Comparative evaluation of the swelling and degrees of cross-linking in three organic gel packings for SEC through some geometric parameters

The size exclusion chromatographic (SEC) behavior of five solvent/polymer systems in three organic column packings based on polystyrene/divinylbenzene (PS/DVB) copolymer, TSK-Gel H HR, μ-styragel and TSK-Gel H XL, has been compared. All the packings offer similar characteristics (pore size, particle...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of biochemical and biophysical methods 2003-06, Vol.56 (1), p.53-67
Hauptverfasser: Garcı́a, Rosa, Gómez, Clara M, Codoñer, Armando, Abad, Concepción, Campos, Agustı́n
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 67
container_issue 1
container_start_page 53
container_title Journal of biochemical and biophysical methods
container_volume 56
creator Garcı́a, Rosa
Gómez, Clara M
Codoñer, Armando
Abad, Concepción
Campos, Agustı́n
description The size exclusion chromatographic (SEC) behavior of five solvent/polymer systems in three organic column packings based on polystyrene/divinylbenzene (PS/DVB) copolymer, TSK-Gel H HR, μ-styragel and TSK-Gel H XL, has been compared. All the packings offer similar characteristics (pore size, particle size and efficiency) but some differences have been found when eluting the same systems. The different elution behavior observed in both polymeric gels has been analyzed in terms of their swelling and cross-linking degrees and of the fractal parameters. From the Universal Calibration plots, values of the chromatographic partition coefficient, K p, have been obtained and using some equations previously reported, values of the volume fraction of the network in the swollen state have been determined for the three sets of columns. Overall, for a given hydrodynamic volume and solvent-polymeric solute system the fraction of cross-linked polymer in the stationary phase was ordered according to: TSK-Gel H XL>μ-styragel>TSK-Gel H HR. This means an enhanced swelling degree for TSK-Gel H HR. In general, fractal calculations support the thermodynamic predictions since both the fractal dimension and the pore size can be ordered as TSK-Gel H HR>μ-styragel>TSK-Gel H XL (in 10 of the 15 situations studied). The exceptions can be explained in terms of strong preferential solvation.
doi_str_mv 10.1016/S0165-022X(03)00072-1
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73425830</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0165022X03000721</els_id><sourcerecordid>73425830</sourcerecordid><originalsourceid>FETCH-LOGICAL-c363t-87d9b29836db4aacd3fde0a6d85eebf132a0f1ce857e3acf14ce3f00fcf279c83</originalsourceid><addsrcrecordid>eNqFkctOHDEQRa0oUZiQfEIir6KwaOJHPzwrhEaQREJiQSKxszx2uXHobg9296B8Q36a6pkRLNmUS7qnfFV1CfnM2SlnvP5-g6UqmBC335g8YYw1ouBvyIIrbFTV3L4li2fkiHzI-S9CUonyPTniQslyWasF-b-K_cYkM4YtUNiabsI2DjR6Ot4BzY_QdWFoqRkcddAmgDxrNsWcC1TuZzEMCKNEY2rNECxtoaMbY2cxUx8TvblYzUic2juaYw9IYB0TsrM7tpDyR_LOmy7Dp8N7TP5cXvxe_Syurn_8Wp1fFVbWcixU45ZrsVSyduvSGOukd8BM7VQFsPZcCsM8t4BHAGms56UF6Rnz1otmaZU8Jl_3_25SfJggj7oP2eKiZoA4Zd3IUlRKMgSrPbhbN4HXmxR6k_5pzvScgt6loOcTayb1LgXNce7LwWBa9-Bepg5nR-BsDwCuuQ2QdLYBBgsuJLCjdjG8YvEEYuubcQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73425830</pqid></control><display><type>article</type><title>Comparative evaluation of the swelling and degrees of cross-linking in three organic gel packings for SEC through some geometric parameters</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Garcı́a, Rosa ; Gómez, Clara M ; Codoñer, Armando ; Abad, Concepción ; Campos, Agustı́n</creator><creatorcontrib>Garcı́a, Rosa ; Gómez, Clara M ; Codoñer, Armando ; Abad, Concepción ; Campos, Agustı́n</creatorcontrib><description>The