Effect of Rotational Speed on Root Canal Preparation with Hero 642 Rotary Ni-Ti Instruments

The purpose of this study was to evaluate the influence of Hero 642 rotary Ni-Ti instruments driven at 300, 400, or 600 rpm on root canal straightening, loss of working length, and instrument breakage. Sixty mesial root canals from extracted human mandibular molars were divided into 3 groups of 20 e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of endodontics 2003-07, Vol.29 (7), p.447-449
Hauptverfasser: Karagöz-Küçükay, Işıl, Ersev, Handan, Engin-Akkoca, Ece, Küçükay, Sedat, Gürsoy, Tankut
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 449
container_issue 7
container_start_page 447
container_title Journal of endodontics
container_volume 29
creator Karagöz-Küçükay, Işıl
Ersev, Handan
Engin-Akkoca, Ece
Küçükay, Sedat
Gürsoy, Tankut
description The purpose of this study was to evaluate the influence of Hero 642 rotary Ni-Ti instruments driven at 300, 400, or 600 rpm on root canal straightening, loss of working length, and instrument breakage. Sixty mesial root canals from extracted human mandibular molars were divided into 3 groups of 20 each and were instrumented at the aforementioned rotational speeds with a crown-down technique. Using a digital intraoral radiography system directly on the images of pre- and postoperative radiographs, degrees of canal curvatures were measured and recorded. Statistical analysis showed that final canal curvatures and working lengths were significantly reduced compared with those of original values in each group (p < 0.001). However, using Hero 642 rotary Ni-Ti system at different rotational speeds had no effect on canal curvature and working length alterations (p > 0.05). No file breakage was observed in any of the groups.
doi_str_mv 10.1097/00004770-200307000-00005
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73482326</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0099239905604062</els_id><sourcerecordid>73482326</sourcerecordid><originalsourceid>FETCH-LOGICAL-c370t-aa4d4db367ceb1e105d15e0169d914758aaf4502e53991422bc0a41063a16e4a3</originalsourceid><addsrcrecordid>eNqFkElPwzAQhS0EgrL8BeQTt8B4i5MjVECRECAoJw6Wm0yEURsX2wXx73EX4IgvIz99b5ZHCGVwyqDWZ5Cf1BoKDiBA51-xlNQWGbBKV4VQSm6TAUBdF1zU9R7Zj_ENgGkh9C7ZY7zSmpcwIC-XXYdNor6jjz7Z5Hxvp_RpjthS32fNJzq0S-0h4NyGFUE_XXqlIwyelpKvjOGL3rli7OhNH1NYzLBP8ZDsdHYa8WhTD8jz1eV4OCpu769vhue3RSM0pMJa2cp2Ikrd4IQhA9UyhcDKuq2Z1KqytpMKOKp8CZOcTxqwkkEpLCtRWnFATtZ958G_LzAmM3OxwenU9ugX0WghKy54mcFqDTbBxxiwM_PgZnl3w8AsgzU_wZrfYFeSytbjzYzFZIbtn3GTZAYu1gDmSz8cBhMbh32DrQs5YNN69_-Ub3fnheA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73482326</pqid></control><display><type>article</type><title>Effect of Rotational Speed on Root Canal Preparation with Hero 642 Rotary Ni-Ti Instruments</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Karagöz-Küçükay, Işıl ; Ersev, Handan ; Engin-Akkoca, Ece ; Küçükay, Sedat ; Gürsoy, Tankut</creator><creatorcontrib>Karagöz-Küçükay, Işıl ; Ersev, Handan ; Engin-Akkoca, Ece ; Küçükay, Sedat ; Gürsoy, Tankut</creatorcontrib><description>The purpose of this study was to evaluate the influence of Hero 642 rotary Ni-Ti instruments driven at 300, 400, or 600 rpm on root canal straightening, loss of working length, and instrument breakage. Sixty mesial root canals from extracted human mandibular molars were divided into 3 groups of 20 each and were instrumented at the aforementioned rotational speeds with a crown-down technique. Using a digital intraoral radiography system directly on the images of pre- and postoperative radiographs, degrees of canal curvatures were measured and recorded. Statistical analysis showed that final canal curvatures and working lengths were significantly reduced compared with those of original values in each group (p &lt; 0.001). However, using Hero 642 rotary Ni-Ti system at different rotational speeds had no effect on canal curvature and working length alterations (p &gt; 0.05). No file breakage was observed in any of the groups.