbD9p5wqzYD6L9W6BEuVKYDrn86-Pqr7mOAeH7IhJGd7PCpSG7lcj9QHxO4gGBzFXyDNpRQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73511179</pqid></control><display><type>article</type><title>Form Reappearance of the Section Sensitivity Profile on Z-axis in Multi-detector Spiral Computed Tomography</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>TACHIBANA, MASAYUKI</creator><creatorcontrib>TACHIBANA, MASAYUKI</creatorcontrib><description>The filter is hung in the direction of slice thickness (Z-axis) in the reconstruction of multi-detector spiral CT. Because of this, performing several time scans is considered useful from the standpoint of reappearance of the section sensitivity profile curves. However, when examination is done at full width half maximum (FWHM) and the position of the center of FWHM, there is non-symmetry and the level of hem extent of the section sensitivity profile curves. Change in FWHM and the position of the center of FWHM increases as pitch increases. Although the change in FWHM was less when the reconstruction slice thickness was increased, the change became larger in the center of FWHM as well. As for the non-symmetry of the section sensitivity profile curves and the level of hem extent, the change decreased when the reconstruction slice thickness was increased, although it increased when pitch was enlarged. It is considered that the cause of these changes is change in table movement speed during scanning.</description><identifier>ISSN: 0369-4305</identifier><identifier>EISSN: 1881-4883</identifier><identifier>DOI: 10.6009/jjrt.KJ00000921803</identifier><identifier>PMID: 12881693</identifier><language>eng ; jpn</language><publisher>Japan: Japanese Society of Radiological Technology</publisher><subject>Image Processing, Computer-Assisted - methods ; Radiographic Image Enhancement - methods ; Section sensitivity profile on Z-axis ; Tomography, Spiral Computed - methods ; X-ray computed tomograpby</subject><ispartof>Japanese Journal of Radiological Technology, 2003/05/20, Vol.59(5), pp.627-631</ispartof><rights>2003 Japanese Society of Radiological Technology</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3233-1066d582a45069ee442ac0c7a59ee50d2391ffab07e1517ea9ec200984c8b3a3</citedby><cites>FETCH-LOGICAL-c3233-1066d582a45069ee442ac0c7a59ee50d2391ffab07e1517ea9ec200984c8b3a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12881693$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>TACHIBANA, MASAYUKI</creatorcontrib><title>Form Reappearance of the Section Sensitivity Profile on Z-axis in Multi-detector Spiral Computed Tomography</title><title>Japanese Journal of Radiological Technology</title><addtitle>Jpn. J. Radiol. Technol.</addtitle><description>The filter is hung in the direction of slice thickness (Z-axis) in the reconstruction of multi-detector spiral CT. Because of this, performing several time scans is considered useful from the standpoint of reappearance of the section sensitivity profile curves. However, when examination is done at full width half maximum (FWHM) and the position of the center of FWHM, there is non-symmetry and the level of hem extent of the section sensitivity profile curves. Change in FWHM and the position of the center of FWHM increases as pitch increases. Although the change in FWHM was less when the reconstruction slice thickness was increased, the change became larger in the center of FWHM as well. As for the non-symmetry of the section sensitivity profile curves and the level of hem extent, the change decreased when the reconstruction slice thickness was increased, although it increased when pitch was enlarged. It is considered that the cause of these changes is change in table movement speed during scanning.