size exclusion chromatographic (SEC) behavior of five solvent/polymer systems in three organic column packings based on polystyrene/divinylbenzene (PS/DVB) copolymer, TSK-Gel H HR, μ-styragel and TSK-Gel H XL, has been compared. All the packings offer similar characteristics (pore size, particle size and efficiency) but some differences have been found when eluting the same systems. The different elution behavior observed in both polymeric gels has been analyzed in terms of their swelling and cross-linking degrees and of the fractal parameters. From the Universal Calibration plots, values of the chromatographic partition coefficient, K p, have been obtained and using some equations previously reported, values of the volume fraction of the network in the swollen state have been determined for the three sets of columns. Overall, for a given hydrodynamic volume and solvent-polymeric solute system the fraction of cross-linked polymer in the stationary phase was ordered according to: TSK-Gel H XL&gt;μ-styragel&gt;TSK-Gel H HR. This means an enhanced swelling degree for TSK-Gel H HR. In general, fractal calculations support the thermodynamic predictions since both the fractal dimension and the pore size can be ordered as TSK-Gel H HR&gt;μ-styragel&gt;TSK-Gel H XL (in 10 of the 15 situations studied). The exceptions can be explained in terms of strong preferential solvation.</description><identifier>ISSN: 0165-022X</identifier><identifier>EISSN: 1872-857X</identifier><identifier>DOI: 10.1016/S0165-022X(03)00072-1</identifier><identifier>PMID: 12834968</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Calibration ; Chromatography, Gel - instrumentation ; Chromatography, Gel - methods ; Cross-Linking Reagents - chemistry ; Equipment Failure Analysis ; Fractal behavior ; Gels - chemistry ; Macromolecular Substances ; Materials Testing - methods ; Molecular Conformation ; Organic Chemicals - chemistry ; Particle Size ; Porosity ; Size exclusion chromatography ; Swelling and cross-linking degree ; Viscosity</subject><ispartof>Journal of biochemical and biophysical methods, 2003-06, Vol.56 (1), p.53-67</ispartof><rights>2003 Elsevier Science B.V.</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c363t-87d9b29836db4aacd3fde0a6d85eebf132a0f1ce857e3acf14ce3f00fcf279c83</citedby><cites>FETCH-LOGICAL-c363t-87d9b29836db4aacd3fde0a6d85eebf132a0f1ce857e3acf14ce3f00fcf279c83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12834968$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Garcı́a, Rosa</creatorcontrib><creatorcontrib>Gómez, Clara M</creatorcontrib><creatorcontrib>Codoñer, Armando</creatorcontrib><creatorcontrib>Abad, Concepción</creatorcontrib><creatorcontrib>Campos, Agustı́n</creatorcontrib><title>Comparative evaluation of the swelling and degrees of cross-linking in three organic gel packings for SEC through some geometric parameters</title><title>Journal of biochemical and biophysical methods</title><addtitle>J Biochem Biophys Methods</addtitle><description>The size exclusion chromatographic (SEC) behavior of five solvent/polymer systems in three organic column packings based on polystyrene/divinylbenzene (PS/DVB) copolymer, TSK-Gel H HR, μ-styragel and TSK-Gel H XL, has been compared. All the packings offer similar characteristics (pore size, particle size and efficiency) but some differences have been found when eluting the same systems. The different elution behavior observed in both polymeric gels has been analyzed in terms of their swelling and cross-linking degrees and of the fractal parameters. From the Universal Calibration plots, values of the chromatographic partition coefficient, K p, have been