The use of non-collinear mixing for nonlinear ultrasonic detection of plasticity and fatigue

This letter reports on the application of the non-collinear mixing technique to the ultrasonic measurement of material nonlinearity to assess plasticity and fatigue damage. Non-collinear mixing is potentially more attractive for assessing material state than other nonlinear ultrasonic techniques bec...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of the Acoustical Society of America 2009-11, Vol.126 (5), p.EL117-EL122
Hauptverfasser: Croxford, Anthony J., Wilcox, Paul D., Drinkwater, Bruce W., Nagy, Peter B.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This letter reports on the application of the non-collinear mixing technique to the ultrasonic measurement of material nonlinearity to assess plasticity and fatigue damage. Non-collinear mixing is potentially more attractive for assessing material state than other nonlinear ultrasonic techniques because system nonlinearities can be both independently measured and largely eliminated. Here, measurements made on a sample after plastic deformation and on a sample subjected to low-cycle fatigue show that the non-collinear technique is indeed capable of measuring changes in both, and is therefore a viable inspection technique for these types of material degradation.
ISSN:0001-4966
1520-8524