</description><identifier>ISSN: 0099-2399</identifier><identifier>EISSN: 1878-3554</identifier><identifier>DOI: 10.1097/00004770-200307000-00005</identifier><identifier>PMID: 12877260</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Dental Alloys ; Dental Instruments ; Dental Pulp Cavity - anatomy &amp; histology ; Dental Pulp Cavity - diagnostic imaging ; Dentistry ; Humans ; Molar ; Nickel ; Radiography, Dental, Digital ; Root Canal Preparation - instrumentation ; Rotation ; Titanium</subject><ispartof>Journal of endodontics, 2003-07, Vol.29 (7), p.447-449</ispartof><rights>2003 The American Association of Endodontists</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c370t-aa4d4db367ceb1e105d15e0169d914758aaf4502e53991422bc0a41063a16e4a3</citedby><cites>FETCH-LOGICAL-c370t-aa4d4db367ceb1e105d15e0169d914758aaf4502e53991422bc0a41063a16e4a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1097/00004770-200307000-00005$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12877260$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Karagöz-Küçükay, Işıl</creatorcontrib><creatorcontrib>Ersev, Handan</creatorcontrib><creatorcontrib>Engin-Akkoca, Ece</creatorcontrib><creatorcontrib>Küçükay, Sedat</creatorcontrib><creatorcontrib>Gürsoy, Tankut</creatorcontrib><title>Effect of Rotational Speed on Root Canal Preparation with Hero 642 Rotary Ni-Ti Instruments</title><title>Journal of endodontics</title><addtitle>J Endod</addtitle><description>The purpose of this study was to evaluate the influence of Hero 642 rotary Ni-Ti instruments driven at 300, 400, or 600 rpm on root canal straightening, loss of working length, and instrument breakage. Sixty mesial root canals from extracted human mandibular molars were divided into 3 groups of 20 each and were instrumented at the aforementioned rotational speeds with a crown-down technique. Using a digital intraoral radiography system directly on the images of pre- and postoperative radiographs, degrees of canal curvatures were measured and recorded. Statistical analysis showed that final canal curvatures and working lengths were significantly reduced compared with those of original values in each group (p &lt; 0.001). However, using Hero 642 rotary Ni-Ti system at different rotational speeds had no effect on canal curvature and working length alterations (p &gt; 0.05). No file breakage was observed in any of the groups.</description><subject>Dental Alloys</subject><subject>Dental Instruments</subject><subject>Dental Pulp Cavity - anatomy &amp; histology</subject><subject>Dental Pulp Cavity - diagnostic imaging</subject><subject>Dentistry</subject><subject>Humans</subject><subject>Molar</subject><subject>Nickel</subject><subject>Radiography, Dental, Digital</subject><subject>Root Canal Preparation - instrumentation</subject><subject>Rotation</subject><subject>Titanium</subject><issn>0099-2399</issn><issn>1878-3554</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkElPwzAQhS0EgrL8BeQTt8B4i5MjVECRECAoJw6Wm0yEURsX2wXx73EX4IgvIz99b5ZHCGVwyqDWZ5Cf1BoKDiBA51-xlNQWGbBKV4VQSm6TAUBdF1zU9R7Zj_ENgGkh9C7ZY7zSmpcwIC-XXYdNor6jjz7Z5Hxvp_RpjthS32fNJzq0S-0h4NyGFUE_XXqlIwyelpKvjOGL3rli7OhNH1NYzLBP8ZDsdHYa8WhTD8jz1eV4OCpu769vhue3RSM0pMJa2cp2Ikrd4IQhA9UyhcDKuq2Z1KqytpMKOKp8CZOcTxqwkkEpLCtRWnFATtZ958G_LzAmM3OxwenU9ugX0WghKy54mcFqDTbBxxiwM_PgZnl3w8AsgzU_wZrfYFeSytbjzYzFZIbtn3GTZAYu1gDmSz8cBhMbh32DrQs5YNN69_-Ub3fnheA</recordid><startdate>20030701</startdate><enddate>20030701</enddate><creator>Karagöz-Küçükay, Işıl</creator><creator>Ersev, Handan</creator><creator>Engin-Akkoca, Ece</creator><creator>Küçükay, Sedat</creator><creator>Gürsoy, Tankut</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20030701</creationdate><title>Effect of Rotational Speed on Root Canal Preparation with Hero 642 Rotary