obtained and using some equations previously reported, values of the volume fraction of the network in the swollen state have been determined for the three sets of columns. Overall, for a given hydrodynamic volume and solvent-polymeric solute system the fraction of cross-linked polymer in the stationary phase was ordered according to: TSK-Gel H XL&gt;μ-styragel&gt;TSK-Gel H HR. This means an enhanced swelling degree for TSK-Gel H HR. In general, fractal calculations support the thermodynamic predictions since both the fractal dimension and the pore size can be ordered as TSK-Gel H HR&gt;μ-styragel&gt;TSK-Gel H XL (in 10 of the 15 situations studied). The exceptions can be explained in terms of strong preferential solvation.</description><subject>Calibration</subject><subject>Chromatography, Gel - instrumentation</subject><subject>Chromatography, Gel - methods</subject><subject>Cross-Linking Reagents - chemistry</subject><subject>Equipment Failure Analysis</subject><subject>Fractal behavior</subject><subject>Gels - chemistry</subject><subject>Macromolecular Substances</subject><subject>Materials Testing - methods</subject><subject>Molecular Conformation</subject><subject>Organic Chemicals - chemistry</subject><subject>Particle Size</subject><subject>Porosity</subject><subject>Size exclusion chromatography</subject><subject>Swelling and cross-linking degree</subject><subject>Viscosity</subject><issn>0165-022X</issn><issn>1872-857X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkctOHDEQRa0oUZiQfEIir6KwaOJHPzwrhEaQREJiQSKxszx2uXHobg9296B8Q36a6pkRLNmUS7qnfFV1CfnM2SlnvP5-g6UqmBC335g8YYw1ouBvyIIrbFTV3L4li2fkiHzI-S9CUonyPTniQslyWasF-b-K_cYkM4YtUNiabsI2DjR6Ot4BzY_QdWFoqRkcddAmgDxrNsWcC1TuZzEMCKNEY2rNECxtoaMbY2cxUx8TvblYzUic2juaYw9IYB0TsrM7tpDyR_LOmy7Dp8N7TP5cXvxe_Syurn_8Wp1fFVbWcixU45ZrsVSyduvSGOukd8BM7VQFsPZcCsM8t4BHAGms56UF6Rnz1otmaZU8Jl_3_25SfJggj7oP2eKiZoA4Zd3IUlRKMgSrPbhbN4HXmxR6k_5pzvScgt6loOcTayb1LgXNce7LwWBa9-Bepg5nR-BsDwCuuQ2QdLYBBgsuJLCjdjG8YvEEYuubcQ</recordid><startdate>20030630</startdate><enddate>20030630</enddate><creator>Garcı́a, Rosa</creator><creator>Gómez, Clara M</creator><creator>Codoñer, Armando</creator><creator>Abad, Concepción</creator><creator>Campos, Agustı́n</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20030630</creationdate><title>Comparative evaluation of the swelling and degrees of cross-linking in three organic gel packings for SEC through some geometric parameters</title><author>Garcı́a, Rosa ; Gómez, Clara M ; Codoñer, Armando ; Abad, Concepción ; Campos, Agustı́n</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c363t-87d9b29836db4aacd3fde0a6d85eebf132a0f1ce857e3acf14ce3f00fcf279c83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Calibration</topic><topic>Chromatography, Gel - instrumentation</topic><topic>Chromatography, Gel - methods</topic><topic>Cross-Linking Reagents - chemistry</topic><topic>Equipment Failure Analysis</topic><topic>Fractal behavior</topic><topic>Gels - chemistry</topic><topic>Macromolecular Substances</topic><topic>Materials Testing - methods</topic><topic>Molecular Conformation</topic><topic>Organic Chemicals - chemistry</topic><topic>Particle Size</topic><topic>Porosity</topic><topic>Size exclusion chromatography</topic><topic>Swelling and cross-linking degree</topic><topic>Viscosity</topic><toplevel>online_resources</toplevel><creatorcontrib>Garcı́a, Rosa</creatorcontrib><creatorcontrib>Gómez, Clara M</creatorcontrib><creatorcontrib>Codoñer, Armando</creatorcontrib><creatorcontrib>Abad, Concepción</creatorcontrib><creatorcontrib>Campos, Agustı́n</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of biochemical and biophysical