</description><subject>Image Processing, Computer-Assisted - methods</subject><subject>Radiographic Image Enhancement - methods</subject><subject>Section sensitivity profile on Z-axis</subject><subject>Tomography, Spiral Computed - methods</subject><subject>X-ray computed tomograpby</subject><issn>0369-4305</issn><issn>1881-4883</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kMFu1DAURS0EoqPSH2CBvGKXYsdxYi_RiFKgFYjOio31xnnpeEjiYDuI-XsczaioLOqFn2ydc6V3CXnN2WXNmH6334d0-eUzW44uuWLiGVlxpXhRKSWekxUTtS4qweQZuYjRbRcuf7HqJTnjZQZrLVbk55UPA_2OME0IAUaL1Hc07ZDeoU3Oj3mO0SX326UD_RZ85_qMjPRHAX9cpG6kt3OfXNFiyoIP9G5yAXq69sM0J2zpxg_-PsC0O7wiLzroI16c5jnZXH3YrK-Lm68fP63f3xRWlEIUnNV1K1UJlWS1RqyqEiyzDcj8kKwtheZdB1vWIJe8QdBoy7ycqqzaChDn5O0xdgr-14wxmcFFi30PI_o5mkZIznmjM1geQRt8jAE7MwU3QDgYzsxSsllKNo9KztKbU_q8HbD9p5wqzYD6L9W6BEuVKYDrn86-Pqr7mOAeH7IhJGd7PCpSG7lcj9QHxO4gGBzFXyDNpRQ</recordid><startdate>200305</startdate><enddate>200305</enddate><creator>TACHIBANA, MASAYUKI</creator><general>Japanese Society of Radiological Technology</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200305</creationdate><title>Form Reappearance of the Section Sensitivity Profile on Z-axis in Multi-detector Spiral Computed Tomography</title><author>TACHIBANA, MASAYUKI</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3233-1066d582a45069ee442ac0c7a59ee50d2391ffab07e1517ea9ec200984c8b3a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; jpn</language><creationdate>2003</creationdate><topic>Image Processing, Computer-Assisted - methods</topic><topic>Radiographic Image Enhancement - methods</topic><topic>Section sensitivity profile on Z-axis</topic><topic>Tomography, Spiral Computed - methods</topic><topic>X-ray computed tomograpby</topic><toplevel>online_resources</toplevel><creatorcontrib>TACHIBANA, MASAYUKI</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Japanese Journal of Radiological Technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>TACHIBANA, MASAYUKI</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Form Reappearance of the Section Sensitivity Profile on Z-axis in Multi-detector Spiral Computed Tomography</atitle><jtitle>Japanese Journal of Radiological Technology</jtitle><addtitle>Jpn. J. Radiol. Technol.</addtitle><date>2003-05</date><risdate>2003</risdate><volume>59</volume><issue>5</issue><spage>627</spage><epage>631</epage><pages>627-631</pages><artnum>627</artnum><issn>0369-4305</issn><eissn>1881-4883</eissn><abstract>The filter is hung in the direction of slice thickness (Z-axis) in the reconstruction of multi-detector spiral CT. Because of this, performing several time scans is considered useful from the standpoint of reappearance of the section sensitivity profile curves. However, when examination is done at full width half maximum (FWHM) and the position of the center of FWHM, there is non-symmetry and the level of hem extent of the section sensitivity profile curves. Change in FWHM and the position of the center of FWHM increases as pitch increases. Although the change in FWHM was less when the reconstruction slice thickness was increased, the change became larger in the center of FWHM as well. As for the non-symmetry of the section sensitivity profile curves and the level of hem extent, the change decreased when the reconstruction slice thickness was increased, although it increased when pitch was enlarged. It is considered that the cause of these changes is change in table movement speed during scanning.</abstract><cop>Japan</cop><pub>Japanese Society of Radiological Technology</pub><pmid>12881693</pmid><doi>10.6009/jjrt.KJ00000921803</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0369-4305 |
ispartof | Japanese Journal of Radiological Technology, 2003/05/20, Vol.59(5), pp.627-631 |
issn | 0369-4305 1881-4883 |
language | eng ; jpn |
recordid | cdi_proquest_miscellaneous_73511179 |
source | MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals |
subjects | Image Processing, Computer-Assisted - methods Radiographic Image Enhancement - methods Section sensitivity profile on Z-axis Tomography, Spiral Computed - methods X-ray computed tomograpby |
title | Form Reappearance of the Section Sensitivity Profile on Z-axis in Multi-detector Spiral Computed Tomography |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T01%3A44%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Form%20Reappearance%20of%20the%20Section%20Sensitivity%20Profile%20on%20Z-axis%20in%20Multi-detector%20Spiral%20Computed%20Tomography&rft.jtitle=Japanese%20Journal%20of%20Radiological%20Technology&rft.au=TACHIBANA,%20MASAYUKI&rft.date=2003-05&rft.volume=59&rft.issue=5&rft.spage=627&rft.epage=631&rft.pages=627-631&rft.artnum=627&rft.issn=0369-4305&rft.eissn=1881-4883&rft_id=info:doi/10.6009/jjrt.KJ00000921803&rft_dat=%3Cproquest_cross%3E73511179%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73511179&rft_id=info:pmid/12881693&rfr_iscdi=true |