Minimally ischemic off-pump coronary artery bypass grafting: active perfusion-assist with nitroglycerin-supplemented blood

During off-pump coronary artery bypass surgery, concern remains about possible myocardial injury associated with the transient occlusion and stabilization of the target vessels. To try to minimize myocardial ischemia and achieve hemodynamic stability, we used a coronary perfusion catheter combined w...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 2003-07, Vol.76 (1), p.298-300
Hauptverfasser: Muraki, Satoshi, Tsukamoto, Masaru, Komatsu, Kanshi, Sakata, Jyunichi, Ohori, Syunsuke, Hasegawa, Takeo, Abe, Tomio
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 300
container_issue 1
container_start_page 298
container_title The Annals of thoracic surgery
container_volume 76
creator Muraki, Satoshi
Tsukamoto, Masaru
Komatsu, Kanshi
Sakata, Jyunichi
Ohori, Syunsuke
Hasegawa, Takeo
Abe, Tomio
description During off-pump coronary artery bypass surgery, concern remains about possible myocardial injury associated with the transient occlusion and stabilization of the target vessels. To try to minimize myocardial ischemia and achieve hemodynamic stability, we used a coronary perfusion catheter combined with the perfusion-assisted direct coronary artery bypass system, which enables active and modified coronary perfusion of the target vessel throughout the duration of multiple grafting.
doi_str_mv 10.1016/S0003-4975(02)04895-6
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73434107</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003497502048956</els_id><sourcerecordid>73434107</sourcerecordid><originalsourceid>FETCH-LOGICAL-c473t-5c908749d033d8a82423d7cb841da5085e9b7e477282ab86c72dcf30cc4525f03</originalsourceid><addsrcrecordid>eNqFkMtu1TAQQC0EoreFTwB5AyqLgO3YsdMNQhUvqYgFsLYce3JrlNjBdorC1-P2XtElq9FozrwOQs8oeU0J7d58I4S0De-lOCfsFeGqF033AO2oEKzpmOgfot0_5ASd5vyzpqyWH6MTyhRnQtId-vPFBz-badqwz_YaZm9xHMdmWecF25hiMGnDJhWoYdgWkzPeJzMWH_YX2NjibwAvkMY1-xiaWva54N--XOPgS4r7abOQfGjyuiwTzBAKODxMMbon6NFopgxPj_EM_fjw_vvlp-bq68fPl--uGstlWxphe6Ik7x1pW6eMYpy1TtpBceqMIEpAP0jgUjLFzKA6K5mzY0us5YKJkbRn6OVh7pLirxVy0XN9FabJBIhr1rLlLadEVlAcQJtizglGvaTqJm2aEn0rXd9J17dGNWH6Trruat_z44J1mMHddx0tV-DFETDZmmlMJlif7zneK9JxXrm3Bw6qjhsPSWfrIVhwPoEt2kX_n1P-AtCqoQ4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73434107</pqid></control><display><type>article</type><title>Minimally ischemic off-pump coronary artery bypass grafting: active perfusion-assist with nitroglycerin-supplemented blood</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>Muraki, Satoshi ; Tsukamoto, Masaru ; Komatsu, Kanshi ; Sakata, Jyunichi ; Ohori, Syunsuke ; Hasegawa, Takeo ; Abe, Tomio</creator><creatorcontrib>Muraki, Satoshi ; Tsukamoto, Masaru ; Komatsu, Kanshi ; Sakata, Jyunichi ; Ohori, Syunsuke ; Hasegawa, Takeo ; Abe, Tomio</creatorcontrib><description>During off-pump coronary artery bypass surgery, concern remains about possible myocardial injury associated with the transient occlusion and stabilization of the target vessels. To try to minimize myocardial ischemia and achieve hemodynamic stability, we used a coronary perfusion catheter combined with the perfusion-assisted direct coronary artery bypass system, which enables active and modified coronary perfusion of the target vessel throughout the duration of multiple grafting.</description><identifier>ISSN: 0003-4975</identifier><identifier>EISSN: 1552-6259</identifier><identifier>DOI: 10.1016/S0003-4975(02)04895-6</identifier><identifier>PMID: 12842571</identifier><identifier>CODEN: ATHSAK</identifier><language>eng</language><publisher>New York, NY: Elsevier Inc</publisher><subject>Biological and medical sciences ; Coronary Artery Bypass - methods ; Coronary Disease - diagnosis ; Coronary Disease - surgery ; Coronary Vessels - drug effects ; Female ; Follow-Up Studies ; Graft Occlusion, Vascular - prevention &amp; control ; Graft Rejection ; Graft Survival ; Heart-Lung Machine ; Hemodynamics - physiology ; Humans ; Male ; Medical sciences ; Minimally Invasive Surgical Procedures - methods ; Myocardial Reperfusion Injury - prevention &amp; control ; Nitroglycerin - administration &amp; dosage ; Perfusion - methods ; Risk Assessment ; Sampling Studies ; Treatment Outcome ; Vascular Patency - physiology</subject><ispartof>The Annals of thoracic surgery, 2003-07, Vol.76 (1), p.298-300</ispartof><rights>2003 The Society of Thoracic Surgeons</rights><rights>2003 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c473t-5c908749d033d8a82423d7cb841da5085e9b7e477282ab86c72dcf30cc4525f03</citedby><cites>FETCH-LOGICAL-c473t-5c908749d033d8a82423d7cb841da5085e9b7e477282ab86c72dcf30cc4525f03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0003-4975(02)04895-6$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=14980644$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12842571$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Muraki, Satoshi</creatorcontrib><creatorcontrib>Tsukamoto, Masaru</creatorcontrib><creatorcontrib>Komatsu, Kanshi</creatorcontrib><creatorcontrib>Sakata, Jyunichi</creatorcontrib><creatorcontrib>Ohori, Syunsuke</creatorcontrib><creatorcontrib>Hasegawa, Takeo</creatorcontrib><creatorcontrib>Abe, Tomio</creatorcontrib><title>Minimally ischemic off-pump coronary artery bypass grafting: active perfusion-assist with nitroglycerin-supplemented blood</title><title>The Annals of thoracic surgery</title><addtitle>Ann Thorac Surg</addtitle><description>During off-pump coronary artery bypass surgery, concern remains about possible myocardial injury associated with the transient occlusion and stabilization of the target vessels. To try to minimize myocardial ischemia and achieve hemodynamic stability, we used a coronary perfusion catheter combined with the perfusion-assisted direct coronary artery bypass system, which enables active and modified coronary perfusion of the target vessel throughout the duration of multiple grafting.</description><subject>Biological and medical sciences</subject><subject>Coronary Artery Bypass - methods</subject><subject>Coronary Disease - diagnosis</subject><subject>Coronary Disease - surgery</subject><subject>Coronary Vessels - drug effects</subject><subject>Female</subject><subject>Follow-Up Studies</subject><subject>Graft Occlusion, Vascular - prevention &amp; control</subject><subject>Graft Rejection</subject><subject>Graft Survival</subject><subject>Heart-Lung Machine</subject><subject>Hemodynamics - physiology</subject><subject>Humans</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Minimally Invasive Surgical Procedures - methods</subject><subject>Myocardial Reperfusion Injury - prevention &amp; control</subject><subject>Nitroglycerin - administration &amp; dosage</subject><subject>Perfusion - methods</subject><subject>Risk Assessment</subject><subject>Sampling Studies</subject><subject>Treatment Outcome</subject><subject>Vascular Patency - physiology</subject><issn>0003-4975</issn><issn>1552-6259</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkMtu1TAQQC0EoreFTwB5AyqLgO3YsdMNQhUvqYgFsLYce3JrlNjBdorC1-P2XtElq9FozrwOQs8oeU0J7d58I4S0De-lOCfsFeGqF033AO2oEKzpmOgfot0_5ASd5vyzpqyWH6MTyhRnQtId-vPFBz-badqwz_YaZm9xHMdmWecF25hiMGnDJhWoYdgWkzPeJzMWH_YX2NjibwAvkMY1-xiaWva54N--XOPgS4r7abOQfGjyuiwTzBAKODxMMbon6NFopgxPj_EM_fjw_vvlp-bq68fPl--uGstlWxphe6Ik7x1pW6eMYpy1TtpBceqMIEpAP0jgUjLFzKA6K5mzY0us5YKJkbRn6OVh7pLirxVy0XN9FabJBIhr1rLlLadEVlAcQJtizglGvaTqJm2aEn0rXd9J17dGNWH6Trruat_z44J1mMHddx0tV-DFETDZmmlMJlif7zneK9JxXrm3Bw6qjhsPSWfrIVhwPoEt2kX_n1P-AtCqoQ4</recordid><startdate>20030701</startdate><enddate>20030701</enddate><creator>Muraki, Satoshi</creator><creator>Tsukamoto, Masaru</creator><creator>Komatsu, Kanshi</creator><creator>Sakata, Jyunichi</creator><creator>Ohori, Syunsuke</creator><creator>Hasegawa, Takeo</creator><creator>Abe, Tomio</creator><general>Elsevier Inc</general><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20030701</creationdate><title>Minimally ischemic off-pump coronary artery bypass grafting: active perfusion-assist with nitroglycerin-supplemented blood</title><author>Muraki, Satoshi ; Tsukamoto, Masaru ; Komatsu, Kanshi ; Sakata, Jyunichi ; Ohori, Syunsuke ; Hasegawa, Takeo ; Abe, Tomio</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c473t-5c908749d033d8a82423d7cb841da5085e9b7e477282ab86c72dcf30cc4525f03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Biological and medical sciences</topic><topic>Coronary Artery Bypass - methods</topic><topic>Coronary