Comparison of the imaging characteristics of curved-channel and straight-channel microchannel plates

We have measured and compared the spatial fidelity of two types of microchannel plates over roughly half of their active area. Measurements of the spatial fidelity of curved-channel microchannel plates confirm earlier reports of large (>25 microm), irregular position offsets between the front and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Optics 1997-02, Vol.36 (4), p.753-759
Hauptverfasser: Osterman, S N, Rottman, G J, Hassler, D M, McClintock, W E, Lawrence, G M
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 759
container_issue 4
container_start_page 753
container_title Applied Optics
container_volume 36
creator Osterman, S N
Rottman, G J
Hassler, D M
McClintock, W E
Lawrence, G M
description We have measured and compared the spatial fidelity of two types of microchannel plates over roughly half of their active area. Measurements of the spatial fidelity of curved-channel microchannel plates confirm earlier reports of large (>25 microm), irregular position offsets between the front and the back of the microchannel plates. Straight-pore microchannel plates used in a chevron configuration, on the other hand, showed almost no such position offsets (
doi_str_mv 10.1364/AO.36.000753
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_734188741</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>734188741</sourcerecordid><originalsourceid>FETCH-LOGICAL-c288t-76b1b5217fcd6fd7178f91a4af18f86b2543abf2f9f7590e4872ca3518b868503</originalsourceid><addsrcrecordid>eNpFkEtLAzEUhYMotlZ3rmV2bpyadzLLUnxBYTYK7kImk7SReZlkBP-9U1p1dR_n43LPAeAawSUinN6vyiXhSwihYOQEzBEjRU4Zxqf7nhU5wvJ9Bi5i_ICQMFqIczBDEjMoCJ2Det23gw4-9l3WuyztbOZbvfXdNjM7HbRJdhKTN3EvmzF82TqflK6zTaa7OospaL_dpb9l603of4eh0cnGS3DmdBPt1bEuwNvjw-v6Od-UTy_r1SY3WMqUC16himEknKm5qwUS0hVIU-2QdJJXmFGiK4dd4QQroKVSYKMJQ7KSXDJIFuD2cHcI_edoY1Ktj8Y2je5sP0Y1OUZSCoom8u5ATr_GGKxTQ5h8h2-FoNrHqlalIlwdYp3wm-PhsWpt_Q8fcyQ_KcJztg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>734188741</pqid></control><display><type>article</type><title>Comparison of the imaging characteristics of curved-channel and straight-channel microchannel plates</title><source>Alma/SFX Local Collection</source><source>Optica Publishing Group Journals</source><creator>Osterman, S N ; Rottman, G J ; Hassler, D M ; McClintock, W E ; Lawrence, G M</creator><creatorcontrib>Osterman, S N ; Rottman, G J ; Hassler, D M ; McClintock, W E ; Lawrence, G M</creatorcontrib><description>We have measured and compared the spatial fidelity of two types of microchannel plates over roughly half of their active area. Measurements of the spatial fidelity of curved-channel microchannel plates confirm earlier reports of large (&gt;25 microm), irregular position offsets between the front and the back of the microchannel plates. Straight-pore microchannel plates used in a chevron configuration, on the other hand, showed almost no such position offsets (&lt;4 microm).</description><identifier>ISSN: 1559-128X</identifier><identifier>ISSN: 0003-6935</identifier><identifier>EISSN: 1539-4522</identifier><identifier>DOI: 10.1364/AO.36.000753</identifier><identifier>PMID: 18250734</identifier><language>eng</language><publisher>United States</publisher><ispartof>Applied Optics, 1997-02, Vol.36 (4), p.753-759</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c288t-76b1b5217fcd6fd7178f91a4af18f86b2543abf2f9f7590e4872ca3518b868503</citedby><cites>FETCH-LOGICAL-c288t-76b1b5217fcd6fd7178f91a4af18f86b2543abf2f9f7590e4872ca3518b868503</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,27929,27930</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18250734$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Osterman, S N</creatorcontrib><creatorcontrib>Rottman, G J</creatorcontrib><creatorcontrib>Hassler, D M</creatorcontrib><creatorcontrib>McClintock, W E</creatorcontrib><creatorcontrib>Lawrence, G M</creatorcontrib><title>Comparison of the imaging characteristics of curved-channel and straight-channel microchannel plates</title><title>Applied Optics</title><addtitle>Appl Opt</addtitle><description>We have measured and compared the spatial fidelity of two types of microchannel plates over roughly half of their active area. Measurements of the spatial fidelity of curved-channel microchannel plates confirm earlier reports of large (&gt;25 microm), irregular position offsets between the front and the back of the microchannel plates. Straight-pore microchannel plates used in a chevron configuration, on the other hand, showed almost no such position offsets (&lt;4 microm).