methods</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Garcı́a, Rosa</au><au>Gómez, Clara M</au><au>Codoñer, Armando</au><au>Abad, Concepción</au><au>Campos, Agustı́n</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparative evaluation of the swelling and degrees of cross-linking in three organic gel packings for SEC through some geometric parameters</atitle><jtitle>Journal of biochemical and biophysical methods</jtitle><addtitle>J Biochem Biophys Methods</addtitle><date>2003-06-30</date><risdate>2003</risdate><volume>56</volume><issue>1</issue><spage>53</spage><epage>67</epage><pages>53-67</pages><issn>0165-022X</issn><eissn>1872-857X</eissn><abstract>The size exclusion chromatographic (SEC) behavior of five solvent/polymer systems in three organic column packings based on polystyrene/divinylbenzene (PS/DVB) copolymer, TSK-Gel H HR, μ-styragel and TSK-Gel H XL, has been compared. All the packings offer similar characteristics (pore size, particle size and efficiency) but some differences have been found when eluting the same systems. The different elution behavior observed in both polymeric gels has been analyzed in terms of their swelling and cross-linking degrees and of the fractal parameters. From the Universal Calibration plots, values of the chromatographic partition coefficient, K p, have been obtained and using some equations previously reported, values of the volume fraction of the network in the swollen state have been determined for the three sets of columns. Overall, for a given hydrodynamic volume and solvent-polymeric solute system the fraction of cross-linked polymer in the stationary phase was ordered according to: TSK-Gel H XL&gt;μ-styragel&gt;TSK-Gel H HR. This means an enhanced swelling degree for TSK-Gel H HR. In general, fractal calculations support the thermodynamic predictions since both the fractal dimension and the pore size can be ordered as TSK-Gel H HR&gt;μ-styragel&gt;TSK-Gel H XL (in 10 of the 15 situations studied). The exceptions can be explained in terms of strong preferential solvation.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>12834968</pmid><doi>10.1016/S0165-022X(03)00072-1</doi><tpages>15</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0165-022X
ispartof Journal of biochemical and biophysical methods, 2003-06, Vol.56 (1), p.53-67
issn 0165-022X
1872-857X
language eng
recordid cdi_proquest_miscellaneous_73425830
source MEDLINE; Alma/SFX Local Collection
subjects Calibration
Chromatography, Gel - instrumentation
Chromatography, Gel - methods
Cross-Linking Reagents - chemistry
Equipment Failure Analysis
Fractal behavior
Gels - chemistry
Macromolecular Substances
Materials Testing - methods
Molecular Conformation
Organic Chemicals - chemistry
Particle Size
Porosity
Size exclusion chromatography
Swelling and cross-linking degree
Viscosity
title Comparative evaluation of the swelling and degrees of cross-linking in three organic gel packings for SEC through some geometric parameters
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-13T15%3A20%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparative%20evaluation%20of%20the%20swelling%20and%20degrees%20of%20cross-linking%20in%20three%20organic%20gel%20packings%20for%20SEC%20through%20some%20geometric%20parameters&rft.jtitle=Journal%20of%20biochemical%20and%20biophysical%20methods&rft.au=Garc%C4%B1%CC%81a,%20Rosa&rft.date=2003-06-30&rft.volume=56&rft.issue=1&rft.spage=53&rft.epage=67&rft.pages=53-67&rft.issn=0165-022X&rft.eissn=1872-857X&rft_id=info:doi/10.1016/S0165-022X(03)00072-1&rft_dat=%3Cproquest_cross%3E73425830%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73425830&rft_id=info:pmid/12834968&rft_els_id=S0165022X03000721&rfr_iscdi=true