Ni-Ti Instruments</title><author>Karagöz-Küçükay, Işıl ; Ersev, Handan ; Engin-Akkoca, Ece ; Küçükay, Sedat ; Gürsoy, Tankut</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c370t-aa4d4db367ceb1e105d15e0169d914758aaf4502e53991422bc0a41063a16e4a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Dental Alloys</topic><topic>Dental Instruments</topic><topic>Dental Pulp Cavity - anatomy &amp; histology</topic><topic>Dental Pulp Cavity - diagnostic imaging</topic><topic>Dentistry</topic><topic>Humans</topic><topic>Molar</topic><topic>Nickel</topic><topic>Radiography, Dental, Digital</topic><topic>Root Canal Preparation - instrumentation</topic><topic>Rotation</topic><topic>Titanium</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Karagöz-Küçükay, Işıl</creatorcontrib><creatorcontrib>Ersev, Handan</creatorcontrib><creatorcontrib>Engin-Akkoca, Ece</creatorcontrib><creatorcontrib>Küçükay, Sedat</creatorcontrib><creatorcontrib>Gürsoy, Tankut</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of endodontics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Karagöz-Küçükay, Işıl</au><au>Ersev, Handan</au><au>Engin-Akkoca, Ece</au><au>Küçükay, Sedat</au><au>Gürsoy, Tankut</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of Rotational Speed on Root Canal Preparation with Hero 642 Rotary Ni-Ti Instruments</atitle><jtitle>Journal of endodontics</jtitle><addtitle>J Endod</addtitle><date>2003-07-01</date><risdate>2003</risdate><volume>29</volume><issue>7</issue><spage>447</spage><epage>449</epage><pages>447-449</pages><issn>0099-2399</issn><eissn>1878-3554</eissn><abstract>The purpose of this study was to evaluate the influence of Hero 642 rotary Ni-Ti instruments driven at 300, 400, or 600 rpm on root canal straightening, loss of working length, and instrument breakage. Sixty mesial root canals from extracted human mandibular molars were divided into 3 groups of 20 each and were instrumented at the aforementioned rotational speeds with a crown-down technique. Using a digital intraoral radiography system directly on the images of pre- and postoperative radiographs, degrees of canal curvatures were measured and recorded. Statistical analysis showed that final canal curvatures and working lengths were significantly reduced compared with those of original values in each group (p &lt; 0.001). However, using Hero 642 rotary Ni-Ti system at different rotational speeds had no effect on canal curvature and working length alterations (p &gt; 0.05). No file breakage was observed in any of the groups.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>12877260</pmid><doi>10.1097/00004770-200307000-00005</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0099-2399
ispartof Journal of endodontics, 2003-07, Vol.29 (7), p.447-449
issn 0099-2399
1878-3554
language eng
recordid cdi_proquest_miscellaneous_73482326
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects Dental Alloys
Dental Instruments
Dental Pulp Cavity - anatomy & histology
Dental Pulp Cavity - diagnostic imaging
Dentistry
Humans
Molar
Nickel
Radiography, Dental, Digital
Root Canal Preparation - instrumentation
Rotation
Titanium
title Effect of Rotational Speed on Root Canal Preparation with Hero 642 Rotary Ni-Ti Instruments
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T16%3A43%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20Rotational%20Speed%20on%20Root%20Canal%20Preparation%20with%20Hero%20642%20Rotary%20Ni-Ti%20Instruments&rft.jtitle=Journal%20of%20endodontics&rft.au=Karag%C3%B6z-K%C3%BC%C3%A7%C3%BCkay,%20I%C5%9F%C4%B1l&rft.date=2003-07-01&rft.volume=29&rft.issue=7&rft.spage=447&rft.epage=449&rft.pages=447-449&rft.issn=0099-2399&rft.eissn=1878-3554&rft_id=info:doi/10.1097/00004770-200307000-00005&rft_dat=%3Cproquest_cross%3E73482326%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73482326&rft_id=info:pmid/12877260&rft_els_id=S0099239905604062&rfr_iscdi=true