Disease - diagnosis</topic><topic>Coronary Disease - surgery</topic><topic>Coronary Vessels - drug effects</topic><topic>Female</topic><topic>Follow-Up Studies</topic><topic>Graft Occlusion, Vascular - prevention &amp; control</topic><topic>Graft Rejection</topic><topic>Graft Survival</topic><topic>Heart-Lung Machine</topic><topic>Hemodynamics - physiology</topic><topic>Humans</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Minimally Invasive Surgical Procedures - methods</topic><topic>Myocardial Reperfusion Injury - prevention &amp; control</topic><topic>Nitroglycerin - administration &amp; dosage</topic><topic>Perfusion - methods</topic><topic>Risk Assessment</topic><topic>Sampling Studies</topic><topic>Treatment Outcome</topic><topic>Vascular Patency - physiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Muraki, Satoshi</creatorcontrib><creatorcontrib>Tsukamoto, Masaru</creatorcontrib><creatorcontrib>Komatsu, Kanshi</creatorcontrib><creatorcontrib>Sakata, Jyunichi</creatorcontrib><creatorcontrib>Ohori, Syunsuke</creatorcontrib><creatorcontrib>Hasegawa, Takeo</creatorcontrib><creatorcontrib>Abe, Tomio</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Annals of thoracic surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Muraki, Satoshi</au><au>Tsukamoto, Masaru</au><au>Komatsu, Kanshi</au><au>Sakata, Jyunichi</au><au>Ohori, Syunsuke</au><au>Hasegawa, Takeo</au><au>Abe, Tomio</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Minimally ischemic off-pump coronary artery bypass grafting: active perfusion-assist with nitroglycerin-supplemented blood</atitle><jtitle>The Annals of thoracic surgery</jtitle><addtitle>Ann Thorac Surg</addtitle><date>2003-07-01</date><risdate>2003</risdate><volume>76</volume><issue>1</issue><spage>298</spage><epage>300</epage><pages>298-300</pages><issn>0003-4975</issn><eissn>1552-6259</eissn><coden>ATHSAK</coden><abstract>During off-pump coronary artery bypass surgery, concern remains about possible myocardial injury associated with the transient occlusion and stabilization of the target vessels. To try to minimize myocardial ischemia and achieve hemodynamic stability, we used a coronary perfusion catheter combined with the perfusion-assisted direct coronary artery bypass system, which enables active and modified coronary perfusion of the target vessel throughout the duration of multiple grafting.</abstract><cop>New York, NY</cop><pub>Elsevier Inc</pub><pmid>12842571</pmid><doi>10.1016/S0003-4975(02)04895-6</doi><tpages>3</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0003-4975
ispartof The Annals of thoracic surgery, 2003-07, Vol.76 (1), p.298-300
issn 0003-4975
1552-6259
language eng
recordid cdi_proquest_miscellaneous_73434107
source MEDLINE; Access via ScienceDirect (Elsevier); EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection
subjects Biological and medical sciences
Coronary Artery Bypass - methods
Coronary Disease - diagnosis
Coronary Disease - surgery
Coronary Vessels - drug effects
Female
Follow-Up Studies
Graft Occlusion, Vascular - prevention & control
Graft Rejection
Graft Survival
Heart-Lung Machine
Hemodynamics - physiology
Humans
Male
Medical sciences
Minimally Invasive Surgical Procedures - methods
Myocardial Reperfusion Injury - prevention & control
Nitroglycerin - administration & dosage
Perfusion - methods
Risk Assessment
Sampling Studies
Treatment Outcome
Vascular Patency - physiology
title Minimally ischemic off-pump coronary artery bypass grafting: active perfusion-assist with nitroglycerin-supplemented blood
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T22%3A24%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Minimally%20ischemic%20off-pump%20coronary%20artery%20bypass%20grafting:%20active%20perfusion-assist%20with%20nitroglycerin-supplemented%20blood&rft.jtitle=The%20Annals%20of%20thoracic%20surgery&rft.au=Muraki,%20Satoshi&rft.date=2003-07-01&rft.volume=76&rft.issue=1&rft.spage=298&rft.epage=300&rft.pages=298-300&rft.issn=0003-4975&rft.eissn=1552-6259&rft.coden=ATHSAK&rft_id=info:doi/10.1016/S0003-4975(02)04895-6&rft_dat=%3Cproquest_cross%3E73434107%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73434107&rft_id=info:pmid/12842571&rft_els_id=S0003497502048956&rfr_iscdi=true