</description><issn>1559-128X</issn><issn>0003-6935</issn><issn>1539-4522</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><recordid>eNpFkEtLAzEUhYMotlZ3rmV2bpyadzLLUnxBYTYK7kImk7SReZlkBP-9U1p1dR_n43LPAeAawSUinN6vyiXhSwihYOQEzBEjRU4Zxqf7nhU5wvJ9Bi5i_ICQMFqIczBDEjMoCJ2Det23gw4-9l3WuyztbOZbvfXdNjM7HbRJdhKTN3EvmzF82TqflK6zTaa7OospaL_dpb9l603of4eh0cnGS3DmdBPt1bEuwNvjw-v6Od-UTy_r1SY3WMqUC16himEknKm5qwUS0hVIU-2QdJJXmFGiK4dd4QQroKVSYKMJQ7KSXDJIFuD2cHcI_edoY1Ktj8Y2je5sP0Y1OUZSCoom8u5ATr_GGKxTQ5h8h2-FoNrHqlalIlwdYp3wm-PhsWpt_Q8fcyQ_KcJztg</recordid><startdate>19970201</startdate><enddate>19970201</enddate><creator>Osterman, S N</creator><creator>Rottman, G J</creator><creator>Hassler, D M</creator><creator>McClintock, W E</creator><creator>Lawrence, G M</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19970201</creationdate><title>Comparison of the imaging characteristics of curved-channel and straight-channel microchannel plates</title><author>Osterman, S N ; Rottman, G J ; Hassler, D M ; McClintock, W E ; Lawrence, G M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c288t-76b1b5217fcd6fd7178f91a4af18f86b2543abf2f9f7590e4872ca3518b868503</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Osterman, S N</creatorcontrib><creatorcontrib>Rottman, G J</creatorcontrib><creatorcontrib>Hassler, D M</creatorcontrib><creatorcontrib>McClintock, W E</creatorcontrib><creatorcontrib>Lawrence, G M</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied Optics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Osterman, S N</au><au>Rottman, G J</au><au>Hassler, D M</au><au>McClintock, W E</au><au>Lawrence, G M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of the imaging characteristics of curved-channel and straight-channel microchannel plates</atitle><jtitle>Applied Optics</jtitle><addtitle>Appl Opt</addtitle><date>1997-02-01</date><risdate>1997</risdate><volume>36</volume><issue>4</issue><spage>753</spage><epage>759</epage><pages>753-759</pages><issn>1559-128X</issn><issn>0003-6935</issn><eissn>1539-4522</eissn><abstract>We have measured and compared the spatial fidelity of two types of microchannel plates over roughly half of their active area. Measurements of the spatial fidelity of curved-channel microchannel plates confirm earlier reports of large (&gt;25 microm), irregular position offsets between the front and the back of the microchannel plates. Straight-pore microchannel plates used in a chevron configuration, on the other hand, showed almost no such position offsets (&lt;4 microm).</abstract><cop>United States</cop><pmid>18250734</pmid><doi>10.1364/AO.36.000753</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1559-128X
ispartof Applied Optics, 1997-02, Vol.36 (4), p.753-759
issn 1559-128X
0003-6935
1539-4522
language eng
recordid cdi_proquest_miscellaneous_734188741
source Alma/SFX Local Collection; Optica Publishing Group Journals
title Comparison of the imaging characteristics of curved-channel and straight-channel microchannel plates
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-13T05%3A26%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20the%20imaging%20characteristics%20of%20curved-channel%20and%20straight-channel%20microchannel%20plates&rft.jtitle=Applied%20Optics&rft.au=Osterman,%20S%20N&rft.date=1997-02-01&rft.volume=36&rft.issue=4&rft.spage=753&rft.epage=759&rft.pages=753-759&rft.issn=1559-128X&rft.eissn=1539-4522&rft_id=info:doi/10.1364/AO.36.000753&rft_dat=%3Cproquest_cross%3E734188741%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=734188741&rft_id=info:pmid/18250734&rfr_iscdi=true